Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.

Identifieur interne : 000376 ( PubMed/Checkpoint ); précédent : 000375; suivant : 000377

Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.

Auteurs : B. Kan [Turquie] ; F M Coskunses [Turquie] ; I. Mutlu [Turquie] ; L. Ugur [Turquie] ; D G Meral [Turquie]

Source :

RBID : pubmed:25818310

Descripteurs français

English descriptors

Abstract

The aim of this three-dimensional finite element analysis study was to examine the biomechanical behaviour of dental implants and the surrounding bone under traumatic frontal force. Models were created of an edentulous atrophic mandible using cone beam computed tomography data from a patient; two titanium alloy implants (Ti-6Al-4V) were virtually inserted into the anterior of the mandible. Six different variations were modelled to represent differences in implant location (lateral incisor vs. canine placement) and implant length (monocortical, bicortical, and long-bicortical). A static force of 10 MPa was applied frontally to the symphysis region of each model, and the maximum equivalent von Mises strain of bone, maximum von Mises stress of implants, and chromatic force distributions in bone and implants were recorded. In general, when compared to lateral incisor placement, canine placement of implants resulted in greater von Mises stress on implants and greater equivalent von Mises strain on bone. The findings of the present study showed the distribution of traumatic force to be affected more by inter-implant distance than by implant length. The insertion of implants in the lateral incisor area was found to be a better solution than canine area placement in terms of frontal plane trauma and fracture risk.

DOI: 10.1016/j.ijom.2015.03.002
PubMed: 25818310


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:25818310

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.</title>
<author>
<name sortKey="Kan, B" sort="Kan, B" uniqKey="Kan B" first="B" last="Kan">B. Kan</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey. Electronic address: bahadirkan@gmail.com.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli</wicri:regionArea>
<wicri:noRegion>Kocaeli</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Coskunses, F M" sort="Coskunses, F M" uniqKey="Coskunses F" first="F M" last="Coskunses">F M Coskunses</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli</wicri:regionArea>
<wicri:noRegion>Kocaeli</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Mutlu, I" sort="Mutlu, I" uniqKey="Mutlu I" first="I" last="Mutlu">I. Mutlu</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Biomechanics, Faculty of Technology, Biomedical Engineering, Kocaeli University, Kocaeli, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Biomechanics, Faculty of Technology, Biomedical Engineering, Kocaeli University, Kocaeli</wicri:regionArea>
<wicri:noRegion>Kocaeli</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ugur, L" sort="Ugur, L" uniqKey="Ugur L" first="L" last="Ugur">L. Ugur</name>
<affiliation wicri:level="1">
<nlm:affiliation>Automotive Department, Technical Science Vocational School, Amasya University, Amasya, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Automotive Department, Technical Science Vocational School, Amasya University, Amasya</wicri:regionArea>
<wicri:noRegion>Amasya</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Meral, D G" sort="Meral, D G" uniqKey="Meral D" first="D G" last="Meral">D G Meral</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Istanbul, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:25818310</idno>
<idno type="pmid">25818310</idno>
<idno type="doi">10.1016/j.ijom.2015.03.002</idno>
<idno type="wicri:Area/PubMed/Corpus">000395</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000395</idno>
<idno type="wicri:Area/PubMed/Curation">000395</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000395</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000395</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000395</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.</title>
<author>
<name sortKey="Kan, B" sort="Kan, B" uniqKey="Kan B" first="B" last="Kan">B. Kan</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey. Electronic address: bahadirkan@gmail.com.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli</wicri:regionArea>
<wicri:noRegion>Kocaeli</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Coskunses, F M" sort="Coskunses, F M" uniqKey="Coskunses F" first="F M" last="Coskunses">F M Coskunses</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli</wicri:regionArea>
<wicri:noRegion>Kocaeli</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Mutlu, I" sort="Mutlu, I" uniqKey="Mutlu I" first="I" last="Mutlu">I. Mutlu</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Biomechanics, Faculty of Technology, Biomedical Engineering, Kocaeli University, Kocaeli, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Biomechanics, Faculty of Technology, Biomedical Engineering, Kocaeli University, Kocaeli</wicri:regionArea>
<wicri:noRegion>Kocaeli</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ugur, L" sort="Ugur, L" uniqKey="Ugur L" first="L" last="Ugur">L. Ugur</name>
<affiliation wicri:level="1">
<nlm:affiliation>Automotive Department, Technical Science Vocational School, Amasya University, Amasya, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Automotive Department, Technical Science Vocational School, Amasya University, Amasya</wicri:regionArea>
<wicri:noRegion>Amasya</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Meral, D G" sort="Meral, D G" uniqKey="Meral D" first="D G" last="Meral">D G Meral</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Istanbul, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International journal of oral and maxillofacial surgery</title>
<idno type="eISSN">1399-0020</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Atrophy</term>
<term>Biomechanical Phenomena</term>
<term>Cone-Beam Computed Tomography</term>
<term>Dental Alloys</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>Dental Stress Analysis</term>
<term>Finite Element Analysis</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Mandible (surgery)</term>
<term>Software</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Alliage dentaire</term>
<term>Analyse des éléments finis</term>
<term>Analyse du stress dentaire</term>
<term>Atrophie</term>
<term>Chirurgie assistée par ordinateur</term>
<term>Conception de prothèse dentaire</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Logiciel</term>
<term>Mandibule ()</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Mâchoire édentée (rééducation et réadaptation)</term>
<term>Phénomènes biomécaniques</term>
<term>Tomodensitométrie à faisceau conique</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Alloys</term>
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="rééducation et réadaptation" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Atrophy</term>
<term>Biomechanical Phenomena</term>
<term>Cone-Beam Computed Tomography</term>
<term>Dental Prosthesis Design</term>
<term>Dental Stress Analysis</term>
<term>Finite Element Analysis</term>
<term>Humans</term>
<term>Software</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Alliage dentaire</term>
<term>Analyse des éléments finis</term>
<term>Analyse du stress dentaire</term>
<term>Atrophie</term>
<term>Chirurgie assistée par ordinateur</term>
<term>Conception de prothèse dentaire</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Logiciel</term>
<term>Mandibule</term>
<term>Phénomènes biomécaniques</term>
<term>Tomodensitométrie à faisceau conique</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of this three-dimensional finite element analysis study was to examine the biomechanical behaviour of dental implants and the surrounding bone under traumatic frontal force. Models were created of an edentulous atrophic mandible using cone beam computed tomography data from a patient; two titanium alloy implants (Ti-6Al-4V) were virtually inserted into the anterior of the mandible. Six different variations were modelled to represent differences in implant location (lateral incisor vs. canine placement) and implant length (monocortical, bicortical, and long-bicortical). A static force of 10 MPa was applied frontally to the symphysis region of each model, and the maximum equivalent von Mises strain of bone, maximum von Mises stress of implants, and chromatic force distributions in bone and implants were recorded. In general, when compared to lateral incisor placement, canine placement of implants resulted in greater von Mises stress on implants and greater equivalent von Mises strain on bone. The findings of the present study showed the distribution of traumatic force to be affected more by inter-implant distance than by implant length. The insertion of implants in the lateral incisor area was found to be a better solution than canine area placement in terms of frontal plane trauma and fracture risk.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25818310</PMID>
<DateCompleted>
<Year>2016</Year>
<Month>03</Month>
<Day>11</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1399-0020</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>44</Volume>
<Issue>7</Issue>
<PubDate>
<Year>2015</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>International journal of oral and maxillofacial surgery</Title>
<ISOAbbreviation>Int J Oral Maxillofac Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.</ArticleTitle>
<Pagination>
<MedlinePgn>908-13</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.ijom.2015.03.002</ELocationID>
<ELocationID EIdType="pii" ValidYN="Y">S0901-5027(15)00096-X</ELocationID>
<Abstract>
<AbstractText>The aim of this three-dimensional finite element analysis study was to examine the biomechanical behaviour of dental implants and the surrounding bone under traumatic frontal force. Models were created of an edentulous atrophic mandible using cone beam computed tomography data from a patient; two titanium alloy implants (Ti-6Al-4V) were virtually inserted into the anterior of the mandible. Six different variations were modelled to represent differences in implant location (lateral incisor vs. canine placement) and implant length (monocortical, bicortical, and long-bicortical). A static force of 10 MPa was applied frontally to the symphysis region of each model, and the maximum equivalent von Mises strain of bone, maximum von Mises stress of implants, and chromatic force distributions in bone and implants were recorded. In general, when compared to lateral incisor placement, canine placement of implants resulted in greater von Mises stress on implants and greater equivalent von Mises strain on bone. The findings of the present study showed the distribution of traumatic force to be affected more by inter-implant distance than by implant length. The insertion of implants in the lateral incisor area was found to be a better solution than canine area placement in terms of frontal plane trauma and fracture risk.</AbstractText>
<CopyrightInformation>Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kan</LastName>
<ForeName>B</ForeName>
<Initials>B</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey. Electronic address: bahadirkan@gmail.com.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Coskunses</LastName>
<ForeName>F M</ForeName>
<Initials>FM</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Mutlu</LastName>
<ForeName>I</ForeName>
<Initials>I</Initials>
<AffiliationInfo>
<Affiliation>Department of Biomechanics, Faculty of Technology, Biomedical Engineering, Kocaeli University, Kocaeli, Turkey.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Ugur</LastName>
<ForeName>L</ForeName>
<Initials>L</Initials>
<AffiliationInfo>
<Affiliation>Automotive Department, Technical Science Vocational School, Amasya University, Amasya, Turkey.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Meral</LastName>
<ForeName>D G</ForeName>
<Initials>DG</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Istanbul, Turkey.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2015</Year>
<Month>03</Month>
<Day>25</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Denmark</Country>
<MedlineTA>Int J Oral Maxillofac Surg</MedlineTA>
<NlmUniqueID>8605826</NlmUniqueID>
<ISSNLinking>0901-5027</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003722">Dental Alloys</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D001284" MajorTopicYN="N">Atrophy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001696" MajorTopicYN="N">Biomechanical Phenomena</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D054893" MajorTopicYN="N">Cone-Beam Computed Tomography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003722" MajorTopicYN="N">Dental Alloys</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="Y">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003799" MajorTopicYN="N">Dental Stress Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D020342" MajorTopicYN="Y">Finite Element Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012984" MajorTopicYN="N">Software</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D025321" MajorTopicYN="N">Surgery, Computer-Assisted</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">dental implant</Keyword>
<Keyword MajorTopicYN="N">fracture</Keyword>
<Keyword MajorTopicYN="N">mandible</Keyword>
<Keyword MajorTopicYN="N">von Mises</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2014</Year>
<Month>07</Month>
<Day>09</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2015</Year>
<Month>01</Month>
<Day>08</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2015</Year>
<Month>03</Month>
<Day>04</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2015</Year>
<Month>3</Month>
<Day>31</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2015</Year>
<Month>3</Month>
<Day>31</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2016</Year>
<Month>3</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25818310</ArticleId>
<ArticleId IdType="pii">S0901-5027(15)00096-X</ArticleId>
<ArticleId IdType="doi">10.1016/j.ijom.2015.03.002</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Turquie</li>
</country>
</list>
<tree>
<country name="Turquie">
<noRegion>
<name sortKey="Kan, B" sort="Kan, B" uniqKey="Kan B" first="B" last="Kan">B. Kan</name>
</noRegion>
<name sortKey="Coskunses, F M" sort="Coskunses, F M" uniqKey="Coskunses F" first="F M" last="Coskunses">F M Coskunses</name>
<name sortKey="Meral, D G" sort="Meral, D G" uniqKey="Meral D" first="D G" last="Meral">D G Meral</name>
<name sortKey="Mutlu, I" sort="Mutlu, I" uniqKey="Mutlu I" first="I" last="Mutlu">I. Mutlu</name>
<name sortKey="Ugur, L" sort="Ugur, L" uniqKey="Ugur L" first="L" last="Ugur">L. Ugur</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000376 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000376 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:25818310
   |texte=   Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:25818310" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022