Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.

Identifieur interne : 000724 ( PubMed/Checkpoint ); précédent : 000723; suivant : 000725

Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.

Auteurs : Tarek Mohy Ashmawy ; Dina Bahgat El Talawy ; Nasser Hussein Shaheen

Source :

RBID : pubmed:25019110

Descripteurs français

English descriptors

Abstract

To objectively evaluate the effect of mini-implant- supported mandibular overdentures on electromyographic activity (EMG) of the masseter muscle during chewing of hard and soft foods.

DOI: 10.3290/j.qi.a32236
PubMed: 25019110


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:25019110

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.</title>
<author>
<name sortKey="Ashmawy, Tarek Mohy" sort="Ashmawy, Tarek Mohy" uniqKey="Ashmawy T" first="Tarek Mohy" last="Ashmawy">Tarek Mohy Ashmawy</name>
</author>
<author>
<name sortKey="El Talawy, Dina Bahgat" sort="El Talawy, Dina Bahgat" uniqKey="El Talawy D" first="Dina Bahgat" last="El Talawy">Dina Bahgat El Talawy</name>
</author>
<author>
<name sortKey="Shaheen, Nasser Hussein" sort="Shaheen, Nasser Hussein" uniqKey="Shaheen N" first="Nasser Hussein" last="Shaheen">Nasser Hussein Shaheen</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:25019110</idno>
<idno type="pmid">25019110</idno>
<idno type="doi">10.3290/j.qi.a32236</idno>
<idno type="wicri:Area/PubMed/Corpus">000741</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000741</idno>
<idno type="wicri:Area/PubMed/Curation">000741</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000741</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000741</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000741</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.</title>
<author>
<name sortKey="Ashmawy, Tarek Mohy" sort="Ashmawy, Tarek Mohy" uniqKey="Ashmawy T" first="Tarek Mohy" last="Ashmawy">Tarek Mohy Ashmawy</name>
</author>
<author>
<name sortKey="El Talawy, Dina Bahgat" sort="El Talawy, Dina Bahgat" uniqKey="El Talawy D" first="Dina Bahgat" last="El Talawy">Dina Bahgat El Talawy</name>
</author>
<author>
<name sortKey="Shaheen, Nasser Hussein" sort="Shaheen, Nasser Hussein" uniqKey="Shaheen N" first="Nasser Hussein" last="Shaheen">Nasser Hussein Shaheen</name>
</author>
</analytic>
<series>
<title level="j">Quintessence international (Berlin, Germany : 1985)</title>
<idno type="eISSN">1936-7163</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Cohort Studies</term>
<term>Dental Implants</term>
<term>Denture, Overlay</term>
<term>Electromyography</term>
<term>Female</term>
<term>Food</term>
<term>Humans</term>
<term>Male</term>
<term>Mandible</term>
<term>Masseter Muscle (physiopathology)</term>
<term>Mastication</term>
<term>Middle Aged</term>
<term>Mouth, Edentulous</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Aliments</term>
<term>Bouche édentée</term>
<term>Femelle</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Mandibule</term>
<term>Mastication</term>
<term>Muscle masséter (physiopathologie)</term>
<term>Mâle</term>
<term>Overdenture</term>
<term>Sujet âgé</term>
<term>Électromyographie</term>
<term>Études de cohortes</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr">
<term>Muscle masséter</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Masseter Muscle</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Cohort Studies</term>
<term>Denture, Overlay</term>
<term>Electromyography</term>
<term>Female</term>
<term>Food</term>
<term>Humans</term>
<term>Male</term>
<term>Mandible</term>
<term>Mastication</term>
<term>Middle Aged</term>
<term>Mouth, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Aliments</term>
<term>Bouche édentée</term>
<term>Femelle</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Mandibule</term>
<term>Mastication</term>
<term>Mâle</term>
<term>Overdenture</term>
<term>Sujet âgé</term>
<term>Électromyographie</term>
<term>Études de cohortes</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To objectively evaluate the effect of mini-implant- supported mandibular overdentures on electromyographic activity (EMG) of the masseter muscle during chewing of hard and soft foods.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25019110</PMID>
<DateCompleted>
<Year>2016</Year>
<Month>08</Month>
<Day>08</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>08</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1936-7163</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>45</Volume>
<Issue>8</Issue>
<PubDate>
<Year>2014</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Quintessence international (Berlin, Germany : 1985)</Title>
<ISOAbbreviation>Quintessence Int</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.</ArticleTitle>
<Pagination>
<MedlinePgn>663-71</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.3290/j.qi.a32236</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">To objectively evaluate the effect of mini-implant- supported mandibular overdentures on electromyographic activity (EMG) of the masseter muscle during chewing of hard and soft foods.</AbstractText>
<AbstractText Label="METHOD AND MATERIALS" NlmCategory="METHODS">Twelve completely edentulous patients (4 females and 8 males) with maladaptive experience of wearing mandibular dentures received new maxillary and mandibular dentures. After 3 months of adaptation, four mini dental implants (MDIs) were inserted in the interforaminal region of the mandible, and the new mandibular dentures were connected to the implants immediately with O/ring attachments. The activity of masseter muscle (EMG) and the duration of chewing cycle were measured during chewing hard (carrot) and soft (gum) foods. The measurements were made 3 months after wearing each of the following prostheses: the new conventional dentures; and the MDI-retained mandibular overdentures.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The EMG of masseter muscle increased and the DC decreased with MDI-retained mandibular overdentures when compared to conventional dentures. Hard food (carrot) was associated with increased EMG and decreased DC when compared to soft food (gum) for both conventional dentures and MDI-retained mandibular overdentures.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Mini-implant-supported mandibular overdentures are associated with increased activity of masseter muscle and decreased duration of chewing cycle for both hard and soft foods when compared to conventional dentures.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Ashmawy</LastName>
<ForeName>Tarek Mohy</ForeName>
<Initials>TM</Initials>
</Author>
<Author ValidYN="Y">
<LastName>El Talawy</LastName>
<ForeName>Dina Bahgat</ForeName>
<Initials>DB</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Shaheen</LastName>
<ForeName>Nasser Hussein</ForeName>
<Initials>NH</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Quintessence Int</MedlineTA>
<NlmUniqueID>0342677</NlmUniqueID>
<ISSNLinking>0033-6572</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015331" MajorTopicYN="N">Cohort Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004576" MajorTopicYN="N">Electromyography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005502" MajorTopicYN="Y">Food</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="Y">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008406" MajorTopicYN="N">Masseter Muscle</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="Y">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008409" MajorTopicYN="Y">Mastication</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D009066" MajorTopicYN="N">Mouth, Edentulous</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>7</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>7</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2016</Year>
<Month>8</Month>
<Day>9</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25019110</ArticleId>
<ArticleId IdType="pii">32236</ArticleId>
<ArticleId IdType="doi">10.3290/j.qi.a32236</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Ashmawy, Tarek Mohy" sort="Ashmawy, Tarek Mohy" uniqKey="Ashmawy T" first="Tarek Mohy" last="Ashmawy">Tarek Mohy Ashmawy</name>
<name sortKey="El Talawy, Dina Bahgat" sort="El Talawy, Dina Bahgat" uniqKey="El Talawy D" first="Dina Bahgat" last="El Talawy">Dina Bahgat El Talawy</name>
<name sortKey="Shaheen, Nasser Hussein" sort="Shaheen, Nasser Hussein" uniqKey="Shaheen N" first="Nasser Hussein" last="Shaheen">Nasser Hussein Shaheen</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000724 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000724 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:25019110
   |texte=   Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:25019110" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022