Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

Identifieur interne : 002B53 ( Pmc/Curation ); précédent : 002B52; suivant : 002B54

Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

Auteurs : Glenn Hsuan-Chen Chang ; Chen Tian ; Yuen-Siang Hung

Source :

RBID : PMC:3214526

Abstract

Purpose:

An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients.

Materials and Methods:

A newly designed dental implant fixture mount (DIFMA) can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented.

Results:

A clinical case utilizing the fixture mount abutment (DIFMA)/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered.

Conclusions:

More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment.


Url:
DOI: 10.4103/0976-237X.86456
PubMed: 22090763
PubMed Central: 3214526

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:3214526

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well</title>
<author>
<name sortKey="Chang, Glenn Hsuan Chen" sort="Chang, Glenn Hsuan Chen" uniqKey="Chang G" first="Glenn Hsuan-Chen" last="Chang">Glenn Hsuan-Chen Chang</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Tian, Chen" sort="Tian, Chen" uniqKey="Tian C" first="Chen" last="Tian">Chen Tian</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Mechanical Engineer, Industrial Engineer, Wildomar, USA</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Hung, Yuen Siang" sort="Hung, Yuen Siang" uniqKey="Hung Y" first="Yuen-Siang" last="Hung">Yuen-Siang Hung</name>
<affiliation>
<nlm:aff id="aff3">
<italic>Prosthodontist, Private Practice, USC Advanced Prosthodontic Gruaduate, CEO of AIDI Biomedical Inc., Wiodomar, CA, USA</italic>
</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">22090763</idno>
<idno type="pmc">3214526</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214526</idno>
<idno type="RBID">PMC:3214526</idno>
<idno type="doi">10.4103/0976-237X.86456</idno>
<date when="2011">2011</date>
<idno type="wicri:Area/Pmc/Corpus">002B53</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002B53</idno>
<idno type="wicri:Area/Pmc/Curation">002B53</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">002B53</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well</title>
<author>
<name sortKey="Chang, Glenn Hsuan Chen" sort="Chang, Glenn Hsuan Chen" uniqKey="Chang G" first="Glenn Hsuan-Chen" last="Chang">Glenn Hsuan-Chen Chang</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Tian, Chen" sort="Tian, Chen" uniqKey="Tian C" first="Chen" last="Tian">Chen Tian</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Mechanical Engineer, Industrial Engineer, Wildomar, USA</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Hung, Yuen Siang" sort="Hung, Yuen Siang" uniqKey="Hung Y" first="Yuen-Siang" last="Hung">Yuen-Siang Hung</name>
<affiliation>
<nlm:aff id="aff3">
<italic>Prosthodontist, Private Practice, USC Advanced Prosthodontic Gruaduate, CEO of AIDI Biomedical Inc., Wiodomar, CA, USA</italic>
</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Contemporary Clinical Dentistry</title>
<idno type="ISSN">0976-237X</idno>
<idno type="eISSN">0976-2361</idno>
<imprint>
<date when="2011">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec id="st1">
<title>Purpose:</title>
<p>An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients.</p>
</sec>
<sec id="st2">
<title>Materials and Methods:</title>
<p>A newly designed dental implant fixture mount (DIFMA) can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented.</p>
</sec>
<sec id="st3">
<title>Results:</title>
<p>A clinical case utilizing the fixture mount abutment (DIFMA)/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered.</p>
</sec>
<sec id="st4">
<title>Conclusions:</title>
<p>More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Schwartz Arad, D" uniqKey="Schwartz Arad D">D Schwartz-Arad</name>
</author>
<author>
<name sortKey="Chaushu, G" uniqKey="Chaushu G">G Chaushu</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mal, P" uniqKey="Mal P">P Maló</name>
</author>
<author>
<name sortKey="Rangert, B" uniqKey="Rangert B">B Rangert</name>
</author>
<author>
<name sortKey="Nobre, M" uniqKey="Nobre M">M Nobre</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mccarthy, Gr" uniqKey="Mccarthy G">GR McCarthy</name>
</author>
<author>
<name sortKey="Morgan, Vl" uniqKey="Morgan V">VL Morgan</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Papazian, S" uniqKey="Papazian S">S Papazian</name>
</author>
<author>
<name sortKey="Morgano, Sm" uniqKey="Morgano S">SM Morgano</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ganddini, Mr" uniqKey="Ganddini M">MR Ganddini</name>
</author>
<author>
<name sortKey="Schejtman, N" uniqKey="Schejtman N">N Schejtman</name>
</author>
<author>
<name sortKey="Ercoli, C" uniqKey="Ercoli C">C Ercoli</name>
</author>
<author>
<name sortKey="Graser, Gn" uniqKey="Graser G">GN Graser</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ostman, Po" uniqKey="Ostman P">PO Ostman</name>
</author>
<author>
<name sortKey="Hellman, M" uniqKey="Hellman M">M Hellman</name>
</author>
<author>
<name sortKey="Albrektsson, T" uniqKey="Albrektsson T">T Albrektsson</name>
</author>
<author>
<name sortKey="Sennerby, L" uniqKey="Sennerby L">L Sennerby</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hui, E" uniqKey="Hui E">E Hui</name>
</author>
<author>
<name sortKey="Chow, J" uniqKey="Chow J">J Chow</name>
</author>
<author>
<name sortKey="Li, D" uniqKey="Li D">D Li</name>
</author>
<author>
<name sortKey="Liu, J" uniqKey="Liu J">J Liu</name>
</author>
<author>
<name sortKey="Wat, P" uniqKey="Wat P">P Wat</name>
</author>
<author>
<name sortKey="Law, H" uniqKey="Law H">H Law</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Aalam, Aa" uniqKey="Aalam A">AA Aalam</name>
</author>
<author>
<name sortKey="Nowzari, H" uniqKey="Nowzari H">H Nowzari</name>
</author>
<author>
<name sortKey="Krivitsky, A" uniqKey="Krivitsky A">A Krivitsky</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Testori, T" uniqKey="Testori T">T Testori</name>
</author>
<author>
<name sortKey="Szmukler Moncler, S" uniqKey="Szmukler Moncler S">S Szmukler-Moncler</name>
</author>
<author>
<name sortKey="Francetti, L" uniqKey="Francetti L">L Francetti</name>
</author>
<author>
<name sortKey="Del Fabbro, M" uniqKey="Del Fabbro M">M Del Fabbro</name>
</author>
<author>
<name sortKey="Scarano, A" uniqKey="Scarano A">A Scarano</name>
</author>
<author>
<name sortKey="Piattelli, A" uniqKey="Piattelli A">A Piattelli</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bergkvist, G" uniqKey="Bergkvist G">G Bergkvist</name>
</author>
<author>
<name sortKey="Sahlholm, S" uniqKey="Sahlholm S">S Sahlholm</name>
</author>
<author>
<name sortKey="Karlsson, U" uniqKey="Karlsson U">U Karlsson</name>
</author>
<author>
<name sortKey="Nilner, K" uniqKey="Nilner K">K Nilner</name>
</author>
<author>
<name sortKey="Lindh, C" uniqKey="Lindh C">C Lindh</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Iba Ez, Jc" uniqKey="Iba Ez J">JC Ibañez</name>
</author>
<author>
<name sortKey="Tahhan, Mj" uniqKey="Tahhan M">MJ Tahhan</name>
</author>
<author>
<name sortKey="Zamar, Ja" uniqKey="Zamar J">JA Zamar</name>
</author>
<author>
<name sortKey="Menendez, Ab" uniqKey="Menendez A">AB Menendez</name>
</author>
<author>
<name sortKey="Juaneda, Am" uniqKey="Juaneda A">AM Juaneda</name>
</author>
<author>
<name sortKey="Zamar, Nj" uniqKey="Zamar N">NJ Zamar</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Degidi, M" uniqKey="Degidi M">M Degidi</name>
</author>
<author>
<name sortKey="Piattelli, A" uniqKey="Piattelli A">A Piattelli</name>
</author>
<author>
<name sortKey="Felice, P" uniqKey="Felice P">P Felice</name>
</author>
<author>
<name sortKey="Carinci, F" uniqKey="Carinci F">F Carinci</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Machtei, Ee" uniqKey="Machtei E">EE Machtei</name>
</author>
<author>
<name sortKey="Frankenthal, S" uniqKey="Frankenthal S">S Frankenthal</name>
</author>
<author>
<name sortKey="Blumenfeld, I" uniqKey="Blumenfeld I">I Blumenfeld</name>
</author>
<author>
<name sortKey="Gutmacher, Z" uniqKey="Gutmacher Z">Z Gutmacher</name>
</author>
<author>
<name sortKey="Horwitz, J" uniqKey="Horwitz J">J Horwitz</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Roccuzzo, M" uniqKey="Roccuzzo M">M Roccuzzo</name>
</author>
<author>
<name sortKey="Bunino, M" uniqKey="Bunino M">M Bunino</name>
</author>
<author>
<name sortKey="Prioglio, F" uniqKey="Prioglio F">F Prioglio</name>
</author>
<author>
<name sortKey="Bianchi, Sd" uniqKey="Bianchi S">SD Bianchi</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Contemp Clin Dent</journal-id>
<journal-id journal-id-type="publisher-id">CCD</journal-id>
<journal-title-group>
<journal-title>Contemporary Clinical Dentistry</journal-title>
</journal-title-group>
<issn pub-type="ppub">0976-237X</issn>
<issn pub-type="epub">0976-2361</issn>
<publisher>
<publisher-name>Medknow Publications Pvt Ltd</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">22090763</article-id>
<article-id pub-id-type="pmc">3214526</article-id>
<article-id pub-id-type="publisher-id">CCD-2-194</article-id>
<article-id pub-id-type="doi">10.4103/0976-237X.86456</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Chang</surname>
<given-names>Glenn Hsuan-Chen</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
<xref ref-type="corresp" rid="cor1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Tian</surname>
<given-names>Chen</given-names>
</name>
<xref ref-type="aff" rid="aff2">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Hung</surname>
<given-names>Yuen-Siang</given-names>
</name>
<xref ref-type="aff" rid="aff3">2</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<italic>Periodontist, Private Practice, Los Angeles, USA</italic>
</aff>
<aff id="aff2">
<label>1</label>
<italic>Mechanical Engineer, Industrial Engineer, Wildomar, USA</italic>
</aff>
<aff id="aff3">
<label>2</label>
<italic>Prosthodontist, Private Practice, USC Advanced Prosthodontic Gruaduate, CEO of AIDI Biomedical Inc., Wiodomar, CA, USA</italic>
</aff>
<author-notes>
<corresp id="cor1">
<bold>Correspondence:</bold>
Mr. Glenn Hsuan-Chen Chang, 2957 Steeple Chase Dr., Chino Hills, CA 91709, USA. E-mail:
<email xlink:href="glennhchang@yahoo.com">glennhchang@yahoo.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<season>Jul-Sep</season>
<year>2011</year>
</pub-date>
<volume>2</volume>
<issue>3</issue>
<fpage>194</fpage>
<lpage>199</lpage>
<permissions>
<copyright-statement>Copyright: © Contemporary Clinical Dentistry</copyright-statement>
<copyright-year>2011</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc-sa/3.0">
<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<sec id="st1">
<title>Purpose:</title>
<p>An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients.</p>
</sec>
<sec id="st2">
<title>Materials and Methods:</title>
<p>A newly designed dental implant fixture mount (DIFMA) can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented.</p>
</sec>
<sec id="st3">
<title>Results:</title>
<p>A clinical case utilizing the fixture mount abutment (DIFMA)/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered.</p>
</sec>
<sec id="st4">
<title>Conclusions:</title>
<p>More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Fixture mount</kwd>
<kwd>impression coping</kwd>
<kwd>implant</kwd>
<kwd>immediate load</kwd>
<kwd>provisional abutment</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002B53 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd -nk 002B53 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:3214526
   |texte=   Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Curation/RBID.i   -Sk "pubmed:22090763" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022