Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics

Identifieur interne : 002D62 ( Pmc/Corpus ); précédent : 002D61; suivant : 002D63

Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics

Auteurs : Jaafar Abduo ; Karl Lyons

Source :

RBID : PMC:3652193

Abstract

Despite the predictable longevity of implant prosthesis, there is an ongoing interest to continue to improve implant prosthodontic treatment and outcomes. One of the developments is the application of computer-aided design and computer-aided manufacturing (CAD/CAM) to produce implant abutments and frameworks from metal or ceramic materials. The aim of this narrative review is to critically evaluate the rationale of CAD/CAM utilization for implant prosthodontics. To date, CAD/CAM allows simplified production of precise and durable implant components. The precision of fit has been proven in several laboratory experiments and has been attributed to the design of implants. Milling also facilitates component fabrication from durable and aesthetic materials. With further development, it is expected that the CAD/CAM protocol will be further simplified. Although compelling clinical evidence supporting the superiority of CAD/CAM implant restorations is still lacking, it is envisioned that CAD/CAM may become the main stream for implant component fabrication.


Url:
DOI: 10.1155/2013/768121
PubMed: 23690778
PubMed Central: 3652193

Links to Exploration step

PMC:3652193

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics</title>
<author>
<name sortKey="Abduo, Jaafar" sort="Abduo, Jaafar" uniqKey="Abduo J" first="Jaafar" last="Abduo">Jaafar Abduo</name>
<affiliation>
<nlm:aff id="I1">School of Dentistry, Melbourne University, 720 Swanston Street, Carlton Melbourne, VIC 3010, Australia</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Lyons, Karl" sort="Lyons, Karl" uniqKey="Lyons K" first="Karl" last="Lyons">Karl Lyons</name>
<affiliation>
<nlm:aff id="I2">Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin 9054, New Zealand</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">23690778</idno>
<idno type="pmc">3652193</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3652193</idno>
<idno type="RBID">PMC:3652193</idno>
<idno type="doi">10.1155/2013/768121</idno>
<date when="2013">2013</date>
<idno type="wicri:Area/Pmc/Corpus">002D62</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002D62</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics</title>
<author>
<name sortKey="Abduo, Jaafar" sort="Abduo, Jaafar" uniqKey="Abduo J" first="Jaafar" last="Abduo">Jaafar Abduo</name>
<affiliation>
<nlm:aff id="I1">School of Dentistry, Melbourne University, 720 Swanston Street, Carlton Melbourne, VIC 3010, Australia</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Lyons, Karl" sort="Lyons, Karl" uniqKey="Lyons K" first="Karl" last="Lyons">Karl Lyons</name>
<affiliation>
<nlm:aff id="I2">Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin 9054, New Zealand</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International Journal of Dentistry</title>
<idno type="ISSN">1687-8728</idno>
<idno type="eISSN">1687-8736</idno>
<imprint>
<date when="2013">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>Despite the predictable longevity of implant prosthesis, there is an ongoing interest to continue to improve implant prosthodontic treatment and outcomes. One of the developments is the application of computer-aided design and computer-aided manufacturing (CAD/CAM) to produce implant abutments and frameworks from metal or ceramic materials. The aim of this narrative review is to critically evaluate the rationale of CAD/CAM utilization for implant prosthodontics. To date, CAD/CAM allows simplified production of precise and durable implant components. The precision of fit has been proven in several laboratory experiments and has been attributed to the design of implants. Milling also facilitates component fabrication from durable and aesthetic materials. With further development, it is expected that the CAD/CAM protocol will be further simplified. Although compelling clinical evidence supporting the superiority of CAD/CAM implant restorations is still lacking, it is envisioned that CAD/CAM may become the main stream for implant component fabrication.</p>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Kapos, T" uniqKey="Kapos T">T Kapos</name>
</author>
<author>
<name sortKey="Ashy, Lm" uniqKey="Ashy L">LM Ashy</name>
</author>
<author>
<name sortKey="Gallucci, Go" uniqKey="Gallucci G">GO Gallucci</name>
</author>
<author>
<name sortKey="Weber, Hp" uniqKey="Weber H">HP Weber</name>
</author>
<author>
<name sortKey="Wismeijer, D" uniqKey="Wismeijer D">D Wismeijer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Priest, G" uniqKey="Priest G">G Priest</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Van Noort, R" uniqKey="Van Noort R">R van Noort</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Miyazaki, T" uniqKey="Miyazaki T">T Miyazaki</name>
</author>
<author>
<name sortKey="Hotta, Y" uniqKey="Hotta Y">Y Hotta</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sailer, I" uniqKey="Sailer I">I Sailer</name>
</author>
<author>
<name sortKey="Sailer, T" uniqKey="Sailer T">T Sailer</name>
</author>
<author>
<name sortKey="Stawarczyk, B" uniqKey="Stawarczyk B">B Stawarczyk</name>
</author>
<author>
<name sortKey="Jung, Re" uniqKey="Jung R">RE Jung</name>
</author>
<author>
<name sortKey="H Mmerle, Ch" uniqKey="H Mmerle C">CH Hämmerle</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Aboushelib, Mn" uniqKey="Aboushelib M">MN Aboushelib</name>
</author>
<author>
<name sortKey="Salameh, Z" uniqKey="Salameh Z">Z Salameh</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Goodacre, Cj" uniqKey="Goodacre C">CJ Goodacre</name>
</author>
<author>
<name sortKey="Campagni, Wv" uniqKey="Campagni W">WV Campagni</name>
</author>
<author>
<name sortKey="Aquilino, Sa" uniqKey="Aquilino S">SA Aquilino</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Guess, Pc" uniqKey="Guess P">PC Guess</name>
</author>
<author>
<name sortKey="Att, W" uniqKey="Att W">W Att</name>
</author>
<author>
<name sortKey="Strub, Jr" uniqKey="Strub J">JR Strub</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Silva, Nrfa" uniqKey="Silva N">NRFA Silva</name>
</author>
<author>
<name sortKey="Bonfante, Ea" uniqKey="Bonfante E">EA Bonfante</name>
</author>
<author>
<name sortKey="Rafferty, Bt" uniqKey="Rafferty B">BT Rafferty</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kokubo, Y" uniqKey="Kokubo Y">Y Kokubo</name>
</author>
<author>
<name sortKey="Tsumita, M" uniqKey="Tsumita M">M Tsumita</name>
</author>
<author>
<name sortKey="Kano, T" uniqKey="Kano T">T Kano</name>
</author>
<author>
<name sortKey="Fukushima, S" uniqKey="Fukushima S">S Fukushima</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Guess, Pc" uniqKey="Guess P">PC Guess</name>
</author>
<author>
<name sortKey="Bonfante, Ea" uniqKey="Bonfante E">EA Bonfante</name>
</author>
<author>
<name sortKey="Silva, Nr" uniqKey="Silva N">NR Silva</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Furze, D" uniqKey="Furze D">D Furze</name>
</author>
<author>
<name sortKey="Byrne, A" uniqKey="Byrne A">A Byrne</name>
</author>
<author>
<name sortKey="Donos, N" uniqKey="Donos N">N Donos</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Chee, W" uniqKey="Chee W">W Chee</name>
</author>
<author>
<name sortKey="Jivraj, S" uniqKey="Jivraj S">S Jivraj</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sailer, I" uniqKey="Sailer I">I Sailer</name>
</author>
<author>
<name sortKey="Zembic, A" uniqKey="Zembic A">A Zembic</name>
</author>
<author>
<name sortKey="Jung, Re" uniqKey="Jung R">RE Jung</name>
</author>
<author>
<name sortKey="H Mmerle, Ch" uniqKey="H Mmerle C">CH Hämmerle</name>
</author>
<author>
<name sortKey="Mattiola, A" uniqKey="Mattiola A">A Mattiola</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bernal, G" uniqKey="Bernal G">G Bernal</name>
</author>
<author>
<name sortKey="Okamura, M" uniqKey="Okamura M">M Okamura</name>
</author>
<author>
<name sortKey="Mu Oz, Ca" uniqKey="Mu Oz C">CA Muñoz</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Cano Batalla, J" uniqKey="Cano Batalla J">J Cano-Batalla</name>
</author>
<author>
<name sortKey="Soliva Garriga, J" uniqKey="Soliva Garriga J">J Soliva-Garriga</name>
</author>
<author>
<name sortKey="Campillo Funollet, M" uniqKey="Campillo Funollet M">M Campillo-Funollet</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Abduo, J" uniqKey="Abduo J">J Abduo</name>
</author>
<author>
<name sortKey="Bennani, V" uniqKey="Bennani V">V Bennani</name>
</author>
<author>
<name sortKey="Waddell, N" uniqKey="Waddell N">N Waddell</name>
</author>
<author>
<name sortKey="Lyons, K" uniqKey="Lyons K">K Lyons</name>
</author>
<author>
<name sortKey="Swain, M" uniqKey="Swain M">M Swain</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Heydecke, G" uniqKey="Heydecke G">G Heydecke</name>
</author>
<author>
<name sortKey="Sierraalta, M" uniqKey="Sierraalta M">M Sierraalta</name>
</author>
<author>
<name sortKey="Razzoog, Me" uniqKey="Razzoog M">ME Razzoog</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kohal, Rj" uniqKey="Kohal R">RJ Kohal</name>
</author>
<author>
<name sortKey="Att, W" uniqKey="Att W">W Att</name>
</author>
<author>
<name sortKey="B Chle, M" uniqKey="B Chle M">M Bächle</name>
</author>
<author>
<name sortKey="Butz, F" uniqKey="Butz F">F Butz</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Byrne, D" uniqKey="Byrne D">D Byrne</name>
</author>
<author>
<name sortKey="Houston, F" uniqKey="Houston F">F Houston</name>
</author>
<author>
<name sortKey="Cleary, R" uniqKey="Cleary R">R Cleary</name>
</author>
<author>
<name sortKey="Claffey, N" uniqKey="Claffey N">N Claffey</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kano, Sc" uniqKey="Kano S">SC Kano</name>
</author>
<author>
<name sortKey="Binon, Pp" uniqKey="Binon P">PP Binon</name>
</author>
<author>
<name sortKey="Curtis, Da" uniqKey="Curtis D">DA Curtis</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Att, W" uniqKey="Att W">W Att</name>
</author>
<author>
<name sortKey="Yajima, Nd" uniqKey="Yajima N">ND Yajima</name>
</author>
<author>
<name sortKey="Wolkewitz, M" uniqKey="Wolkewitz M">M Wolkewitz</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Taylor, Td" uniqKey="Taylor T">TD Taylor</name>
</author>
<author>
<name sortKey="Agar, Jr" uniqKey="Agar J">JR Agar</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lewis, Sg" uniqKey="Lewis S">SG Lewis</name>
</author>
<author>
<name sortKey="Beumer Rd J, J" uniqKey="Beumer Rd J J">J Beumer 3rd. J.</name>
</author>
<author>
<name sortKey="Perri, Gr" uniqKey="Perri G">GR Perri</name>
</author>
<author>
<name sortKey="Hornburg, Wp" uniqKey="Hornburg W">WP Hornburg</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ortorp, A" uniqKey="Ortorp A">A Örtorp</name>
</author>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
<author>
<name sortKey="B Ck, T" uniqKey="B Ck T">T Bäck</name>
</author>
<author>
<name sortKey="J Levik, T" uniqKey="J Levik T">T Jälevik</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Takahashi, T" uniqKey="Takahashi T">T Takahashi</name>
</author>
<author>
<name sortKey="Gunne, J" uniqKey="Gunne J">J Gunne</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
<author>
<name sortKey="B Ck, T" uniqKey="B Ck T">T Bäck</name>
</author>
<author>
<name sortKey="Petersson, A" uniqKey="Petersson A">A Petersson</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Abduo, J" uniqKey="Abduo J">J Abduo</name>
</author>
<author>
<name sortKey="Lyons, K" uniqKey="Lyons K">K Lyons</name>
</author>
<author>
<name sortKey="Bennani, V" uniqKey="Bennani V">V Bennani</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Parpaiola, A" uniqKey="Parpaiola A">A Parpaiola</name>
</author>
<author>
<name sortKey="Norton, Mr" uniqKey="Norton M">MR Norton</name>
</author>
<author>
<name sortKey="Cecchinato, D" uniqKey="Cecchinato D">D Cecchinato</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Beuer, F" uniqKey="Beuer F">F Beuer</name>
</author>
<author>
<name sortKey="Schweiger, J" uniqKey="Schweiger J">J Schweiger</name>
</author>
<author>
<name sortKey="Edelhoff, D" uniqKey="Edelhoff D">D Edelhoff</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Abduo, J" uniqKey="Abduo J">J Abduo</name>
</author>
<author>
<name sortKey="Lyons, K" uniqKey="Lyons K">K Lyons</name>
</author>
<author>
<name sortKey="Swain, M" uniqKey="Swain M">M Swain</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tan, Pl" uniqKey="Tan P">PL Tan</name>
</author>
<author>
<name sortKey="Gratton, Dg" uniqKey="Gratton D">DG Gratton</name>
</author>
<author>
<name sortKey="Diaz Arnold, Am" uniqKey="Diaz Arnold A">AM Diaz-Arnold</name>
</author>
<author>
<name sortKey="Holmes, Dc" uniqKey="Holmes D">DC Holmes</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Thompson, Wb" uniqKey="Thompson W">WB Thompson</name>
</author>
<author>
<name sortKey="Owen, Jc" uniqKey="Owen J">JC Owen</name>
</author>
<author>
<name sortKey="De, Sg" uniqKey="De S">SG De</name>
</author>
<author>
<name sortKey="Stark, Sr" uniqKey="Stark S">SR Stark</name>
</author>
<author>
<name sortKey="Henderson, Tc" uniqKey="Henderson T">TC Henderson</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Persson, A" uniqKey="Persson A">A Persson</name>
</author>
<author>
<name sortKey="Andersson, M" uniqKey="Andersson M">M Andersson</name>
</author>
<author>
<name sortKey="Oden, A" uniqKey="Oden A">A Oden</name>
</author>
<author>
<name sortKey="Sandborgh Englund, G" uniqKey="Sandborgh Englund G">G Sandborgh-Englund</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ender, A" uniqKey="Ender A">A Ender</name>
</author>
<author>
<name sortKey="Mormann, Wh" uniqKey="Mormann W">WH Mörmann</name>
</author>
<author>
<name sortKey="Mehl, A" uniqKey="Mehl A">A Mehl</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mehl, A" uniqKey="Mehl A">A Mehl</name>
</author>
<author>
<name sortKey="Blanz, V" uniqKey="Blanz V">V Blanz</name>
</author>
<author>
<name sortKey="Hickel, R" uniqKey="Hickel R">R Hickel</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ortorp, A" uniqKey="Ortorp A">A Örtorp</name>
</author>
<author>
<name sortKey="Jonsson, D" uniqKey="Jonsson D">D Jönsson</name>
</author>
<author>
<name sortKey="Mouhsen, A" uniqKey="Mouhsen A">A Mouhsen</name>
</author>
<author>
<name sortKey="Vult Von Steyern, P" uniqKey="Vult Von Steyern P">P Vult Von Steyern</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Yuzugullu, B" uniqKey="Yuzugullu B">B Yüzügüllü</name>
</author>
<author>
<name sortKey="Avci, M" uniqKey="Avci M">M Avci</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Vigolo, P" uniqKey="Vigolo P">P Vigolo</name>
</author>
<author>
<name sortKey="Fonzi, F" uniqKey="Fonzi F">F Fonzi</name>
</author>
<author>
<name sortKey="Majzoub, Z" uniqKey="Majzoub Z">Z Majzoub</name>
</author>
<author>
<name sortKey="Cordioli, G" uniqKey="Cordioli G">G Cordioli</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Abduo, J" uniqKey="Abduo J">J Abduo</name>
</author>
<author>
<name sortKey="Lyons, K" uniqKey="Lyons K">K Lyons</name>
</author>
<author>
<name sortKey="Waddell, N" uniqKey="Waddell N">N Waddell</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Glauser, R" uniqKey="Glauser R">R Glauser</name>
</author>
<author>
<name sortKey="Sailer, I" uniqKey="Sailer I">I Sailer</name>
</author>
<author>
<name sortKey="Wohlwend, A" uniqKey="Wohlwend A">A Wohlwend</name>
</author>
<author>
<name sortKey="Studer, S" uniqKey="Studer S">S Studer</name>
</author>
<author>
<name sortKey="Schibli, M" uniqKey="Schibli M">M Schibli</name>
</author>
<author>
<name sortKey="Sch Rer, P" uniqKey="Sch Rer P">P Schärer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ortorp, A" uniqKey="Ortorp A">A Ortorp</name>
</author>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Denry, I" uniqKey="Denry I">I Denry</name>
</author>
<author>
<name sortKey="Kelly, Jr" uniqKey="Kelly J">JR Kelly</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Yildirim, M" uniqKey="Yildirim M">M Yildirim</name>
</author>
<author>
<name sortKey="Fischer, H" uniqKey="Fischer H">H Fischer</name>
</author>
<author>
<name sortKey="Marx, R" uniqKey="Marx R">R Marx</name>
</author>
<author>
<name sortKey="Edelhoff, D" uniqKey="Edelhoff D">D Edelhoff</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kerstein, Rb" uniqKey="Kerstein R">RB Kerstein</name>
</author>
<author>
<name sortKey="Radke, J" uniqKey="Radke J">J Radke</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hosseini, M" uniqKey="Hosseini M">M Hosseini</name>
</author>
<author>
<name sortKey="Kleven, E" uniqKey="Kleven E">E Kleven</name>
</author>
<author>
<name sortKey="Gotfredsen, K" uniqKey="Gotfredsen K">K Gotfredsen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Aramouni, P" uniqKey="Aramouni P">P Aramouni</name>
</author>
<author>
<name sortKey="Zebouni, E" uniqKey="Zebouni E">E Zebouni</name>
</author>
<author>
<name sortKey="Tashkandi, E" uniqKey="Tashkandi E">E Tashkandi</name>
</author>
<author>
<name sortKey="Dib, S" uniqKey="Dib S">S Dib</name>
</author>
<author>
<name sortKey="Salameh, Z" uniqKey="Salameh Z">Z Salameh</name>
</author>
<author>
<name sortKey="Almas, K" uniqKey="Almas K">K Almas</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Butz, F" uniqKey="Butz F">F Butz</name>
</author>
<author>
<name sortKey="Heydecke, G" uniqKey="Heydecke G">G Heydecke</name>
</author>
<author>
<name sortKey="Okutan, M" uniqKey="Okutan M">M Okutan</name>
</author>
<author>
<name sortKey="Strub, Jr" uniqKey="Strub J">JR Strub</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Att, W" uniqKey="Att W">W Att</name>
</author>
<author>
<name sortKey="Kurun, S" uniqKey="Kurun S">S Kurun</name>
</author>
<author>
<name sortKey="Gerds, T" uniqKey="Gerds T">T Gerds</name>
</author>
<author>
<name sortKey="Strub, Jr" uniqKey="Strub J">JR Strub</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Att, W" uniqKey="Att W">W Att</name>
</author>
<author>
<name sortKey="Kurun, S" uniqKey="Kurun S">S Kurun</name>
</author>
<author>
<name sortKey="Gerds, T" uniqKey="Gerds T">T Gerds</name>
</author>
<author>
<name sortKey="Strub, Jr" uniqKey="Strub J">JR Strub</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sailer, I" uniqKey="Sailer I">I Sailer</name>
</author>
<author>
<name sortKey="Pjetursson, Be" uniqKey="Pjetursson B">BE Pjetursson</name>
</author>
<author>
<name sortKey="Zwahlen, M" uniqKey="Zwahlen M">M Zwahlen</name>
</author>
<author>
<name sortKey="H Mmerle, Chf" uniqKey="H Mmerle C">CHF Hämmerle</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Haraldson, T" uniqKey="Haraldson T">T Haraldson</name>
</author>
<author>
<name sortKey="Carlsson, Ge" uniqKey="Carlsson G">GE Carlsson</name>
</author>
<author>
<name sortKey="Ingervall, B" uniqKey="Ingervall B">B Ingervall</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kiliaridis, S" uniqKey="Kiliaridis S">S Kiliaridis</name>
</author>
<author>
<name sortKey="Kjellberg, H" uniqKey="Kjellberg H">H Kjellberg</name>
</author>
<author>
<name sortKey="Wenneberg, B" uniqKey="Wenneberg B">B Wenneberg</name>
</author>
<author>
<name sortKey="Engstrom, C" uniqKey="Engstrom C">C Engström</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kokubo, Y" uniqKey="Kokubo Y">Y Kokubo</name>
</author>
<author>
<name sortKey="Tsumita, M" uniqKey="Tsumita M">M Tsumita</name>
</author>
<author>
<name sortKey="Sakurai, S" uniqKey="Sakurai S">S Sakurai</name>
</author>
<author>
<name sortKey="Torizuka, K" uniqKey="Torizuka K">K Torizuka</name>
</author>
<author>
<name sortKey="Vult Von Steyern, P" uniqKey="Vult Von Steyern P">P Vult Von Steyern</name>
</author>
<author>
<name sortKey="Fukushima, S" uniqKey="Fukushima S">S Fukushima</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Schmitter, M" uniqKey="Schmitter M">M Schmitter</name>
</author>
<author>
<name sortKey="Mussotter, K" uniqKey="Mussotter K">K Mussotter</name>
</author>
<author>
<name sortKey="Rammelsberg, P" uniqKey="Rammelsberg P">P Rammelsberg</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sax, C" uniqKey="Sax C">C Sax</name>
</author>
<author>
<name sortKey="Hammerle, Ch" uniqKey="Hammerle C">CH Hammerle</name>
</author>
<author>
<name sortKey="Sailer, I" uniqKey="Sailer I">I Sailer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kohal, Rj" uniqKey="Kohal R">RJ Kohal</name>
</author>
<author>
<name sortKey="Wolkewitz, M" uniqKey="Wolkewitz M">M Wolkewitz</name>
</author>
<author>
<name sortKey="Mueller, C" uniqKey="Mueller C">C Mueller</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Nguyen, Hq" uniqKey="Nguyen H">HQ Nguyen</name>
</author>
<author>
<name sortKey="Tan, Kb" uniqKey="Tan K">KB Tan</name>
</author>
<author>
<name sortKey="Nicholls, Ji" uniqKey="Nicholls J">JI Nicholls</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ohlmann, B" uniqKey="Ohlmann B">B Ohlmann</name>
</author>
<author>
<name sortKey="Marienburg, K" uniqKey="Marienburg K">K Marienburg</name>
</author>
<author>
<name sortKey="Gabbert, O" uniqKey="Gabbert O">O Gabbert</name>
</author>
<author>
<name sortKey="Hassel, A" uniqKey="Hassel A">A Hassel</name>
</author>
<author>
<name sortKey="Gilde, H" uniqKey="Gilde H">H Gilde</name>
</author>
<author>
<name sortKey="Rammelsberg, P" uniqKey="Rammelsberg P">P Rammelsberg</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ekfeldt, A" uniqKey="Ekfeldt A">A Ekfeldt</name>
</author>
<author>
<name sortKey="Furst, B" uniqKey="Furst B">B Furst</name>
</author>
<author>
<name sortKey="Carlsson, Ge" uniqKey="Carlsson G">GE Carlsson</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sailer, I" uniqKey="Sailer I">I Sailer</name>
</author>
<author>
<name sortKey="Philipp, A" uniqKey="Philipp A">A Philipp</name>
</author>
<author>
<name sortKey="Zembic, A" uniqKey="Zembic A">A Zembic</name>
</author>
<author>
<name sortKey="Pjetursson, Be" uniqKey="Pjetursson B">BE Pjetursson</name>
</author>
<author>
<name sortKey="H Mmerle, Chf" uniqKey="H Mmerle C">CHF Hämmerle</name>
</author>
<author>
<name sortKey="Zwahlen, M" uniqKey="Zwahlen M">M Zwahlen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Larsson, C" uniqKey="Larsson C">C Larsson</name>
</author>
<author>
<name sortKey="Vult Von Steyern, P" uniqKey="Vult Von Steyern P">P Vult von Steyern</name>
</author>
<author>
<name sortKey="Nilner, K" uniqKey="Nilner K">K Nilner</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Larsson, C" uniqKey="Larsson C">C Larsson</name>
</author>
<author>
<name sortKey="Vult Von Steyern, P" uniqKey="Vult Von Steyern P">P Vult von Steyern</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kim, Jh" uniqKey="Kim J">JH Kim</name>
</author>
<author>
<name sortKey="Lee, Sj" uniqKey="Lee S">SJ Lee</name>
</author>
<author>
<name sortKey="Park, Js" uniqKey="Park J">JS Park</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Karl, M" uniqKey="Karl M">M Karl</name>
</author>
<author>
<name sortKey="Graef, F" uniqKey="Graef F">F Graef</name>
</author>
<author>
<name sortKey="Wichmann, M" uniqKey="Wichmann M">M Wichmann</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Swain, Mv" uniqKey="Swain M">MV Swain</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rojas Vizcaya, F" uniqKey="Rojas Vizcaya F">F Rojas-Vizcaya</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sorensen, Ja" uniqKey="Sorensen J">JA Sorensen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Coldea, A" uniqKey="Coldea A">A Coldea</name>
</author>
<author>
<name sortKey="Swain, Mv" uniqKey="Swain M">MV Swain</name>
</author>
<author>
<name sortKey="Thiel, N" uniqKey="Thiel N">N Thiel</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mormann, Wh" uniqKey="Mormann W">WH Mormann</name>
</author>
<author>
<name sortKey="Stawarczyk, B" uniqKey="Stawarczyk B">B Stawarczyk</name>
</author>
<author>
<name sortKey="Ender, A" uniqKey="Ender A">A Ender</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Telleman, G" uniqKey="Telleman G">G Telleman</name>
</author>
<author>
<name sortKey="Raghoebar, Gm" uniqKey="Raghoebar G">GM Raghoebar</name>
</author>
<author>
<name sortKey="Vissink, A" uniqKey="Vissink A">A Vissink</name>
</author>
<author>
<name sortKey="Meijer, Hja" uniqKey="Meijer H">HJA Meijer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Grossmann, Y" uniqKey="Grossmann Y">Y Grossmann</name>
</author>
<author>
<name sortKey="Pasciuta, M" uniqKey="Pasciuta M">M Pasciuta</name>
</author>
<author>
<name sortKey="Finger, Im" uniqKey="Finger I">IM Finger</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ramsey, Cd" uniqKey="Ramsey C">CD Ramsey</name>
</author>
<author>
<name sortKey="Ritter, Rg" uniqKey="Ritter R">RG Ritter</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Eliasson, A" uniqKey="Eliasson A">A Eliasson</name>
</author>
<author>
<name sortKey="Ortorp, A" uniqKey="Ortorp A">A Örtorp</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Michalakis, Kx" uniqKey="Michalakis K">KX Michalakis</name>
</author>
<author>
<name sortKey="Hirayama, H" uniqKey="Hirayama H">H Hirayama</name>
</author>
<author>
<name sortKey="Garefis, Pd" uniqKey="Garefis P">PD Garefis</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rauscher, O" uniqKey="Rauscher O">O Rauscher</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Brown, Sdk" uniqKey="Brown S">SDK Brown</name>
</author>
<author>
<name sortKey="Payne, Agt" uniqKey="Payne A">AGT Payne</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Int J Dent</journal-id>
<journal-id journal-id-type="iso-abbrev">Int J Dent</journal-id>
<journal-id journal-id-type="publisher-id">IJD</journal-id>
<journal-title-group>
<journal-title>International Journal of Dentistry</journal-title>
</journal-title-group>
<issn pub-type="ppub">1687-8728</issn>
<issn pub-type="epub">1687-8736</issn>
<publisher>
<publisher-name>Hindawi Publishing Corporation</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">23690778</article-id>
<article-id pub-id-type="pmc">3652193</article-id>
<article-id pub-id-type="doi">10.1155/2013/768121</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Review Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Abduo</surname>
<given-names>Jaafar</given-names>
</name>
<xref ref-type="aff" rid="I1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="cor1">*</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Lyons</surname>
<given-names>Karl</given-names>
</name>
<xref ref-type="aff" rid="I2">
<sup>2</sup>
</xref>
</contrib>
</contrib-group>
<aff id="I1">
<sup>1</sup>
School of Dentistry, Melbourne University, 720 Swanston Street, Carlton Melbourne, VIC 3010, Australia</aff>
<aff id="I2">
<sup>2</sup>
Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin 9054, New Zealand</aff>
<author-notes>
<corresp id="cor1">*Jaafar Abduo:
<email>jaafar_abduo@hotmail.com</email>
</corresp>
<fn fn-type="other">
<p>Academic Editor: Moustafa N. Aboushelib</p>
</fn>
</author-notes>
<pub-date pub-type="ppub">
<year>2013</year>
</pub-date>
<pub-date pub-type="epub">
<day>16</day>
<month>4</month>
<year>2013</year>
</pub-date>
<volume>2013</volume>
<elocation-id>768121</elocation-id>
<history>
<date date-type="received">
<day>25</day>
<month>9</month>
<year>2012</year>
</date>
<date date-type="accepted">
<day>28</day>
<month>3</month>
<year>2013</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright © 2013 J. Abduo and K. Lyons.</copyright-statement>
<copyright-year>2013</copyright-year>
<license xlink:href="https://creativecommons.org/licenses/by/3.0/">
<license-p>This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<p>Despite the predictable longevity of implant prosthesis, there is an ongoing interest to continue to improve implant prosthodontic treatment and outcomes. One of the developments is the application of computer-aided design and computer-aided manufacturing (CAD/CAM) to produce implant abutments and frameworks from metal or ceramic materials. The aim of this narrative review is to critically evaluate the rationale of CAD/CAM utilization for implant prosthodontics. To date, CAD/CAM allows simplified production of precise and durable implant components. The precision of fit has been proven in several laboratory experiments and has been attributed to the design of implants. Milling also facilitates component fabrication from durable and aesthetic materials. With further development, it is expected that the CAD/CAM protocol will be further simplified. Although compelling clinical evidence supporting the superiority of CAD/CAM implant restorations is still lacking, it is envisioned that CAD/CAM may become the main stream for implant component fabrication.</p>
</abstract>
</article-meta>
</front>
<body>
<sec id="sec1">
<title>1. Introduction</title>
<p>For over three decades, evidence to support the validity of oral implants as a treatment option to replace missing teeth has been accumulating. The impressive performance of oral implants has motivated manufacturers and researchers to propose more innovative and convenient treatment protocols. Simpler protocols have allowed a greater number of clinicians to provide implant treatment for a wider range of patients while maintaining a predictable treatment outcome. More recently, one of the major developments in implant prosthodontics has been the adoption of engineering principles in the form of computer-aided design and computer-aided manufacturing (CAD/CAM) to construct implant prosthesis. By reverse engineering the oral implant, it was envisioned that the prosthetic components could be designed and manufactured to a similar quality and predictability to industrial workpieces [
<xref rid="B1" ref-type="bibr">1</xref>
<xref rid="B3" ref-type="bibr">3</xref>
].</p>
<p>In industry, the benefits of computerized engineering technology include high precision, simpler fabrication protocol and minimal human intervention. These advantages make CAD/CAM ideal for quality assurance, precision production and cost effective manufacturing [
<xref rid="B3" ref-type="bibr">3</xref>
]. Because of this, it is no surprise that the CAD/CAM technology has been adopted in dentistry [
<xref rid="B1" ref-type="bibr">1</xref>
,
<xref rid="B4" ref-type="bibr">4</xref>
]. Today, CAD/CAM is the only means of producing durable tooth-colored and metal-free components in dental practice, including implant dentistry, and also provides the option of chair-side fabrication of indirect restorations. The aim of this narrative review is to critically evaluate the current knowledge regarding the rationale of CAD/CAM implant abutments and frameworks.</p>
</sec>
<sec id="sec2">
<title>2. Requirements for Implant Abutments and Frameworks</title>
<p>Implant prosthetic components should exhibit sufficient durability to withstand functional loading without distortion or fracture. In addition to functional loads, the prosthetic components are subjected to an excessive amount of preload stress following torquing the retaining screws. Therefore, implant component material should also be selected according to their ability to resist fracture in thin section. This criteria is more critical to ceramic abutments which are more brittle and susceptible to fracture in thin sections [
<xref rid="B5" ref-type="bibr">5</xref>
,
<xref rid="B6" ref-type="bibr">6</xref>
].</p>
<p>Correct external contour of implant abutments and frameworks will provide clearance for the restorative material which is needed to attain ideal aesthetics and durability of the definitive restoration [
<xref rid="B7" ref-type="bibr">7</xref>
]. Employment of an anatomical contour has been found to minimize the risk of veneering ceramic chipping [
<xref rid="B8" ref-type="bibr">8</xref>
<xref rid="B11" ref-type="bibr">11</xref>
]. Further, implant prosthetic components should exhibit a natural emergence profile that mimics natural tooth contour to support the peri-implant soft tissues [
<xref rid="B12" ref-type="bibr">12</xref>
<xref rid="B14" ref-type="bibr">14</xref>
]. Suitable soft tissue support will also facilitate successful aesthetic integration of the prosthesis.</p>
<p>In the case of the cement-retained restoration, ideal abutment geometry is required to provide resistance and retention form for the definitive dental prosthesis [
<xref rid="B15" ref-type="bibr">15</xref>
,
<xref rid="B16" ref-type="bibr">16</xref>
]. To facilitate cementation material removal, the finish line should be closely related to the soft tissue contour and follow the mucosal outline [
<xref rid="B12" ref-type="bibr">12</xref>
,
<xref rid="B13" ref-type="bibr">13</xref>
].</p>
<p>The prosthetic components should exhibit accurate fit on the implant, which implies simultaneous and even contact of all the fitting surfaces [
<xref rid="B17" ref-type="bibr">17</xref>
]. It has been proposed that an accurate fit of the implant components will minimize bacterial leakage and the strains within the implant components and the peri-implant bone. Subsequently, the biological and mechanical complications, such as bone loss and components loosening or fracture, will be reduced [
<xref rid="B17" ref-type="bibr">17</xref>
].</p>
<p>In order to endorse the long term performance of an implant restoration, the components should be biocompatible. Since the most commonly applied materials are noble metals, commercially pure titanium, titanium alloys, and ceramics (alumina and zirconia), the vast majority of patients with oral implants are served with biocompatible restorations [
<xref rid="B13" ref-type="bibr">13</xref>
]. The typical aesthetic limitation of metallic oral implant components is the greyish coloration of the mucosal tissues, especially for thin gingival biotype situations. Several authors have reported the advantage of using ceramic abutments to overcome the undesirable gingival discoloration [
<xref rid="B18" ref-type="bibr">18</xref>
,
<xref rid="B19" ref-type="bibr">19</xref>
].</p>
</sec>
<sec id="sec3">
<title>3. Traditional Methods for Constructing Implant Prostheses</title>
<p>Two traditional approaches are available for implant abutment and framework construction, namely, stock abutments and the lost wax/casting approach. Stock abutments are provided by all the implant suppliers and are milled in a similar way to an implant fixture. The available materials are commercially pure titanium, titanium alloys, and zirconia. Since stock abutments are industrially produced in well-controlled conditions, they exhibit superior durability and fit accuracy than cast abutments [
<xref rid="B20" ref-type="bibr">20</xref>
]. The fit of stock abutments was evaluated and found to have a vertical gap of 5.6 
<italic>μ</italic>
m which was about half the vertical gap of cast abutments [
<xref rid="B21" ref-type="bibr">21</xref>
]. However, customization is limited to grinding the external surface to provide clearance for the restorative material. Although this might be acceptable for titanium abutments, it has been shown to reduce the overall strength of zirconia abutments [
<xref rid="B6" ref-type="bibr">6</xref>
,
<xref rid="B22" ref-type="bibr">22</xref>
]. Likewise, the finish line is located according to average values which might not necessarily coincide with the existing mucosal contour [
<xref rid="B13" ref-type="bibr">13</xref>
,
<xref rid="B14" ref-type="bibr">14</xref>
]. Most of the stock abutments are available in cylindrical form which leaves the emergence profile modifiable only by the final crown. Subsequently, to obtain an aesthetic outcome, the margins should be deeply placed which hinders efficient cement removal. Therefore, their use should be restricted to mucosal tissues with minimal scalloping and in less aesthetically demanding situations. </p>
<p>To overcome the customization limitations of stock abutments, cast abutments have been advocated [
<xref rid="B23" ref-type="bibr">23</xref>
,
<xref rid="B24" ref-type="bibr">24</xref>
]. In the dental laboratory, the abutment or the framework is fully contoured by wax or resin and conventionally cast. To enhance the fit of the components, cast-on systems have been developed where the fitting surface is not involved in casting. However, although the casting facilitates the customization process, it is labour intensive, and a high level of quality control is mandatory. The numerous steps involved and significant temperature fluctuations have been suggested as the cause of compromised final fit [
<xref rid="B25" ref-type="bibr">25</xref>
,
<xref rid="B26" ref-type="bibr">26</xref>
]. Misfit is even further accentuated in the framework, where increasing the span of the framework increases the amount of distortion [
<xref rid="B27" ref-type="bibr">27</xref>
]. Because of this, several authors have recommended the incorporation of additional fit modifying techniques such as sectioning and soldering, laser welding, or spark erosion [
<xref rid="B28" ref-type="bibr">28</xref>
]. In addition, due to the continuously increasing cost of noble metals, the cost-efficiency of casting is questionable. Because commercial dental laboratories cannot produce implant components from high-strength ceramics, this technique is only able to provide metallic components.</p>
</sec>
<sec id="sec4">
<title>4. CAD/CAM Protocol</title>
<p>The CAD/CAM protocol was initially introduced for tooth-supported restorations for the purpose of simplicity, convenience, and elimination of several manufacturing steps [
<xref rid="B4" ref-type="bibr">4</xref>
]. CAD/CAM production involves three consecutive steps: scanning, CAD modeling, and CAM production. The scanner is the data acquisition system that records the 3D geometry of the infrastructure and converts the actual dental model into virtual dental model. The CAD component virtually designs the 3D contour of the final implant component. The CAM system produces the actual implant component according to the virtual design. In implant dentistry, the implant abutments and frameworks are produced by milling at a central production facility. Examples of these systems are Procera (Nobel Biocare), Etkon (Straumann), CAMStructure (Biomet 3i), and Atlantis (Astra Tech). </p>
<p>Custom CAD/CAM abutments combine most of the advantages of stock and cast custom abutments [
<xref rid="B29" ref-type="bibr">29</xref>
]. In addition to a predictable fit and durability, all the prosthesis parameters are modifiable including the emergence profile, thickness, finish line location, and external contour. This is performed by copying resin or wax pattern manufactured by a dental technician or by computer software modelling [
<xref rid="B29" ref-type="bibr">29</xref>
,
<xref rid="B30" ref-type="bibr">30</xref>
]. Initially, CAD/CAM was used to fabricate implant components from titanium and titanium alloy. To date, CAD/CAM is the only way of producing implant components from high-strength ceramics such as densely sintered alumina and partially stabilized zirconia.</p>
<p>In relation to implant prosthodontics, the use of CAD/CAM has three merits: accuracy (or precision of fit), durability, and simplicity of construction. Each of these points of merit are discussed as follows.</p>
<sec id="sec4.1">
<title>4.1. Accuracy</title>
<p>The assumption that CAD/CAM production is more accurate than the lost wax/casting technique is based on minimal human intervention and bypassing several fabrication steps such as waxing, investing, casting, and polishing. The literature that evaluated the accuracy of tooth-supported CAD/CAM restorations did not confirm that the accuracy of CAD/CAM copings improved when compared with conventionally produced copings [
<xref rid="B31" ref-type="bibr">31</xref>
,
<xref rid="B32" ref-type="bibr">32</xref>
]. Although the level of fit of CAD/CAM copings was within the acceptable range, a degree of misfit was reported in relation to the restoration margin and the internal fitting surface [
<xref rid="B31" ref-type="bibr">31</xref>
]. This was primarily attributed to the irregularities and variation on the prepared tooth surface that is recorded in the scanned digital image (
<xref ref-type="fig" rid="fig1">Figure 1</xref>
). From an engineering perspective, irregular surfaces are more difficult to scan which results in excessive surface noise. Subsequent image processing and noise elimination can cause rounding of the edges and loss of image sharpness [
<xref rid="B33" ref-type="bibr">33</xref>
,
<xref rid="B34" ref-type="bibr">34</xref>
]. In relation to CAM design, several authors have proposed mathematical algorithms to compute the restoration external anatomy that fits within the arch and against the opposing dentition [
<xref rid="B35" ref-type="bibr">35</xref>
,
<xref rid="B36" ref-type="bibr">36</xref>
]. Still, a discrepancy of up to 0.5 mm can be anticipated on the occlusal surface which will require manual adjustment [
<xref rid="B35" ref-type="bibr">35</xref>
]. The CAM process is dependent on the diameter of the smallest bur which is about 1 mm [
<xref rid="B30" ref-type="bibr">30</xref>
]. Restoration features with a smaller diameter might not be accurately produced. To overcome this problem, the CAD/CAM system might excessively mill the workpiece to compensate for the minor features [
<xref rid="B37" ref-type="bibr">37</xref>
].</p>
<p>On the contrary, implant CAD/CAM abutments and frameworks have been reported to be consistently better fitting than conventional cast components. In relation to implant abutments, the vertical gap for titanium and zirconia abutments was in the range of 2.5–3.2 
<italic>μ</italic>
m [
<xref rid="B38" ref-type="bibr">38</xref>
] which was comparable to stock implant abutments. The difference between milled titanium and zirconia abutments was insignificant [
<xref rid="B38" ref-type="bibr">38</xref>
]. Likewise, the rotational freedom for CAD/CAM abutments was reported to be less than 3° regardless of abutment materials [
<xref rid="B39" ref-type="bibr">39</xref>
]. With implant frameworks, CAD/CAM production has been reported to be at least as accurate as the most accurate implant framework fabrication method and with a tendency to provide the most consistent outcome [
<xref rid="B28" ref-type="bibr">28</xref>
]. This indicates the predictability of obtaining an accurate fit in comparison with other fabrication techniques. The vertical fit of CAD/CAM frameworks ranged from 1 to 27 
<italic>μ</italic>
m which was significantly better than cast implant frameworks [
<xref rid="B25" ref-type="bibr">25</xref>
,
<xref rid="B26" ref-type="bibr">26</xref>
]. In addition, a similar level of fit was observed for implant CAD/CAM frameworks produced from zirconia and titanium [
<xref rid="B40" ref-type="bibr">40</xref>
]. In contrast to the conventional casting technique, the level of precision does not seem to be affected by the span of the framework as similar levels were observed for complete and partial arch frameworks [
<xref rid="B25" ref-type="bibr">25</xref>
,
<xref rid="B26" ref-type="bibr">26</xref>
,
<xref rid="B40" ref-type="bibr">40</xref>
]. However, more studies are required to confirm this observation.</p>
<p>An engineered implant surface is advantageous in being smoothly machined with defined features that facilitates recording the exact geometry with minimal irregularities. In addition, since the implant surface is composed of defined dimensional parameters, the scanned implant surface can be reverse engineered to reproduce precise implant geometry (
<xref ref-type="fig" rid="fig2">Figure 2</xref>
). Consequently, the purpose of the scanner is to register the implant position rather than recording the surface details; eventually, there is less reliance on the acuity of the scanning procedure.</p>
<p>Regarding the external morphology of an implant, as definitive occlusal contacts are not intended to be established on implant abutments or frameworks, the external morphology is more forgiving than fully contoured restorations that are supposed to fit precisely in occlusion. Producing an implant abutment and framework with an external surface clearance is therefore simpler and more predictable than the completed restoration. Although the correct component design and clearance is determined according to the definitive restoration material, a minor discrepancy can be easily rectified in the definitive restoration with manual ceramic veneering. </p>
<p>The milling procedure is less likely to cause a fit discrepancy for implant abutments and frameworks. For an implant abutment, the ingots are available with a precisely machined fitting surface [
<xref rid="B41" ref-type="bibr">41</xref>
]. Subsequently, the milling procedure is restricted on the external surfaces without altering the precision of the fitting surface. In contrast, for implant frameworks, the fitting surfaces are produced by milling (
<xref ref-type="fig" rid="fig3">Figure 3(a)</xref>
); however, as non-engaging fitting surfaces are produced, the milling procedure will not encounter sharp edges during production. As a result, because all the fitting surface features have diameters well above the diameter of the smallest milling bur, production of an accurate fitting surface is reliably achievable (Figures
<xref ref-type="fig" rid="fig3">3(b)</xref>
and
<xref ref-type="fig" rid="fig3">3(c)</xref>
).</p>
</sec>
<sec id="sec4.2">
<title>4.2. Durability</title>
<p>The durability of CAD/CAM abutments and frameworks can be enhanced by (1) material durability and (2) design customization. The use of an industrial manufacturing process with minimal human intervention is anticipated to control the quality and reduce manufacturing deficiencies. For many years, titanium has been the gold standard due to its mechanical strength and biocompatibility. The advantages of milled titanium abutments and frameworks have been well supported by clinical studies [
<xref rid="B42" ref-type="bibr">42</xref>
,
<xref rid="B43" ref-type="bibr">43</xref>
].</p>
<p>In an aesthetic-conscious society, there is a demand for an aesthetic and durable implant restoration. This had led to the adoption of high-strength abutments and frameworks for implant prosthesis. Traditionally, the application of ceramic material in prosthodontics has been associated with more frequent mechanical complications. The advent of high-strength ceramics such as alumina and zirconia has enabled researchers to apply these materials to implant prostheses. This has been largely facilitated by the use of the CAD/CAM manufacturing process because it is the only method available to fabricate high-strength ceramics [
<xref rid="B44" ref-type="bibr">44</xref>
]. Because the durability of zirconia is superior to alumina [
<xref rid="B45" ref-type="bibr">45</xref>
,
<xref rid="B46" ref-type="bibr">46</xref>
], zirconia has attracted much more clinical attention.</p>
<p>With implant abutments, when comparing the fracture resistance of titanium and zirconia abutments in vitro, titanium abutments have been found to be more durable [
<xref rid="B22" ref-type="bibr">22</xref>
,
<xref rid="B47" ref-type="bibr">47</xref>
]. It was also found, however, that zirconia abutments were durable enough to withstand an applied occlusal load in the range of 300–460 N [
<xref rid="B22" ref-type="bibr">22</xref>
,
<xref rid="B48" ref-type="bibr">48</xref>
<xref rid="B51" ref-type="bibr">51</xref>
]. Since these values were above the maximal physiological occlusal forces on the anterior teeth, zirconia abutments were recommended for use with anterior implant restorations [
<xref rid="B8" ref-type="bibr">8</xref>
,
<xref rid="B52" ref-type="bibr">52</xref>
], where the physiologic maximal occlusal forces reach approximately 300 N. For the posterior implant restoration, the routine use of zirconia abutments needs to be validated [
<xref rid="B53" ref-type="bibr">53</xref>
,
<xref rid="B54" ref-type="bibr">54</xref>
].</p>
<p>With implant frameworks, there are currently a limited number of laboratory and clinical studies. Much of the information has been obtained from studies that used zirconia for tooth-supported fixed partial dentures. Under static loading, Kokubo et al. found that 3-unit zirconia frameworks could withstand forces ranging from 475 to 722 N [
<xref rid="B55" ref-type="bibr">55</xref>
]. The limited clinical studies have shown that zirconia frameworks are relatively stable with the complications occurring with the veneering ceramic [
<xref rid="B52" ref-type="bibr">52</xref>
]. The complications at the framework level [
<xref rid="B56" ref-type="bibr">56</xref>
] and veneering ceramic level [
<xref rid="B57" ref-type="bibr">57</xref>
] have been found to increase as the span of the prosthesis increases.</p>
<p>Zirconia abutments and frameworks benefit from full customization as this will ensure minimal zirconia adjustment and maximal material bulk for durability. Kohal et al. found that modifying the zirconia stock abutments with a diamond bur caused a decrease in the fracture strength [
<xref rid="B58" ref-type="bibr">58</xref>
]. Since CAD/CAM produces zirconia workpieces that require no subsequent alteration, unnecessary weakening is avoided. Maximal abutment and framework thickness is desirable and increases the fracture resistance. Following retrieval of fractured zirconia abutments, Aboushelib and Salameh observed that 2 out of 5 abutments fractured due to overreduction of the axial walls [
<xref rid="B6" ref-type="bibr">6</xref>
]. Further, Nguyen et al. reported that wider CAD/CAM abutments are less likely to fracture than narrower abutments [
<xref rid="B59" ref-type="bibr">59</xref>
], and Ohlmann et al. found that thickened zirconia frameworks exhibited higher fracture resistance [
<xref rid="B60" ref-type="bibr">60</xref>
]. </p>
<p>CAD/CAM production will also facilitate the durability of the veneering ceramic by contouring the zirconia abutment according to the morphology of the definitive crown [
<xref rid="B29" ref-type="bibr">29</xref>
]. Such anatomical contouring aims to reduce the thickness of the veneering ceramics and has been found to reduce the risk and severity of ceramic chipping [
<xref rid="B9" ref-type="bibr">9</xref>
<xref rid="B11" ref-type="bibr">11</xref>
]. </p>
<p>To date, the limited clinical studies have revealed a comparable outcome for zirconia and titanium abutments [
<xref rid="B61" ref-type="bibr">61</xref>
,
<xref rid="B62" ref-type="bibr">62</xref>
]; however, more data is required regarding the clinical performance of zirconia frameworks prior to the routine recommendation of zirconia prostheses. Unfortunately, clinical studies on the performance of partial- and complete-arch fixed zirconia prostheses [
<xref rid="B63" ref-type="bibr">63</xref>
,
<xref rid="B64" ref-type="bibr">64</xref>
] have revealed that the percentage of veneering ceramic failure is very high, ranging from 50% to 90% [
<xref rid="B63" ref-type="bibr">63</xref>
,
<xref rid="B64" ref-type="bibr">64</xref>
]. As a result, the authors have recommended caution prior to widespread use of zirconia for partial- and complete-arch prostheses [
<xref rid="B64" ref-type="bibr">64</xref>
]. </p>
<p>The risk of veneering ceramic fracture is expected to be minimized in the future by the continuously improving veneering strategies. Methods like heat-pressing the veneering ceramic [
<xref rid="B65" ref-type="bibr">65</xref>
,
<xref rid="B66" ref-type="bibr">66</xref>
] or slow cooling of the veneered zirconia restoration [
<xref rid="B67" ref-type="bibr">67</xref>
] are showing an encouraging outcome. On the other hand, monolithic zirconia restorations, where the implant restoration is milled to the final contour without subsequent ceramic veneering, have had an encouraging outcome in early case reports [
<xref rid="B68" ref-type="bibr">68</xref>
,
<xref rid="B69" ref-type="bibr">69</xref>
].</p>
<p>The development of CAD/CAM has occurred in parallel with material science advancement. It is therefore very likely that different aesthetic materials, such as polymer-infiltrated ceramics, will be used in the fabrication of CAD/CAM restorations [
<xref rid="B70" ref-type="bibr">70</xref>
,
<xref rid="B71" ref-type="bibr">71</xref>
]. These materials will overcome some inherent problems of ceramics such as brittleness, risk of chipping, and difficulties with reparability.</p>
</sec>
<sec id="sec4.3">
<title>4.3. Simplified Protocol</title>
<p>In comparison to the lost wax/casting protocol, CAD/CAM is much simpler and requires less technical time and involvement. This applies to the fabrication of the implant abutment and framework. The steps eliminated by CAD/CAM require more materials manipulation and precise operator handling. Instead of waxing and casting, the whole CAD/CAM process is fully automated following the scanning step. A well-designed implant CAD/CAM abutment or framework rarely requires additional intervention by the dental technician. Subsequently, the predictability of the final result of CAD/CAM will reduce the clinical time involved in evaluating the component quality. Because of this, some operators have proposed omitting the framework try-in step [
<xref rid="B25" ref-type="bibr">25</xref>
]. </p>
<p>A recently introduced CAD/CAM abutment system is the Encode abutment (Encode; Biomet 3i, Palm Beach Gardens, Fla). This system involves the utilization of a coded healing abutment that indicates the implant depth, diameter, hex orientation, location of gingival tissues, and orientation of the implant. Following a closed tray impression and master model fabrication, the model is scanned and the exact implant location is determined virtually. Subsequently, the information from the Encode abutment is used to mill a titanium or zirconia abutment. In addition, an implant analogue is fitted on the master model with the aid of a robotic system. Following cast alteration, the CAD/CAM abutment is fitted on the implant analogue and sent to the lab for definitive crown fabrication. This system has the advantages of simplicity, overcoming the open tray impression procedure, and reducing the clinic time required to take an impression [
<xref rid="B2" ref-type="bibr">2</xref>
,
<xref rid="B72" ref-type="bibr">72</xref>
<xref rid="B74" ref-type="bibr">74</xref>
]. This concept is therefore more likely to be preferred by the patient. It is speculated from clinical reports that the tissue response will be more favourable as fewer interventions are necessary, reducing the risk of tissue irritation. The manufacturer claims that correction of up to 30° implant angulation is also possible [
<xref rid="B2" ref-type="bibr">2</xref>
,
<xref rid="B73" ref-type="bibr">73</xref>
]. Further simplification was envisioned using digital intraoral scanning instead of the laboratory scanning which will omit clinical impression procedure [
<xref rid="B74" ref-type="bibr">74</xref>
,
<xref rid="B75" ref-type="bibr">75</xref>
]. This system however is only applicable to 3i implants. In addition, clinical customization of the soft tissue profile is limited [
<xref rid="B72" ref-type="bibr">72</xref>
].</p>
<p>Following the comparison of the Encode abutment impression technique and open tray implant level impression technique, Eliasson and Örtorp found that both of the techniques had minimal 3D discrepancies and rotational errors, although the open tray technique was more accurate [
<xref rid="B75" ref-type="bibr">75</xref>
]. Since the Encode system is used to fabricate individual single implant abutments, minimal orientation errors will not compromise the implant-abutment junction. Further, because the final restoration is cement-retained, any rotational errors can be compensated by the intermediate cement layer [
<xref rid="B76" ref-type="bibr">76</xref>
].</p>
<p>More recently, chair-side construction of an implant abutment can also be achieved using CAD/CAM and is available using the Cerec system (Sirona). This concept involves intraoral scanning of a prefabricated titanium cylinder followed by designing and milling a definitive zirconia abutment to the optimal contour. The zirconia abutment is adhesively bonded on the prefabricated titanium cylinder [
<xref rid="B77" ref-type="bibr">77</xref>
]. Other authors have discussed the use of a similar protocol to construct a provisional implant crown [
<xref rid="B78" ref-type="bibr">78</xref>
]. The main advantage of this system is the omission of the impression step as well as ensuring the accuracy of the prefabricated abutments.</p>
</sec>
</sec>
<sec id="sec5">
<title>5. Conclusion</title>
<p>It is indisputable that the CAD/CAM application can be used to facilitate the restoration of oral implants. The machined and evenly designed implant surface enhances the CAD/CAM performance. Precision of fit, durability, simplicity, and aesthetic material application are the main advantages of CAD/CAM in implant dentistry; however, more clinical studies are required to validate the superiority of CAD/CAM restorations. The advantages of CAD/CAM will most likely lead to an exponential growth in the utilization of this technology in implant dentistry.</p>
</sec>
</body>
<back>
<ref-list>
<ref id="B1">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kapos</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Ashy</surname>
<given-names>LM</given-names>
</name>
<name>
<surname>Gallucci</surname>
<given-names>GO</given-names>
</name>
<name>
<surname>Weber</surname>
<given-names>HP</given-names>
</name>
<name>
<surname>Wismeijer</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry</article-title>
<source>
<italic>The International Journal of Oral & Maxillofacial Implants</italic>
</source>
<year>2009</year>
<volume>24</volume>
<fpage>110</fpage>
<lpage>117</lpage>
<pub-id pub-id-type="other">2-s2.0-75549084994</pub-id>
</element-citation>
</ref>
<ref id="B2">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Priest</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>Virtual-designed and computer-milled implant abutments</article-title>
<source>
<italic>Journal of Oral and Maxillofacial Surgery</italic>
</source>
<year>2005</year>
<volume>63</volume>
<issue>9</issue>
<fpage>22</fpage>
<lpage>32</lpage>
<pub-id pub-id-type="other">2-s2.0-23944480831</pub-id>
<pub-id pub-id-type="pmid">16125013</pub-id>
</element-citation>
</ref>
<ref id="B3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>van Noort</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>The future of dental devices is digital</article-title>
<source>
<italic>Dental Materials</italic>
</source>
<year>2012</year>
<volume>28</volume>
<issue>1</issue>
<fpage>3</fpage>
<lpage>12</lpage>
<pub-id pub-id-type="pmid">22119539</pub-id>
</element-citation>
</ref>
<ref id="B4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Miyazaki</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Hotta</surname>
<given-names>Y</given-names>
</name>
</person-group>
<article-title>CAD/CAM systems available for the fabrication of crown and bridge restorations</article-title>
<source>
<italic>Australian Dental Journal</italic>
</source>
<year>2011</year>
<volume>56</volume>
<issue>1</issue>
<fpage>97</fpage>
<lpage>106</lpage>
<pub-id pub-id-type="other">2-s2.0-79956140254</pub-id>
</element-citation>
</ref>
<ref id="B5">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sailer</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Sailer</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Stawarczyk</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Jung</surname>
<given-names>RE</given-names>
</name>
<name>
<surname>Hämmerle</surname>
<given-names>CH</given-names>
</name>
</person-group>
<article-title>In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections</article-title>
<source>
<italic>The International Journal of Oral & Maxillofacial Implants</italic>
</source>
<year>2009</year>
<volume>24</volume>
<issue>5</issue>
<fpage>850</fpage>
<lpage>858</lpage>
<pub-id pub-id-type="other">2-s2.0-77649205115</pub-id>
<pub-id pub-id-type="pmid">19865625</pub-id>
</element-citation>
</ref>
<ref id="B6">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aboushelib</surname>
<given-names>MN</given-names>
</name>
<name>
<surname>Salameh</surname>
<given-names>Z</given-names>
</name>
</person-group>
<article-title>Zirconia implant abutment fracture: clinical case reports and precautions for use</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2009</year>
<volume>22</volume>
<issue>6</issue>
<fpage>616</fpage>
<lpage>619</lpage>
<pub-id pub-id-type="other">2-s2.0-77449097691</pub-id>
<pub-id pub-id-type="pmid">19918599</pub-id>
</element-citation>
</ref>
<ref id="B7">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goodacre</surname>
<given-names>CJ</given-names>
</name>
<name>
<surname>Campagni</surname>
<given-names>WV</given-names>
</name>
<name>
<surname>Aquilino</surname>
<given-names>SA</given-names>
</name>
</person-group>
<article-title>Tooth preparations for complete crowns: an art form based on scientific principles</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2001</year>
<volume>85</volume>
<issue>4</issue>
<fpage>363</fpage>
<lpage>376</lpage>
<pub-id pub-id-type="other">2-s2.0-0035318605</pub-id>
<pub-id pub-id-type="pmid">11319534</pub-id>
</element-citation>
</ref>
<ref id="B8">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Guess</surname>
<given-names>PC</given-names>
</name>
<name>
<surname>Att</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Strub</surname>
<given-names>JR</given-names>
</name>
</person-group>
<article-title>Zirconia in fixed implant prosthodontics</article-title>
<source>
<italic>Clinical Implant Dentistry and Related Research</italic>
</source>
<year>2012</year>
<volume>14</volume>
<issue>5</issue>
<fpage>633</fpage>
<lpage>645</lpage>
<pub-id pub-id-type="pmid">21176095</pub-id>
</element-citation>
</ref>
<ref id="B9">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Silva</surname>
<given-names>NRFA</given-names>
</name>
<name>
<surname>Bonfante</surname>
<given-names>EA</given-names>
</name>
<name>
<surname>Rafferty</surname>
<given-names>BT</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Modified Y-TZP core design improves all-ceramic crown reliability</article-title>
<source>
<italic>Journal of Dental Research</italic>
</source>
<year>2011</year>
<volume>90</volume>
<issue>1</issue>
<fpage>104</fpage>
<lpage>108</lpage>
<pub-id pub-id-type="other">2-s2.0-78650994904</pub-id>
<pub-id pub-id-type="pmid">21057036</pub-id>
</element-citation>
</ref>
<ref id="B10">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kokubo</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Tsumita</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Kano</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Fukushima</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>The influence of zirconia coping designs on the fracture load of all-ceramic molar crowns</article-title>
<source>
<italic>Dental Materials Journal</italic>
</source>
<year>2011</year>
<volume>30</volume>
<issue>3</issue>
<fpage>281</fpage>
<lpage>285</lpage>
<pub-id pub-id-type="other">2-s2.0-79958031463</pub-id>
<pub-id pub-id-type="pmid">21597222</pub-id>
</element-citation>
</ref>
<ref id="B11">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Guess</surname>
<given-names>PC</given-names>
</name>
<name>
<surname>Bonfante</surname>
<given-names>EA</given-names>
</name>
<name>
<surname>Silva</surname>
<given-names>NR</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns</article-title>
<source>
<italic>Dental Materials</italic>
</source>
<year>2013</year>
<volume>29</volume>
<issue>3</issue>
<fpage>307</fpage>
<lpage>316</lpage>
<pub-id pub-id-type="pmid">23228337</pub-id>
</element-citation>
</ref>
<ref id="B12">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Furze</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Byrne</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Donos</surname>
<given-names>N</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Clinical and esthetic outcomes of single-tooth implants in the anterior maxilla</article-title>
<source>
<italic>Quintessence International</italic>
</source>
<year>2012</year>
<volume>43</volume>
<issue>2</issue>
<fpage>127</fpage>
<lpage>134</lpage>
<pub-id pub-id-type="pmid">22257874</pub-id>
</element-citation>
</ref>
<ref id="B13">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chee</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Jivraj</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Designing abutments for cement retained implant supported restorations</article-title>
<source>
<italic>British Dental Journal</italic>
</source>
<year>2006</year>
<volume>201</volume>
<issue>9</issue>
<fpage>559</fpage>
<lpage>563</lpage>
<pub-id pub-id-type="other">2-s2.0-33750931559</pub-id>
<pub-id pub-id-type="pmid">17099660</pub-id>
</element-citation>
</ref>
<ref id="B14">
<label>14</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sailer</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Zembic</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Jung</surname>
<given-names>RE</given-names>
</name>
<name>
<surname>Hämmerle</surname>
<given-names>CH</given-names>
</name>
<name>
<surname>Mattiola</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Single-tooth implant reconstructions: esthetic factors influencing the decision between titanium and zirconia abutments in anterior regions</article-title>
<source>
<italic>The European Journal of Esthetic Dentistry</italic>
</source>
<year>2007</year>
<volume>2</volume>
<issue>3</issue>
<fpage>296</fpage>
<lpage>310</lpage>
<pub-id pub-id-type="other">2-s2.0-70349232916</pub-id>
<pub-id pub-id-type="pmid">19655552</pub-id>
</element-citation>
</ref>
<ref id="B15">
<label>15</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bernal</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Okamura</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Muñoz</surname>
<given-names>CA</given-names>
</name>
</person-group>
<article-title>The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations</article-title>
<source>
<italic>Journal of Prosthodontics</italic>
</source>
<year>2003</year>
<volume>12</volume>
<issue>2</issue>
<fpage>111</fpage>
<lpage>115</lpage>
<pub-id pub-id-type="other">2-s2.0-0642311345</pub-id>
<pub-id pub-id-type="pmid">12964683</pub-id>
</element-citation>
</ref>
<ref id="B16">
<label>16</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cano-Batalla</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Soliva-Garriga</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Campillo-Funollet</surname>
<given-names>M</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Influence of abutment height and surface roughness on in vitro retention of three luting agents</article-title>
<source>
<italic>The International Journal of Oral & Maxillofacial Implants</italic>
</source>
<year>2012</year>
<volume>27</volume>
<issue>1</issue>
<fpage>36</fpage>
<lpage>41</lpage>
<pub-id pub-id-type="pmid">22299076</pub-id>
</element-citation>
</ref>
<ref id="B17">
<label>17</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abduo</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Bennani</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Waddell</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Lyons</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Swain</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Assessing the fit of implant fixed prostheses: a critical review</article-title>
<source>
<italic>The International Journal of Oral & Maxillofacial Implants</italic>
</source>
<year>2010</year>
<volume>25</volume>
<issue>3</issue>
<fpage>506</fpage>
<lpage>515</lpage>
<pub-id pub-id-type="other">2-s2.0-77955855691</pub-id>
<pub-id pub-id-type="pmid">20556249</pub-id>
</element-citation>
</ref>
<ref id="B18">
<label>18</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Heydecke</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Sierraalta</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Razzoog</surname>
<given-names>ME</given-names>
</name>
</person-group>
<article-title>Evolution and use of aluminum oxide single-tooth implant abutments: a short review and presentation of two cases</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2002</year>
<volume>15</volume>
<issue>5</issue>
<fpage>488</fpage>
<lpage>493</lpage>
<pub-id pub-id-type="other">2-s2.0-0036715935</pub-id>
<pub-id pub-id-type="pmid">12375466</pub-id>
</element-citation>
</ref>
<ref id="B19">
<label>19</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kohal</surname>
<given-names>RJ</given-names>
</name>
<name>
<surname>Att</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Bächle</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Butz</surname>
<given-names>F</given-names>
</name>
</person-group>
<article-title>Ceramic abutments and ceramic oral implants. An update</article-title>
<source>
<italic>Periodontology 2000</italic>
</source>
<year>2008</year>
<volume>47</volume>
<issue>1</issue>
<fpage>224</fpage>
<lpage>243</lpage>
<pub-id pub-id-type="other">2-s2.0-42149131820</pub-id>
<pub-id pub-id-type="pmid">18412584</pub-id>
</element-citation>
</ref>
<ref id="B20">
<label>20</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Byrne</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Houston</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Cleary</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Claffey</surname>
<given-names>N</given-names>
</name>
</person-group>
<article-title>The fit of cast and premachined implant abutments</article-title>
<source>
<italic>The Journal of Prosthetic Dentistry</italic>
</source>
<year>1998</year>
<volume>80</volume>
<issue>2</issue>
<fpage>184</fpage>
<lpage>192</lpage>
<pub-id pub-id-type="other">2-s2.0-0032139016</pub-id>
<pub-id pub-id-type="pmid">9710820</pub-id>
</element-citation>
</ref>
<ref id="B21">
<label>21</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kano</surname>
<given-names>SC</given-names>
</name>
<name>
<surname>Binon</surname>
<given-names>PP</given-names>
</name>
<name>
<surname>Curtis</surname>
<given-names>DA</given-names>
</name>
</person-group>
<article-title>A classification system to measure the implant-abutment microgap</article-title>
<source>
<italic>International Journal of Oral and Maxillofacial Implants</italic>
</source>
<year>2007</year>
<volume>22</volume>
<issue>6</issue>
<fpage>879</fpage>
<lpage>885</lpage>
<pub-id pub-id-type="other">2-s2.0-38149016092</pub-id>
<pub-id pub-id-type="pmid">18271368</pub-id>
</element-citation>
</ref>
<ref id="B22">
<label>22</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Att</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Yajima</surname>
<given-names>ND</given-names>
</name>
<name>
<surname>Wolkewitz</surname>
<given-names>M</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Influence of preparation and wall thickness on the resistance to fracture of zirconia implant abutments</article-title>
<source>
<italic>Clinical Implant Dentistry and Related Research</italic>
</source>
<year>2012</year>
<volume>14</volume>
<fpage>196</fpage>
<lpage>203</lpage>
</element-citation>
</ref>
<ref id="B23">
<label>23</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Taylor</surname>
<given-names>TD</given-names>
</name>
<name>
<surname>Agar</surname>
<given-names>JR</given-names>
</name>
</person-group>
<article-title>Twenty years of progress in implant prosthodontics</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2002</year>
<volume>88</volume>
<issue>1</issue>
<fpage>89</fpage>
<lpage>95</lpage>
<pub-id pub-id-type="other">2-s2.0-0036632491</pub-id>
<pub-id pub-id-type="pmid">12239483</pub-id>
</element-citation>
</ref>
<ref id="B24">
<label>24</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lewis</surname>
<given-names>SG</given-names>
</name>
<name>
<surname>Beumer 3rd. J.</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Perri</surname>
<given-names>GR</given-names>
</name>
<name>
<surname>Hornburg</surname>
<given-names>WP</given-names>
</name>
</person-group>
<article-title>Single tooth implant supported restorations</article-title>
<source>
<italic>The International Journal of Oral & Maxillofacial Implants</italic>
</source>
<year>1988</year>
<volume>3</volume>
<issue>1</issue>
<fpage>25</fpage>
<lpage>30</lpage>
<pub-id pub-id-type="other">2-s2.0-0023977677</pub-id>
<pub-id pub-id-type="pmid">3074952</pub-id>
</element-citation>
</ref>
<ref id="B25">
<label>25</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Örtorp</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Bäck</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Jälevik</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2003</year>
<volume>16</volume>
<issue>2</issue>
<fpage>194</fpage>
<lpage>200</lpage>
<pub-id pub-id-type="other">2-s2.0-0038488528</pub-id>
<pub-id pub-id-type="pmid">12737254</pub-id>
</element-citation>
</ref>
<ref id="B26">
<label>26</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Takahashi</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Gunne</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>Fit of implant frameworks: an in vitro comparison between two fabrication techniques</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2003</year>
<volume>89</volume>
<issue>3</issue>
<fpage>256</fpage>
<lpage>260</lpage>
<pub-id pub-id-type="other">2-s2.0-0037629996</pub-id>
<pub-id pub-id-type="pmid">12644800</pub-id>
</element-citation>
</ref>
<ref id="B27">
<label>27</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Bäck</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Petersson</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>1999</year>
<volume>12</volume>
<issue>3</issue>
<fpage>209</fpage>
<lpage>215</lpage>
<pub-id pub-id-type="other">2-s2.0-0033122309</pub-id>
<pub-id pub-id-type="pmid">10635187</pub-id>
</element-citation>
</ref>
<ref id="B28">
<label>28</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abduo</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Lyons</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Bennani</surname>
<given-names>V</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Fit of screw-retained fixed implant frameworks fabricated by different methods: a systematic review</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2011</year>
<volume>24</volume>
<issue>3</issue>
<fpage>207</fpage>
<lpage>220</lpage>
<pub-id pub-id-type="pmid">21519567</pub-id>
</element-citation>
</ref>
<ref id="B29">
<label>29</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Parpaiola</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Norton</surname>
<given-names>MR</given-names>
</name>
<name>
<surname>Cecchinato</surname>
<given-names>D</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Virtual abutment design: a concept for delivery of CAD/CAM customized abutments- report of a retrospective cohort</article-title>
<source>
<italic>The International Journal of Periodontics & Restorative Dentistry</italic>
</source>
<year>2013</year>
<volume>33</volume>
<issue>1</issue>
<fpage>51</fpage>
<lpage>58</lpage>
<pub-id pub-id-type="pmid">23342347</pub-id>
</element-citation>
</ref>
<ref id="B30">
<label>30</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Beuer</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Schweiger</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Edelhoff</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>Digital dentistry: an overview of recent developments for CAD/CAM generated restorations</article-title>
<source>
<italic>British Dental Journal</italic>
</source>
<year>2008</year>
<volume>204</volume>
<issue>9</issue>
<fpage>505</fpage>
<lpage>511</lpage>
<pub-id pub-id-type="other">2-s2.0-44249116685</pub-id>
<pub-id pub-id-type="pmid">18469768</pub-id>
</element-citation>
</ref>
<ref id="B31">
<label>31</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abduo</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Lyons</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Swain</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Fit of zirconia fixed partial denture: a systematic review</article-title>
<source>
<italic>Journal of Oral Rehabilitation</italic>
</source>
<year>2010</year>
<volume>37</volume>
<issue>11</issue>
<fpage>866</fpage>
<lpage>876</lpage>
<pub-id pub-id-type="other">2-s2.0-77958090670</pub-id>
<pub-id pub-id-type="pmid">20557435</pub-id>
</element-citation>
</ref>
<ref id="B32">
<label>32</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tan</surname>
<given-names>PL</given-names>
</name>
<name>
<surname>Gratton</surname>
<given-names>DG</given-names>
</name>
<name>
<surname>Diaz-Arnold</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Holmes</surname>
<given-names>DC</given-names>
</name>
</person-group>
<article-title>An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations</article-title>
<source>
<italic>Journal of Prosthodontics</italic>
</source>
<year>2008</year>
<volume>17</volume>
<issue>5</issue>
<fpage>378</fpage>
<lpage>383</lpage>
<pub-id pub-id-type="other">2-s2.0-47249089599</pub-id>
<pub-id pub-id-type="pmid">18355167</pub-id>
</element-citation>
</ref>
<ref id="B33">
<label>33</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Thompson</surname>
<given-names>WB</given-names>
</name>
<name>
<surname>Owen</surname>
<given-names>JC</given-names>
</name>
<name>
<surname>De</surname>
<given-names>SG</given-names>
</name>
<name>
<surname>Stark</surname>
<given-names>SR</given-names>
</name>
<name>
<surname>Henderson</surname>
<given-names>TC</given-names>
</name>
</person-group>
<article-title>Feature-based reverse engineering of mechanical parts</article-title>
<source>
<italic>IEEE Transactions on Robotics and Automation</italic>
</source>
<year>1999</year>
<volume>15</volume>
<issue>1</issue>
<fpage>57</fpage>
<lpage>66</lpage>
<pub-id pub-id-type="other">2-s2.0-0033078814</pub-id>
</element-citation>
</ref>
<ref id="B34">
<label>34</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Persson</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Andersson</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Oden</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Sandborgh-Englund</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>A three-dimensional evaluation of a laser scanner and a touch-probe scanner</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2006</year>
<volume>95</volume>
<issue>3</issue>
<fpage>194</fpage>
<lpage>200</lpage>
<pub-id pub-id-type="other">2-s2.0-33644920407</pub-id>
<pub-id pub-id-type="pmid">16543016</pub-id>
</element-citation>
</ref>
<ref id="B35">
<label>35</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ender</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Mörmann</surname>
<given-names>WH</given-names>
</name>
<name>
<surname>Mehl</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Efficiency of a mathematical model in generating CAD/CAM-partial crowns with natural tooth morphology</article-title>
<source>
<italic>Clinical Oral Investigations</italic>
</source>
<year>2011</year>
<volume>15</volume>
<issue>2</issue>
<fpage>283</fpage>
<lpage>289</lpage>
<pub-id pub-id-type="other">2-s2.0-79952628718</pub-id>
<pub-id pub-id-type="pmid">20143242</pub-id>
</element-citation>
</ref>
<ref id="B36">
<label>36</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mehl</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Blanz</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Hickel</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Biogeneric tooth: a new mathematical representation for tooth morphology in lower first molars</article-title>
<source>
<italic>European Journal of Oral Sciences</italic>
</source>
<year>2005</year>
<volume>113</volume>
<issue>4</issue>
<fpage>333</fpage>
<lpage>340</lpage>
<pub-id pub-id-type="other">2-s2.0-23844443816</pub-id>
<pub-id pub-id-type="pmid">16048526</pub-id>
</element-citation>
</ref>
<ref id="B37">
<label>37</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Örtorp</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Jönsson</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Mouhsen</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Vult Von Steyern</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study</article-title>
<source>
<italic>Dental Materials</italic>
</source>
<year>2011</year>
<volume>27</volume>
<issue>4</issue>
<fpage>356</fpage>
<lpage>363</lpage>
<pub-id pub-id-type="other">2-s2.0-79952283407</pub-id>
<pub-id pub-id-type="pmid">21163516</pub-id>
</element-citation>
</ref>
<ref id="B38">
<label>38</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yüzügüllü</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Avci</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>The implant-abutment interface of alumina and zirconia abutments</article-title>
<source>
<italic>Clinical Implant Dentistry and Related Research</italic>
</source>
<year>2008</year>
<volume>10</volume>
<issue>2</issue>
<fpage>113</fpage>
<lpage>121</lpage>
<pub-id pub-id-type="other">2-s2.0-43249095032</pub-id>
<pub-id pub-id-type="pmid">18218054</pub-id>
</element-citation>
</ref>
<ref id="B39">
<label>39</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vigolo</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Fonzi</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Majzoub</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Cordioli</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection</article-title>
<source>
<italic>International Journal of Oral and Maxillofacial Implants</italic>
</source>
<year>2006</year>
<volume>21</volume>
<issue>4</issue>
<fpage>575</fpage>
<lpage>580</lpage>
<pub-id pub-id-type="other">2-s2.0-33748509101</pub-id>
<pub-id pub-id-type="pmid">16955608</pub-id>
</element-citation>
</ref>
<ref id="B40">
<label>40</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abduo</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Lyons</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Waddell</surname>
<given-names>N</given-names>
</name>
<etal></etal>
</person-group>
<article-title>A comparison of fit of CNC-milled titanium and zirconia frameworks to implants</article-title>
<source>
<italic>Clinical Implant Dentistry and Related Research</italic>
</source>
<year>2012</year>
<volume>14</volume>
<fpage>20</fpage>
<lpage>29</lpage>
</element-citation>
</ref>
<ref id="B41">
<label>41</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Glauser</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Sailer</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Wohlwend</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Studer</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Schibli</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Schärer</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-Year results of a prospective clinical study</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2004</year>
<volume>17</volume>
<issue>3</issue>
<fpage>285</fpage>
<lpage>290</lpage>
<pub-id pub-id-type="other">2-s2.0-2542639442</pub-id>
<pub-id pub-id-type="pmid">15237873</pub-id>
</element-citation>
</ref>
<ref id="B42">
<label>42</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>Single implants in the anterior maxilla after 15 years of follow-up: comparison with central implants in the edentulous maxilla</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2008</year>
<volume>21</volume>
<issue>5</issue>
<fpage>400</fpage>
<lpage>408</lpage>
<pub-id pub-id-type="other">2-s2.0-53749101824</pub-id>
<pub-id pub-id-type="pmid">18950060</pub-id>
</element-citation>
</ref>
<ref id="B43">
<label>43</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ortorp</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10-year comparative clinical study</article-title>
<source>
<italic>Clinical Implant Dentistry and Related Research</italic>
</source>
<year>2012</year>
<volume>14</volume>
<issue>1</issue>
<fpage>88</fpage>
<lpage>99</lpage>
<pub-id pub-id-type="pmid">19686283</pub-id>
</element-citation>
</ref>
<ref id="B44">
<label>44</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Denry</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Kelly</surname>
<given-names>JR</given-names>
</name>
</person-group>
<article-title>State of the art of zirconia for dental applications</article-title>
<source>
<italic>Dental Materials</italic>
</source>
<year>2008</year>
<volume>24</volume>
<issue>3</issue>
<fpage>299</fpage>
<lpage>307</lpage>
<pub-id pub-id-type="other">2-s2.0-38349192796</pub-id>
<pub-id pub-id-type="pmid">17659331</pub-id>
</element-citation>
</ref>
<ref id="B45">
<label>45</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yildirim</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Fischer</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Marx</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Edelhoff</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>In vivo fracture resistance of implant-supported all-ceramic restorations</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2003</year>
<volume>90</volume>
<issue>4</issue>
<fpage>325</fpage>
<lpage>331</lpage>
<pub-id pub-id-type="other">2-s2.0-0141923180</pub-id>
<pub-id pub-id-type="pmid">14564286</pub-id>
</element-citation>
</ref>
<ref id="B46">
<label>46</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kerstein</surname>
<given-names>RB</given-names>
</name>
<name>
<surname>Radke</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments</article-title>
<source>
<italic>International Journal of Oral and Maxillofacial Implants</italic>
</source>
<year>2008</year>
<volume>23</volume>
<issue>6</issue>
<fpage>1029</fpage>
<lpage>1036</lpage>
<pub-id pub-id-type="other">2-s2.0-66149129216</pub-id>
<pub-id pub-id-type="pmid">19216271</pub-id>
</element-citation>
</ref>
<ref id="B47">
<label>47</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hosseini</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Kleven</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Gotfredsen</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Fracture mode during cyclic loading of implant-supported single-tooth restorations</article-title>
<source>
<italic>The Journal of Prosthetic Dentistry</italic>
</source>
<year>2012</year>
<volume>108</volume>
<issue>2</issue>
<fpage>74</fpage>
<lpage>83</lpage>
<pub-id pub-id-type="pmid">22867804</pub-id>
</element-citation>
</ref>
<ref id="B48">
<label>48</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aramouni</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Zebouni</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Tashkandi</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Dib</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Salameh</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Almas</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Fracture resistance and failure location of zirconium and metallic implant abutments</article-title>
<source>
<italic>Journal of Contemporary Dental Practice</italic>
</source>
<year>2008</year>
<volume>9</volume>
<issue>7</issue>
<fpage>41</fpage>
<lpage>48</lpage>
<pub-id pub-id-type="other">2-s2.0-55849150169</pub-id>
</element-citation>
</ref>
<ref id="B49">
<label>49</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Butz</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Heydecke</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Okutan</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Strub</surname>
<given-names>JR</given-names>
</name>
</person-group>
<article-title>Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation</article-title>
<source>
<italic>Journal of Oral Rehabilitation</italic>
</source>
<year>2005</year>
<volume>32</volume>
<issue>11</issue>
<fpage>838</fpage>
<lpage>843</lpage>
<pub-id pub-id-type="other">2-s2.0-27344446978</pub-id>
<pub-id pub-id-type="pmid">16202048</pub-id>
</element-citation>
</ref>
<ref id="B50">
<label>50</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Att</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Kurun</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Gerds</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Strub</surname>
<given-names>JR</given-names>
</name>
</person-group>
<article-title>Fracture resistance of single-tooth implant-supported all-ceramic restorations after exposure to the artificial mouth</article-title>
<source>
<italic>Journal of Oral Rehabilitation</italic>
</source>
<year>2006</year>
<volume>33</volume>
<issue>5</issue>
<fpage>380</fpage>
<lpage>386</lpage>
<pub-id pub-id-type="other">2-s2.0-33645841934</pub-id>
<pub-id pub-id-type="pmid">16629897</pub-id>
</element-citation>
</ref>
<ref id="B51">
<label>51</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Att</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Kurun</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Gerds</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Strub</surname>
<given-names>JR</given-names>
</name>
</person-group>
<article-title>Fracture resistance of single-tooth implant-supported all-ceramic restorations: an in vitro study</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2006</year>
<volume>95</volume>
<issue>2</issue>
<fpage>111</fpage>
<lpage>116</lpage>
<pub-id pub-id-type="other">2-s2.0-32244447142</pub-id>
<pub-id pub-id-type="pmid">16473084</pub-id>
</element-citation>
</ref>
<ref id="B52">
<label>52</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sailer</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Pjetursson</surname>
<given-names>BE</given-names>
</name>
<name>
<surname>Zwahlen</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Hämmerle</surname>
<given-names>CHF</given-names>
</name>
</person-group>
<article-title>A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2007</year>
<volume>18</volume>
<issue>3</issue>
<fpage>86</fpage>
<lpage>96</lpage>
<pub-id pub-id-type="other">2-s2.0-34250665803</pub-id>
</element-citation>
</ref>
<ref id="B53">
<label>53</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Haraldson</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Carlsson</surname>
<given-names>GE</given-names>
</name>
<name>
<surname>Ingervall</surname>
<given-names>B</given-names>
</name>
</person-group>
<article-title>Functional state, bite force and postural muscle activity in patients with osseointegrated oral implant bridges</article-title>
<source>
<italic>Acta Odontologica Scandinavica</italic>
</source>
<year>1979</year>
<volume>37</volume>
<issue>4</issue>
<fpage>195</fpage>
<lpage>206</lpage>
<pub-id pub-id-type="other">2-s2.0-0018322406</pub-id>
<pub-id pub-id-type="pmid">291276</pub-id>
</element-citation>
</ref>
<ref id="B54">
<label>54</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kiliaridis</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Kjellberg</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Wenneberg</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Engström</surname>
<given-names>C</given-names>
</name>
</person-group>
<article-title>The relationship between maximal bite force, bite force endurance, and facial morphology during growth. A cross-sectional study</article-title>
<source>
<italic>Acta Odontologica Scandinavica</italic>
</source>
<year>1993</year>
<volume>51</volume>
<issue>5</issue>
<fpage>323</fpage>
<lpage>331</lpage>
<pub-id pub-id-type="other">2-s2.0-0027673898</pub-id>
<pub-id pub-id-type="pmid">8279273</pub-id>
</element-citation>
</ref>
<ref id="B55">
<label>55</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kokubo</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Tsumita</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Sakurai</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Torizuka</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Vult Von Steyern</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Fukushima</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>The effect of core framework designs on the fracture loads of all-ceramic fixed partial dentures on posterior implants</article-title>
<source>
<italic>Journal of Oral Rehabilitation</italic>
</source>
<year>2007</year>
<volume>34</volume>
<issue>7</issue>
<fpage>503</fpage>
<lpage>507</lpage>
<pub-id pub-id-type="other">2-s2.0-34250199778</pub-id>
<pub-id pub-id-type="pmid">17559618</pub-id>
</element-citation>
</ref>
<ref id="B56">
<label>56</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schmitter</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Mussotter</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Rammelsberg</surname>
<given-names>P</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Clinical performance of long-span zirconia frameworks for fixed dental prostheses: 5-year results</article-title>
<source>
<italic>Journal of Oral Rehabilitation</italic>
</source>
<year>2012</year>
<volume>39</volume>
<issue>7</issue>
<fpage>552</fpage>
<lpage>557</lpage>
<pub-id pub-id-type="pmid">22574689</pub-id>
</element-citation>
</ref>
<ref id="B57">
<label>57</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sax</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Hammerle</surname>
<given-names>CH</given-names>
</name>
<name>
<surname>Sailer</surname>
<given-names>I</given-names>
</name>
</person-group>
<article-title>10-year clinical outcomes of fixed dental prostheses with zirconia frameworks</article-title>
<source>
<italic>International Journal of Computerized Dentistry</italic>
</source>
<year>2011</year>
<volume>14</volume>
<issue>3</issue>
<fpage>183</fpage>
<lpage>202</lpage>
<pub-id pub-id-type="pmid">22141229</pub-id>
</element-citation>
</ref>
<ref id="B58">
<label>58</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kohal</surname>
<given-names>RJ</given-names>
</name>
<name>
<surname>Wolkewitz</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Mueller</surname>
<given-names>C</given-names>
</name>
</person-group>
<article-title>Alumina-reinforced zirconia implants: survival rate and fracture strength in a masticatory simulation trial</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2010</year>
<volume>21</volume>
<issue>12</issue>
<fpage>1345</fpage>
<lpage>1352</lpage>
<pub-id pub-id-type="other">2-s2.0-78349264271</pub-id>
<pub-id pub-id-type="pmid">20626420</pub-id>
</element-citation>
</ref>
<ref id="B59">
<label>59</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nguyen</surname>
<given-names>HQ</given-names>
</name>
<name>
<surname>Tan</surname>
<given-names>KB</given-names>
</name>
<name>
<surname>Nicholls</surname>
<given-names>JI</given-names>
</name>
</person-group>
<article-title>Load fatigue performance of implant-ceramic abutment combinations</article-title>
<source>
<italic>The International Journal of Oral & Maxillofacial Implants</italic>
</source>
<year>2009</year>
<volume>24</volume>
<issue>4</issue>
<fpage>636</fpage>
<lpage>646</lpage>
<pub-id pub-id-type="other">2-s2.0-73349086590</pub-id>
<pub-id pub-id-type="pmid">19885403</pub-id>
</element-citation>
</ref>
<ref id="B60">
<label>60</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ohlmann</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Marienburg</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Gabbert</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Hassel</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Gilde</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Rammelsberg</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Fracture-load values of all-ceramic cantilevered fpds with different framework designs</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2009</year>
<volume>22</volume>
<issue>1</issue>
<fpage>49</fpage>
<lpage>52</lpage>
<pub-id pub-id-type="other">2-s2.0-65549160466</pub-id>
<pub-id pub-id-type="pmid">19260427</pub-id>
</element-citation>
</ref>
<ref id="B61">
<label>61</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ekfeldt</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Furst</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Carlsson</surname>
<given-names>GE</given-names>
</name>
</person-group>
<article-title>Zirconia abutments for single-tooth implant restorations: a retrospective and clinical follow-up study</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2011</year>
<volume>22</volume>
<issue>11</issue>
<fpage>1308</fpage>
<lpage>1314</lpage>
<pub-id pub-id-type="pmid">21382085</pub-id>
</element-citation>
</ref>
<ref id="B62">
<label>62</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sailer</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Philipp</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Zembic</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Pjetursson</surname>
<given-names>BE</given-names>
</name>
<name>
<surname>Hämmerle</surname>
<given-names>CHF</given-names>
</name>
<name>
<surname>Zwahlen</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2009</year>
<volume>20</volume>
<issue>4</issue>
<fpage>4</fpage>
<lpage>31</lpage>
<pub-id pub-id-type="other">2-s2.0-68549092603</pub-id>
<pub-id pub-id-type="pmid">19663946</pub-id>
</element-citation>
</ref>
<ref id="B63">
<label>63</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Larsson</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Vult von Steyern</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Nilner</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2010</year>
<volume>23</volume>
<issue>4</issue>
<fpage>364</fpage>
<lpage>369</lpage>
<pub-id pub-id-type="other">2-s2.0-77957270939</pub-id>
<pub-id pub-id-type="pmid">20617228</pub-id>
</element-citation>
</ref>
<ref id="B64">
<label>64</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Larsson</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Vult von Steyern</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Five-year follow-up of implant-supported Y-TZP and ZTA fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>2010</year>
<volume>23</volume>
<issue>6</issue>
<fpage>555</fpage>
<lpage>561</lpage>
<pub-id pub-id-type="other">2-s2.0-79952260010</pub-id>
<pub-id pub-id-type="pmid">21209993</pub-id>
</element-citation>
</ref>
<ref id="B65">
<label>65</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>JH</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>SJ</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>JS</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Fracture load of monolithic CAD/CAM lithium disilicate ceramic crowns and veneered zirconia crowns as a posterior implant restoration</article-title>
<source>
<italic>Implant Dentistry</italic>
</source>
<year>2013</year>
<volume>22</volume>
<issue>1</issue>
<fpage>66</fpage>
<lpage>70</lpage>
<pub-id pub-id-type="pmid">23296031</pub-id>
</element-citation>
</ref>
<ref id="B66">
<label>66</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Karl</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Graef</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Wichmann</surname>
<given-names>M</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Microfractures in metal-ceramic and all-ceramic implant-supported fixed dental prostheses caused by superstructure fixation</article-title>
<source>
<italic>Dental Materials Journal</italic>
</source>
<year>2012</year>
<volume>31</volume>
<issue>3</issue>
<fpage>338</fpage>
<lpage>345</lpage>
<pub-id pub-id-type="pmid">22673463</pub-id>
</element-citation>
</ref>
<ref id="B67">
<label>67</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Swain</surname>
<given-names>MV</given-names>
</name>
</person-group>
<article-title>Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures</article-title>
<source>
<italic>Acta Biomaterialia</italic>
</source>
<year>2009</year>
<volume>5</volume>
<issue>5</issue>
<fpage>1668</fpage>
<lpage>1677</lpage>
<pub-id pub-id-type="other">2-s2.0-67349133480</pub-id>
<pub-id pub-id-type="pmid">19201268</pub-id>
</element-citation>
</ref>
<ref id="B68">
<label>68</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rojas-Vizcaya</surname>
<given-names>F</given-names>
</name>
</person-group>
<article-title>Full zirconia fixed detachable implant-retained restorations manufactured from monolithic zirconia: clinical report after two years in service</article-title>
<source>
<italic>Journal of Prosthodontics</italic>
</source>
<year>2011</year>
<volume>20</volume>
<issue>7</issue>
<fpage>570</fpage>
<lpage>576</lpage>
<pub-id pub-id-type="pmid">22003832</pub-id>
</element-citation>
</ref>
<ref id="B69">
<label>69</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sorensen</surname>
<given-names>JA</given-names>
</name>
</person-group>
<article-title>CAD/CAM: converging technologies, improved milling materials expand dental applications</article-title>
<source>
<italic>Compendium of Continuing Education in Dentistry</italic>
</source>
<year>2012</year>
<volume>33</volume>
<issue>7</issue>
<fpage>538</fpage>
<lpage>539</lpage>
<pub-id pub-id-type="pmid">22908602</pub-id>
</element-citation>
</ref>
<ref id="B70">
<label>70</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Coldea</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Swain</surname>
<given-names>MV</given-names>
</name>
<name>
<surname>Thiel</surname>
<given-names>N</given-names>
</name>
</person-group>
<article-title>Mechanical properties of polymer-infiltrated-ceramic-network materials</article-title>
<source>
<italic>Dental Materials</italic>
</source>
<year>2013</year>
<volume>29</volume>
<issue>4</issue>
<fpage>419</fpage>
<lpage>426</lpage>
<pub-id pub-id-type="pmid">23410552</pub-id>
</element-citation>
</ref>
<ref id="B71">
<label>71</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mormann</surname>
<given-names>WH</given-names>
</name>
<name>
<surname>Stawarczyk</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Ender</surname>
<given-names>A</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness</article-title>
<source>
<italic>Journal of the Mechanical Behavior of Biomedical Materials</italic>
</source>
<year>2013</year>
<volume>20</volume>
<fpage>113</fpage>
<lpage>125</lpage>
<pub-id pub-id-type="pmid">23455168</pub-id>
</element-citation>
</ref>
<ref id="B72">
<label>72</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Telleman</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Raghoebar</surname>
<given-names>GM</given-names>
</name>
<name>
<surname>Vissink</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Meijer</surname>
<given-names>HJA</given-names>
</name>
</person-group>
<article-title>The use of a coded healing abutment as an impression coping to design and mill an individualized anatomic abutment: a clinical report</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2011</year>
<volume>105</volume>
<issue>5</issue>
<fpage>282</fpage>
<lpage>285</lpage>
<pub-id pub-id-type="other">2-s2.0-79955609704</pub-id>
<pub-id pub-id-type="pmid">21530751</pub-id>
</element-citation>
</ref>
<ref id="B73">
<label>73</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Grossmann</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Pasciuta</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Finger</surname>
<given-names>IM</given-names>
</name>
</person-group>
<article-title>A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration</article-title>
<source>
<italic>Journal of Prosthetic Dentistry</italic>
</source>
<year>2006</year>
<volume>95</volume>
<issue>3</issue>
<fpage>258</fpage>
<lpage>261</lpage>
<pub-id pub-id-type="other">2-s2.0-33644881396</pub-id>
<pub-id pub-id-type="pmid">16543025</pub-id>
</element-citation>
</ref>
<ref id="B74">
<label>74</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ramsey</surname>
<given-names>CD</given-names>
</name>
<name>
<surname>Ritter</surname>
<given-names>RG</given-names>
</name>
</person-group>
<article-title>Utilization of digital technologies for fabrication of definitive implant-supported restorations</article-title>
<source>
<italic>Journal of Esthetic and Restorative Dentistry</italic>
</source>
<year>2012</year>
<volume>24</volume>
<issue>4</issue>
<fpage>299</fpage>
<lpage>308</lpage>
<pub-id pub-id-type="pmid">23025311</pub-id>
</element-citation>
</ref>
<ref id="B75">
<label>75</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Eliasson</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Örtorp</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>The accuracy of an implant impression technique using digitally coded healing abutments</article-title>
<source>
<italic>Clinical Implant Dentistry and Related Research</italic>
</source>
<year>2012</year>
<volume>14</volume>
<issue>supplement s1</issue>
<fpage>e30</fpage>
<lpage>e38</lpage>
<pub-id pub-id-type="other">2-s2.0-79953263064</pub-id>
<pub-id pub-id-type="pmid">21453396</pub-id>
</element-citation>
</ref>
<ref id="B76">
<label>76</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Michalakis</surname>
<given-names>KX</given-names>
</name>
<name>
<surname>Hirayama</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Garefis</surname>
<given-names>PD</given-names>
</name>
</person-group>
<article-title>Cement-retained versus screw-retained implant restorations: a critical review</article-title>
<source>
<italic>International Journal of Oral and Maxillofacial Implants</italic>
</source>
<year>2003</year>
<volume>18</volume>
<issue>5</issue>
<fpage>719</fpage>
<lpage>728</lpage>
<pub-id pub-id-type="other">2-s2.0-0142024931</pub-id>
<pub-id pub-id-type="pmid">14579961</pub-id>
</element-citation>
</ref>
<ref id="B77">
<label>77</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rauscher</surname>
<given-names>O</given-names>
</name>
</person-group>
<article-title>Impression-free implant restorations with cerec inlab</article-title>
<source>
<italic>International Journal of Computerized Dentistry</italic>
</source>
<year>2011</year>
<volume>14</volume>
<issue>2</issue>
<fpage>139</fpage>
<lpage>146</lpage>
<pub-id pub-id-type="other">2-s2.0-79960159331</pub-id>
<pub-id pub-id-type="pmid">21877380</pub-id>
</element-citation>
</ref>
<ref id="B78">
<label>78</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Brown</surname>
<given-names>SDK</given-names>
</name>
<name>
<surname>Payne</surname>
<given-names>AGT</given-names>
</name>
</person-group>
<article-title>Immediately restored single implants in the aesthetic zone of the maxilla using a novel design: 1-year report</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2011</year>
<volume>22</volume>
<issue>4</issue>
<fpage>445</fpage>
<lpage>454</lpage>
<pub-id pub-id-type="other">2-s2.0-79952508381</pub-id>
<pub-id pub-id-type="pmid">21561486</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
<floats-group>
<fig id="fig1" orientation="portrait" position="float">
<label>Figure 1</label>
<caption>
<p>Scanned image of a prepared tooth. The accuracy of the scanning is dependent on the overall smoothness and definition of the preparation.</p>
</caption>
<graphic xlink:href="IJD2013-768121.001"></graphic>
</fig>
<fig id="fig2" orientation="portrait" position="float">
<label>Figure 2</label>
<caption>
<p> (a) Initial image after scanning implant replica. The accuracy of the final image is influenced by smoothness of the sharp corners. (b) Reverse engineering of implant replica can reproduce exact implant dimensions.</p>
</caption>
<graphic xlink:href="IJD2013-768121.002"></graphic>
</fig>
<fig id="fig3" orientation="portrait" position="float">
<label>Figure 3</label>
<caption>
<p> (a) Engaging fitting surface of zirconia CAD/CAM abutment. Non-engaging fitting surfaces of titanium (b) and zirconia (c) frameworks. Accurate nonengaging surfaces can be milled since all their features are larger than the smallest milling bur.</p>
</caption>
<graphic xlink:href="IJD2013-768121.003"></graphic>
</fig>
</floats-group>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002D62 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 002D62 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3652193
   |texte=   Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:23690778" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022