Fabricating a Mandibular Implant Supported Overdenture with a Suspended Framework

Identifieur interne : 000919 ( Pmc/Curation ); précédent : 000918; suivant : 000920

Fabricating a Mandibular Implant Supported Overdenture with a Suspended Framework

Auteurs : Swati Ahuja [États-Unis] ; Vinay Jain [États-Unis] ; David Cagna [États-Unis] ; Russell Wicks [États-Unis]

Source :

RBID : PMC:3634938

Abstract

The introduction of implant-supported overdentures as a clinical alternative has improved the quality of life of the edentulous population. Implant-supported overdentures have diminished many of the problems associated with conventional dentures by providing improved retention, stability, function, esthetics and physical and emotional health. Greater support and stability of the implant borne prosthesis is associated with improved bite force and oral function for overdentures when compared to conventional complete dentures. An adequate amount of restorative space is required when fabricating implant-supported overdentures. This space must accommodate a denture base of sufficient dimensions, appropriately positioned denture teeth, and an implant attachment system. Insufficient space may lead to reduced structural integrity of the prosthesis and/or compromised oral function. Typically a mandibular removable prosthesis is more vulnerable to fracture due to its shape and overall dimensions. Incorporation of a metal framework, metal reinforcing mesh, or woven or fiberglass-impregnated mesh have been recommended to improve resistance to denture fracture during function. This article presents a method for fabricating a framework that is specifically and predictably suspended within the denture base in order to decrease fracture susceptibility of implant-supported overdentures.


Url:
DOI: 10.1007/s13191-012-0196-8
PubMed: 24431723
PubMed Central: 3634938

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:3634938

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Fabricating a Mandibular Implant Supported Overdenture with a Suspended Framework</title>
<author>
<name sortKey="Ahuja, Swati" sort="Ahuja, Swati" uniqKey="Ahuja S" first="Swati" last="Ahuja">Swati Ahuja</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff1">Department of Prosthodontics, UTHSC College of Dentistry, C-515, 875 Union Ave, Memphis, TN 38163 USA</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>Department of Prosthodontics, UTHSC College of Dentistry, C-515, 875 Union Ave, Memphis</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Jain, Vinay" sort="Jain, Vinay" uniqKey="Jain V" first="Vinay" last="Jain">Vinay Jain</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff2">Department of Prosthodontics, University of Tennessee, Health Science Center, College of Dentistry, Memphis, TN USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>Department of Prosthodontics, University of Tennessee, Health Science Center, College of Dentistry, Memphis</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Cagna, David" sort="Cagna, David" uniqKey="Cagna D" first="David" last="Cagna">David Cagna</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff3">College of Dentistry, University of Tennessee Health Science Center, Memphis, TN USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>College of Dentistry, University of Tennessee Health Science Center, Memphis</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Wicks, Russell" sort="Wicks, Russell" uniqKey="Wicks R" first="Russell" last="Wicks">Russell Wicks</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff4">Department of Prosthodontics, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>Department of Prosthodontics, University of Tennessee Health Science Center, College of Dentistry, Memphis</wicri:cityArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">24431723</idno>
<idno type="pmc">3634938</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3634938</idno>
<idno type="RBID">PMC:3634938</idno>
<idno type="doi">10.1007/s13191-012-0196-8</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">000919</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000919</idno>
<idno type="wicri:Area/Pmc/Curation">000919</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000919</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Fabricating a Mandibular Implant Supported Overdenture with a Suspended Framework</title>
<author>
<name sortKey="Ahuja, Swati" sort="Ahuja, Swati" uniqKey="Ahuja S" first="Swati" last="Ahuja">Swati Ahuja</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff1">Department of Prosthodontics, UTHSC College of Dentistry, C-515, 875 Union Ave, Memphis, TN 38163 USA</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>Department of Prosthodontics, UTHSC College of Dentistry, C-515, 875 Union Ave, Memphis</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Jain, Vinay" sort="Jain, Vinay" uniqKey="Jain V" first="Vinay" last="Jain">Vinay Jain</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff2">Department of Prosthodontics, University of Tennessee, Health Science Center, College of Dentistry, Memphis, TN USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>Department of Prosthodontics, University of Tennessee, Health Science Center, College of Dentistry, Memphis</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Cagna, David" sort="Cagna, David" uniqKey="Cagna D" first="David" last="Cagna">David Cagna</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff3">College of Dentistry, University of Tennessee Health Science Center, Memphis, TN USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>College of Dentistry, University of Tennessee Health Science Center, Memphis</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Wicks, Russell" sort="Wicks, Russell" uniqKey="Wicks R" first="Russell" last="Wicks">Russell Wicks</name>
<affiliation wicri:level="2">
<nlm:aff id="Aff4">Department of Prosthodontics, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN USA</nlm:aff>
<country>États-Unis</country>
<placeName>
<region type="state">Tennessee</region>
</placeName>
<wicri:cityArea>Department of Prosthodontics, University of Tennessee Health Science Center, College of Dentistry, Memphis</wicri:cityArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The Journal of the Indian Prosthodontic Society</title>
<idno type="ISSN">0972-4052</idno>
<idno type="eISSN">1998-4057</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>The introduction of implant-supported overdentures as a clinical alternative has improved the quality of life of the edentulous population. Implant-supported overdentures have diminished many of the problems associated with conventional dentures by providing improved retention, stability, function, esthetics and physical and emotional health. Greater support and stability of the implant borne prosthesis is associated with improved bite force and oral function for overdentures when compared to conventional complete dentures. An adequate amount of restorative space is required when fabricating implant-supported overdentures. This space must accommodate a denture base of sufficient dimensions, appropriately positioned denture teeth, and an implant attachment system. Insufficient space may lead to reduced structural integrity of the prosthesis and/or compromised oral function. Typically a mandibular removable prosthesis is more vulnerable to fracture due to its shape and overall dimensions. Incorporation of a metal framework, metal reinforcing mesh, or woven or fiberglass-impregnated mesh have been recommended to improve resistance to denture fracture during function. This article presents a method for fabricating a framework that is specifically and predictably suspended within the denture base in order to decrease fracture susceptibility of implant-supported overdentures.</p>
</div>
</front>
</TEI>
<pmc article-type="case-report">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Indian Prosthodont Soc</journal-id>
<journal-id journal-id-type="iso-abbrev">J Indian Prosthodont Soc</journal-id>
<journal-title-group>
<journal-title>The Journal of the Indian Prosthodontic Society</journal-title>
</journal-title-group>
<issn pub-type="ppub">0972-4052</issn>
<issn pub-type="epub">1998-4057</issn>
<publisher>
<publisher-name>Springer-Verlag</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">24431723</article-id>
<article-id pub-id-type="pmc">3634938</article-id>
<article-id pub-id-type="publisher-id">196</article-id>
<article-id pub-id-type="doi">10.1007/s13191-012-0196-8</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Clinical Report</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Fabricating a Mandibular Implant Supported Overdenture with a Suspended Framework</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Ahuja</surname>
<given-names>Swati</given-names>
</name>
<address>
<fax>+901-448-1294</fax>
<email>sahuja@uthsc.edu</email>
</address>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Jain</surname>
<given-names>Vinay</given-names>
</name>
<xref ref-type="aff" rid="Aff2"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Cagna</surname>
<given-names>David</given-names>
</name>
<xref ref-type="aff" rid="Aff3"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wicks</surname>
<given-names>Russell</given-names>
</name>
<xref ref-type="aff" rid="Aff4"></xref>
</contrib>
<aff id="Aff1">
<label></label>
Department of Prosthodontics, UTHSC College of Dentistry, C-515, 875 Union Ave, Memphis, TN 38163 USA</aff>
<aff id="Aff2">
<label></label>
Department of Prosthodontics, University of Tennessee, Health Science Center, College of Dentistry, Memphis, TN USA</aff>
<aff id="Aff3">
<label></label>
College of Dentistry, University of Tennessee Health Science Center, Memphis, TN USA</aff>
<aff id="Aff4">
<label></label>
Department of Prosthodontics, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN USA</aff>
</contrib-group>
<pub-date pub-type="epub">
<day>19</day>
<month>10</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="ppub">
<month>6</month>
<year>2013</year>
</pub-date>
<volume>13</volume>
<issue>2</issue>
<fpage>132</fpage>
<lpage>136</lpage>
<history>
<date date-type="received">
<day>16</day>
<month>5</month>
<year>2012</year>
</date>
<date date-type="accepted">
<day>10</day>
<month>10</month>
<year>2012</year>
</date>
</history>
<permissions>
<copyright-statement>© Indian Prosthodontic Society 2012</copyright-statement>
</permissions>
<abstract id="Abs1">
<p>The introduction of implant-supported overdentures as a clinical alternative has improved the quality of life of the edentulous population. Implant-supported overdentures have diminished many of the problems associated with conventional dentures by providing improved retention, stability, function, esthetics and physical and emotional health. Greater support and stability of the implant borne prosthesis is associated with improved bite force and oral function for overdentures when compared to conventional complete dentures. An adequate amount of restorative space is required when fabricating implant-supported overdentures. This space must accommodate a denture base of sufficient dimensions, appropriately positioned denture teeth, and an implant attachment system. Insufficient space may lead to reduced structural integrity of the prosthesis and/or compromised oral function. Typically a mandibular removable prosthesis is more vulnerable to fracture due to its shape and overall dimensions. Incorporation of a metal framework, metal reinforcing mesh, or woven or fiberglass-impregnated mesh have been recommended to improve resistance to denture fracture during function. This article presents a method for fabricating a framework that is specifically and predictably suspended within the denture base in order to decrease fracture susceptibility of implant-supported overdentures.</p>
</abstract>
<kwd-group xml:lang="en">
<title>Keywords</title>
<kwd>Implant</kwd>
<kwd>Denture</kwd>
<kwd>Overdenture</kwd>
<kwd>Framework</kwd>
<kwd>Fracture</kwd>
</kwd-group>
<custom-meta-group>
<custom-meta>
<meta-name>issue-copyright-statement</meta-name>
<meta-value>© Indian Prosthodontic Society 2013</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000919 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd -nk 000919 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:3634938
   |texte=   Fabricating a Mandibular Implant Supported Overdenture with a Suspended Framework
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Curation/RBID.i   -Sk "pubmed:24431723" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022