Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures

Identifieur interne : 003083 ( Pmc/Corpus ); précédent : 003082; suivant : 003084

The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures

Auteurs : Farhad Tabatabaian ; Abolfazl Saboury ; Zahra Sadat Sobhani ; Vicki C. Petropoulos

Source :

RBID : PMC:4290769

Abstract

Objectives:

The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments.

Materials and Methods:

An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance.

Results:

Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05).

Conclusion:

Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance.


Url:
PubMed: 25628676
PubMed Central: 4290769

Links to Exploration step

PMC:4290769

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures</title>
<author>
<name sortKey="Tabatabaian, Farhad" sort="Tabatabaian, Farhad" uniqKey="Tabatabaian F" first="Farhad" last="Tabatabaian">Farhad Tabatabaian</name>
<affiliation>
<nlm:aff id="af1-jod-11-506"> Assistant Professor, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Saboury, Abolfazl" sort="Saboury, Abolfazl" uniqKey="Saboury A" first="Abolfazl" last="Saboury">Abolfazl Saboury</name>
<affiliation>
<nlm:aff id="af2-jod-11-506"> Associate Professor, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Sobhani, Zahra Sadat" sort="Sobhani, Zahra Sadat" uniqKey="Sobhani Z" first="Zahra Sadat" last="Sobhani">Zahra Sadat Sobhani</name>
<affiliation>
<nlm:aff id="af3-jod-11-506"> Former Student, Dental School of Shahid Beheshti University of Medical Sciences, Tehran, Iran</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Petropoulos, Vicki C" sort="Petropoulos, Vicki C" uniqKey="Petropoulos V" first="Vicki C" last="Petropoulos">Vicki C. Petropoulos</name>
<affiliation>
<nlm:aff id="af4-jod-11-506"> Associate Professor, Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, United States</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">25628676</idno>
<idno type="pmc">4290769</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4290769</idno>
<idno type="RBID">PMC:4290769</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">003083</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">003083</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures</title>
<author>
<name sortKey="Tabatabaian, Farhad" sort="Tabatabaian, Farhad" uniqKey="Tabatabaian F" first="Farhad" last="Tabatabaian">Farhad Tabatabaian</name>
<affiliation>
<nlm:aff id="af1-jod-11-506"> Assistant Professor, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Saboury, Abolfazl" sort="Saboury, Abolfazl" uniqKey="Saboury A" first="Abolfazl" last="Saboury">Abolfazl Saboury</name>
<affiliation>
<nlm:aff id="af2-jod-11-506"> Associate Professor, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Sobhani, Zahra Sadat" sort="Sobhani, Zahra Sadat" uniqKey="Sobhani Z" first="Zahra Sadat" last="Sobhani">Zahra Sadat Sobhani</name>
<affiliation>
<nlm:aff id="af3-jod-11-506"> Former Student, Dental School of Shahid Beheshti University of Medical Sciences, Tehran, Iran</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Petropoulos, Vicki C" sort="Petropoulos, Vicki C" uniqKey="Petropoulos V" first="Vicki C" last="Petropoulos">Vicki C. Petropoulos</name>
<affiliation>
<nlm:aff id="af4-jod-11-506"> Associate Professor, Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, United States</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of Dentistry (Tehran, Iran)</title>
<idno type="ISSN">1735-2150</idno>
<idno type="eISSN">2008-2185</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Objectives:</title>
<p>The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments.</p>
</sec>
<sec>
<title>Materials and Methods:</title>
<p>An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance.</p>
</sec>
<sec>
<title>Results:</title>
<p>Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05).</p>
</sec>
<sec>
<title>Conclusion:</title>
<p>Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Feine, Js" uniqKey="Feine J">JS Feine</name>
</author>
<author>
<name sortKey="Carlsson, Ge" uniqKey="Carlsson G">GE Carlsson</name>
</author>
<author>
<name sortKey="Awad, Ma" uniqKey="Awad M">MA Awad</name>
</author>
<author>
<name sortKey="Chehade, A" uniqKey="Chehade A">A Chehade</name>
</author>
<author>
<name sortKey="Duncan, Wj" uniqKey="Duncan W">WJ Duncan</name>
</author>
<author>
<name sortKey="Gizani, S" uniqKey="Gizani S">S Gizani</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mentag, P" uniqKey="Mentag P">P Mentag</name>
</author>
<author>
<name sortKey="Kosinski, T" uniqKey="Kosinski T">T Kosinski</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Trushkowsky, Rd" uniqKey="Trushkowsky R">RD Trushkowsky</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Zitsmann, Nu" uniqKey="Zitsmann N">NU Zitsmann</name>
</author>
<author>
<name sortKey="Marinello, Cp" uniqKey="Marinello C">CP Marinello</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Petropoulos, Vc" uniqKey="Petropoulos V">VC Petropoulos</name>
</author>
<author>
<name sortKey="Mante, Fk" uniqKey="Mante F">FK Mante</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Naert, I" uniqKey="Naert I">I Naert</name>
</author>
<author>
<name sortKey="Quirynen, M" uniqKey="Quirynen M">M Quirynen</name>
</author>
<author>
<name sortKey="Theuniers, G" uniqKey="Theuniers G">G Theuniers</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" uniqKey="Van Steenberghe D">D van Steenberghe</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Burns, Dr" uniqKey="Burns D">DR Burns</name>
</author>
<author>
<name sortKey="Unger, Jw" uniqKey="Unger J">JW Unger</name>
</author>
<author>
<name sortKey="Elswick, Rk" uniqKey="Elswick R">RK Elswick</name>
</author>
<author>
<name sortKey="Beck, Da" uniqKey="Beck D">DA Beck</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Burns, Dr" uniqKey="Burns D">DR Burns</name>
</author>
<author>
<name sortKey="Unger, Jw" uniqKey="Unger J">JW Unger</name>
</author>
<author>
<name sortKey="Elswick, Rk" uniqKey="Elswick R">RK Elswick</name>
</author>
<author>
<name sortKey="Giglio, Ja" uniqKey="Giglio J">JA Giglio</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tabatabaian, F" uniqKey="Tabatabaian F">F Tabatabaian</name>
</author>
<author>
<name sortKey="Alaie, F" uniqKey="Alaie F">F Alaie</name>
</author>
<author>
<name sortKey="Seyedan, K" uniqKey="Seyedan K">K Seyedan</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Petropoulos, Vc" uniqKey="Petropoulos V">VC Petropoulos</name>
</author>
<author>
<name sortKey="Smith, W" uniqKey="Smith W">W Smith</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rutkunas, V" uniqKey="Rutkunas V">V Rutkunas</name>
</author>
<author>
<name sortKey="Mizutani, H" uniqKey="Mizutani H">H Mizutani</name>
</author>
<author>
<name sortKey="Takahashi, H" uniqKey="Takahashi H">H Takahashi</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gamborena, Ji" uniqKey="Gamborena J">JI Gamborena</name>
</author>
<author>
<name sortKey="Hazelton, Lr" uniqKey="Hazelton L">LR Hazelton</name>
</author>
<author>
<name sortKey="Nabadalung, D" uniqKey="Nabadalung D">D NaBadalung</name>
</author>
<author>
<name sortKey="Brudvik, J" uniqKey="Brudvik J">J Brudvik</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gulizio, Mp" uniqKey="Gulizio M">MP Gulizio</name>
</author>
<author>
<name sortKey="Agar, Jr" uniqKey="Agar J">JR Agar</name>
</author>
<author>
<name sortKey="Kelly, Jr" uniqKey="Kelly J">JR Kelly</name>
</author>
<author>
<name sortKey="Taylor, Td" uniqKey="Taylor T">TD Taylor</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Van Kampen, F" uniqKey="Van Kampen F">F Van Kampen</name>
</author>
<author>
<name sortKey="Cune, M" uniqKey="Cune M">M Cune</name>
</author>
<author>
<name sortKey="Van Der Bilt, A" uniqKey="Van Der Bilt A">A van der Bilt</name>
</author>
<author>
<name sortKey="Bosman, F" uniqKey="Bosman F">F Bosman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Petropoulos, Vc" uniqKey="Petropoulos V">VC Petropoulos</name>
</author>
<author>
<name sortKey="Smith, W" uniqKey="Smith W">W Smith</name>
</author>
<author>
<name sortKey="Kousvelari, E" uniqKey="Kousvelari E">E Kousvelari</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Greenstein, G" uniqKey="Greenstein G">G Greenstein</name>
</author>
<author>
<name sortKey="Tarnow, D" uniqKey="Tarnow D">D Tarnow</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Michelinakis, G" uniqKey="Michelinakis G">G Michelinakis</name>
</author>
<author>
<name sortKey="Barclay, Cw" uniqKey="Barclay C">CW Barclay</name>
</author>
<author>
<name sortKey="Smith, Pw" uniqKey="Smith P">PW Smith</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Doukas, D" uniqKey="Doukas D">D Doukas</name>
</author>
<author>
<name sortKey="Michelinakis, G" uniqKey="Michelinakis G">G Michelinakis</name>
</author>
<author>
<name sortKey="Smith, Pw" uniqKey="Smith P">PW Smith</name>
</author>
<author>
<name sortKey="Barclay, Cw" uniqKey="Barclay C">CW Barclay</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Alsabeeha, Nh" uniqKey="Alsabeeha N">NH Alsabeeha</name>
</author>
<author>
<name sortKey="Payne, Ag" uniqKey="Payne A">AG Payne</name>
</author>
<author>
<name sortKey="Swain, Mv" uniqKey="Swain M">MV Swain</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tokuhisa, M" uniqKey="Tokuhisa M">M Tokuhisa</name>
</author>
<author>
<name sortKey="Matsushita, Y" uniqKey="Matsushita Y">Y Matsushita</name>
</author>
<author>
<name sortKey="Koyano, K" uniqKey="Koyano K">K Koyano</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sarnat, Ae" uniqKey="Sarnat A">AE Sarnat</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Daniel, Ww" uniqKey="Daniel W">WW Daniel</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Halliday, D" uniqKey="Halliday D">D Halliday</name>
</author>
<author>
<name sortKey="Resnick, R" uniqKey="Resnick R">R Resnick</name>
</author>
<author>
<name sortKey="Walker, J" uniqKey="Walker J">J Walker</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Setz, I" uniqKey="Setz I">I Setz</name>
</author>
<author>
<name sortKey="Lee, Sh" uniqKey="Lee S">SH Lee</name>
</author>
<author>
<name sortKey="Engle, E" uniqKey="Engle E">E Engle</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Botega, Dm" uniqKey="Botega D">DM Botega</name>
</author>
<author>
<name sortKey="Mesquita, Mf" uniqKey="Mesquita M">MF Mesquita</name>
</author>
<author>
<name sortKey="Henriques, Ge" uniqKey="Henriques G">GE Henriques</name>
</author>
<author>
<name sortKey="Vaz, Lg" uniqKey="Vaz L">LG Vaz</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Dent (Tehran)</journal-id>
<journal-id journal-id-type="iso-abbrev">J Dent (Tehran)</journal-id>
<journal-title-group>
<journal-title>Journal of Dentistry (Tehran, Iran)</journal-title>
</journal-title-group>
<issn pub-type="ppub">1735-2150</issn>
<issn pub-type="epub">2008-2185</issn>
<publisher>
<publisher-name>Tehran University of Medical Sciences</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">25628676</article-id>
<article-id pub-id-type="pmc">4290769</article-id>
<article-id pub-id-type="publisher-id">jod-11-506</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Tabatabaian</surname>
<given-names>Farhad</given-names>
</name>
<xref ref-type="aff" rid="af1-jod-11-506">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c1-jod-11-506"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Saboury</surname>
<given-names>Abolfazl</given-names>
</name>
<xref ref-type="aff" rid="af2-jod-11-506">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sobhani</surname>
<given-names>Zahra Sadat</given-names>
</name>
<xref ref-type="aff" rid="af3-jod-11-506">
<sup>3</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Petropoulos</surname>
<given-names>Vicki C</given-names>
</name>
<xref ref-type="aff" rid="af4-jod-11-506">
<sup>4</sup>
</xref>
</contrib>
</contrib-group>
<aff id="af1-jod-11-506">
<label>1</label>
Assistant Professor, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran</aff>
<aff id="af2-jod-11-506">
<label>2</label>
Associate Professor, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran</aff>
<aff id="af3-jod-11-506">
<label>3</label>
Former Student, Dental School of Shahid Beheshti University of Medical Sciences, Tehran, Iran</aff>
<aff id="af4-jod-11-506">
<label>4</label>
Associate Professor, Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, United States</aff>
<author-notes>
<corresp id="c1-jod-11-506">Corresponding author: F. Tabatabaian, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran,
<email>f_tabatabaian@yahoo.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<month>9</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>30</day>
<month>9</month>
<year>2014</year>
</pub-date>
<volume>11</volume>
<issue>5</issue>
<fpage>506</fpage>
<lpage>515</lpage>
<history>
<date date-type="received">
<day>28</day>
<month>3</month>
<year>2014</year>
</date>
<date date-type="accepted">
<day>23</day>
<month>7</month>
<year>2014</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright © Dental Research Center, Tehran University of Medical Sciences</copyright-statement>
<copyright-year>2014</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">
<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.</license-p>
</license>
</permissions>
<abstract>
<sec>
<title>Objectives:</title>
<p>The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments.</p>
</sec>
<sec>
<title>Materials and Methods:</title>
<p>An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance.</p>
</sec>
<sec>
<title>Results:</title>
<p>Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05).</p>
</sec>
<sec>
<title>Conclusion:</title>
<p>Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Dental Implant</kwd>
<kwd>Overdenture</kwd>
<kwd>Dental Prosthesis Retention</kwd>
<kwd>Implant-Supported Dental Prosthesis</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec sec-type="intro">
<title>INTRODUCTION</title>
<p>The mandibular implant-tissue-supported overdenture (MITSO) using two implants is the first choice standard of care for the edentulous mandible, especially when finances prohibit more implants to be placed [
<xref rid="b1-jod-11-506" ref-type="bibr">1</xref>
].</p>
<p>Complete dentures are replaced by implant-tissue-supported overdentures by placing two implants and using attachments. Some of the information for the selection of attachments is derived from clinical experience [
<xref rid="b2-jod-11-506" ref-type="bibr">2</xref>
,
<xref rid="b3-jod-11-506" ref-type="bibr">3</xref>
].</p>
<p>The overdenture must be carefully designed to achieve adequate stability, optimal form, contour, esthetics, and the patient’s best comfort [
<xref rid="b4-jod-11-506" ref-type="bibr">4</xref>
]. Stud-type attachments are the most commonly used among different types of attachments [
<xref rid="b5-jod-11-506" ref-type="bibr">5</xref>
]. There are many factors for the selection of attachment systems including the amount of space available, maintenance requirements, load distribution to the mucosa and implants, and the level of retention and resistance desired. Retention is defined as the capacity of the prosthesis to oppose with vertical forces, while resistance is defined as the capacity to oppose with forces other than vertical forces, including oblique and anterior-posterior forces. The retention and resistance of the MITSO play significant roles in resuming function and patient satisfaction [
<xref rid="b6-jod-11-506" ref-type="bibr">6</xref>
<xref rid="b8-jod-11-506" ref-type="bibr">8</xref>
].</p>
<p>Retention and resistance are influenced by the type of attachment and the design [
<xref rid="b9-jod-11-506" ref-type="bibr">9</xref>
,
<xref rid="b10-jod-11-506" ref-type="bibr">10</xref>
]. The wear of components [
<xref rid="b11-jod-11-506" ref-type="bibr">11</xref>
,
<xref rid="b12-jod-11-506" ref-type="bibr">12</xref>
] and implant angulation [
<xref rid="b13-jod-11-506" ref-type="bibr">13</xref>
] can affect the retention. Van Kampen [
<xref rid="b14-jod-11-506" ref-type="bibr">14</xref>
], Petropoulos [
<xref rid="b5-jod-11-506" ref-type="bibr">5</xref>
,
<xref rid="b10-jod-11-506" ref-type="bibr">10</xref>
,
<xref rid="b15-jod-11-506" ref-type="bibr">15</xref>
], and Tabatabaian [
<xref rid="b9-jod-11-506" ref-type="bibr">9</xref>
] in separate studies have evaluated retention and resistance with different attachments while the implants were inserted at the symphyseal region .</p>
<p>When placing two implants for a MITSO, the implants are traditionally located between the mental foramina [
<xref rid="b16-jod-11-506" ref-type="bibr">16</xref>
]; therefore, another factor that may be considered is the inter-implant distance, which is the distance between the two implants. To the best our knowledge, a few studies have evaluated the effect of inter-implant distance on retention, while the effect of this factor on resistance has not been assessed. Michelinakis [
<xref rid="b17-jod-11-506" ref-type="bibr">17</xref>
] and Doukas [
<xref rid="b18-jod-11-506" ref-type="bibr">18</xref>
] found that the inter-implant distance can affect the retention of MITSO depending on the type of attachment used. Alsabeeha [
<xref rid="b19-jod-11-506" ref-type="bibr">19</xref>
] found the need for further studies on factors affecting retention for MITSOs and emphasized that these factors must be studied separately under well-controlled conditions. The impact of inter-implant distance on the retention and resistance of MITSOs is lacking in the literature.</p>
<p>Tokuhisa [
<xref rid="b20-jod-11-506" ref-type="bibr">20</xref>
] has reported that ball attachment is commonly used and it optimizes load transmission while minimizing overdenture movement. Therefore, the purpose of this in vitro investigation was to assess the effect of inter-implant distance on the retention and resistance of MITSOs. The null hypothesis of this study was that the inter-implant distance would not affect the retention and resistance of a MITSO retained by two ball attachments when tensile dislodging forces were applied.</p>
</sec>
<sec sec-type="materials|methods">
<title>MATERIALS AND METHODS</title>
<p>This in vitro study was performed on 45 overdenture samples divided into three groups of 15: A, B, and C, each based on the position of implants. Each overdenture sample was tested three times to examine vertically, obliquely and anterior-posteriorly directed tensile dislodging forces. For equal distribution of forces, a hypothetical equilateral triangle with 5 cm sides was created. The three corners and the center of the triangle were used for force transmission (
<xref ref-type="fig" rid="f1-jod-11-506">Figure 1</xref>
).</p>
<sec>
<title>Test cast fabrication</title>
<p>A mandibular acrylic cast was fabricated from a master cast belonging to an edentulous patient with a medium-sized, ovoid arch form. The undercuts were relieved and the borders were extended to match the mentioned design.</p>
<p>The test cast was prepared using clear self-polymerized acrylic resin (Meliodent, Heraeus Kulzer, Senden, Germany) to simulate the mandibular arch.</p>
<p>Three pairs of implants with 4 mm diameter and 12 mm length (PGR4012, BioHorizons, Birmingham, Alabama, USA) were inserted on both sides of the midline symmetrically in parallel positions with inter-implant distances of 10, 25, and 35 millimeters, and at the approximate locations of laterals, canines and first premolars namely positioned as A, B and C, respectively.</p>
<p>In the current study, the inter-implant distance was defined as the straight distance between the centers of the paired implants.</p>
<p>A milling machine (Paraskope M, Bego, Bremen, Germany) was employed to ensure the same correct angulations of all implants. A cast framework, made of a chrome-cobalt alloy (Remanium GM 800+, Dentaurum, Ispringen, Germany), was constructed as a denture base on the posterior region of the ridge and a frame-like structure on the anterior area, encircling all implants.</p>
<p>The anterior part of the framework, where the overdenture housing would be attached, was subjected to a sandblasting unit (Korostar Plus, Bego, Bremen, Germany).</p>
<p>The framework had four hooks: two at the site of first molars on the denture base and the remaining two on the posterior and anterior limits of the frame-like structure (
<xref ref-type="fig" rid="f2-jod-11-506">Figure 2</xref>
). The four hooks were of the same height.</p>
</sec>
<sec>
<title>Overdenture housing fabrication</title>
<p>A prototype was fabricated over the anterior part of the framework on the test cast using light-polymerized custom tray material (Megatray, Megadenta Dentalprodukte, Radeberg, Germany). Three rectangular stop points were formed in its inferior surface. The prototype was placed in a denture duplicating flask, containing C-silicone putty material (Zetaflow Putty, Zermack, Badia Polesine, Italy). After setting of the material, the flask was opened and the prototype was taken out. Clear heat-polymerized acrylic resin (Meliodent, Heraeus Kulzer, Senden, Germany) was poured into the flask in order to prepare an overdenture housing by duplicating the prototype. The flask was submerged in warm water for 60 minutes. Finally, the overdenture housing was fabricated as such and adapted on both the framework and test cast. It was connected to the framework with clear self-polymerized acrylic resin. Thus, the framework and overdenture housing acted as a unit named overdenture.</p>
</sec>
<sec>
<title>Specimen preparation</title>
<p>The ball attachment set (BCAS, BioHorizons, Birmingham, Alabama, USA) with the three following components was used to attach the overdenture to the implants: 1. Ball abutment with 2.5 mm diameter (PGBA1, BioHorizons, Birmingham, Alabama, USA). 2. Attachment housing (BCAHT, BioHorizons, Birmingham, Alabama, USA). 3. Pink nylon insert (BCIP, BioHorizons, Birmingham, Alabama, USA) (
<xref ref-type="fig" rid="f3-jod-11-506">Figure 3</xref>
).</p>
<p>Two ball abutments were screwed onto the implants of position A and torqued to 30 Ncm with a torque wrench (300–430, BioHorizons, Birmingham, Alabama, USA). The complex of attachment housings and pink nylon inserts were placed on the ball abutments in a parallel position adjusted by a dental cast surveyor (Dental Surveyor, Krupp Medizintechnik, Essen, Germany) and fixed in their respective locations. The overdenture housing was perforated over the implant sites. After immobilization of the overdenture on the test cast, the perforations were filled with clear self-polymerized acrylic resin covering the attachment housing edges. This process was done with the same two ball abutments in positions B and C until the six attachment housings were placed within the overdenture housing (
<xref ref-type="fig" rid="f4-jod-11-506">Figure 4</xref>
).</p>
<p>The pink nylon inserts acted as the keyway, while the ball abutments acted as the key. By engaging these components, the overdenture would be retained on the test cast. The three stop points under the overdenture housing and the position of overdenture bases were the references for ensuring the correct seating of the overdenture.</p>
<p>The new and intact pink nylon inserts were allocated, and then were observed by a magnifying glass in order to exclude the impaired ones. For each overdenture sample, only pink nylon inserts were replaced and the other parts were the same among the samples. Obviously, the locations of ball abutments and attachment housings were predetermined relevant to the group of the sample (A, B, and C).</p>
</sec>
<sec>
<title>Testing</title>
<p>A universal testing machine (Zwick Z020, Zwick/Roell, Ulm, Germany) was used to apply and measure tensile dislodging forces.</p>
<p>A metallic S-shaped hook with 15.5 cm length was connected to the horizontal crosshead of the machine. Another hook was used to connect the first hook to the load cell, a circle steel plate with 8 cm diameter.</p>
<p>Four loops were designed on the inferior surface of the load cell corresponding to the hooks on the overdenture. A piece of polyester string (Polyester cord 0.407 mm2, Kian Cord, Malayer, Iran) was used for load transmission from the load cell to the overdenture attached to the test cast, while the test cast was fixed to the inferior platform of the testing machine (
<xref ref-type="fig" rid="f5-jod-11-506">Figure 5</xref>
). The string was passed through the corresponding hooks on the overdenture and loops on the load cell and tied at the end. To measure the peak load for the vertically directed dislodging forces, the string was passed through all hooks. To measure the peak load for the obliquely directed dislodging forces, three hooks were involved (all except one of the posterior hooks); whereas, for anterior-posteriorly directed dislodging forces only the two posterior hooks were involved.</p>
<p>The crosshead speed was adjusted at 51 mm/min, which would approximate the rate of denture movement during mastication [
<xref rid="b21-jod-11-506" ref-type="bibr">21</xref>
]. The peak load was measured and was represented with the peak point load profile curve demonstrated for each test.</p>
<p>Kolmogorov Smirnov test [
<xref rid="b22-jod-11-506" ref-type="bibr">22</xref>
] indicated normal distribution of the data (P>0.05). Therefore, a one-way ANOVA was used to evaluate the peak loads for the vertically, obliquely and anterior-posteriorly directed dislodging forces separately for the three A, B and C groups. In addition, homogeneity of variances showed that the three groups were the same (P>0.05). Thus, Tukey’s HSD test was used for paired comparison of the three groups. The results were reported with a 95% confidence interval.</p>
</sec>
</sec>
<sec sec-type="results">
<title>RESULTS</title>
<p>The peak loads for the vertically directed dislodging forces were measured as 25.03 N±7.47 N, 22.91 N±6.23 N, and 24.50 N±5.83 N for groups A, B, and C, respectively (
<xref ref-type="fig" rid="f6-jod-11-506">Figure 6</xref>
).</p>
<p>There were no statistically significant differences among the three groups (P>0.05). The peak loads for the obliquely directed dislodging forces were 20.92 N±4.39 N, 18.14 N±4.85 N, and 18.76 N±6.32 N for groups A, B, and C, respectively (
<xref ref-type="fig" rid="f7-jod-11-506">Figure 7</xref>
).</p>
<p>No statistically significant differences existed among the three groups (P>0.05).</p>
<p>The peak loads for the anterior-posteriorly dislodging forces were 14.46 N±2.11 N, 14.94 N±3.83 N, and 21.25 N±3.05 N for groups A, B, and C, respectively (
<xref ref-type="fig" rid="f8-jod-11-506">Figure 8</xref>
). There was a statistically significant difference in this respect among the three groups (P<0.05). Considering P<0.05, Tukey’s HSD test was applied for paired comparison of the three different groups.</p>
<p>No statistically significant difference was found between groups A and B (P>0.05), while the peak loads for the anterior-posteriorly dislodging forces were the highest for group C when compared to groups A and B (P<0.05).</p>
</sec>
<sec sec-type="discussion">
<title>DISCUSSION</title>
<p>Retention and resistance of MITSOs depend on various factors including attachment type and design, wear of components, and implant angulation [
<xref rid="b9-jod-11-506" ref-type="bibr">9</xref>
<xref rid="b13-jod-11-506" ref-type="bibr">13</xref>
]. Alsabeeha [
<xref rid="b19-jod-11-506" ref-type="bibr">19</xref>
] in a review of in vitro investigations on MITSOs concluded that effective factors on retention must be investigated separately under well-controlled conditions to limit the influence of confounding variables on the outcome. The current study accessed the effect of inter-implant distance on retention and resistance for a MITSO when subjected to dislodging forces. The MITSOs under function resist to dislodgement in different directions in the mouth. The outcome is a complex three-dimensional movement of the overdenture.</p>
<p>Therefore, to analyze this behavior in in vitro conditions, tensile dislodging forces were divided into simpler elements [
<xref rid="b5-jod-11-506" ref-type="bibr">5</xref>
,
<xref rid="b9-jod-11-506" ref-type="bibr">9</xref>
,
<xref rid="b10-jod-11-506" ref-type="bibr">10</xref>
].</p>
<p>In this study, the overdenture was examined in three principal directions: vertical, oblique and anterior-posterior.</p>
<p>The results of this investigation revealed that there were no significant differences in the peak loads among the three A, B, and C groups (the inter-implant distances of 10, 25, and 35 mm, respectively) with vertically and obliquely directed dislodging forces, while the peak loads with the anterior-posteriorly directed dislodging forces for group C were significantly the highest. Hence, the null hypothesis of the study was partly rejected.</p>
<p>Michelinakis [
<xref rid="b17-jod-11-506" ref-type="bibr">17</xref>
] and Doukas [
<xref rid="b18-jod-11-506" ref-type="bibr">18</xref>
] performed two in vitro studies in which they used the inter-implant distance of 19, 23 and 29 mm, and measured the peak loads in vertical direction. They found that the inter-implant distance played a significant role only in the retention produced by the Hader bar/red [
<xref rid="b17-jod-11-506" ref-type="bibr">17</xref>
,
<xref rid="b18-jod-11-506" ref-type="bibr">18</xref>
] and yellow [
<xref rid="b18-jod-11-506" ref-type="bibr">18</xref>
] clips configuration and not by the other attachments including the ball/socket and magnet.</p>
<p>Although the exact same ball attachments were not used in the current investigation compared to the mentioned studies, the results of the current study regarding load measurements with vertically directed dislodging forces were similar to that of Michelinakis [
<xref rid="b17-jod-11-506" ref-type="bibr">17</xref>
] and Doukas [
<xref rid="b18-jod-11-506" ref-type="bibr">18</xref>
]. The retention was not affected by the inter-implant distance for MITSOs retained by two ball attachments. However, Michelinakis [
<xref rid="b17-jod-11-506" ref-type="bibr">17</xref>
] and Doukas [
<xref rid="b18-jod-11-506" ref-type="bibr">18</xref>
] had not measured the peak loads for obliquely and anterior-posteriorly directed dislodging forces. In order to better simulate the overdenture multidirectional movement, the peak loads should be measured with vertically, obliquely, and anterior-posteriorly directed dislodging forces.</p>
<p>The advantage of placing the implants in position C, which showed the highest resistance of overdenture to anterior-posteriorly directed dislodging forces, can be explained in physics and mechanics by the torque formula [
<xref rid="b23-jod-11-506" ref-type="bibr">23</xref>
]:
<list list-type="bullet">
<list-item>
<p>
<italic>τ</italic>
=
<italic>rF sin</italic>
ϕ</p>
</list-item>
<list-item>
<p>
<italic>τ</italic>
: Torque force</p>
</list-item>
<list-item>
<p>
<italic>r</italic>
: Distance from force to axis of rotation</p>
</list-item>
<list-item>
<p>
<italic>F</italic>
: Force</p>
</list-item>
<list-item>
<p>
<italic>ϕ</italic>
: Angle between
<italic>F</italic>
and
<italic>r</italic>
vectors</p>
</list-item>
</list>
</p>
<p>In different implant positions (A, B, and C), the amounts of ‘
<italic>F’</italic>
and ‘
<italic>ϕ</italic>
’ are constant while the amount of ‘
<italic>r’</italic>
is variable depending on implant positions. In position C, the axis of rotation, a virtual line that passes through the centers of the implants, moves backward and the amount of ‘
<italic>r’</italic>
for posterior forces is minimal. According to the above-mentioned formula, ‘
<italic>τ’</italic>
is minimal, thus the resistance against posterior forces is at its highest level as the results of the current investigation revealed. The significant difference between position C compared to A and B may be due to the arch curvature that causes greater anterior-posterior distance between B and C compared to A and B.</p>
<p>Based on the results of this study, placing implants with more inter-implant distance could be advantageous in increasing the resistance against anterior-posterior functional forces; however, it is unknown what effect this has on load distribution to the implants and mucosa. For MITSOs, the implants are proposed to be placed between the mental foramina. The mental foramen is usually located apical to the mandibular second premolar or between the apices of the premolars [
<xref rid="b16-jod-11-506" ref-type="bibr">16</xref>
]. Although Tokuhisa [
<xref rid="b20-jod-11-506" ref-type="bibr">20</xref>
] found that ball attachment could be advantageous in optimizing load transmission and minimizing overdenture movement compared to bar and magnet attachments, further studies are suggested considering both factors: inter-implant distance and load distribution to implants.</p>
<p>Van Kampen [
<xref rid="b14-jod-11-506" ref-type="bibr">14</xref>
], Petropoulos [
<xref rid="b5-jod-11-506" ref-type="bibr">5</xref>
,
<xref rid="b10-jod-11-506" ref-type="bibr">10</xref>
,
<xref rid="b15-jod-11-506" ref-type="bibr">15</xref>
], Tabatabaian [
<xref rid="b9-jod-11-506" ref-type="bibr">9</xref>
], Setz [
<xref rid="b24-jod-11-506" ref-type="bibr">24</xref>
], and Botega [
<xref rid="b25-jod-11-506" ref-type="bibr">25</xref>
] evaluated the retention and resistance of MITSOs using two implants. However, the exact distance between the implants was not revealed. In the majority of the aforementioned studies, several attachment types were subjected to testing in order to measure the retention with-out concerning the inter-implant distance.</p>
<p>This investigation was performed on a test cast with a medium-sized, ovoid arch form using pink nylon inserts (soft retention of 800–950 g listed by manufacturer) and ball abutments with a specific size. These factors may have affected the results. Therefore, evaluation of their potential impact can be the subject of future studies.</p>
</sec>
<sec>
<title>CONCLUSION</title>
<p>Within the limitations of this study, it was concluded that the inter-implant distance did not affect vertical retention and oblique resistance of MITSOs; however, it affected anterior-posterior resistance to dislodgement. Therefore, regarding functional dislodging forces, the most possible inter-implant distance provides the best level of resistance. Based on the present study, to achieve the optimal outcome for MITSOs with regard to retention and resistance, clinicians should consider the inter-implant distance in placing implants.</p>
</sec>
</body>
<back>
<ack>
<p>The authors thank the Research Deputy of the Dental School of Shahid Beheshti University of Medical Sciences for the support by Grant 310/487.</p>
</ack>
<ref-list>
<title>REFERENCES</title>
<ref id="b1-jod-11-506">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Feine</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Carlsson</surname>
<given-names>GE</given-names>
</name>
<name>
<surname>Awad</surname>
<given-names>MA</given-names>
</name>
<name>
<surname>Chehade</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Duncan</surname>
<given-names>WJ</given-names>
</name>
<name>
<surname>Gizani</surname>
<given-names>S</given-names>
</name>
<etal></etal>
</person-group>
<article-title>The McGill consensus statement on overdentures</article-title>
<source>Int J Prosthodont</source>
<year>2002</year>
<season>Jul-Aug</season>
<volume>15</volume>
<issue>4</issue>
<fpage>413</fpage>
<lpage>4</lpage>
<pub-id pub-id-type="pmid">12170858</pub-id>
</element-citation>
</ref>
<ref id="b2-jod-11-506">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mentag</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Kosinski</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>A clinical case illustrating a new implant abutment</article-title>
<source>Dent Today</source>
<year>1991</year>
<month>4</month>
<volume>10</volume>
<issue>3</issue>
<fpage>48</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">1867809</pub-id>
</element-citation>
</ref>
<ref id="b3-jod-11-506">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Trushkowsky</surname>
<given-names>RD</given-names>
</name>
</person-group>
<article-title>Fabrication of an immediate aesthetic overdenture utilizing a resilient attachment</article-title>
<source>Pract Periodontics Aesthet Dent</source>
<year>1992</year>
<month>8</month>
<volume>4</volume>
<issue>6</issue>
<fpage>41</fpage>
<lpage>5</lpage>
<pub-id pub-id-type="pmid">1391932</pub-id>
</element-citation>
</ref>
<ref id="b4-jod-11-506">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zitsmann</surname>
<given-names>NU</given-names>
</name>
<name>
<surname>Marinello</surname>
<given-names>CP</given-names>
</name>
</person-group>
<article-title>A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible</article-title>
<source>Int J Prosthodont</source>
<year>2002</year>
<season>Jan-Feb</season>
<volume>15</volume>
<issue>1</issue>
<fpage>65</fpage>
<lpage>72</lpage>
<pub-id pub-id-type="pmid">11887602</pub-id>
</element-citation>
</ref>
<ref id="b5-jod-11-506">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Petropoulos</surname>
<given-names>VC</given-names>
</name>
<name>
<surname>Mante</surname>
<given-names>FK</given-names>
</name>
</person-group>
<article-title>Comparison of retention and strain energies of stud attachments for implant overdentures</article-title>
<source>J Prosthodont</source>
<year>2011</year>
<month>6</month>
<volume>20</volume>
<issue>4</issue>
<fpage>286</fpage>
<lpage>293</lpage>
<pub-id pub-id-type="pmid">21539646</pub-id>
</element-citation>
</ref>
<ref id="b6-jod-11-506">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Naert</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Quirynen</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Theuniers</surname>
<given-names>G</given-names>
</name>
<name>
<surname>van Steenberghe</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>Prosthetic aspects of osseointegrated fixtures supporting overdentures: a 4–year report</article-title>
<source>J Prosthet Dent</source>
<year>1991</year>
<month>5</month>
<volume>65</volume>
<issue>5</issue>
<fpage>671</fpage>
<lpage>80</lpage>
<pub-id pub-id-type="pmid">2051392</pub-id>
</element-citation>
</ref>
<ref id="b7-jod-11-506">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burns</surname>
<given-names>DR</given-names>
</name>
<name>
<surname>Unger</surname>
<given-names>JW</given-names>
</name>
<name>
<surname>Elswick</surname>
<given-names>RK</given-names>
<suffix>Jr</suffix>
</name>
<name>
<surname>Beck</surname>
<given-names>DA</given-names>
</name>
</person-group>
<article-title>Prospective clinical evaluation of mandibular implant overdentures : Part I- Retention,stability and tissue response</article-title>
<source>J Prosthet Dent</source>
<year>1995</year>
<month>4</month>
<volume>73</volume>
<issue>4</issue>
<fpage>354</fpage>
<lpage>63</lpage>
<pub-id pub-id-type="pmid">7783014</pub-id>
</element-citation>
</ref>
<ref id="b8-jod-11-506">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burns</surname>
<given-names>DR</given-names>
</name>
<name>
<surname>Unger</surname>
<given-names>JW</given-names>
</name>
<name>
<surname>Elswick</surname>
<given-names>RK</given-names>
<suffix>Jr</suffix>
</name>
<name>
<surname>Giglio</surname>
<given-names>JA</given-names>
</name>
</person-group>
<article-title>Prospective clinical evaluation of mandibular implant overdentures : Part II- Patient satisfaction and preference</article-title>
<source>J Prosthet Dent</source>
<year>1995</year>
<month>4</month>
<volume>73</volume>
<issue>4</issue>
<fpage>364</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">7783015</pub-id>
</element-citation>
</ref>
<ref id="b9-jod-11-506">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tabatabaian</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Alaie</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Seyedan</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Comparison of three attachments in implant-tissue supported overdentures: An in vitro study</article-title>
<source>J Dent (Tehran)</source>
<year>2010</year>
<season>Summer</season>
<volume>7</volume>
<issue>3</issue>
<fpage>113</fpage>
<lpage>8</lpage>
<pub-id pub-id-type="pmid">21998784</pub-id>
</element-citation>
</ref>
<ref id="b10-jod-11-506">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Petropoulos</surname>
<given-names>VC</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>W</given-names>
</name>
</person-group>
<article-title>Maximum dislodging forces of implant overdenture stud attachments</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>2002</year>
<season>Jul-Aug</season>
<volume>17</volume>
<issue>4</issue>
<fpage>526</fpage>
<lpage>35</lpage>
<pub-id pub-id-type="pmid">12182295</pub-id>
</element-citation>
</ref>
<ref id="b11-jod-11-506">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rutkunas</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Mizutani</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Takahashi</surname>
<given-names>H</given-names>
</name>
</person-group>
<article-title>Influence of attachment wear on retention of mandibular overdenture</article-title>
<source>J Oral Rehabil</source>
<year>2007</year>
<month>1</month>
<volume>41</volume>
<issue>1</issue>
<fpage>34</fpage>
<lpage>51</lpage>
</element-citation>
</ref>
<ref id="b12-jod-11-506">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gamborena</surname>
<given-names>JI</given-names>
</name>
<name>
<surname>Hazelton</surname>
<given-names>LR</given-names>
</name>
<name>
<surname>NaBadalung</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Brudvik</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>Retention of ERA direct overdenture attachments before and after fatigue loading</article-title>
<source>Int J Prosthodont</source>
<year>1997</year>
<season>Mar-Apr</season>
<volume>10</volume>
<issue>2</issue>
<fpage>123</fpage>
<lpage>30</lpage>
<pub-id pub-id-type="pmid">9206451</pub-id>
</element-citation>
</ref>
<ref id="b13-jod-11-506">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gulizio</surname>
<given-names>MP</given-names>
</name>
<name>
<surname>Agar</surname>
<given-names>JR</given-names>
</name>
<name>
<surname>Kelly</surname>
<given-names>JR</given-names>
</name>
<name>
<surname>Taylor</surname>
<given-names>TD</given-names>
</name>
</person-group>
<article-title>Effect of implant angulation upon retention of overdenture attachments</article-title>
<source>J Prosthodont</source>
<year>2005</year>
<month>3</month>
<volume>14</volume>
<issue>1</issue>
<fpage>3</fpage>
<lpage>11</lpage>
<pub-id pub-id-type="pmid">15733129</pub-id>
</element-citation>
</ref>
<ref id="b14-jod-11-506">
<label>14</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Van Kampen</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Cune</surname>
<given-names>M</given-names>
</name>
<name>
<surname>van der Bilt</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Bosman</surname>
<given-names>F</given-names>
</name>
</person-group>
<article-title>Retention and post-insertion maintenance of bar-clip, ball and magnet attachments in mandibular overdenture treatment: an in vivo comparison after 3 months of function</article-title>
<source>Clin Oral Impants Res</source>
<year>2003</year>
<month>12</month>
<volume>14</volume>
<issue>6</issue>
<fpage>720</fpage>
<lpage>6</lpage>
</element-citation>
</ref>
<ref id="b15-jod-11-506">
<label>15</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Petropoulos</surname>
<given-names>VC</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Kousvelari</surname>
<given-names>E</given-names>
</name>
</person-group>
<article-title>Comparison of retention and release periods for implant overdenture attachments</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>1997</year>
<season>Mar-Apr</season>
<volume>12</volume>
<issue>2</issue>
<fpage>176</fpage>
<lpage>85</lpage>
<pub-id pub-id-type="pmid">9109267</pub-id>
</element-citation>
</ref>
<ref id="b16-jod-11-506">
<label>16</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Greenstein</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Tarnow</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review</article-title>
<source>J Periodontol</source>
<year>2006</year>
<month>12</month>
<volume>77</volume>
<issue>12</issue>
<fpage>1933</fpage>
<lpage>43</lpage>
<pub-id pub-id-type="pmid">17209776</pub-id>
</element-citation>
</ref>
<ref id="b17-jod-11-506">
<label>17</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Michelinakis</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Barclay</surname>
<given-names>CW</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>PW</given-names>
</name>
</person-group>
<article-title>The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values</article-title>
<source>Int J Prosthodont</source>
<year>2006</year>
<season>Sep-Oct</season>
<volume>19</volume>
<issue>5</issue>
<fpage>507</fpage>
<lpage>12</lpage>
<pub-id pub-id-type="pmid">17323731</pub-id>
</element-citation>
</ref>
<ref id="b18-jod-11-506">
<label>18</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Doukas</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Michelinakis</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>PW</given-names>
</name>
<name>
<surname>Barclay</surname>
<given-names>CW</given-names>
</name>
</person-group>
<article-title>The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: 6-month fatigue retention values</article-title>
<source>Int J Prosthodont</source>
<year>2008</year>
<season>Mar-Apr</season>
<volume>21</volume>
<issue>2</issue>
<fpage>152</fpage>
<lpage>4</lpage>
<pub-id pub-id-type="pmid">18546771</pub-id>
</element-citation>
</ref>
<ref id="b19-jod-11-506">
<label>19</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Alsabeeha</surname>
<given-names>NH</given-names>
</name>
<name>
<surname>Payne</surname>
<given-names>AG</given-names>
</name>
<name>
<surname>Swain</surname>
<given-names>MV</given-names>
</name>
</person-group>
<article-title>Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features</article-title>
<source>Int J Prosthodont</source>
<year>2009</year>
<season>Sep-Oct</season>
<volume>22</volume>
<issue>5</issue>
<fpage>429</fpage>
<lpage>40</lpage>
<pub-id pub-id-type="pmid">20095190</pub-id>
</element-citation>
</ref>
<ref id="b20-jod-11-506">
<label>20</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tokuhisa</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Matsushita</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Koyano</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability</article-title>
<source>Int J Prosthodont</source>
<year>2003</year>
<season>Mar-Apr</season>
<volume>16</volume>
<issue>2</issue>
<fpage>128</fpage>
<lpage>34</lpage>
<pub-id pub-id-type="pmid">12737242</pub-id>
</element-citation>
</ref>
<ref id="b21-jod-11-506">
<label>21</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sarnat</surname>
<given-names>AE</given-names>
</name>
</person-group>
<article-title>The efficiency of cobalt samarium magnets as retentive units for overdentures</article-title>
<source>J Dent</source>
<year>1983</year>
<month>12</month>
<volume>11</volume>
<issue>4</issue>
<fpage>324</fpage>
<lpage>33</lpage>
<pub-id pub-id-type="pmid">6365997</pub-id>
</element-citation>
</ref>
<ref id="b22-jod-11-506">
<label>22</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Daniel</surname>
<given-names>WW</given-names>
</name>
</person-group>
<article-title>Nonparametric and distribution-free statistic</article-title>
<person-group person-group-type="editor">
<name>
<surname>Daniel</surname>
<given-names>WW</given-names>
</name>
</person-group>
<source>Biostatistics: a foundation for analysis in the health sciences</source>
<edition>6th ed</edition>
<publisher-loc>New York</publisher-loc>
<publisher-name>John Wiley & Sons Inc</publisher-name>
<year>1995</year>
<fpage>567</fpage>
<lpage>631</lpage>
</element-citation>
</ref>
<ref id="b23-jod-11-506">
<label>23</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Halliday</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Resnick</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Walker</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>Rotation of a rigid object about a fixed axis</article-title>
<person-group person-group-type="editor">
<name>
<surname>Halliday</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Resnick</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Walker</surname>
<given-names>J</given-names>
</name>
</person-group>
<source>Fundamentals of physics</source>
<edition>8th ed</edition>
<publisher-loc>New York</publisher-loc>
<publisher-name>John Wiley & Sons Inc</publisher-name>
<year>2008</year>
<fpage>292</fpage>
<lpage>326</lpage>
</element-citation>
</ref>
<ref id="b24-jod-11-506">
<label>24</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Setz</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>SH</given-names>
</name>
<name>
<surname>Engle</surname>
<given-names>E</given-names>
</name>
</person-group>
<article-title>Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: An in vitro study</article-title>
<source>J Prosthet Dent</source>
<year>1998</year>
<month>9</month>
<volume>80</volume>
<issue>3</issue>
<fpage>323</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">9760365</pub-id>
</element-citation>
</ref>
<ref id="b25-jod-11-506">
<label>25</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Botega</surname>
<given-names>DM</given-names>
</name>
<name>
<surname>Mesquita</surname>
<given-names>MF</given-names>
</name>
<name>
<surname>Henriques</surname>
<given-names>GE</given-names>
</name>
<name>
<surname>Vaz</surname>
<given-names>LG</given-names>
</name>
</person-group>
<article-title>Retention force and fatigue strength of overdenture attachment systems</article-title>
<source>J Oral Rehabil</source>
<year>2004</year>
<month>9</month>
<volume>31</volume>
<issue>9</issue>
<fpage>884</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">15369470</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
<floats-group>
<fig id="f1-jod-11-506" position="float">
<label>Fig 1.</label>
<caption>
<p>Design of the different parts. Locations of implants, overdenture, and force application points based on the hypothetical triangular design</p>
</caption>
<graphic xlink:href="jod-11-506f1"></graphic>
</fig>
<fig id="f2-jod-11-506" position="float">
<label>Fig 2.</label>
<caption>
<p>The framework with a special design seated on the test cast while encircling the six implants</p>
</caption>
<graphic xlink:href="jod-11-506f2"></graphic>
</fig>
<fig id="f3-jod-11-506" position="float">
<label>Fig 3.</label>
<caption>
<p>Ball attachment set including three components: ball abutment (below), attachment housing (above, external part), and pink nylon insert (above, internal part)</p>
</caption>
<graphic xlink:href="jod-11-506f3"></graphic>
</fig>
<fig id="f4-jod-11-506" position="float">
<label>Fig 4.</label>
<caption>
<p>Overdenture. Attachment housings with pink nylon inserts placed within the overdenture housing</p>
</caption>
<graphic xlink:href="jod-11-506f4"></graphic>
</fig>
<fig id="f5-jod-11-506" position="float">
<label>Fig 5.</label>
<caption>
<p>Zwick testing machine. Connections of the machine, load cell, overdenture, and test cast for load transmission</p>
</caption>
<graphic xlink:href="jod-11-506f5"></graphic>
</fig>
<fig id="f6-jod-11-506" position="float">
<label>Fig 6.</label>
<caption>
<p>Mean values and standard deviations of the peak loads (N) for vertically directed dislodging forces for three inter-implant distances: A (10mm), B (25mm), and C (35mm)</p>
</caption>
<graphic xlink:href="jod-11-506f6"></graphic>
</fig>
<fig id="f7-jod-11-506" position="float">
<label>Fig 7.</label>
<caption>
<p>Mean values and standard deviations of the peak loads (N) for obliquely directed dislodging forces for three inter-implant distances: A (10mm), B (25mm), and C (35mm)</p>
</caption>
<graphic xlink:href="jod-11-506f7"></graphic>
</fig>
<fig id="f8-jod-11-506" position="float">
<label>Fig 8.</label>
<caption>
<p>Mean values and standard deviations of the peak loads (N) for anterior-posteriorly directed dislodging forces for three inter-implant distances: A (10mm), B (25mm), and C (35mm)</p>
</caption>
<graphic xlink:href="jod-11-506f8"></graphic>
</fig>
</floats-group>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003083 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 003083 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4290769
   |texte=   The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:25628676" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022