Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Force Finishing and Centering to Balance a Removable Complete Denture Prosthesis Using the T-Scan III Computerized Occlusal Analysis System

Identifieur interne : 000A24 ( Pmc/Curation ); précédent : 000A23; suivant : 000A25

Force Finishing and Centering to Balance a Removable Complete Denture Prosthesis Using the T-Scan III Computerized Occlusal Analysis System

Auteurs : Robert B. Kerstein [États-Unis] ; Prafulla Thumati [Inde] ; S. Padmaja [Inde]

Source :

RBID : PMC:3732729

Abstract

Obtaining bilateral balance of removable complete denture prostheses is the occlusal goal of the restorative dentist or prosthodontist. Despite our best clinical efforts, and the using of advanced mechanical devices like semi-adjustable articulators and face bow transfer mounting of dental casts, it is a struggle to provide accurate occlusal force balance. Some of the advocated reasons for the clinical difficulty of obtaining reliable occlusal balance are that stone casts lack soft tissue resiliency, and articulators only approximate human occlusal functional movements. However, modern technology offers clinicians a digital answer to this clinical force balance problem. It is known as computerized occlusal analysis. The T-Scan III system can be employed with complete removable denture prostheses to perform computer-guided occlusal force-finishing corrective adjustments that measurably improve the installed prosthetic occlusal balance.


Url:
DOI: 10.1007/s13191-013-0287-1
PubMed: 24431732
PubMed Central: 3732729

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:3732729

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Force Finishing and Centering to Balance a Removable Complete Denture Prosthesis Using the T-Scan III Computerized Occlusal Analysis System</title>
<author>
<name sortKey="Kerstein, Robert B" sort="Kerstein, Robert B" uniqKey="Kerstein R" first="Robert B." last="Kerstein">Robert B. Kerstein</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff1">Department of Restorative Dentistry, Tufts University School of Dental Medicine, Boston, MA USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Massachusetts</region>
</placeName>
<wicri:cityArea>Department of Restorative Dentistry, Tufts University School of Dental Medicine, Boston</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Thumati, Prafulla" sort="Thumati, Prafulla" uniqKey="Thumati P" first="Prafulla" last="Thumati">Prafulla Thumati</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff2">Department of Prosthodontics, Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Kumarswamy Layout, Bangalore, 560078 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Kumarswamy Layout, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Padmaja, S" sort="Padmaja, S" uniqKey="Padmaja S" first="S." last="Padmaja">S. Padmaja</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff3">Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Bangalore, India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Bangalore</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">24431732</idno>
<idno type="pmc">3732729</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732729</idno>
<idno type="RBID">PMC:3732729</idno>
<idno type="doi">10.1007/s13191-013-0287-1</idno>
<date when="2013">2013</date>
<idno type="wicri:Area/Pmc/Corpus">000A24</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000A24</idno>
<idno type="wicri:Area/Pmc/Curation">000A24</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000A24</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Force Finishing and Centering to Balance a Removable Complete Denture Prosthesis Using the T-Scan III Computerized Occlusal Analysis System</title>
<author>
<name sortKey="Kerstein, Robert B" sort="Kerstein, Robert B" uniqKey="Kerstein R" first="Robert B." last="Kerstein">Robert B. Kerstein</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff1">Department of Restorative Dentistry, Tufts University School of Dental Medicine, Boston, MA USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Massachusetts</region>
</placeName>
<wicri:cityArea>Department of Restorative Dentistry, Tufts University School of Dental Medicine, Boston</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Thumati, Prafulla" sort="Thumati, Prafulla" uniqKey="Thumati P" first="Prafulla" last="Thumati">Prafulla Thumati</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff2">Department of Prosthodontics, Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Kumarswamy Layout, Bangalore, 560078 India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Kumarswamy Layout, Bangalore</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Padmaja, S" sort="Padmaja, S" uniqKey="Padmaja S" first="S." last="Padmaja">S. Padmaja</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff3">Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Bangalore, India</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Bangalore</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The Journal of the Indian Prosthodontic Society</title>
<idno type="ISSN">0972-4052</idno>
<idno type="eISSN">1998-4057</idno>
<imprint>
<date when="2013">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>Obtaining bilateral balance of removable complete denture prostheses is the occlusal goal of the restorative dentist or prosthodontist. Despite our best clinical efforts, and the using of advanced mechanical devices like semi-adjustable articulators and face bow transfer mounting of dental casts, it is a struggle to provide accurate occlusal force balance. Some of the advocated reasons for the clinical difficulty of obtaining reliable occlusal balance are that stone casts lack soft tissue resiliency, and articulators only approximate human occlusal functional movements. However, modern technology offers clinicians a digital answer to this clinical force balance problem. It is known as computerized occlusal analysis. The T-Scan III system can be employed with complete removable denture prostheses to perform computer-guided occlusal force-finishing corrective adjustments that measurably improve the installed prosthetic occlusal balance.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Indian Prosthodont Soc</journal-id>
<journal-id journal-id-type="iso-abbrev">J Indian Prosthodont Soc</journal-id>
<journal-title-group>
<journal-title>The Journal of the Indian Prosthodontic Society</journal-title>
</journal-title-group>
<issn pub-type="ppub">0972-4052</issn>
<issn pub-type="epub">1998-4057</issn>
<publisher>
<publisher-name>Springer India</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">24431732</article-id>
<article-id pub-id-type="pmc">3732729</article-id>
<article-id pub-id-type="publisher-id">287</article-id>
<article-id pub-id-type="doi">10.1007/s13191-013-0287-1</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Force Finishing and Centering to Balance a Removable Complete Denture Prosthesis Using the T-Scan III Computerized Occlusal Analysis System</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Kerstein</surname>
<given-names>Robert B.</given-names>
</name>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Thumati</surname>
<given-names>Prafulla</given-names>
</name>
<address>
<phone>+9845203217</phone>
<fax>+08026663654</fax>
<email>thumatiprafulla@gmail.com</email>
</address>
<xref ref-type="aff" rid="Aff2"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Padmaja</surname>
<given-names>S.</given-names>
</name>
<xref ref-type="aff" rid="Aff3"></xref>
</contrib>
<aff id="Aff1">
<label></label>
Department of Restorative Dentistry, Tufts University School of Dental Medicine, Boston, MA USA</aff>
<aff id="Aff2">
<label></label>
Department of Prosthodontics, Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Kumarswamy Layout, Bangalore, 560078 India</aff>
<aff id="Aff3">
<label></label>
Dayananda Sagar Dental College and Research Center, Rajiv Gandhi University of Health Sciences, Bangalore, India</aff>
</contrib-group>
<pub-date pub-type="epub">
<day>25</day>
<month>4</month>
<year>2013</year>
</pub-date>
<pub-date pub-type="ppub">
<month>9</month>
<year>2013</year>
</pub-date>
<volume>13</volume>
<issue>3</issue>
<fpage>184</fpage>
<lpage>188</lpage>
<history>
<date date-type="received">
<day>9</day>
<month>1</month>
<year>2013</year>
</date>
<date date-type="accepted">
<day>14</day>
<month>4</month>
<year>2013</year>
</date>
</history>
<permissions>
<copyright-statement>© Indian Prosthodontic Society 2013</copyright-statement>
</permissions>
<abstract id="Abs1">
<p>Obtaining bilateral balance of removable complete denture prostheses is the occlusal goal of the restorative dentist or prosthodontist. Despite our best clinical efforts, and the using of advanced mechanical devices like semi-adjustable articulators and face bow transfer mounting of dental casts, it is a struggle to provide accurate occlusal force balance. Some of the advocated reasons for the clinical difficulty of obtaining reliable occlusal balance are that stone casts lack soft tissue resiliency, and articulators only approximate human occlusal functional movements. However, modern technology offers clinicians a digital answer to this clinical force balance problem. It is known as computerized occlusal analysis. The T-Scan III system can be employed with complete removable denture prostheses to perform computer-guided occlusal force-finishing corrective adjustments that measurably improve the installed prosthetic occlusal balance.</p>
</abstract>
<kwd-group xml:lang="en">
<title>Keywords</title>
<kwd>Measurable occlusal balance</kwd>
<kwd>T-Scan III computerized occlusal analysis system</kwd>
<kwd>Force-finishing</kwd>
<kwd>Force centering</kwd>
</kwd-group>
<custom-meta-group>
<custom-meta>
<meta-name>issue-copyright-statement</meta-name>
<meta-value>© Indian Prosthodontic Society 2013</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000A24 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd -nk 000A24 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:3732729
   |texte=   Force Finishing and Centering to Balance a Removable Complete Denture Prosthesis Using the T-Scan III Computerized Occlusal Analysis System
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Curation/RBID.i   -Sk "pubmed:24431732" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022