How Precise Is Dental Volumetric Tomography in the Prediction of Bone Density?

Identifieur interne : 002D42 ( Pmc/Corpus ); précédent : 002D41; suivant : 002D43

How Precise Is Dental Volumetric Tomography in the Prediction of Bone Density?

Auteurs : Hakan Bilhan ; Selda Arat ; Onur Geckili

Source :

RBID : PMC:3369485

Abstract

Objectives. The aim of this study was to review the bone density assessment techniques and evaluate the macroscopic structure of bone specimens scored by Hounsfield Units (HUs) and decide if they are always in congruence. Methods. The mandible of a formalin-fixed human cadaver was scanned by dental volumetric tomography (DVT) for planning of the specimen positions and fabrication of a surgical guide and a surgical stent was fabricated afterwards. Bone cylinders of 3.5 mm diameter and 5 mm length, were excised from the mandible using the surgical stent with a slow speed trephine drill. After removal of the cylinders two more scans were performed and the images of the first scan were used for the determination of the HU values. The removed bone cylinder was inspected macroscopically as well by micro-CT scan. Results. The highest HU values were recorded in the interforaminal region, especially in the midline (408–742). Posterior regions showed lower HU values, especially the first molar regions (22–61 for the right; 14–66 for the left first molar regions). Conclusion. Within the limitations of this pilot study, it can be concluded that HU values alone could be a misleading diagnostic tool for the determination of bone density.


Url:
DOI: 10.1155/2012/348908
PubMed: 22693507
PubMed Central: 3369485

Links to Exploration step

PMC:3369485

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">How Precise Is Dental Volumetric Tomography in the Prediction of Bone Density?</title>
<author>
<name sortKey="Bilhan, Hakan" sort="Bilhan, Hakan" uniqKey="Bilhan H" first="Hakan" last="Bilhan">Hakan Bilhan</name>
<affiliation>
<nlm:aff id="I1">Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34093 Çapa Istanbul, Turkey</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Arat, Selda" sort="Arat, Selda" uniqKey="Arat S" first="Selda" last="Arat">Selda Arat</name>
<affiliation>
<nlm:aff id="I1">Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34093 Çapa Istanbul, Turkey</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Geckili, Onur" sort="Geckili, Onur" uniqKey="Geckili O" first="Onur" last="Geckili">Onur Geckili</name>
<affiliation>
<nlm:aff id="I1">Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34093 Çapa Istanbul, Turkey</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">22693507</idno>
<idno type="pmc">3369485</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3369485</idno>
<idno type="RBID">PMC:3369485</idno>
<idno type="doi">10.1155/2012/348908</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">002D42</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002D42</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">How Precise Is Dental Volumetric Tomography in the Prediction of Bone Density?</title>
<author>
<name sortKey="Bilhan, Hakan" sort="Bilhan, Hakan" uniqKey="Bilhan H" first="Hakan" last="Bilhan">Hakan Bilhan</name>
<affiliation>
<nlm:aff id="I1">Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34093 Çapa Istanbul, Turkey</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Arat, Selda" sort="Arat, Selda" uniqKey="Arat S" first="Selda" last="Arat">Selda Arat</name>
<affiliation>
<nlm:aff id="I1">Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34093 Çapa Istanbul, Turkey</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Geckili, Onur" sort="Geckili, Onur" uniqKey="Geckili O" first="Onur" last="Geckili">Onur Geckili</name>
<affiliation>
<nlm:aff id="I1">Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34093 Çapa Istanbul, Turkey</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International Journal of Dentistry</title>
<idno type="ISSN">1687-8728</idno>
<idno type="eISSN">1687-8736</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>
<italic>Objectives</italic>
. The aim of this study was to review the bone density assessment techniques and evaluate the macroscopic structure of bone specimens scored by Hounsfield Units (HUs) and decide if they are always in congruence.
<italic>Methods</italic>
. The mandible of a formalin-fixed human cadaver was scanned by dental volumetric tomography (DVT) for planning of the specimen positions and fabrication of a surgical guide and a surgical stent was fabricated afterwards. Bone cylinders of 3.5 mm diameter and 5 mm length, were excised from the mandible using the surgical stent with a slow speed trephine drill. After removal of the cylinders two more scans were performed and the images of the first scan were used for the determination of the HU values. The removed bone cylinder was inspected macroscopically as well by micro-CT scan.
<italic>Results</italic>
. The highest HU values were recorded in the interforaminal region, especially in the midline (408–742). Posterior regions showed lower HU values, especially the first molar regions (22–61 for the right; 14–66 for the left first molar regions).
<italic>Conclusion</italic>
. Within the limitations of this pilot study, it can be concluded that HU values alone could be a misleading diagnostic tool for the determination of bone density.</p>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Roos, J" uniqKey="Roos J">J Roos</name>
</author>
<author>
<name sortKey="Sennerby, L" uniqKey="Sennerby L">L Sennerby</name>
</author>
<author>
<name sortKey="Lekholm, U" uniqKey="Lekholm U">U Lekholm</name>
</author>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
<author>
<name sortKey="Grondahl, K" uniqKey="Grondahl K">K Gröndahl</name>
</author>
<author>
<name sortKey="Albrektsson, T" uniqKey="Albrektsson T">T Albrektsson</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Naert, I" uniqKey="Naert I">I Naert</name>
</author>
<author>
<name sortKey="Koutsikakis, G" uniqKey="Koutsikakis G">G Koutsikakis</name>
</author>
<author>
<name sortKey="Quirynen, M" uniqKey="Quirynen M">M Quirynen</name>
</author>
<author>
<name sortKey="Duyck, J" uniqKey="Duyck J">J Duyck</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" uniqKey="Van Steenberghe D">D van Steenberghe</name>
</author>
<author>
<name sortKey="Jacobs, R" uniqKey="Jacobs R">R Jacobs</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Fanuscu, Mi" uniqKey="Fanuscu M">MI Fanuscu</name>
</author>
<author>
<name sortKey="Chang, Tl" uniqKey="Chang T">TL Chang</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
<author>
<name sortKey="Lekholm, U" uniqKey="Lekholm U">U Lekholm</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lekholm, U" uniqKey="Lekholm U">U Lekholm</name>
</author>
<author>
<name sortKey="Zarb, Ga" uniqKey="Zarb G">GA Zarb</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Misch, Ce" uniqKey="Misch C">CE Misch</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Dougherty, G" uniqKey="Dougherty G">G Dougherty</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Apostol, L" uniqKey="Apostol L">L Apostol</name>
</author>
<author>
<name sortKey="Boudousq, V" uniqKey="Boudousq V">V Boudousq</name>
</author>
<author>
<name sortKey="Basset, O" uniqKey="Basset O">O Basset</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Stoppie, N" uniqKey="Stoppie N">N Stoppie</name>
</author>
<author>
<name sortKey="Pattijn, V" uniqKey="Pattijn V">V Pattijn</name>
</author>
<author>
<name sortKey="Van Cleynenbreugel, T" uniqKey="Van Cleynenbreugel T">T van Cleynenbreugel</name>
</author>
<author>
<name sortKey="Wevers, M" uniqKey="Wevers M">M Wevers</name>
</author>
<author>
<name sortKey="Sloten, Jv" uniqKey="Sloten J">JV Sloten</name>
</author>
<author>
<name sortKey="Ignace, N" uniqKey="Ignace N">N Ignace</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Guerrero, Me" uniqKey="Guerrero M">ME Guerrero</name>
</author>
<author>
<name sortKey="Jacobs, R" uniqKey="Jacobs R">R Jacobs</name>
</author>
<author>
<name sortKey="Loubele, M" uniqKey="Loubele M">M Loubele</name>
</author>
<author>
<name sortKey="Schutyser, F" uniqKey="Schutyser F">F Schutyser</name>
</author>
<author>
<name sortKey="Suetens, P" uniqKey="Suetens P">P Suetens</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" uniqKey="Van Steenberghe D">D van Steenberghe</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Loubele, M" uniqKey="Loubele M">M Loubele</name>
</author>
<author>
<name sortKey="Maes, F" uniqKey="Maes F">F Maes</name>
</author>
<author>
<name sortKey="Schutyser, F" uniqKey="Schutyser F">F Schutyser</name>
</author>
<author>
<name sortKey="Marchal, G" uniqKey="Marchal G">G Marchal</name>
</author>
<author>
<name sortKey="Jacobs, R" uniqKey="Jacobs R">R Jacobs</name>
</author>
<author>
<name sortKey="Suetens, P" uniqKey="Suetens P">P Suetens</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Scarfe, Wc" uniqKey="Scarfe W">WC Scarfe</name>
</author>
<author>
<name sortKey="Farman, Ag" uniqKey="Farman A">AG Farman</name>
</author>
<author>
<name sortKey="Sukovic, P" uniqKey="Sukovic P">P Sukovic</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Yamashina, A" uniqKey="Yamashina A">A Yamashina</name>
</author>
<author>
<name sortKey="Tanimoto, K" uniqKey="Tanimoto K">K Tanimoto</name>
</author>
<author>
<name sortKey="Sutthiprapaporn, P" uniqKey="Sutthiprapaporn P">P Sutthiprapaporn</name>
</author>
<author>
<name sortKey="Hayakawa, Y" uniqKey="Hayakawa Y">Y Hayakawa</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gonzalez Garcia, R" uniqKey="Gonzalez Garcia R">R González-García</name>
</author>
<author>
<name sortKey="Monje, F" uniqKey="Monje F">F Monje</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Keaveny, Tm" uniqKey="Keaveny T">TM Keaveny</name>
</author>
<author>
<name sortKey="Yeh, Oc" uniqKey="Yeh O">OC Yeh</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Van Lenthe, Gh" uniqKey="Van Lenthe G">GH van Lenthe</name>
</author>
<author>
<name sortKey="Van Den Bergh, Jpw" uniqKey="Van Den Bergh J">JPW van den Bergh</name>
</author>
<author>
<name sortKey="Hermus, Armm" uniqKey="Hermus A">ARMM Hermus</name>
</author>
<author>
<name sortKey="Huiskes, R" uniqKey="Huiskes R">R Huiskes</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kanis, Ja" uniqKey="Kanis J">JA Kanis</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Majumdar, S" uniqKey="Majumdar S">S Majumdar</name>
</author>
<author>
<name sortKey="Genant, Hk" uniqKey="Genant H">HK Genant</name>
</author>
<author>
<name sortKey="Grampp, S" uniqKey="Grampp S">S Grampp</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Genant, Hk" uniqKey="Genant H">HK Genant</name>
</author>
<author>
<name sortKey="Gordon, C" uniqKey="Gordon C">C Gordon</name>
</author>
<author>
<name sortKey="Jiang, Y" uniqKey="Jiang Y">Y Jiang</name>
</author>
<author>
<name sortKey="Lang, Tf" uniqKey="Lang T">TF Lang</name>
</author>
<author>
<name sortKey="Link, Tm" uniqKey="Link T">TM Link</name>
</author>
<author>
<name sortKey="Majumdar, S" uniqKey="Majumdar S">S Majumdar</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ruegsegger, P" uniqKey="Ruegsegger P">P Rüegsegger</name>
</author>
<author>
<name sortKey="Koller, B" uniqKey="Koller B">B Koller</name>
</author>
<author>
<name sortKey="Muller, R" uniqKey="Muller R">R Müller</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Parfitt, Am" uniqKey="Parfitt A">AM Parfitt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ulrich, D" uniqKey="Ulrich D">D Ulrich</name>
</author>
<author>
<name sortKey="Van Rietbergen, B" uniqKey="Van Rietbergen B">B van Rietbergen</name>
</author>
<author>
<name sortKey="Laib, A" uniqKey="Laib A">A Laib</name>
</author>
<author>
<name sortKey="Ruegsegger, P" uniqKey="Ruegsegger P">P Rüegsegger</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Teo, Jc" uniqKey="Teo J">JC Teo</name>
</author>
<author>
<name sortKey="Si Hoe, Km" uniqKey="Si Hoe K">KM Si-Hoe</name>
</author>
<author>
<name sortKey="Keh, Je" uniqKey="Keh J">JE Keh</name>
</author>
<author>
<name sortKey="Teoh, Sh" uniqKey="Teoh S">SH Teoh</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Feldkamp, La" uniqKey="Feldkamp L">LA Feldkamp</name>
</author>
<author>
<name sortKey="Goldstein, Sa" uniqKey="Goldstein S">SA Goldstein</name>
</author>
<author>
<name sortKey="Parfitt, Am" uniqKey="Parfitt A">AM Parfitt</name>
</author>
<author>
<name sortKey="Jesion, G" uniqKey="Jesion G">G Jesion</name>
</author>
<author>
<name sortKey="Kleerekoper, M" uniqKey="Kleerekoper M">M Kleerekoper</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kuhn, Jl" uniqKey="Kuhn J">JL Kuhn</name>
</author>
<author>
<name sortKey="Goldstein, Sa" uniqKey="Goldstein S">SA Goldstein</name>
</author>
<author>
<name sortKey="Feldkamp, La" uniqKey="Feldkamp L">LA Feldkamp</name>
</author>
<author>
<name sortKey="Goulet, Rw" uniqKey="Goulet R">RW Goulet</name>
</author>
<author>
<name sortKey="Jesion, G" uniqKey="Jesion G">G Jesion</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Swain, Mv" uniqKey="Swain M">MV Swain</name>
</author>
<author>
<name sortKey="Xue, J" uniqKey="Xue J">J Xue</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Paulus, Mj" uniqKey="Paulus M">MJ Paulus</name>
</author>
<author>
<name sortKey="Gleason, Ss" uniqKey="Gleason S">SS Gleason</name>
</author>
<author>
<name sortKey="Kennel, Sj" uniqKey="Kennel S">SJ Kennel</name>
</author>
<author>
<name sortKey="Hunsicker, Pr" uniqKey="Hunsicker P">PR Hunsicker</name>
</author>
<author>
<name sortKey="Johnson, Dk" uniqKey="Johnson D">DK Johnson</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bentley, Md" uniqKey="Bentley M">MD Bentley</name>
</author>
<author>
<name sortKey="Ortiz, Mc" uniqKey="Ortiz M">MC Ortiz</name>
</author>
<author>
<name sortKey="Ritman, El" uniqKey="Ritman E">EL Ritman</name>
</author>
<author>
<name sortKey="Carlos Romero, J" uniqKey="Carlos Romero J">J Carlos Romero</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Holdsworth, Dw" uniqKey="Holdsworth D">DW Holdsworth</name>
</author>
<author>
<name sortKey="Thornton, Mm" uniqKey="Thornton M">MM Thornton</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Guldberg, Re" uniqKey="Guldberg R">RE Guldberg</name>
</author>
<author>
<name sortKey="Lin, Asp" uniqKey="Lin A">ASP Lin</name>
</author>
<author>
<name sortKey="Coleman, R" uniqKey="Coleman R">R Coleman</name>
</author>
<author>
<name sortKey="Robertson, G" uniqKey="Robertson G">G Robertson</name>
</author>
<author>
<name sortKey="Duvall, C" uniqKey="Duvall C">C Duvall</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Geckili, O" uniqKey="Geckili O">O Geckili</name>
</author>
<author>
<name sortKey="Bilhan, H" uniqKey="Bilhan H">H Bilhan</name>
</author>
<author>
<name sortKey="Bilgin, T" uniqKey="Bilgin T">T Bilgin</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Meredith, N" uniqKey="Meredith N">N Meredith</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Park, Ys" uniqKey="Park Y">YS Park</name>
</author>
<author>
<name sortKey="Yi, Ky" uniqKey="Yi K">KY Yi</name>
</author>
<author>
<name sortKey="Lee, Is" uniqKey="Lee I">IS Lee</name>
</author>
<author>
<name sortKey="Jung, Yc" uniqKey="Jung Y">YC Jung</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Harrigan, Tp" uniqKey="Harrigan T">TP Harrigan</name>
</author>
<author>
<name sortKey="Jasty, M" uniqKey="Jasty M">M Jasty</name>
</author>
<author>
<name sortKey="Mann, Rw" uniqKey="Mann R">RW Mann</name>
</author>
<author>
<name sortKey="Harris, Wh" uniqKey="Harris W">WH Harris</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rho, Jy" uniqKey="Rho J">JY Rho</name>
</author>
<author>
<name sortKey="Zerwekh, Je" uniqKey="Zerwekh J">JE Zerwekh</name>
</author>
<author>
<name sortKey="Ashman, Rb" uniqKey="Ashman R">RB Ashman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Turkyilmaz, I" uniqKey="Turkyilmaz I">I Turkyilmaz</name>
</author>
<author>
<name sortKey="Sennerby, L" uniqKey="Sennerby L">L Sennerby</name>
</author>
<author>
<name sortKey="Yilmaz, B" uniqKey="Yilmaz B">B Yilmaz</name>
</author>
<author>
<name sortKey="Bilecenoglu, B" uniqKey="Bilecenoglu B">B Bilecenoglu</name>
</author>
<author>
<name sortKey="Ozbek, En" uniqKey="Ozbek E">EN Ozbek</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Seong, Wj" uniqKey="Seong W">WJ Seong</name>
</author>
<author>
<name sortKey="Kim, Uk" uniqKey="Kim U">UK Kim</name>
</author>
<author>
<name sortKey="Swift, Jq" uniqKey="Swift J">JQ Swift</name>
</author>
<author>
<name sortKey="Heo, Yc" uniqKey="Heo Y">YC Heo</name>
</author>
<author>
<name sortKey="Hodges, Js" uniqKey="Hodges J">JS Hodges</name>
</author>
<author>
<name sortKey="Ko, Cc" uniqKey="Ko C">CC Ko</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Boskey, Al" uniqKey="Boskey A">AL Boskey</name>
</author>
<author>
<name sortKey="Cohen, Ml" uniqKey="Cohen M">ML Cohen</name>
</author>
<author>
<name sortKey="Bullough, Pg" uniqKey="Bullough P">PG Bullough</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Nimni, Me" uniqKey="Nimni M">ME Nimni</name>
</author>
<author>
<name sortKey="Cheung, D" uniqKey="Cheung D">D Cheung</name>
</author>
<author>
<name sortKey="Strates, B" uniqKey="Strates B">B Strates</name>
</author>
<author>
<name sortKey="Kodama, M" uniqKey="Kodama M">M Kodama</name>
</author>
<author>
<name sortKey="Sheikh, K" uniqKey="Sheikh K">K Sheikh</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Nuccion, Sl" uniqKey="Nuccion S">SL Nuccion</name>
</author>
<author>
<name sortKey="Otsuka, Ny" uniqKey="Otsuka N">NY Otsuka</name>
</author>
<author>
<name sortKey="Davey, Jr" uniqKey="Davey J">JR Davey</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Wingerter, S" uniqKey="Wingerter S">S Wingerter</name>
</author>
<author>
<name sortKey="Calvert, G" uniqKey="Calvert G">G Calvert</name>
</author>
<author>
<name sortKey="Tucci, M" uniqKey="Tucci M">M Tucci</name>
</author>
<author>
<name sortKey="Benghuzzi, H" uniqKey="Benghuzzi H">H Benghuzzi</name>
</author>
<author>
<name sortKey="Russell, G" uniqKey="Russell G">G Russell</name>
</author>
<author>
<name sortKey="Puckett, A" uniqKey="Puckett A">A Puckett</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Comert, A" uniqKey="Comert A">A Cömert</name>
</author>
<author>
<name sortKey="Kokat, Am" uniqKey="Kokat A">AM Kökat</name>
</author>
<author>
<name sortKey="Akkoca Lu, M" uniqKey="Akkoca Lu M">M Akkocaòlu</name>
</author>
<author>
<name sortKey="Tekdemir, I" uniqKey="Tekdemir I">I Tekdemir</name>
</author>
<author>
<name sortKey="Akca, K" uniqKey="Akca K">K Akça</name>
</author>
<author>
<name sortKey="Cehreli, Mc" uniqKey="Cehreli M">MC Çehreli</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sedlin, Ed" uniqKey="Sedlin E">ED Sedlin</name>
</author>
<author>
<name sortKey="Hirsch, C" uniqKey="Hirsch C">C Hirsch</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Currey, Jd" uniqKey="Currey J">JD Currey</name>
</author>
<author>
<name sortKey="Brear, K" uniqKey="Brear K">K Brear</name>
</author>
<author>
<name sortKey="Zioupos, P" uniqKey="Zioupos P">P Zioupos</name>
</author>
<author>
<name sortKey="Reilly, Gc" uniqKey="Reilly G">GC Reilly</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Nazarian, A" uniqKey="Nazarian A">A Nazarian</name>
</author>
<author>
<name sortKey="Hermannsson, Bj" uniqKey="Hermannsson B">BJ Hermannsson</name>
</author>
<author>
<name sortKey="Muller, J" uniqKey="Muller J">J Müller</name>
</author>
<author>
<name sortKey="Zurakowski, D" uniqKey="Zurakowski D">D Zurakowski</name>
</author>
<author>
<name sortKey="Snyder, Bd" uniqKey="Snyder B">BD Snyder</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Chacon, Ge" uniqKey="Chacon G">GE Chacon</name>
</author>
<author>
<name sortKey="Dillard, F" uniqKey="Dillard F">F Dillard</name>
</author>
<author>
<name sortKey="Clelland, N" uniqKey="Clelland N">N Clelland</name>
</author>
<author>
<name sortKey="Rashid, R" uniqKey="Rashid R">R Rashid</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Muller, R" uniqKey="Muller R">R Müller</name>
</author>
<author>
<name sortKey="Ruegsegger, P" uniqKey="Ruegsegger P">P Rüegsegger</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Cendre, E" uniqKey="Cendre E">E Cendre</name>
</author>
<author>
<name sortKey="Mitton, D" uniqKey="Mitton D">D Mitton</name>
</author>
<author>
<name sortKey="Roux, Jp" uniqKey="Roux J">JP Roux</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Friberg, B" uniqKey="Friberg B">B Friberg</name>
</author>
<author>
<name sortKey="Sennerby, L" uniqKey="Sennerby L">L Sennerby</name>
</author>
<author>
<name sortKey="Roos, J" uniqKey="Roos J">J Roos</name>
</author>
<author>
<name sortKey="Johansson, P" uniqKey="Johansson P">P Johansson</name>
</author>
<author>
<name sortKey="Strid, Cg" uniqKey="Strid C">CG Strid</name>
</author>
<author>
<name sortKey="Lekholm, U" uniqKey="Lekholm U">U Lekholm</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Trisi, P" uniqKey="Trisi P">P Trisi</name>
</author>
<author>
<name sortKey="Rao, W" uniqKey="Rao W">W Rao</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Norton, Mr" uniqKey="Norton M">MR Norton</name>
</author>
<author>
<name sortKey="Gamble, C" uniqKey="Gamble C">C Gamble</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Riggs, Bl" uniqKey="Riggs B">BL Riggs</name>
</author>
<author>
<name sortKey="Hodgson, Sf" uniqKey="Hodgson S">SF Hodgson</name>
</author>
<author>
<name sortKey="O Allon, Mw" uniqKey="O Allon M">MW O’Fallon</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Endo, M" uniqKey="Endo M">M Endo</name>
</author>
<author>
<name sortKey="Tsunoo, T" uniqKey="Tsunoo T">T Tsunoo</name>
</author>
<author>
<name sortKey="Nakamori, N" uniqKey="Nakamori N">N Nakamori</name>
</author>
<author>
<name sortKey="Yoshida, K" uniqKey="Yoshida K">K Yoshida</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Yoo, S" uniqKey="Yoo S">S Yoo</name>
</author>
<author>
<name sortKey="Yin, Ff" uniqKey="Yin F">FF Yin</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sukovic, P" uniqKey="Sukovic P">P Sukovic</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Becker, W" uniqKey="Becker W">W Becker</name>
</author>
<author>
<name sortKey="Backer, Be" uniqKey="Backer B">BE Backer</name>
</author>
<author>
<name sortKey="Alsuwyed, A" uniqKey="Alsuwyed A">A Alsuwyed</name>
</author>
<author>
<name sortKey="Al Mubarak, S" uniqKey="Al Mubarak S">S Al-Mubarak</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Arisan, V" uniqKey="Arisan V">V Arisan</name>
</author>
<author>
<name sortKey="Bolukba I, N" uniqKey="Bolukba I N">N Bölükbaşi</name>
</author>
<author>
<name sortKey="Ersanli, S" uniqKey="Ersanli S">S Ersanli</name>
</author>
<author>
<name sortKey="Ozdemir, T" uniqKey="Ozdemir T">T Ozdemir</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Int J Dent</journal-id>
<journal-id journal-id-type="iso-abbrev">Int J Dent</journal-id>
<journal-id journal-id-type="publisher-id">IJD</journal-id>
<journal-title-group>
<journal-title>International Journal of Dentistry</journal-title>
</journal-title-group>
<issn pub-type="ppub">1687-8728</issn>
<issn pub-type="epub">1687-8736</issn>
<publisher>
<publisher-name>Hindawi Publishing Corporation</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">22693507</article-id>
<article-id pub-id-type="pmc">3369485</article-id>
<article-id pub-id-type="doi">10.1155/2012/348908</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>How Precise Is Dental Volumetric Tomography in the Prediction of Bone Density?</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Bilhan</surname>
<given-names>Hakan</given-names>
</name>
<xref ref-type="aff" rid="I1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Arat</surname>
<given-names>Selda</given-names>
</name>
<xref ref-type="aff" rid="I1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Geckili</surname>
<given-names>Onur</given-names>
</name>
<xref ref-type="aff" rid="I1"></xref>
<xref ref-type="corresp" rid="cor1">*</xref>
</contrib>
</contrib-group>
<aff id="I1">Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34093 Çapa Istanbul, Turkey</aff>
<author-notes>
<corresp id="cor1">*Onur Geckili:
<email>geckili@istanbul.edu.tr</email>
</corresp>
<fn fn-type="other">
<p>Academic Editor: Ozgur Pektas</p>
</fn>
</author-notes>
<pub-date pub-type="ppub">
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>30</day>
<month>5</month>
<year>2012</year>
</pub-date>
<volume>2012</volume>
<elocation-id>348908</elocation-id>
<history>
<date date-type="received">
<day>16</day>
<month>2</month>
<year>2012</year>
</date>
<date date-type="accepted">
<day>9</day>
<month>4</month>
<year>2012</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright © 2012 Hakan Bilhan et al.</copyright-statement>
<copyright-year>2012</copyright-year>
<license xlink:href="https://creativecommons.org/licenses/by/3.0/">
<license-p>This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<p>
<italic>Objectives</italic>
. The aim of this study was to review the bone density assessment techniques and evaluate the macroscopic structure of bone specimens scored by Hounsfield Units (HUs) and decide if they are always in congruence.
<italic>Methods</italic>
. The mandible of a formalin-fixed human cadaver was scanned by dental volumetric tomography (DVT) for planning of the specimen positions and fabrication of a surgical guide and a surgical stent was fabricated afterwards. Bone cylinders of 3.5 mm diameter and 5 mm length, were excised from the mandible using the surgical stent with a slow speed trephine drill. After removal of the cylinders two more scans were performed and the images of the first scan were used for the determination of the HU values. The removed bone cylinder was inspected macroscopically as well by micro-CT scan.
<italic>Results</italic>
. The highest HU values were recorded in the interforaminal region, especially in the midline (408–742). Posterior regions showed lower HU values, especially the first molar regions (22–61 for the right; 14–66 for the left first molar regions).
<italic>Conclusion</italic>
. Within the limitations of this pilot study, it can be concluded that HU values alone could be a misleading diagnostic tool for the determination of bone density.</p>
</abstract>
</article-meta>
</front>
<body>
<sec id="sec1">
<title>1. Introduction</title>
<p>Dental implants play an important role in the treatment of partial or complete edentulism. Although the success is very high, posterior maxilla can withstand lower mechanical forces because of its thinner cortical layer, and the lower density of the maxillary spongiosa [
<xref rid="B1" ref-type="bibr">1</xref>
] thus is more critical than other sites. Furthermore, the maxillary sinus restrict the available bone volume, necessitating shorter implants and/or grafting procedures [
<xref rid="B2" ref-type="bibr">2</xref>
].</p>
<p>Bone density plays an important role in planning of implant dentistry in terms of timing of loading as well as number of implants to be used for denture support especially in critical locations such as posterior maxillae. Bone mass, structural properties (macro- and microarchitecture), and material properties (modulus of elasticity, mineral density, etc.) constitute mechanical competence of bone, which is commonly referred to as bone quality in implant dentistry [
<xref rid="B3" ref-type="bibr">3</xref>
]. Substantial variations in bone quality in corresponding anatomical sites and direct correlation between bone quality and implant success rates exist [
<xref rid="B4" ref-type="bibr">4</xref>
]. Since mechanical behavior of bone is a critical factor in the attainment and maintenance of osseointegration, several classification systems and procedures were advocated for assessing bone quality and predicting prognosis [
<xref rid="B5" ref-type="bibr">5</xref>
,
<xref rid="B6" ref-type="bibr">6</xref>
].</p>
<p>These assessment methods have various limitations in addressing cortical and cancellous bones in a subjective and quantitative manner. There are several radiological methods for bone mineral density (BMD) measurements yielding close relationships such as dual-X-ray absorptiometry (DXA) scanning [
<xref rid="B7" ref-type="bibr">7</xref>
] and Hounsfield unit (HUs) from computed tomography imaging [
<xref rid="B7" ref-type="bibr">7</xref>
]. Texture analysis has been applied in micro-CT [
<xref rid="B9" ref-type="bibr">8</xref>
], while Hounsfield units (HU) have been used in spiral CT as a measure, related to jaw BMD [
<xref rid="B10" ref-type="bibr">9</xref>
]. Cone beam computed tomography (CBCT) is a more recent development than spiral CT. Its clinical application in the field of dentomaxillofacial radiology is gaining importance and spreading widely [
<xref rid="B11" ref-type="bibr">10</xref>
<xref rid="B13" ref-type="bibr">12</xref>
], but the available research on CBCT-based bone quality assessment is scarce. Low dose CBCT is often advised for implant planning, considering the possibility to gather clinically relevant 3D data at a low dose, but CBCT does not necessarily allow reliable and accurate bone quality assessment when focusing on the inherent radiographic density information that is otherwise expressed by HU [
<xref rid="B14" ref-type="bibr">13</xref>
]. On the other hand, a very recent study reported of a strong positive correlation of radiographic bone density assessed by CBCT with bone volumetric fraction assessed by micro-CT at the site of dental implants in the maxillary bones [
<xref rid="B21" ref-type="bibr">14</xref>
].</p>
<p>Although strong correlations exist, still a 30–50% of unaccounted variance in mechanical properties from bone density measurement has been reported [
<xref rid="B15" ref-type="bibr">15</xref>
,
<xref rid="B16" ref-type="bibr">16</xref>
]. Osteoporotic cancellous bone is characterized by low bone mass as well as a deterioration of the microarchitecture. Whether a patient is diagnosed osteoporotic depends only on his/her BMD and how this BMD value compares to a population average [
<xref rid="B17" ref-type="bibr">17</xref>
]. Clinical results have shown that BMD of patients with osteoporotic bone fractures and patients without such fractures can have a substantial overlap [
<xref rid="B18" ref-type="bibr">18</xref>
], causing variance similar to that in density—mechanical property relationship studies. The microarchitecture of cancellous bone has been largely attributed to this variance; density approximates the amount of bone tissue within a cancellous bone specimen but it does not quantify the microarchitecture that is inherent. Together with bone density readings, a quantitative measurement of microarchitectural parameters may improve our ability to better estimate bone strength [
<xref rid="B19" ref-type="bibr">19</xref>
]. Microcomputed tomography (micro-CT) is a relatively new method to image and quantify bone with very high resolution [
<xref rid="B21" ref-type="bibr">14</xref>
,
<xref rid="B20" ref-type="bibr">20</xref>
]. Microcomputed tomography (micro-CT) scanners, with similar working principle as conventional clinical CT scanners, have been used to study microstructure of materials in three dimensions and to study the relationship between microarchitectural parameters [
<xref rid="B22" ref-type="bibr">21</xref>
] and mechanical properties of cancellous bone [
<xref rid="B23" ref-type="bibr">22</xref>
]. Micro-CT may not be applicable routinely in clinical practice for now, although as a reliable method for bone mass and structure evaluation, it might offer much needed insight into bone quality assessment by providing objective and quantitative microstructural data. Image datasets of human cancellous bone specimens at micron resolution were acquired and from these datasets, microarchitectural parameters have been determined and converted into microfinite element (FE) models [
<xref rid="B24" ref-type="bibr">23</xref>
]. It was shown that the predictive power of bone strength and stiffness was improved with the combination of bone density and microarchitecture information and this work supported the prediction of microarchitecture using current clinical computed tomography imaging technology [
<xref rid="B24" ref-type="bibr">23</xref>
].</p>
<p>While clinical CT scanners typically produce images composed of 1 mm
<sup>3</sup>
volume elements (voxels), X-ray microcomputed tomography (micro-CT or
<italic>μ</italic>
CT) systems developed in the early 1980s had much better spatial resolution, producing voxels in the range of 5–50 
<italic>μ</italic>
m, or approximately 1,000,000 times smaller in volume than CT voxels [
<xref rid="B25" ref-type="bibr">24</xref>
,
<xref rid="B26" ref-type="bibr">25</xref>
]. Early micro-CT scanners were custom-built and not widely available. Compact commercial systems are now available and are rapidly becoming essential components of many academic and industrial research laboratories. A wide range of specimens may be examined directly using Micro-CT including mineralized tissues such as teeth, bone, and materials such as ceramics, polymers, or biomaterial scaffolds [
<xref rid="B27" ref-type="bibr">26</xref>
].</p>
<p>Micro-CT systems are now widely used in many academic fields, several recent reviews have presented the current state of micro-CT imaging and analysis of them [
<xref rid="B21" ref-type="bibr">14</xref>
,
<xref rid="B28" ref-type="bibr">27</xref>
<xref rid="B31" ref-type="bibr">30</xref>
].</p>
<p>Emphasis has traditionally been placed on the cortical bone as quality predictor due to its stiffness for achieving primary stabilization [
<xref rid="B32" ref-type="bibr">31</xref>
,
<xref rid="B33" ref-type="bibr">32</xref>
]. However, a dental implant is mainly in contact with cancellous part of bone, and mechanical characteristics of cancellous bone also influence the load bearing capacity of implant-bone union. In fact, the presurgical determination of bone density plays an important role in planning of the surgical procedure as well as prosthetic treatment. In another study human cadaveric maxillary and mandibular trabecular bone with 3D morphometric data acquired through micro-CT were analyzed and correlated with bone density measurements in Hounsfield scale and Lekholm-Zarb bone classification [
<xref rid="B3" ref-type="bibr">3</xref>
,
<xref rid="B5" ref-type="bibr">5</xref>
].</p>
<p>Micro-CT is a nondestructive, fast, and precise technique that allows measurements of trabecular and cortical bone [
<xref rid="B27" ref-type="bibr">26</xref>
]. It can provide a spatial representation of bone formation at the implant surface and the peri-implant region up to a few microns or even better, and can evaluate both qualitative and quantitative morphometry of bone integration about dental implants [
<xref rid="B34" ref-type="bibr">33</xref>
].</p>
<p>The aim of this pilot study was to review the current literature about bone density assessment and evaluate the macroscopic structure of bone specimens having been scored by Hounsfield units afore.</p>
</sec>
<sec id="sec2">
<title>2. Material and Methods</title>
<sec sec-type="subsection" id="sec2.1">
<title>2.1. Experimental Protocol</title>
<sec sec-type="subsubsection" id="sec2.1.1">
<title>2.1.1. Preoperative CBCT Imaging</title>
<p>The mandible of a formalin-fixed human cadaver was involved in this study. After removal of the mandible from the cadaver, the obtained mandible was scanned by dental volumetric tomography (DVT) for planning of the specimen positions and fabrication of a surgical guide. The scan of the mandible was performed with a Newtom (Newtom Cone Beam 3D Imaging, AFP Imaging Corporation, New York, USA;
<xref ref-type="fig" rid="fig1">Figure 1</xref>
). A surgical guide was fabricated on the cast obtained from an impression of the alveolar process of the mandible (
<xref ref-type="fig" rid="fig2">Figure 2</xref>
).</p>
</sec>
<sec sec-type="subsubsection" id="sec2.1.2">
<title>2.1.2. Specimen Preparation</title>
<p>Bone cylinders of 3.5 mm diameter and 5 mm length, were excised from a cadaver mandible using the surgical stent (
<xref ref-type="fig" rid="fig3">Figure 3</xref>
). Excising of bone cylinders from the mandibular body was done using a slow speed trephine drill (Trephine Drill 3.5 mm × 22 mm, Salvin Dental Specialties, Inc, Charlotte, NC, USA) under constant irrigation by the use of the prepared stent (
<xref ref-type="fig" rid="fig4">Figure 4</xref>
). Nine bone cylinders in total were extracted for the experiment; cylinders were stored in consequently numerated 0.9% saline solution containing little vessels. However, since 2 of the cylinders were damaged during removal, these were excluded from the study. The 5 mm cylinder length was chosen to satisfy continuum assumption, so that mechanical properties derived for each cylinder was representative of the whole bone [
<xref rid="B35" ref-type="bibr">34</xref>
].</p>
</sec>
<sec sec-type="subsubsection" id="sec2.1.3">
<title>2.1.3. Postoperative CBCT Imaging and Determination of the Hounsfield Units</title>
<p>After removal of the cylinders two more scans were performed, with the surgical stent and without surgical the stent, respectively. The images of the first scan were used for the determination of the Hounsfield Unit values. The cavities of the removed bone specimens were localized by viewing the second and third scan images and the Hounsfield Unit values of the missing bone cylinders was determined by taking the mean of five values: coronal, apical, buccal, lingual, and the center. The software (Newtom Imaging Software, AFP Imaging Corporation, New York, USA) is capable of giving graphically the HU values of the marked zone. For each bone cylinder, the raw CT values were converted into HU by means of the following formula [
<xref rid="B36" ref-type="bibr">35</xref>
]: HU = 1000(CT − CT
<sub>
<italic>w</italic>
</sub>
)/(CT
<sub>
<italic>w</italic>
</sub>
− CT
<sub>
<italic>a</italic>
</sub>
) where CT, CT
<sub>
<italic>w</italic>
</sub>
, and CT
<sub>
<italic>a</italic>
</sub>
are the values of bone, saline, and air, respectively.</p>
</sec>
<sec sec-type="subsubsection" id="sec2.1.4">
<title>2.1.4. Micro-CT Imaging</title>
<p>As a part of the pilot study, the bone cylinder on the left first premolar molar region of human cadaver bone was randomly chosen for micro-CT scanning. The bone cylinder was placed in a custom vessel wrapped in paper soaked with saline solution to prevent any desiccation, and isotropically scanned at 14 
<italic>μ</italic>
m resolution with a model 1172 micro-CT scanner (Skyscan, Kontich, Belgium) using a CBCT scanning technique (
<xref ref-type="fig" rid="fig5">Figure 5</xref>
). CBCT is a novel CT image acquisition technique in which up to a several hundred CT images (as opposed to 1–3 images in normal CT) are reconstructed by one data acquisition as the data on the fluoroscopic image is handled as plane data. The total time required for scanning and reconstruction was approximately 30 minutes per sample, thus deterioration of the bone cylinder as a result of being exposed to ambient conditions was significantly reduced. To ensure a consistent CT image resolution among all the datasets, the scanner turntable location was fixed at a specific SOD and SID distance of 19.03 mm and 356.90 mm, respectively. The X-ray parameters were set at 51 kV and 200 
<italic>μ</italic>
A and the CT images were processed at a scaling coefficient of 50 and averaged three times. With these parameters, together with a 0.5 mm aluminum plate placed at the X-ray detector, a good contrast was achieved in the resultant CT images between trabeculae. Resultant dataset had an isotropic resolution of 14.836 
<italic>μ</italic>
m. Resultant CT images for each bone cylinder was evaluated for microarchitectural parameters [
<xref rid="B19" ref-type="bibr">19</xref>
] such as tissue volume, bone volume, percent bone volume, tissue surface, bone surface, intersection surface, bone specific surface, bone surface density, trabecular bone pattern factor, structure model index, trabecular thickness, trabecular number and trabecular separation (CT Analyzer, Skyscan, Belgium) (
<xref ref-type="fig" rid="fig6">Figure 6</xref>
).</p>
</sec>
</sec>
</sec>
<sec id="sec3">
<title>3. Results</title>
<sec sec-type="subsection" id="sec3.1">
<title>3.1. Relationship between Microarchitectural Parameters and Hounsfield Unit and Interrelationship between Microarchitectural Parameters</title>
<p>The main objective of this study was to study the possibility of inferring of microarchitectural parameters from clinical CT images.</p>
<p>The rate of cancellous bone volume in the total volume of core is the bone volume density (BV/TV), which was in the range of 0.12–0.29 for the sample.</p>
<p>All the measured HU values, means, and ranges are shown in
<xref ref-type="table" rid="tab1">Table 1</xref>
. The highest HU values were encountered in the interforaminal region, especially in the midline (408–742). Posterior regions showed lower HU values, especially the first molar regions (22–61 for the right; 14–66 for the left first molar regions). The bone cylinder which was scanned by micro-CT showed an incongruous structure when HU of the donor site was considered. The HU values indicated a higher density bone, whereas the Micro CT image revealed rather a spongious bone (
<xref ref-type="fig" rid="fig6">Figure 6</xref>
).</p>
</sec>
</sec>
<sec id="sec4">
<title>4. Discussion </title>
<p>Our primary objective of studying the relationship between HU from CT images and microarchitectural parameters, density given in objective values (mg/cm
<sup>3</sup>
) and HU, was the evaluation of a diagnostic tool for in vivo assessment of bone quality. </p>
<p>A formalin-fixed cadaver mandible was harvested and used in the present study for several reasons. The main reason was the ease to obtain in comparison to a fresh cadaver as recommended in a few studies [
<xref rid="B37" ref-type="bibr">36</xref>
,
<xref rid="B38" ref-type="bibr">37</xref>
]. Another reason was the protection from communicable diseases. Tissue fixation with 10% formalin (4% formaldehyde) is widely used to preserve specimens without refrigeration, offering researchers the added benefit of protection from specimens with communicable diseases [
<xref rid="B39" ref-type="bibr">38</xref>
<xref rid="B43" ref-type="bibr">42</xref>
]. Although it is assumed that formalin fixation alters the mechanical properties of bone, studies failed to deduce quantitative data [
<xref rid="B44" ref-type="bibr">43</xref>
,
<xref rid="B45" ref-type="bibr">44</xref>
]. Chemical fixation through the use of aldehydes has been shown to cause a direct effect on bone mechanical properties by forming an increased number of inter- and intrafibrillar cross-links of primary amine groups of polypeptide collagen chains [
<xref rid="B39" ref-type="bibr">38</xref>
,
<xref rid="B45" ref-type="bibr">44</xref>
] have shown that while formalin fixation has no effect on the mineral composition of bone, it causes the collagen fibrils to be more closely packed. However, in a recent study it was reported that formalin fixation and freezing would not adversely affect the viscoelastic and elastic mechanical properties of murine bone [
<xref rid="B46" ref-type="bibr">45</xref>
]. The use of embalmed bone is known to be used in studies testing the mechanical behavior and efficacy of fracture fixation devices, joint prostheses, and other reconstructive orthopedic devices [
<xref rid="B47" ref-type="bibr">46</xref>
].</p>
<p>Accuracy of micro-CT was qualitatively evaluated by comparing to standard histomorphometric data with the corresponding CT slices for the same specimen. The results showed that, in general there was a good correlation between histomorphometric data and microtomographic data. One author obtained a correlation coefficient of 0.855 [
<xref rid="B34" ref-type="bibr">33</xref>
]. </p>
<p>The result from this pilot study has raised doubt that in addition to bone density, bone microarchitectural parameters can also be predicted from clinical-CT imaging. We chose to use the CBCT, as it is a three-dimensional measurement often used in dentistry. In similar studies [
<xref rid="B48" ref-type="bibr">47</xref>
,
<xref rid="B49" ref-type="bibr">48</xref>
], it was reported that to reasonably evaluate cancellous bone architecture, image datasets of resolutions not more than 100 
<italic>μ</italic>
m should be used. Microarchitectural parameters from both clinical-CT imaging and histological sections were also compared and it was shown that high-resolution clinical-CT resulted in an overestimation of microarchitectural parameters. In a recent study [
<xref rid="B3" ref-type="bibr">3</xref>
], the scan was initially utilized to assess bone quality subjectively in Lekholm and Zarb classification [
<xref rid="B5" ref-type="bibr">5</xref>
] at incisor and molar edentulous sites by rating the distribution of cortical and cancellous bones and density of cancellous bone in HU was determined through a function of the CT equipment by averaging the readings of multiple slices within respective sites. Similarly, in our study, the Hounsfield units were determined by taking the average of five values of the removed cylinders: coronal, apical, buccal, center, and lingual, additionally stating the range of HU values of each cylinder. </p>
<p>For harvesting the cylinders a trephine drill was used as described in another study [
<xref rid="B3" ref-type="bibr">3</xref>
]. There is great difficulty in accurately excising bone specimens that correspond to the exact CT volume of interest, if the bone specimens are to be excised after clinical imaging, as pointed out in a previous study [
<xref rid="B24" ref-type="bibr">23</xref>
]. In the previously mentioned study, the specimens were scanned after removal from the bone for this reason. However in the present study we preferred to use the whole mandible in the CBCT to mimic the clinical application. </p>
<p>In a study by Fanuscu and Chang [
<xref rid="B3" ref-type="bibr">3</xref>
], the anterior sites in both arches were noted to be volumetrically denser than the posterior sites, indicating varying bone mass. It was noted that volume density remained depthwise stable in the maxilla, whereas in the mandible it decreased with depth in the corono-apical direction, as being seen in our study too. </p>
<p>Current classifications and procedures for evaluating bone have certain shortcomings as mechanical competence in terms of mass, structure and material is not well addressed for trabecular bone. There have been unsuccessful attempts to quantify bone density in consideration of mechanical strength. Friberg et al. [
<xref rid="B50" ref-type="bibr">49</xref>
] proposed an objective cutting resistance procedure that might provide a composite value for mechanical characteristics in predicting bone quality for initial stability. However, mechanics of drilling with a bur and withstanding occlusal forces by an implant has to be further investigated and correlated. Trisi and Rao [
<xref rid="B51" ref-type="bibr">50</xref>
] compared histomorphometrics and hand-felt cutting resistance and demonstrated that subjective tactile sensation was proved to be poor in discerning finer differences. </p>
<p>About ten years ago an image-based bone density classification that utilizes gray-scale values through CT was suggested [
<xref rid="B52" ref-type="bibr">51</xref>
]. The method of preoperative bone density measurement was advocated as a prognostic indicator in which site-specific, objective and quantitative results on the Hounsfield scale would provide bone-quality information. Following this perspective, the reliability of Hounsfield units in predicting bone density was evaluated in this preliminary study. The proposed classification evaluates bone mass; however, its mechanical value is limited without structural and material properties. Riggs et al. [
<xref rid="B53" ref-type="bibr">52</xref>
] reported on bone mass increase in osteoporotic patients by medications and found that bone strength was not increased and fracture risk was not lowered as much as expected by the gain in bone density. This suggests that there is an important influence of the complex microarchitecture on the mechanical competence of bone. </p>
<p>It should be underlined that CBCT data have a larger amount of scattered X-rays than conventional spiral CT. This may enhance the noise in reconstructed images, and thus affect the low contrast detectability [
<xref rid="B54" ref-type="bibr">53</xref>
]. Because of scatter and artifacts, HU values in CBCT are not valid, and therefore the method of correlating BMD to HU values from CBCT is not ideal. Moreover, the scatter and artifacts in CBCT get worse around inhomogeneous tissues with reduced HU values up to 200 HU [
<xref rid="B55" ref-type="bibr">54</xref>
], which confirms that the HU in CBCT is not a valid method for bone quality assessment. Since up till now CBCT-based bone quality assessment is neither accurate nor reliable, there is a need to find methods to circumvent the shortcomings of this particular development, so as to have a reliable way to assess bone quality or there is a need for methods, other than density measurements, for bone quality assessment. In a bone density assessment study it was concluded that mandibular cortical bone was denser than cortical bone of the upper maxilla, whereas cancellous bone has similar densities in both mandible and the upper maxilla. The main problem appears to lie in the differentiation of tissues of similar density [
<xref rid="B21" ref-type="bibr">14</xref>
]. Texture analysis may thus come into play, which is strengthened by the fact that bone quality may be expressed by its microarchitectural composition. May be for this reason a very recent study concluded that correlation of micro-CT and conventional histomorphometry should be subject of future research [
<xref rid="B21" ref-type="bibr">14</xref>
]. In contrast to classic histomorphometry architectural metric parameters such as bone volume (BV), total volume (TV), and bone surface can be directly determined from the 3D images acquired by micro-CTs, without assuming the geometric model [
<xref rid="B58" ref-type="bibr">55</xref>
]. </p>
<p>The increased failure rate of implants that are placed in posterior regions was attributed to differences in bone quality and quantity and elevated occlusal stress in the molar areas [
<xref rid="B56" ref-type="bibr">56</xref>
,
<xref rid="B57" ref-type="bibr">57</xref>
]. Therefore it is very important to analyze the bone density in posterior maxillae before implant surgery. </p>
<p>Within the limitations of this pilot study, it can be concluded that HU values alone could be a misleading diagnostic tool for the determination of bone density. It is advisable to concentrate future research on density quantification from clinical CT images and relate those to various bone types with different mechanical properties to be able to make predictions concerning the bone quality. </p>
</sec>
</body>
<back>
<ack>
<title>Acknowledgments</title>
<p>The team would like to thank SKYSCAN for offering the micro-CT scanning possibility and technical support. They appreciate the kind efforts of Asim Horasan (Chief Engineer in Teknodent) in giving technical and logistic assistance for this study. The authors declare that there are no conflict of interests in this study. </p>
</ack>
<ref-list>
<ref id="B1">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roos</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Sennerby</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Lekholm</surname>
<given-names>U</given-names>
</name>
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Gröndahl</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Albrektsson</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant</article-title>
<source>
<italic>International Journal of Oral and Maxillofacial Implants</italic>
</source>
<year>1997</year>
<volume>12</volume>
<issue>4</issue>
<fpage>504</fpage>
<lpage>514</lpage>
<pub-id pub-id-type="pmid">9274079</pub-id>
</element-citation>
</ref>
<ref id="B2">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Naert</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Koutsikakis</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Quirynen</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Duyck</surname>
<given-names>J</given-names>
</name>
<name>
<surname>van Steenberghe</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Jacobs</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Biologic outcome of implant-supported restorations in the treatment of partial edentulism part 2: a longitudinal radiographic evaluation</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2002</year>
<volume>13</volume>
<issue>4</issue>
<fpage>390</fpage>
<lpage>395</lpage>
<pub-id pub-id-type="pmid">12175376</pub-id>
</element-citation>
</ref>
<ref id="B3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fanuscu</surname>
<given-names>MI</given-names>
</name>
<name>
<surname>Chang</surname>
<given-names>TL</given-names>
</name>
</person-group>
<article-title>Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2004</year>
<volume>15</volume>
<fpage>213</fpage>
<lpage>218</lpage>
<pub-id pub-id-type="pmid">15008933</pub-id>
</element-citation>
</ref>
<ref id="B4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Lekholm</surname>
<given-names>U</given-names>
</name>
</person-group>
<article-title>Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report</article-title>
<source>
<italic>International Journal of Oral and Maxillofacial Implants</italic>
</source>
<year>1993</year>
<volume>8</volume>
<issue>6</issue>
<fpage>635</fpage>
<lpage>640</lpage>
<pub-id pub-id-type="pmid">8181825</pub-id>
</element-citation>
</ref>
<ref id="B5">
<label>5</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Lekholm</surname>
<given-names>U</given-names>
</name>
<name>
<surname>Zarb</surname>
<given-names>GA</given-names>
</name>
</person-group>
<person-group person-group-type="editor">
<name>
<surname>Branemark</surname>
<given-names>PI</given-names>
</name>
<name>
<surname>Zarb</surname>
<given-names>GA</given-names>
</name>
<name>
<surname>Albrektsson</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>Patient selection and preparation</article-title>
<source>
<italic>Tissue Integrated Prostheses: Osseointegration in Clinical Dentistry</italic>
</source>
<year>1985</year>
<publisher-loc>Chicago, Ill, USA</publisher-loc>
<publisher-name>Quintessence Publishing</publisher-name>
<fpage>199</fpage>
<lpage>209</lpage>
</element-citation>
</ref>
<ref id="B6">
<label>6</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Misch</surname>
<given-names>CE</given-names>
</name>
</person-group>
<person-group person-group-type="editor">
<name>
<surname>Misch</surname>
<given-names>CE</given-names>
</name>
</person-group>
<article-title>Density of bone: effect on treatment planning, surgical approach, and healing</article-title>
<source>
<italic>Contemporary Implant Dentistry</italic>
</source>
<year>1993</year>
<publisher-loc>St. Louis, Mo, USA</publisher-loc>
<publisher-name>Mosby-Year Book</publisher-name>
<fpage>469</fpage>
<lpage>485</lpage>
</element-citation>
</ref>
<ref id="B7">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dougherty</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis</article-title>
<source>
<italic>Medical Engineering and Physics</italic>
</source>
<year>1996</year>
<volume>18</volume>
<issue>7</issue>
<fpage>557</fpage>
<lpage>568</lpage>
<pub-id pub-id-type="pmid">8892240</pub-id>
</element-citation>
</ref>
<ref id="B9">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Apostol</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Boudousq</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Basset</surname>
<given-names>O</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Relevance of 2D radiographic texture analysis for the assessment of 3D bone micro-architecture</article-title>
<source>
<italic>Medical Physics</italic>
</source>
<year>2006</year>
<volume>33</volume>
<issue>9</issue>
<fpage>3546</fpage>
<lpage>3556</lpage>
</element-citation>
</ref>
<ref id="B10">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stoppie</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Pattijn</surname>
<given-names>V</given-names>
</name>
<name>
<surname>van Cleynenbreugel</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Wevers</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Sloten</surname>
<given-names>JV</given-names>
</name>
<name>
<surname>Ignace</surname>
<given-names>N</given-names>
</name>
</person-group>
<article-title>Structural and radiological parameters for the characterization of jawbone</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2006</year>
<volume>17</volume>
<issue>2</issue>
<fpage>124</fpage>
<lpage>133</lpage>
</element-citation>
</ref>
<ref id="B11">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Guerrero</surname>
<given-names>ME</given-names>
</name>
<name>
<surname>Jacobs</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Loubele</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Schutyser</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Suetens</surname>
<given-names>P</given-names>
</name>
<name>
<surname>van Steenberghe</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>State-of-the-art on cone beam CT imaging for preoperative planning of implant placement</article-title>
<source>
<italic>Clinical Oral Investigations</italic>
</source>
<year>2006</year>
<volume>10</volume>
<issue>1</issue>
<fpage>1</fpage>
<lpage>7</lpage>
<pub-id pub-id-type="pmid">16482455</pub-id>
</element-citation>
</ref>
<ref id="B12">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Loubele</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Maes</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Schutyser</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Marchal</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Jacobs</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Suetens</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study</article-title>
<source>
<italic>Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology</italic>
</source>
<year>2006</year>
<volume>102</volume>
<issue>2</issue>
<fpage>225</fpage>
<lpage>234</lpage>
</element-citation>
</ref>
<ref id="B13">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Scarfe</surname>
<given-names>WC</given-names>
</name>
<name>
<surname>Farman</surname>
<given-names>AG</given-names>
</name>
<name>
<surname>Sukovic</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Clinical applications of cone-beam computed tomography in dental practice</article-title>
<source>
<italic>Journal of the Canadian Dental Association</italic>
</source>
<year>2006</year>
<volume>72</volume>
<issue>1</issue>
<fpage>75</fpage>
<lpage>80</lpage>
<pub-id pub-id-type="pmid">16480609</pub-id>
</element-citation>
</ref>
<ref id="B14">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yamashina</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Tanimoto</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Sutthiprapaporn</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Hayakawa</surname>
<given-names>Y</given-names>
</name>
</person-group>
<article-title>The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT</article-title>
<source>
<italic>Dentomaxillofacial Radiology</italic>
</source>
<year>2008</year>
<volume>37</volume>
<issue>5</issue>
<fpage>245</fpage>
<lpage>251</lpage>
<pub-id pub-id-type="pmid">18606745</pub-id>
</element-citation>
</ref>
<ref id="B21">
<label>14</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>González-García</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Monje</surname>
<given-names>F</given-names>
</name>
</person-group>
<article-title>The reliability of cone-beam computed tomography to assess bone density at dental implant recipientsites: a histomorphometric analysis by micro-CT</article-title>
<comment>
<italic>Clinical Oral Implants Research</italic>
. In press</comment>
</element-citation>
</ref>
<ref id="B15">
<label>15</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Keaveny</surname>
<given-names>TM</given-names>
</name>
<name>
<surname>Yeh</surname>
<given-names>OC</given-names>
</name>
</person-group>
<article-title>Architecture and trabecular bone—toward an improved understanding of the biomechanical effects of age, sex and osteoporosis</article-title>
<source>
<italic>Journal of Musculoskeletal Neuronal Interactions</italic>
</source>
<year>2002</year>
<volume>2</volume>
<issue>3</issue>
<fpage>205</fpage>
<lpage>208</lpage>
<pub-id pub-id-type="pmid">15758434</pub-id>
</element-citation>
</ref>
<ref id="B16">
<label>16</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>van Lenthe</surname>
<given-names>GH</given-names>
</name>
<name>
<surname>van den Bergh</surname>
<given-names>JPW</given-names>
</name>
<name>
<surname>Hermus</surname>
<given-names>ARMM</given-names>
</name>
<name>
<surname>Huiskes</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>The prospects of estimating trabecular bone tissue properties from the combination of ultrasound, dual-energy X-ray absorptiometry, microcomputed tomography, and microfinite element analysis</article-title>
<source>
<italic>Journal of Bone and Mineral Research</italic>
</source>
<year>2001</year>
<volume>16</volume>
<issue>3</issue>
<fpage>550</fpage>
<lpage>555</lpage>
<pub-id pub-id-type="pmid">11277273</pub-id>
</element-citation>
</ref>
<ref id="B17">
<label>17</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kanis</surname>
<given-names>JA</given-names>
</name>
</person-group>
<article-title>Osteoporosis III: diagnosis of osteoporosis and assessment of fracture risk</article-title>
<source>
<italic>The Lancet</italic>
</source>
<year>2002</year>
<volume>359</volume>
<issue>9321</issue>
<fpage>1929</fpage>
<lpage>1936</lpage>
</element-citation>
</ref>
<ref id="B18">
<label>18</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Majumdar</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Genant</surname>
<given-names>HK</given-names>
</name>
<name>
<surname>Grampp</surname>
<given-names>S</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Correlation of trabecular bone structure with age, bone mineral density, and osteoporotic status: in vivo studies in the distal radius using high resolution magnetic resonance imaging</article-title>
<source>
<italic>Journal of Bone and Mineral Research</italic>
</source>
<year>1997</year>
<volume>12</volume>
<issue>1</issue>
<fpage>111</fpage>
<lpage>118</lpage>
<pub-id pub-id-type="pmid">9240733</pub-id>
</element-citation>
</ref>
<ref id="B19">
<label>19</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Genant</surname>
<given-names>HK</given-names>
</name>
<name>
<surname>Gordon</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Lang</surname>
<given-names>TF</given-names>
</name>
<name>
<surname>Link</surname>
<given-names>TM</given-names>
</name>
<name>
<surname>Majumdar</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Advanced imaging of bone macro and micro structure</article-title>
<source>
<italic>Bone</italic>
</source>
<year>1999</year>
<volume>25</volume>
<issue>1</issue>
<fpage>149</fpage>
<lpage>152</lpage>
<pub-id pub-id-type="pmid">10423042</pub-id>
</element-citation>
</ref>
<ref id="B20">
<label>20</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rüegsegger</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Koller</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Müller</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>A microtomographic system for the nondestructive evaluation of bone architecture</article-title>
<source>
<italic>Calcified Tissue International</italic>
</source>
<year>1996</year>
<volume>58</volume>
<issue>1</issue>
<fpage>24</fpage>
<lpage>29</lpage>
<pub-id pub-id-type="pmid">8825235</pub-id>
</element-citation>
</ref>
<ref id="B22">
<label>21</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Parfitt</surname>
<given-names>AM</given-names>
</name>
</person-group>
<article-title>Bone histomorphometry: standardization of nomenclature, symbols and units</article-title>
<source>
<italic>Bone</italic>
</source>
<year>1988</year>
<volume>9</volume>
<issue>1</issue>
<fpage>67</fpage>
<lpage>69</lpage>
<pub-id pub-id-type="pmid">3377921</pub-id>
</element-citation>
</ref>
<ref id="B23">
<label>22</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ulrich</surname>
<given-names>D</given-names>
</name>
<name>
<surname>van Rietbergen</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Laib</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Rüegsegger</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone</article-title>
<source>
<italic>Bone</italic>
</source>
<year>1999</year>
<volume>25</volume>
<fpage>55</fpage>
<lpage>60</lpage>
<pub-id pub-id-type="pmid">10423022</pub-id>
</element-citation>
</ref>
<ref id="B24">
<label>23</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Teo</surname>
<given-names>JC</given-names>
</name>
<name>
<surname>Si-Hoe</surname>
<given-names>KM</given-names>
</name>
<name>
<surname>Keh</surname>
<given-names>JE</given-names>
</name>
<name>
<surname>Teoh</surname>
<given-names>SH</given-names>
</name>
</person-group>
<article-title>Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone</article-title>
<source>
<italic>Clinical Biomechanics</italic>
</source>
<year>2006</year>
<volume>21</volume>
<fpage>235</fpage>
<lpage>244</lpage>
<pub-id pub-id-type="pmid">16356612</pub-id>
</element-citation>
</ref>
<ref id="B25">
<label>24</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Feldkamp</surname>
<given-names>LA</given-names>
</name>
<name>
<surname>Goldstein</surname>
<given-names>SA</given-names>
</name>
<name>
<surname>Parfitt</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Jesion</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Kleerekoper</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>The direct examination of three-dimensional bone architecture in vitro by computed tomography</article-title>
<source>
<italic>Journal of Bone and Mineral Research</italic>
</source>
<year>1989</year>
<volume>4</volume>
<fpage>3</fpage>
<lpage>11</lpage>
<pub-id pub-id-type="pmid">2718776</pub-id>
</element-citation>
</ref>
<ref id="B26">
<label>25</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kuhn</surname>
<given-names>JL</given-names>
</name>
<name>
<surname>Goldstein</surname>
<given-names>SA</given-names>
</name>
<name>
<surname>Feldkamp</surname>
<given-names>LA</given-names>
</name>
<name>
<surname>Goulet</surname>
<given-names>RW</given-names>
</name>
<name>
<surname>Jesion</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>Evaluation of a microcomputed tomography system to study trabecular bone structure</article-title>
<source>
<italic>Journal of Orthopaedic Research</italic>
</source>
<year>1990</year>
<volume>8</volume>
<fpage>833</fpage>
<lpage>842</lpage>
<pub-id pub-id-type="pmid">2213340</pub-id>
</element-citation>
</ref>
<ref id="B27">
<label>26</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Swain</surname>
<given-names>MV</given-names>
</name>
<name>
<surname>Xue</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>State of the art of micro-CT applications in dental research</article-title>
<source>
<italic>International Journal of Oral Science</italic>
</source>
<year>2009</year>
<volume>1</volume>
<issue>4</issue>
<fpage>177</fpage>
<lpage>188</lpage>
<pub-id pub-id-type="pmid">20690421</pub-id>
</element-citation>
</ref>
<ref id="B28">
<label>27</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Paulus</surname>
<given-names>MJ</given-names>
</name>
<name>
<surname>Gleason</surname>
<given-names>SS</given-names>
</name>
<name>
<surname>Kennel</surname>
<given-names>SJ</given-names>
</name>
<name>
<surname>Hunsicker</surname>
<given-names>PR</given-names>
</name>
<name>
<surname>Johnson</surname>
<given-names>DK</given-names>
</name>
</person-group>
<article-title>High resolution X-ray computed tomography: an emerging tool for small animal cancer research</article-title>
<source>
<italic>Neoplasia</italic>
</source>
<year>2000</year>
<volume>2</volume>
<issue>1-2</issue>
<fpage>62</fpage>
<lpage>70</lpage>
<pub-id pub-id-type="pmid">10933069</pub-id>
</element-citation>
</ref>
<ref id="B29">
<label>28</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bentley</surname>
<given-names>MD</given-names>
</name>
<name>
<surname>Ortiz</surname>
<given-names>MC</given-names>
</name>
<name>
<surname>Ritman</surname>
<given-names>EL</given-names>
</name>
<name>
<surname>Carlos Romero</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>The use of microcomputed tomography to study microvasculature in small rodents</article-title>
<source>
<italic>American Journal of Physiology</italic>
</source>
<year>2002</year>
<volume>282</volume>
<issue>5</issue>
<fpage>R1267</fpage>
<lpage>R1279</lpage>
<pub-id pub-id-type="pmid">11959666</pub-id>
</element-citation>
</ref>
<ref id="B30">
<label>29</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Holdsworth</surname>
<given-names>DW</given-names>
</name>
<name>
<surname>Thornton</surname>
<given-names>MM</given-names>
</name>
</person-group>
<article-title>Micro-CT in small animal and specimen imaging</article-title>
<source>
<italic>Trends in Biotechnology</italic>
</source>
<year>2002</year>
<volume>20</volume>
<issue>8</issue>
<fpage>S34</fpage>
<lpage>S39</lpage>
</element-citation>
</ref>
<ref id="B31">
<label>30</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Guldberg</surname>
<given-names>RE</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>ASP</given-names>
</name>
<name>
<surname>Coleman</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Robertson</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Duvall</surname>
<given-names>C</given-names>
</name>
</person-group>
<article-title>Microcomputed tomography imaging of skeletal development and growth</article-title>
<source>
<italic>Birth Defects Research Part C</italic>
</source>
<year>2004</year>
<volume>72</volume>
<issue>3</issue>
<fpage>250</fpage>
<lpage>259</lpage>
<pub-id pub-id-type="pmid">15495187</pub-id>
</element-citation>
</ref>
<ref id="B32">
<label>31</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Geckili</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Bilhan</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Bilgin</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>A 24-week prospective study comparing the stability of titanium dioxide grit-blasted dental implants with and without fluoride treatment</article-title>
<source>
<italic>The International Journal of Oral & Maxillofacial Implants</italic>
</source>
<year>2009</year>
<volume>24</volume>
<issue>4</issue>
<fpage>684</fpage>
<lpage>688</lpage>
<pub-id pub-id-type="pmid">19885409</pub-id>
</element-citation>
</ref>
<ref id="B33">
<label>32</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Meredith</surname>
<given-names>N</given-names>
</name>
</person-group>
<article-title>Assessment of implant stability as a prognostic determinant</article-title>
<source>
<italic>The International Journal of Prosthodontics</italic>
</source>
<year>1998</year>
<volume>11</volume>
<fpage>491</fpage>
<lpage>501</lpage>
<pub-id pub-id-type="pmid">9922740</pub-id>
</element-citation>
</ref>
<ref id="B34">
<label>33</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Park</surname>
<given-names>YS</given-names>
</name>
<name>
<surname>Yi</surname>
<given-names>KY</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>IS</given-names>
</name>
<name>
<surname>Jung</surname>
<given-names>YC</given-names>
</name>
</person-group>
<article-title>Correlation between microtomography and histomorphometry for assessment of implant osseointegration</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2005</year>
<volume>16</volume>
<issue>2</issue>
<fpage>156</fpage>
<lpage>160</lpage>
<pub-id pub-id-type="pmid">15777324</pub-id>
</element-citation>
</ref>
<ref id="B35">
<label>34</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Harrigan</surname>
<given-names>TP</given-names>
</name>
<name>
<surname>Jasty</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Mann</surname>
<given-names>RW</given-names>
</name>
<name>
<surname>Harris</surname>
<given-names>WH</given-names>
</name>
</person-group>
<article-title>Limitations of the continuum assumption in cancellous bone</article-title>
<source>
<italic>Journal of Biomechanics</italic>
</source>
<year>1988</year>
<volume>21</volume>
<issue>4</issue>
<fpage>269</fpage>
<lpage>275</lpage>
<pub-id pub-id-type="pmid">3384825</pub-id>
</element-citation>
</ref>
<ref id="B36">
<label>35</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rho</surname>
<given-names>JY</given-names>
</name>
<name>
<surname>Zerwekh</surname>
<given-names>JE</given-names>
</name>
<name>
<surname>Ashman</surname>
<given-names>RB</given-names>
</name>
</person-group>
<article-title>Examination of several techniques for predicting trabecular elastic modulus and ultimate strength in the human lumbar spine</article-title>
<source>
<italic>Clinical Biomechanics</italic>
</source>
<year>1994</year>
<volume>9</volume>
<issue>2</issue>
<fpage>67</fpage>
<lpage>71</lpage>
<pub-id pub-id-type="pmid">23916122</pub-id>
</element-citation>
</ref>
<ref id="B37">
<label>36</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Turkyilmaz</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Sennerby</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Yilmaz</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Bilecenoglu</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Ozbek</surname>
<given-names>EN</given-names>
</name>
</person-group>
<article-title>Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study</article-title>
<source>
<italic>Clinical Implant Dentistry and Related Research</italic>
</source>
<year>2009</year>
<volume>11</volume>
<issue>1</issue>
<fpage>52</fpage>
<lpage>58</lpage>
<pub-id pub-id-type="pmid">18384400</pub-id>
</element-citation>
</ref>
<ref id="B38">
<label>37</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Seong</surname>
<given-names>WJ</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>UK</given-names>
</name>
<name>
<surname>Swift</surname>
<given-names>JQ</given-names>
</name>
<name>
<surname>Heo</surname>
<given-names>YC</given-names>
</name>
<name>
<surname>Hodges</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Ko</surname>
<given-names>CC</given-names>
</name>
</person-group>
<article-title>Elastic properties and apparent density of human edentulous maxilla and mandible</article-title>
<source>
<italic>International Journal of Oral and Maxillofacial Surgery</italic>
</source>
<year>2009</year>
<volume>38</volume>
<issue>10</issue>
<fpage>1088</fpage>
<lpage>1093</lpage>
<pub-id pub-id-type="pmid">19647417</pub-id>
</element-citation>
</ref>
<ref id="B39">
<label>38</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Boskey</surname>
<given-names>AL</given-names>
</name>
<name>
<surname>Cohen</surname>
<given-names>ML</given-names>
</name>
<name>
<surname>Bullough</surname>
<given-names>PG</given-names>
</name>
</person-group>
<article-title>Hard tissue biochemistry: a comparison of fresh-frozen and formalin-fixed tissue samples</article-title>
<source>
<italic>Calcified Tissue International</italic>
</source>
<year>1982</year>
<volume>34</volume>
<issue>4</issue>
<fpage>328</fpage>
<lpage>331</lpage>
<pub-id pub-id-type="pmid">6814720</pub-id>
</element-citation>
</ref>
<ref id="B40">
<label>39</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nimni</surname>
<given-names>ME</given-names>
</name>
<name>
<surname>Cheung</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Strates</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Kodama</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Sheikh</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Chemically modified collagen: a natural biomaterial for tissue replacement</article-title>
<source>
<italic>Journal of Biomedical Materials Research</italic>
</source>
<year>1987</year>
<volume>21</volume>
<issue>6</issue>
<fpage>741</fpage>
<lpage>771</lpage>
<pub-id pub-id-type="pmid">3036880</pub-id>
</element-citation>
</ref>
<ref id="B41">
<label>40</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nuccion</surname>
<given-names>SL</given-names>
</name>
<name>
<surname>Otsuka</surname>
<given-names>NY</given-names>
</name>
<name>
<surname>Davey</surname>
<given-names>JR</given-names>
</name>
</person-group>
<article-title>The effect of freezing and intraosseous fluid on the stiffness behavior of canine trabecular bone</article-title>
<source>
<italic>Orthopedics</italic>
</source>
<year>2001</year>
<volume>24</volume>
<issue>4</issue>
<fpage>375</fpage>
<lpage>380</lpage>
<pub-id pub-id-type="pmid">11332965</pub-id>
</element-citation>
</ref>
<ref id="B42">
<label>41</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wingerter</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Calvert</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Tucci</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Benghuzzi</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Russell</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Puckett</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Mechanical strength repercussions of various fixative storage methods on bone</article-title>
<source>
<italic>Biomedical Sciences Instrumentation</italic>
</source>
<year>2006</year>
<volume>42</volume>
<fpage>290</fpage>
<lpage>295</lpage>
<pub-id pub-id-type="pmid">16817623</pub-id>
</element-citation>
</ref>
<ref id="B43">
<label>42</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cömert</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Kökat</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Akkocaòlu</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Tekdemir</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Akça</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Çehreli</surname>
<given-names>MC</given-names>
</name>
</person-group>
<article-title>Fresh-frozen vs. embalmed bone: is it possible to use formalin-fixed human bone for biomechanical experiments on implants?</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2009</year>
<volume>20</volume>
<issue>5</issue>
<fpage>521</fpage>
<lpage>525</lpage>
<pub-id pub-id-type="pmid">19522977</pub-id>
</element-citation>
</ref>
<ref id="B44">
<label>43</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sedlin</surname>
<given-names>ED</given-names>
</name>
<name>
<surname>Hirsch</surname>
<given-names>C</given-names>
</name>
</person-group>
<article-title>Factors affecting the determination of the physical properties of femoral cortical bone</article-title>
<source>
<italic>Acta Orthopaedica Scandinavica</italic>
</source>
<year>1966</year>
<volume>37</volume>
<issue>1</issue>
<fpage>29</fpage>
<lpage>48</lpage>
<pub-id pub-id-type="pmid">5940056</pub-id>
</element-citation>
</ref>
<ref id="B45">
<label>44</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Currey</surname>
<given-names>JD</given-names>
</name>
<name>
<surname>Brear</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Zioupos</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Reilly</surname>
<given-names>GC</given-names>
</name>
</person-group>
<article-title>Effect of formaldehyde fixation on some mechanical properties of bovine bone</article-title>
<source>
<italic>Biomaterials</italic>
</source>
<year>1995</year>
<volume>16</volume>
<issue>16</issue>
<fpage>1267</fpage>
<lpage>1271</lpage>
<pub-id pub-id-type="pmid">8589198</pub-id>
</element-citation>
</ref>
<ref id="B46">
<label>45</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nazarian</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Hermannsson</surname>
<given-names>BJ</given-names>
</name>
<name>
<surname>Müller</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Zurakowski</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Snyder</surname>
<given-names>BD</given-names>
</name>
</person-group>
<article-title>Effects of tissue preservation on murine bone mechanical properties</article-title>
<source>
<italic>Journal of Biomechanics</italic>
</source>
<year>2009</year>
<volume>42</volume>
<issue>1</issue>
<fpage>82</fpage>
<lpage>86</lpage>
<pub-id pub-id-type="pmid">19081098</pub-id>
</element-citation>
</ref>
<ref id="B47">
<label>46</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chacon</surname>
<given-names>GE</given-names>
</name>
<name>
<surname>Dillard</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Clelland</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Rashid</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Comparison of strains produced by titanium and poly D, L-lactide acid plating systems to in vitro forces</article-title>
<source>
<italic>Journal of Oral and Maxillofacial Surgery</italic>
</source>
<year>2005</year>
<volume>63</volume>
<issue>7</issue>
<fpage>968</fpage>
<lpage>972</lpage>
<pub-id pub-id-type="pmid">16003624</pub-id>
</element-citation>
</ref>
<ref id="B48">
<label>47</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Müller</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Rüegsegger</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Micro-tomographic imaging for the nondestructive evaluation of trabecular bone architecture</article-title>
<source>
<italic>Studies in Health Technology and Informatics</italic>
</source>
<year>1997</year>
<volume>40</volume>
<fpage>61</fpage>
<lpage>79</lpage>
<pub-id pub-id-type="pmid">10168883</pub-id>
</element-citation>
</ref>
<ref id="B49">
<label>48</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cendre</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Mitton</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Roux</surname>
<given-names>JP</given-names>
</name>
<etal></etal>
</person-group>
<article-title>High-resolution computed tomography for architectural characterization of human lumbar cancellous bone: relationships with histomorphometry and biomechanics</article-title>
<source>
<italic>Osteoporosis International</italic>
</source>
<year>1999</year>
<volume>10</volume>
<issue>5</issue>
<fpage>353</fpage>
<lpage>360</lpage>
<pub-id pub-id-type="pmid">10591832</pub-id>
</element-citation>
</ref>
<ref id="B50">
<label>49</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Friberg</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Sennerby</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Roos</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Johansson</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Strid</surname>
<given-names>CG</given-names>
</name>
<name>
<surname>Lekholm</surname>
<given-names>U</given-names>
</name>
</person-group>
<article-title>Evaluation of bone density using cutting resistance measurements and microradiography: an in vitro study in pig ribs</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>1995</year>
<volume>6</volume>
<issue>3</issue>
<fpage>164</fpage>
<lpage>171</lpage>
<pub-id pub-id-type="pmid">7578792</pub-id>
</element-citation>
</ref>
<ref id="B51">
<label>50</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Trisi</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Rao</surname>
<given-names>W</given-names>
</name>
</person-group>
<article-title>Bone classification: clinical—histomorphometric comparison</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>1999</year>
<volume>10</volume>
<issue>1</issue>
<fpage>1</fpage>
<lpage>7</lpage>
<pub-id pub-id-type="pmid">10196784</pub-id>
</element-citation>
</ref>
<ref id="B52">
<label>51</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Norton</surname>
<given-names>MR</given-names>
</name>
<name>
<surname>Gamble</surname>
<given-names>C</given-names>
</name>
</person-group>
<article-title>Bone classification: an objective scale of bone density using the computerized tomography scan</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2001</year>
<volume>12</volume>
<issue>1</issue>
<fpage>79</fpage>
<lpage>84</lpage>
<pub-id pub-id-type="pmid">11168274</pub-id>
</element-citation>
</ref>
<ref id="B53">
<label>52</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Riggs</surname>
<given-names>BL</given-names>
</name>
<name>
<surname>Hodgson</surname>
<given-names>SF</given-names>
</name>
<name>
<surname>O’Fallon</surname>
<given-names>MW</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Effect of fluoride treatment on the fracture rate in postmenopausal women with osteoporosis</article-title>
<source>
<italic>The New England Journal of Medicine</italic>
</source>
<year>1990</year>
<volume>322</volume>
<issue>12</issue>
<fpage>802</fpage>
<lpage>809</lpage>
<pub-id pub-id-type="pmid">2407957</pub-id>
</element-citation>
</ref>
<ref id="B54">
<label>53</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Endo</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Tsunoo</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Nakamori</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Yoshida</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Effect of scattered radiation on image noise in cone beam CT</article-title>
<source>
<italic>Medical Physics</italic>
</source>
<year>2001</year>
<volume>28</volume>
<fpage>469</fpage>
<lpage>474</lpage>
<pub-id pub-id-type="pmid">11339743</pub-id>
</element-citation>
</ref>
<ref id="B55">
<label>54</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yoo</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Yin</surname>
<given-names>FF</given-names>
</name>
</person-group>
<article-title>Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning</article-title>
<source>
<italic>International Journal of Radiation Oncology Biology Physics</italic>
</source>
<year>2006</year>
<volume>66</volume>
<issue>5</issue>
<fpage>1553</fpage>
<lpage>1561</lpage>
</element-citation>
</ref>
<ref id="B58">
<label>55</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sukovic</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Cone beam computed tomography in craniofacial imaging</article-title>
<source>
<italic>Orthodontics and Craniofacial Research</italic>
</source>
<year>2003</year>
<volume>6</volume>
<issue>supplement 1</issue>
<fpage>31</fpage>
<lpage>36</lpage>
<pub-id pub-id-type="pmid">14606532</pub-id>
</element-citation>
</ref>
<ref id="B56">
<label>56</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Becker</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Backer</surname>
<given-names>BE</given-names>
</name>
<name>
<surname>Alsuwyed</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Al-Mubarak</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Long-term evaluation of 282 implants in maxillary and mandibular molar positions: a prospective study</article-title>
<source>
<italic>Journal of Periodontology</italic>
</source>
<year>1999</year>
<volume>70</volume>
<issue>8</issue>
<fpage>896</fpage>
<lpage>901</lpage>
<pub-id pub-id-type="pmid">10476898</pub-id>
</element-citation>
</ref>
<ref id="B57">
<label>57</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Arisan</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Bölükbaşi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Ersanli</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Ozdemir</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>Evaluation of 316 narrow diameter implants followed for 5–10 years: a clinical and radiographic retrospective study</article-title>
<source>
<italic>Clinical Oral Implants Research</italic>
</source>
<year>2010</year>
<volume>21</volume>
<fpage>296</fpage>
<lpage>307</lpage>
<pub-id pub-id-type="pmid">20443792</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
<floats-group>
<fig id="fig1" position="float">
<label>Figure 1</label>
<caption>
<p>Newtom cone beam 3D imaging equipment.</p>
</caption>
<graphic xlink:href="IJD2012-348908.001"></graphic>
</fig>
<fig id="fig2" position="float">
<label>Figure 2</label>
<caption>
<p>The surgical guide which was fabricated on the cast obtained from an impression of the alveolar process of the mandible.</p>
</caption>
<graphic xlink:href="IJD2012-348908.002"></graphic>
</fig>
<fig id="fig3" position="float">
<label>Figure 3</label>
<caption>
<p>Excised bone cylinders using the surgical stent.</p>
</caption>
<graphic xlink:href="IJD2012-348908.003"></graphic>
</fig>
<fig id="fig4" position="float">
<label>Figure 4</label>
<caption>
<p>Excision of bone cylinders from the mandibular body using a slow speed trephine drill.</p>
</caption>
<graphic xlink:href="IJD2012-348908.004"></graphic>
</fig>
<fig id="fig5" position="float">
<label>Figure 5</label>
<caption>
<p>The photograph of the micro-CT scanner.</p>
</caption>
<graphic xlink:href="IJD2012-348908.005"></graphic>
</fig>
<fig id="fig6" position="float">
<label>Figure 6</label>
<caption>
<p>The micro-CT image of the cylinder-shaped bone specimen.</p>
</caption>
<graphic xlink:href="IJD2012-348908.006"></graphic>
</fig>
<table-wrap id="tab1" position="float">
<label>Table 1</label>
<caption>
<p>HU values of the specified regions.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" rowspan="1" colspan="1">Region</th>
<th align="center" colspan="5" rowspan="1">HU values</th>
<th align="center" rowspan="1" colspan="1">HU range</th>
<th align="center" rowspan="1" colspan="1">HU mean</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" rowspan="1" colspan="1">1</td>
<td align="center" rowspan="1" colspan="1">84</td>
<td align="center" rowspan="1" colspan="1">40</td>
<td align="center" rowspan="1" colspan="1">50</td>
<td align="center" rowspan="1" colspan="1">74</td>
<td align="center" rowspan="1" colspan="1">66</td>
<td align="center" rowspan="1" colspan="1">40–84</td>
<td align="center" rowspan="1" colspan="1">62,8</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">2</td>
<td align="center" rowspan="1" colspan="1">32</td>
<td align="center" rowspan="1" colspan="1">61</td>
<td align="center" rowspan="1" colspan="1">44</td>
<td align="center" rowspan="1" colspan="1">30</td>
<td align="center" rowspan="1" colspan="1">22</td>
<td align="center" rowspan="1" colspan="1">22–61</td>
<td align="center" rowspan="1" colspan="1">37,8</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">3</td>
<td align="center" rowspan="1" colspan="1">164</td>
<td align="center" rowspan="1" colspan="1">92</td>
<td align="center" rowspan="1" colspan="1">74</td>
<td align="center" rowspan="1" colspan="1">129</td>
<td align="center" rowspan="1" colspan="1">155</td>
<td align="center" rowspan="1" colspan="1">74–164</td>
<td align="center" rowspan="1" colspan="1">122,8</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">4</td>
<td align="center" rowspan="1" colspan="1">234</td>
<td align="center" rowspan="1" colspan="1">285</td>
<td align="center" rowspan="1" colspan="1">378</td>
<td align="center" rowspan="1" colspan="1">354</td>
<td align="center" rowspan="1" colspan="1">308</td>
<td align="center" rowspan="1" colspan="1">234–378</td>
<td align="center" rowspan="1" colspan="1">311,8</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">5</td>
<td align="center" rowspan="1" colspan="1">742</td>
<td align="center" rowspan="1" colspan="1">614</td>
<td align="center" rowspan="1" colspan="1">534</td>
<td align="center" rowspan="1" colspan="1">586</td>
<td align="center" rowspan="1" colspan="1">408</td>
<td align="center" rowspan="1" colspan="1">408–742</td>
<td align="center" rowspan="1" colspan="1">576,8</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">384</td>
<td align="center" rowspan="1" colspan="1">425</td>
<td align="center" rowspan="1" colspan="1">331</td>
<td align="center" rowspan="1" colspan="1">285</td>
<td align="center" rowspan="1" colspan="1">456</td>
<td align="center" rowspan="1" colspan="1">285–456</td>
<td align="center" rowspan="1" colspan="1">376,2</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">7</td>
<td align="center" rowspan="1" colspan="1">124</td>
<td align="center" rowspan="1" colspan="1">185</td>
<td align="center" rowspan="1" colspan="1">98</td>
<td align="center" rowspan="1" colspan="1">82</td>
<td align="center" rowspan="1" colspan="1">155</td>
<td align="center" rowspan="1" colspan="1">82–185</td>
<td align="center" rowspan="1" colspan="1">128,8</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">8</td>
<td align="center" rowspan="1" colspan="1">24</td>
<td align="center" rowspan="1" colspan="1">66</td>
<td align="center" rowspan="1" colspan="1">62</td>
<td align="center" rowspan="1" colspan="1">14</td>
<td align="center" rowspan="1" colspan="1">26</td>
<td align="center" rowspan="1" colspan="1">14–66</td>
<td align="center" rowspan="1" colspan="1">38,4</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">9</td>
<td align="center" rowspan="1" colspan="1">84</td>
<td align="center" rowspan="1" colspan="1">107</td>
<td align="center" rowspan="1" colspan="1">42</td>
<td align="center" rowspan="1" colspan="1">34</td>
<td align="center" rowspan="1" colspan="1">26</td>
<td align="center" rowspan="1" colspan="1">26–107</td>
<td align="center" rowspan="1" colspan="1">58,6</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>Region 1: right retromolar pad region of human cadaver bone. </p>
</fn>
<fn>
<p>Region 2: right first molar region of human cadaver bone. </p>
</fn>
<fn>
<p>Region 3: right first premolar molar region of human cadaver bone. </p>
</fn>
<fn>
<p>Region 4: right lateral region of human cadaver bone. </p>
</fn>
<fn>
<p>Region 5: midline (symphysis). </p>
</fn>
<fn>
<p>Region 6: left lateral region of human cadaver bone. </p>
</fn>
<fn>
<p>Region 7: left first premolar molar region of human cadaver bone. </p>
</fn>
<fn>
<p>Region 8: left first molar region of human cadaver bone. </p>
</fn>
<fn>
<p>Region 9: left retromolar pad region of human cadaver bone.</p>
</fn>
</table-wrap-foot>
</table-wrap>
</floats-group>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002D42 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 002D42 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3369485
   |texte=   How Precise Is Dental Volumetric Tomography in the Prediction of Bone Density?
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:22693507" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022