A Finite Element Analysis of Stress Distribution in the Bone, Around the Implant Supporting a Mandibular Overdenture with Ball/O Ring and Magnetic Attachment

Identifieur interne : 000A66 ( Pmc/Curation ); précédent : 000A65; suivant : 000A67

A Finite Element Analysis of Stress Distribution in the Bone, Around the Implant Supporting a Mandibular Overdenture with Ball/O Ring and Magnetic Attachment

Auteurs : Jins John [Inde] ; V. Rangarajan [Inde] ; Ravindra C. Savadi [Inde] ; K. S. Satheesh Kumar [Inde] ; Preeti Satheesh Kumar [Inde]

Source :

RBID : PMC:3332316

Abstract

Today implant dentistry has made great inroads into the treatment modalities that are available in treating an edentulous patient. Popularity of a two implant retained overdenture has created a necessity to examine the various attachment systems being used and the stresses that are transmitted to the alveolar bone. Hence a Three dimensional Finite Element Analysis was done to analyze the stress distribution in the mandibular bone with implant-supported overdenture having Ball/O-ring and Magnet attachments of different diameters. A segment of the anterior region of the mandible was modeled with implant and the overdenture. Four different models were generated having Ball/O-Ring and Magnet Attachments. Forces of 10 N, 35 N and 70 N were applied from the horizontal, vertical and oblique directions respectively and the stress distribution studied. It was concluded that the greatest stress concentrations were seen at the crest of the cortical bone and could be reduced by using smaller sized attachments for implant supported-overdenture.


Url:
DOI: 10.1007/s13191-012-0114-0
PubMed: 23450217
PubMed Central: 3332316

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:3332316

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A Finite Element Analysis of Stress Distribution in the Bone, Around the Implant Supporting a Mandibular Overdenture with Ball/O Ring and Magnetic Attachment</title>
<author>
<name sortKey="John, Jins" sort="John, Jins" uniqKey="John J" first="Jins" last="John">Jins John</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Rangarajan, V" sort="Rangarajan, V" uniqKey="Rangarajan V" first="V." last="Rangarajan">V. Rangarajan</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Savadi, Ravindra C" sort="Savadi, Ravindra C" uniqKey="Savadi R" first="Ravindra C." last="Savadi">Ravindra C. Savadi</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Satheesh Kumar, K S" sort="Satheesh Kumar, K S" uniqKey="Satheesh Kumar K" first="K. S." last="Satheesh Kumar">K. S. Satheesh Kumar</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Satheesh Kumar, Preeti" sort="Satheesh Kumar, Preeti" uniqKey="Satheesh Kumar P" first="Preeti" last="Satheesh Kumar">Preeti Satheesh Kumar</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">23450217</idno>
<idno type="pmc">3332316</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3332316</idno>
<idno type="RBID">PMC:3332316</idno>
<idno type="doi">10.1007/s13191-012-0114-0</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">000A66</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000A66</idno>
<idno type="wicri:Area/Pmc/Curation">000A66</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000A66</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">A Finite Element Analysis of Stress Distribution in the Bone, Around the Implant Supporting a Mandibular Overdenture with Ball/O Ring and Magnetic Attachment</title>
<author>
<name sortKey="John, Jins" sort="John, Jins" uniqKey="John J" first="Jins" last="John">Jins John</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Rangarajan, V" sort="Rangarajan, V" uniqKey="Rangarajan V" first="V." last="Rangarajan">V. Rangarajan</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Savadi, Ravindra C" sort="Savadi, Ravindra C" uniqKey="Savadi R" first="Ravindra C." last="Savadi">Ravindra C. Savadi</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Satheesh Kumar, K S" sort="Satheesh Kumar, K S" uniqKey="Satheesh Kumar K" first="K. S." last="Satheesh Kumar">K. S. Satheesh Kumar</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Satheesh Kumar, Preeti" sort="Satheesh Kumar, Preeti" uniqKey="Satheesh Kumar P" first="Preeti" last="Satheesh Kumar">Preeti Satheesh Kumar</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>The Oxford Dental College, Bangalore</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The Journal of the Indian Prosthodontic Society</title>
<idno type="ISSN">0972-4052</idno>
<idno type="eISSN">1998-4057</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>Today implant dentistry has made great inroads into the treatment modalities that are available in treating an edentulous patient. Popularity of a two implant retained overdenture has created a necessity to examine the various attachment systems being used and the stresses that are transmitted to the alveolar bone. Hence a Three dimensional Finite Element Analysis was done to analyze the stress distribution in the mandibular bone with implant-supported overdenture having Ball/O-ring and Magnet attachments of different diameters. A segment of the anterior region of the mandible was modeled with implant and the overdenture. Four different models were generated having Ball/O-Ring and Magnet Attachments. Forces of 10 N, 35 N and 70 N were applied from the horizontal, vertical and oblique directions respectively and the stress distribution studied. It was concluded that the greatest stress concentrations were seen at the crest of the cortical bone and could be reduced by using smaller sized attachments for implant supported-overdenture.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Indian Prosthodont Soc</journal-id>
<journal-id journal-id-type="iso-abbrev">J Indian Prosthodont Soc</journal-id>
<journal-title-group>
<journal-title>The Journal of the Indian Prosthodontic Society</journal-title>
</journal-title-group>
<issn pub-type="ppub">0972-4052</issn>
<issn pub-type="epub">1998-4057</issn>
<publisher>
<publisher-name>Springer-Verlag</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">23450217</article-id>
<article-id pub-id-type="pmc">3332316</article-id>
<article-id pub-id-type="publisher-id">114</article-id>
<article-id pub-id-type="doi">10.1007/s13191-012-0114-0</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>A Finite Element Analysis of Stress Distribution in the Bone, Around the Implant Supporting a Mandibular Overdenture with Ball/O Ring and Magnetic Attachment</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>John</surname>
<given-names>Jins</given-names>
</name>
<address>
<email>drjinsjohn@hotmail.com</email>
</address>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Rangarajan</surname>
<given-names>V.</given-names>
</name>
<address>
<email>drvranga@gmail.com</email>
</address>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Savadi</surname>
<given-names>Ravindra C.</given-names>
</name>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Satheesh Kumar</surname>
<given-names>K. S.</given-names>
</name>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Satheesh Kumar</surname>
<given-names>Preeti</given-names>
</name>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<aff id="Aff1">The Oxford Dental College, Bangalore, 560 068 India</aff>
</contrib-group>
<pub-date pub-type="epub">
<day>9</day>
<month>3</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="ppub">
<month>3</month>
<year>2012</year>
</pub-date>
<volume>12</volume>
<issue>1</issue>
<fpage>37</fpage>
<lpage>44</lpage>
<history>
<date date-type="received">
<day>16</day>
<month>8</month>
<year>2011</year>
</date>
<date date-type="accepted">
<day>17</day>
<month>1</month>
<year>2012</year>
</date>
</history>
<permissions>
<copyright-statement>© Indian Prosthodontic Society 2012</copyright-statement>
</permissions>
<abstract id="Abs1">
<p>Today implant dentistry has made great inroads into the treatment modalities that are available in treating an edentulous patient. Popularity of a two implant retained overdenture has created a necessity to examine the various attachment systems being used and the stresses that are transmitted to the alveolar bone. Hence a Three dimensional Finite Element Analysis was done to analyze the stress distribution in the mandibular bone with implant-supported overdenture having Ball/O-ring and Magnet attachments of different diameters. A segment of the anterior region of the mandible was modeled with implant and the overdenture. Four different models were generated having Ball/O-Ring and Magnet Attachments. Forces of 10 N, 35 N and 70 N were applied from the horizontal, vertical and oblique directions respectively and the stress distribution studied. It was concluded that the greatest stress concentrations were seen at the crest of the cortical bone and could be reduced by using smaller sized attachments for implant supported-overdenture.</p>
</abstract>
<kwd-group>
<title>Keywords</title>
<kwd>Implant</kwd>
<kwd>Overdenture</kwd>
<kwd>Finite element analysis</kwd>
<kwd>Mandibular</kwd>
</kwd-group>
<custom-meta-group>
<custom-meta>
<meta-name>issue-copyright-statement</meta-name>
<meta-value>© Indian Prosthodontic Society 2012</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000A66 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd -nk 000A66 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:3332316
   |texte=   A Finite Element Analysis of Stress Distribution in the Bone, Around the Implant Supporting a Mandibular Overdenture with Ball/O Ring and Magnetic Attachment
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Curation/RBID.i   -Sk "pubmed:23450217" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022