Evaluation of Four Elastomeric Interocclusal Recording Materials

Identifieur interne : 002493 ( Pmc/Curation ); précédent : 002492; suivant : 002494

Evaluation of Four Elastomeric Interocclusal Recording Materials

Auteurs : P. Dua ; Sh Gupta ; S. Ramachandran ; Hs Sandhu

Source :

RBID : PMC:4922742

Abstract

Background

The fabrication of dental prosthesis requires the transfer of interocclusal records from patient's mouth to semi-adjustable articulators using different kinds of recording media. Any inaccuracy in these interocclusal records leads to occlusal errors in the final prosthesis. This study was conducted to evaluate the dimensional changes occurring in the interocclusal recording material over a given period of time and the material's resistance to compression during the cast mounting on the articulator.

Methods

In this in vitro study, the linear dimensional change and compressive resistance of four commercially available elastomeric interocclusal recording media was tested. Three were addition silicones and the fourth was a polyether material. Cylindrical samples of 10mm diameter of each material were prepared in three different thicknesses of 2, 4 and 6mm. Ten samples each of thickness of 2, 4 and 6mm for all four materials were prepared (total of 120 samples). The linear dimensional changes of the samples were evaluated after 24 hours of fabrication. The compressive resistance was measured when each of these was subjected to a constant compressive load of 25 Newtons.

Results

The mean linear dimensional change in a horizontal plane was minimum for Kanibite Hard, an addition silicone. Ramitec showed the maximum linear dimensional change. The mean compression distance was least for Futar D Occlusion (an addition silicone) and maximum for Ramitec (a polyether). It was observed that the samples of thickness 2mm for all the materials underwent least compression.

Conclusion

The compressive resistance of each elastomer was inversely proportional to the thickness of the sample. This implies that minimum thickness of the recording materials should be used for recording maxillomandibular relations without sacrificing the strength of the interocclusal record.


Url:
DOI: 10.1016/S0377-1237(07)80143-2
PubMed: 27408006
PubMed Central: 4922742

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4922742

Curation

No country items

P. Dua
<affiliation>
<nlm:aff id="aff1">Graded Specialist (Prosthodontics) OC, Military Dental Centre, Amritsar-143001</nlm:aff>
<wicri:noCountry code="subfield">Amritsar-143001</wicri:noCountry>
</affiliation>
Sh Gupta
<affiliation>
<nlm:aff id="aff2">Classified Specialist (Prosthodontics), Air Force Institute of Dental Sciences, Agram Post, Bangalore - 560007</nlm:aff>
<wicri:noCountry code="subfield">Bangalore - 560007</wicri:noCountry>
</affiliation>
S. Ramachandran
<affiliation>
<nlm:aff id="aff3">Associate Professor (Prosthodontics), Dept of Dental Surgery, AFMC, Pune</nlm:aff>
<wicri:noCountry code="subfield">Pune</wicri:noCountry>
</affiliation>
Hs Sandhu
<affiliation>
<nlm:aff id="aff4">Classified Specialist (Prosthodontics), 33 Corps Dental Unit, C/o 99 APO</nlm:aff>
<wicri:noCountry code="subfield">C/o 99 APO</wicri:noCountry>
</affiliation>

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Evaluation of Four Elastomeric Interocclusal Recording Materials</title>
<author>
<name sortKey="Dua, P" sort="Dua, P" uniqKey="Dua P" first="P" last="Dua">P. Dua</name>
<affiliation>
<nlm:aff id="aff1">Graded Specialist (Prosthodontics) OC, Military Dental Centre, Amritsar-143001</nlm:aff>
<wicri:noCountry code="subfield">Amritsar-143001</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Gupta, Sh" sort="Gupta, Sh" uniqKey="Gupta S" first="Sh" last="Gupta">Sh Gupta</name>
<affiliation>
<nlm:aff id="aff2">Classified Specialist (Prosthodontics), Air Force Institute of Dental Sciences, Agram Post, Bangalore - 560007</nlm:aff>
<wicri:noCountry code="subfield">Bangalore - 560007</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Ramachandran, S" sort="Ramachandran, S" uniqKey="Ramachandran S" first="S" last="Ramachandran">S. Ramachandran</name>
<affiliation>
<nlm:aff id="aff3">Associate Professor (Prosthodontics), Dept of Dental Surgery, AFMC, Pune</nlm:aff>
<wicri:noCountry code="subfield">Pune</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Sandhu, Hs" sort="Sandhu, Hs" uniqKey="Sandhu H" first="Hs" last="Sandhu">Hs Sandhu</name>
<affiliation>
<nlm:aff id="aff4">Classified Specialist (Prosthodontics), 33 Corps Dental Unit, C/o 99 APO</nlm:aff>
<wicri:noCountry code="subfield">C/o 99 APO</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">27408006</idno>
<idno type="pmc">4922742</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4922742</idno>
<idno type="RBID">PMC:4922742</idno>
<idno type="doi">10.1016/S0377-1237(07)80143-2</idno>
<date when="2007">2007</date>
<idno type="wicri:Area/Pmc/Corpus">002493</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002493</idno>
<idno type="wicri:Area/Pmc/Curation">002493</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">002493</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Evaluation of Four Elastomeric Interocclusal Recording Materials</title>
<author>
<name sortKey="Dua, P" sort="Dua, P" uniqKey="Dua P" first="P" last="Dua">P. Dua</name>
<affiliation>
<nlm:aff id="aff1">Graded Specialist (Prosthodontics) OC, Military Dental Centre, Amritsar-143001</nlm:aff>
<wicri:noCountry code="subfield">Amritsar-143001</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Gupta, Sh" sort="Gupta, Sh" uniqKey="Gupta S" first="Sh" last="Gupta">Sh Gupta</name>
<affiliation>
<nlm:aff id="aff2">Classified Specialist (Prosthodontics), Air Force Institute of Dental Sciences, Agram Post, Bangalore - 560007</nlm:aff>
<wicri:noCountry code="subfield">Bangalore - 560007</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Ramachandran, S" sort="Ramachandran, S" uniqKey="Ramachandran S" first="S" last="Ramachandran">S. Ramachandran</name>
<affiliation>
<nlm:aff id="aff3">Associate Professor (Prosthodontics), Dept of Dental Surgery, AFMC, Pune</nlm:aff>
<wicri:noCountry code="subfield">Pune</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Sandhu, Hs" sort="Sandhu, Hs" uniqKey="Sandhu H" first="Hs" last="Sandhu">Hs Sandhu</name>
<affiliation>
<nlm:aff id="aff4">Classified Specialist (Prosthodontics), 33 Corps Dental Unit, C/o 99 APO</nlm:aff>
<wicri:noCountry code="subfield">C/o 99 APO</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Medical Journal, Armed Forces India</title>
<idno type="ISSN">0377-1237</idno>
<imprint>
<date when="2007">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Background</title>
<p>The fabrication of dental prosthesis requires the transfer of interocclusal records from patient's mouth to semi-adjustable articulators using different kinds of recording media. Any inaccuracy in these interocclusal records leads to occlusal errors in the final prosthesis. This study was conducted to evaluate the dimensional changes occurring in the interocclusal recording material over a given period of time and the material's resistance to compression during the cast mounting on the articulator.</p>
</sec>
<sec>
<title>Methods</title>
<p>In this in vitro study, the linear dimensional change and compressive resistance of four commercially available elastomeric interocclusal recording media was tested. Three were addition silicones and the fourth was a polyether material. Cylindrical samples of 10mm diameter of each material were prepared in three different thicknesses of 2, 4 and 6mm. Ten samples each of thickness of 2, 4 and 6mm for all four materials were prepared (total of 120 samples). The linear dimensional changes of the samples were evaluated after 24 hours of fabrication. The compressive resistance was measured when each of these was subjected to a constant compressive load of 25 Newtons.</p>
</sec>
<sec>
<title>Results</title>
<p>The mean linear dimensional change in a horizontal plane was minimum for Kanibite Hard, an addition silicone. Ramitec showed the maximum linear dimensional change. The mean compression distance was least for Futar D Occlusion (an addition silicone) and maximum for Ramitec (a polyether). It was observed that the samples of thickness 2mm for all the materials underwent least compression.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>The compressive resistance of each elastomer was inversely proportional to the thickness of the sample. This implies that minimum thickness of the recording materials should be used for recording maxillomandibular relations without sacrificing the strength of the interocclusal record.</p>
</sec>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Med J Armed Forces India</journal-id>
<journal-id journal-id-type="iso-abbrev">Med J Armed Forces India</journal-id>
<journal-title-group>
<journal-title>Medical Journal, Armed Forces India</journal-title>
</journal-title-group>
<issn pub-type="ppub">0377-1237</issn>
<publisher>
<publisher-name>Elsevier</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">27408006</article-id>
<article-id pub-id-type="pmc">4922742</article-id>
<article-id pub-id-type="publisher-id">S0377-1237(07)80143-2</article-id>
<article-id pub-id-type="doi">10.1016/S0377-1237(07)80143-2</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Evaluation of Four Elastomeric Interocclusal Recording Materials</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Dua</surname>
<given-names>P</given-names>
</name>
<xref rid="aff1" ref-type="aff">*</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gupta</surname>
<given-names>SH</given-names>
</name>
<xref rid="aff2" ref-type="aff">+</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ramachandran</surname>
<given-names>S</given-names>
</name>
<xref rid="aff3" ref-type="aff">#</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sandhu</surname>
<given-names>HS</given-names>
</name>
<xref rid="aff4" ref-type="aff">**</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<label>*</label>
Graded Specialist (Prosthodontics) OC, Military Dental Centre, Amritsar-143001</aff>
<aff id="aff2">
<label>+</label>
Classified Specialist (Prosthodontics), Air Force Institute of Dental Sciences, Agram Post, Bangalore - 560007</aff>
<aff id="aff3">
<label>#</label>
Associate Professor (Prosthodontics), Dept of Dental Surgery, AFMC, Pune</aff>
<aff id="aff4">
<label>**</label>
Classified Specialist (Prosthodontics), 33 Corps Dental Unit, C/o 99 APO</aff>
<pub-date pub-type="ppub">
<month>7</month>
<year>2007</year>
</pub-date>
<pub-date pub-type="epub">
<day>21</day>
<month>7</month>
<year>2011</year>
</pub-date>
<volume>63</volume>
<issue>3</issue>
<fpage>237</fpage>
<lpage>240</lpage>
<history>
<date date-type="received">
<day>28</day>
<month>6</month>
<year>2005</year>
</date>
<date date-type="accepted">
<day>19</day>
<month>12</month>
<year>2005</year>
</date>
</history>
<permissions>
<copyright-statement>.</copyright-statement>
<copyright-year>2007</copyright-year>
<copyright-holder>Director General, Armed Forces Medical Services</copyright-holder>
</permissions>
<abstract id="ceab10">
<sec>
<title>Background</title>
<p>The fabrication of dental prosthesis requires the transfer of interocclusal records from patient's mouth to semi-adjustable articulators using different kinds of recording media. Any inaccuracy in these interocclusal records leads to occlusal errors in the final prosthesis. This study was conducted to evaluate the dimensional changes occurring in the interocclusal recording material over a given period of time and the material's resistance to compression during the cast mounting on the articulator.</p>
</sec>
<sec>
<title>Methods</title>
<p>In this in vitro study, the linear dimensional change and compressive resistance of four commercially available elastomeric interocclusal recording media was tested. Three were addition silicones and the fourth was a polyether material. Cylindrical samples of 10mm diameter of each material were prepared in three different thicknesses of 2, 4 and 6mm. Ten samples each of thickness of 2, 4 and 6mm for all four materials were prepared (total of 120 samples). The linear dimensional changes of the samples were evaluated after 24 hours of fabrication. The compressive resistance was measured when each of these was subjected to a constant compressive load of 25 Newtons.</p>
</sec>
<sec>
<title>Results</title>
<p>The mean linear dimensional change in a horizontal plane was minimum for Kanibite Hard, an addition silicone. Ramitec showed the maximum linear dimensional change. The mean compression distance was least for Futar D Occlusion (an addition silicone) and maximum for Ramitec (a polyether). It was observed that the samples of thickness 2mm for all the materials underwent least compression.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>The compressive resistance of each elastomer was inversely proportional to the thickness of the sample. This implies that minimum thickness of the recording materials should be used for recording maxillomandibular relations without sacrificing the strength of the interocclusal record.</p>
</sec>
</abstract>
<kwd-group id="cekeyws10">
<title>Key Words</title>
<kwd>Interocclusal records</kwd>
<kwd>Articulation</kwd>
<kwd>Occlusion</kwd>
<kwd>Linear dimensional change</kwd>
<kwd>Compressive resistance</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002493 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd -nk 002493 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:4922742
   |texte=   Evaluation of Four Elastomeric Interocclusal Recording Materials
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Curation/RBID.i   -Sk "pubmed:27408006" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022