Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs.

Identifieur interne : 000417 ( PubMed/Checkpoint ); précédent : 000416; suivant : 000418

CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs.

Auteurs : Joannis Katsoulis [États-Unis] ; Philipp Müller ; Regina Mericske-Stern ; Markus B. Blatz

Source :

RBID : pubmed:25363301

Descripteurs français

English descriptors

Abstract

To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs.

DOI: 10.1111/clr.12522
PubMed: 25363301


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:25363301

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs.</title>
<author>
<name sortKey="Katsoulis, Joannis" sort="Katsoulis, Joannis" uniqKey="Katsoulis J" first="Joannis" last="Katsoulis">Joannis Katsoulis</name>
<affiliation wicri:level="4">
<nlm:affiliation>Department of Prosthodontics, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Prosthodontics, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA</wicri:regionArea>
<orgName type="university">Université de Berne</orgName>
<placeName>
<settlement type="city">Berne</settlement>
<region nuts="3" type="region">Canton de Berne</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Muller, Philipp" sort="Muller, Philipp" uniqKey="Muller P" first="Philipp" last="Müller">Philipp Müller</name>
</author>
<author>
<name sortKey="Mericske Stern, Regina" sort="Mericske Stern, Regina" uniqKey="Mericske Stern R" first="Regina" last="Mericske-Stern">Regina Mericske-Stern</name>
</author>
<author>
<name sortKey="Blatz, Markus B" sort="Blatz, Markus B" uniqKey="Blatz M" first="Markus B" last="Blatz">Markus B. Blatz</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:25363301</idno>
<idno type="pmid">25363301</idno>
<idno type="doi">10.1111/clr.12522</idno>
<idno type="wicri:Area/PubMed/Corpus">000489</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000489</idno>
<idno type="wicri:Area/PubMed/Curation">000489</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000489</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000489</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000489</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs.</title>
<author>
<name sortKey="Katsoulis, Joannis" sort="Katsoulis, Joannis" uniqKey="Katsoulis J" first="Joannis" last="Katsoulis">Joannis Katsoulis</name>
<affiliation wicri:level="4">
<nlm:affiliation>Department of Prosthodontics, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Prosthodontics, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA</wicri:regionArea>
<orgName type="university">Université de Berne</orgName>
<placeName>
<settlement type="city">Berne</settlement>
<region nuts="3" type="region">Canton de Berne</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Muller, Philipp" sort="Muller, Philipp" uniqKey="Muller P" first="Philipp" last="Müller">Philipp Müller</name>
</author>
<author>
<name sortKey="Mericske Stern, Regina" sort="Mericske Stern, Regina" uniqKey="Mericske Stern R" first="Regina" last="Mericske-Stern">Regina Mericske-Stern</name>
</author>
<author>
<name sortKey="Blatz, Markus B" sort="Blatz, Markus B" uniqKey="Blatz M" first="Markus B" last="Blatz">Markus B. Blatz</name>
</author>
</analytic>
<series>
<title level="j">Clinical oral implants research</title>
<idno type="eISSN">1600-0501</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Ceramics</term>
<term>Computer-Aided Design</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Veneers</term>
<term>Humans</term>
<term>In Vitro Techniques</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Maxilla</term>
<term>Microscopy, Electron, Scanning</term>
<term>Titanium</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Conception assistée par ordinateur</term>
<term>Conception de prothèse dentaire</term>
<term>Céramiques</term>
<term>Facettes dentaires</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Maxillaire</term>
<term>Microscopie électronique à balayage</term>
<term>Mâchoire édentée (rééducation et réadaptation)</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Techniques in vitro</term>
<term>Titane</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
<term>Titanium</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="rééducation et réadaptation" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Ceramics</term>
<term>Computer-Aided Design</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Veneers</term>
<term>Humans</term>
<term>In Vitro Techniques</term>
<term>Maxilla</term>
<term>Microscopy, Electron, Scanning</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Conception assistée par ordinateur</term>
<term>Conception de prothèse dentaire</term>
<term>Céramiques</term>
<term>Facettes dentaires</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Maxillaire</term>
<term>Microscopie électronique à balayage</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Techniques in vitro</term>
<term>Titane</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25363301</PMID>
<DateCompleted>
<Year>2016</Year>
<Month>12</Month>
<Day>13</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>12</Month>
<Day>30</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1600-0501</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>26</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2015</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Clinical oral implants research</Title>
<ISOAbbreviation>Clin Oral Implants Res</ISOAbbreviation>
</Journal>
<ArticleTitle>CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs.</ArticleTitle>
<Pagination>
<MedlinePgn>245-9</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/clr.12522</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.</AbstractText>
<CopyrightInformation>© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Katsoulis</LastName>
<ForeName>Joannis</ForeName>
<Initials>J</Initials>
<AffiliationInfo>
<Affiliation>Department of Prosthodontics, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Müller</LastName>
<ForeName>Philipp</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Mericske-Stern</LastName>
<ForeName>Regina</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Blatz</LastName>
<ForeName>Markus B</ForeName>
<Initials>MB</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2014</Year>
<Month>11</Month>
<Day>03</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Denmark</Country>
<MedlineTA>Clin Oral Implants Res</MedlineTA>
<NlmUniqueID>9105713</NlmUniqueID>
<ISSNLinking>0905-7161</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>D1JT611TNE</RegistryNumber>
<NameOfSubstance UI="D014025">Titanium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D002516" MajorTopicYN="N">Ceramics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="Y">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="N">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003801" MajorTopicYN="N">Dental Veneers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D066298" MajorTopicYN="N">In Vitro Techniques</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008855" MajorTopicYN="N">Microscopy, Electron, Scanning</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014025" MajorTopicYN="N">Titanium</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">CAD/CAM</Keyword>
<Keyword MajorTopicYN="N">fixed dental prosthesis FDP</Keyword>
<Keyword MajorTopicYN="N">framework misfit</Keyword>
<Keyword MajorTopicYN="N">implant-supported</Keyword>
<Keyword MajorTopicYN="N">long-span</Keyword>
<Keyword MajorTopicYN="N">passive fit</Keyword>
<Keyword MajorTopicYN="N">short-span</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="accepted">
<Year>2014</Year>
<Month>10</Month>
<Day>10</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>11</Month>
<Day>4</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>11</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2016</Year>
<Month>12</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25363301</ArticleId>
<ArticleId IdType="doi">10.1111/clr.12522</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Canton de Berne</li>
</region>
<settlement>
<li>Berne</li>
</settlement>
<orgName>
<li>Université de Berne</li>
</orgName>
</list>
<tree>
<noCountry>
<name sortKey="Blatz, Markus B" sort="Blatz, Markus B" uniqKey="Blatz M" first="Markus B" last="Blatz">Markus B. Blatz</name>
<name sortKey="Mericske Stern, Regina" sort="Mericske Stern, Regina" uniqKey="Mericske Stern R" first="Regina" last="Mericske-Stern">Regina Mericske-Stern</name>
<name sortKey="Muller, Philipp" sort="Muller, Philipp" uniqKey="Muller P" first="Philipp" last="Müller">Philipp Müller</name>
</noCountry>
<country name="États-Unis">
<region name="Canton de Berne">
<name sortKey="Katsoulis, Joannis" sort="Katsoulis, Joannis" uniqKey="Katsoulis J" first="Joannis" last="Katsoulis">Joannis Katsoulis</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000417 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000417 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:25363301
   |texte=   CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:25363301" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022