Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.
***** Acces problem to record *****\

Identifieur interne : 002B52 ( Pmc/Corpus ); précédent : 002B519; suivant : 002B530 ***** probable Xml problem with record *****

Links to Exploration step


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparative evaluation of linear dimensional changes of four commercially available heat cure acrylic resins</title>
<author>
<name sortKey="Arora, Saryu" sort="Arora, Saryu" uniqKey="Arora S" first="Saryu" last="Arora">Saryu Arora</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Khindaria, S K" sort="Khindaria, S K" uniqKey="Khindaria S" first="S. K." last="Khindaria">S. K. Khindaria</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Garg, Sushant" sort="Garg, Sushant" uniqKey="Garg S" first="Sushant" last="Garg">Sushant Garg</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, M. M. College of Dental Sciences and Research, Mullana, Ambala, India</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Mittal, Sanjay" sort="Mittal, Sanjay" uniqKey="Mittal S" first="Sanjay" last="Mittal">Sanjay Mittal</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, M. M. College of Dental Sciences and Research, Mullana, Ambala, India</italic>
</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">22090761</idno>
<idno type="pmc">3214524</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214524</idno>
<idno type="RBID">PMC:3214524</idno>
<idno type="doi">10.4103/0976-237X.86452</idno>
<date when="2011">2011</date>
<idno type="wicri:Area/Pmc/Corpus">002B52</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002B52</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Comparative evaluation of linear dimensional changes of four commercially available heat cure acrylic resins</title>
<author>
<name sortKey="Arora, Saryu" sort="Arora, Saryu" uniqKey="Arora S" first="Saryu" last="Arora">Saryu Arora</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Khindaria, S K" sort="Khindaria, S K" uniqKey="Khindaria S" first="S. K." last="Khindaria">S. K. Khindaria</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Garg, Sushant" sort="Garg, Sushant" uniqKey="Garg S" first="Sushant" last="Garg">Sushant Garg</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, M. M. College of Dental Sciences and Research, Mullana, Ambala, India</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Mittal, Sanjay" sort="Mittal, Sanjay" uniqKey="Mittal S" first="Sanjay" last="Mittal">Sanjay Mittal</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, M. M. College of Dental Sciences and Research, Mullana, Ambala, India</italic>
</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Contemporary Clinical Dentistry</title>
<idno type="ISSN">0976-237X</idno>
<idno type="eISSN">0976-2361</idno>
<imprint>
<date when="2011">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec id="st1">
<title>Context:</title>
<p>Heat cured acrylic resins undergo dimensional changes during polymerization. Dimensional changes which occur in the heat cure acrylic resins are shrinkage and expansion which affects the fit of the denture and occlusal relationship.</p>
</sec>
<sec id="st2">
<title>Aims:</title>
<p>The purpose of this study was to access the linear dimensional changes of four heat cure acrylic resins before and after curing and compare the changes among four different acrylic brands.</p>
</sec>
<sec id="st3">
<title>Materials and Methods:</title>
<p>Twenty four patients irrespective of age and sex were taken and four commercially available brands were procured. After the teeth arrangement on the mandibular trial denture, two pins were fixed in central fossae of first molar on both sides and one pin in the cingulum of left central incisor. Meliodent heat cure acrylic resin was used in Group A; Trevalon heat cure acrylic resin was used in Group B; Triplex heat cure acrylic resin was used in Group C and Vertex heat cure acrylic resin was used in Group D. Linear measurements of the trial wax up before and after curing and before and after finishing and polishing were measured and compared. Collected data was analyzed with analysis of variance and ‘
<italic>t</italic>
’ test at 95% level of confidence (
<italic>P</italic>
=0.05).</p>
</sec>
<sec id="st4">
<title>Results:</title>
<p>The maximum percentage changes were seen in cases of Group A (Meliodent) followed by Group B, Group C and Group D (Trevalon, Triplex and Vertex). Meliodent showed the highest percentage change i.e. 1.18% and Vertex showed least percentage change of 0.37 %.</p>
</sec>
<sec id="st5">
<title>Conclusions:</title>
<p>Shrinkage occurred after curing and after finishing and polishing, which varies significantly with the four commercially available heat cure acrylic resins. Among the four different brands of heat cure acrylic resin Group D (Vertex) had the least linear dimensional changes after curing and after finishing and polishing, so that D (Vertex) could be the material of choice for fabrication of complete denture among the four brands.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Woelfel, Jb" uniqKey="Woelfel J">JB Woelfel</name>
</author>
<author>
<name sortKey="Paffenbarger, Gc" uniqKey="Paffenbarger G">GC Paffenbarger</name>
</author>
<author>
<name sortKey="Sweeney, Wt" uniqKey="Sweeney W">WT Sweeney</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Becker, Cm" uniqKey="Becker C">CM Becker</name>
</author>
<author>
<name sortKey="Smith, De" uniqKey="Smith D">DE Smith</name>
</author>
<author>
<name sortKey="Nicholls, Ji" uniqKey="Nicholls J">JI Nicholls</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Dixon, Dl" uniqKey="Dixon D">DL Dixon</name>
</author>
<author>
<name sortKey="Breeding, Lc" uniqKey="Breeding L">LC Breeding</name>
</author>
<author>
<name sortKey="Ekstrand, Kg" uniqKey="Ekstrand K">KG Ekstrand</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Stafford, Gd" uniqKey="Stafford G">GD Stafford</name>
</author>
<author>
<name sortKey="Bates, Jf" uniqKey="Bates J">JF Bates</name>
</author>
<author>
<name sortKey="Huggett, R" uniqKey="Huggett R">R Huggett</name>
</author>
<author>
<name sortKey="Handley, Rw" uniqKey="Handley R">RW Handley</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Woelfel, Jb" uniqKey="Woelfel J">JB Woelfel</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Anthony, Dh" uniqKey="Anthony D">DH Anthony</name>
</author>
<author>
<name sortKey="Peyton, Fa" uniqKey="Peyton F">FA Peyton</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Komiyama, O" uniqKey="Komiyama O">O Komiyama</name>
</author>
<author>
<name sortKey="Kawara, M" uniqKey="Kawara M">M Kawara</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Zissis, A" uniqKey="Zissis A">A Zissis</name>
</author>
<author>
<name sortKey="Huggett, R" uniqKey="Huggett R">R Huggett</name>
</author>
<author>
<name sortKey="Harrison, A" uniqKey="Harrison A">A Harrison</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Anusavice, Kj" uniqKey="Anusavice K">KJ Anusavice</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Noort, R" uniqKey="Noort R">R Noort</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Shipee, Rw" uniqKey="Shipee R">RW Shipee</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kinner, Ew" uniqKey="Kinner E">EW Kinner</name>
</author>
<author>
<name sortKey="Cooper, En" uniqKey="Cooper E">EN Cooper</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Contemp Clin Dent</journal-id>
<journal-id journal-id-type="publisher-id">CCD</journal-id>
<journal-title-group>
<journal-title>Contemporary Clinical Dentistry</journal-title>
</journal-title-group>
<issn pub-type="ppub">0976-237X</issn>
<issn pub-type="epub">0976-2361</issn>
<publisher>
<publisher-name>Medknow Publications Pvt Ltd</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">22090761</article-id>
<article-id pub-id-type="pmc">3214524</article-id>
<article-id pub-id-type="publisher-id">CCD-2-182</article-id>
<article-id pub-id-type="doi">10.4103/0976-237X.86452</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Comparative evaluation of linear dimensional changes of four commercially available heat cure acrylic resins</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Arora</surname>
<given-names>Saryu</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
<xref ref-type="corresp" rid="cor1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Khindaria</surname>
<given-names>S. K.</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Garg</surname>
<given-names>Sushant</given-names>
</name>
<xref ref-type="aff" rid="aff2">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Mittal</surname>
<given-names>Sanjay</given-names>
</name>
<xref ref-type="aff" rid="aff2">1</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<italic>Department of Prosthodontics, Swami Devi DyalHospital and Dental College 40, Barwala Panchkula, India</italic>
</aff>
<aff id="aff2">
<label>1</label>
<italic>Department of Prosthodontics, M. M. College of Dental Sciences and Research, Mullana, Ambala, India</italic>
</aff>
<author-notes>
<corresp id="cor1">
<bold>Correspondence:</bold>
Dr. Saryu Arora, H.No. 1152, Sector 7, Panchkulla, India. E-mail:
<email xlink:href="saryuarora@gmail.com">saryuarora@gmail.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<season>Jul-Sep</season>
<year>2011</year>
</pub-date>
<volume>2</volume>
<issue>3</issue>
<fpage>182</fpage>
<lpage>187</lpage>
<permissions>
<copyright-statement>Copyright: © Contemporary Clinical Dentistry</copyright-statement>
<copyright-year>2011</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc-sa/3.0">
<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<sec id="st1">
<title>Context:</title>
<p>Heat cured acrylic resins undergo dimensional changes during polymerization. Dimensional changes which occur in the heat cure acrylic resins are shrinkage and expansion which affects the fit of the denture and occlusal relationship.</p>
</sec>
<sec id="st2">
<title>Aims:</title>
<p>The purpose of this study was to access the linear dimensional changes of four heat cure acrylic resins before and after curing and compare the changes among four different acrylic brands.</p>
</sec>
<sec id="st3">
<title>Materials and Methods:</title>
<p>Twenty four patients irrespective of age and sex were taken and four commercially available brands were procured. After the teeth arrangement on the mandibular trial denture, two pins were fixed in central fossae of first molar on both sides and one pin in the cingulum of left central incisor. Meliodent heat cure acrylic resin was used in Group A; Trevalon heat cure acrylic resin was used in Group B; Triplex heat cure acrylic resin was used in Group C and Vertex heat cure acrylic resin was used in Group D. Linear measurements of the trial wax up before and after curing and before and after finishing and polishing were measured and compared. Collected data was analyzed with analysis of variance and ‘
<italic>t</italic>
’ test at 95% level of confidence (
<italic>P</italic>
=0.05).</p>
</sec>
<sec id="st4">
<title>Results:</title>
<p>The maximum percentage changes were seen in cases of Group A (Meliodent) followed by Group B, Group C and Group D (Trevalon, Triplex and Vertex). Meliodent showed the highest percentage change i.e. 1.18% and Vertex showed least percentage change of 0.37 %.</p>
</sec>
<sec id="st5">
<title>Conclusions:</title>
<p>Shrinkage occurred after curing and after finishing and polishing, which varies significantly with the four commercially available heat cure acrylic resins. Among the four different brands of heat cure acrylic resin Group D (Vertex) had the least linear dimensional changes after curing and after finishing and polishing, so that D (Vertex) could be the material of choice for fabrication of complete denture among the four brands.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Heat cure acrylic resin</kwd>
<kwd>dimensional changes</kwd>
<kwd>complete denture</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="sec1-1">
<title>Introduction</title>
<p>The introduction and use of acrylic resin as a denture base material since 1937 has revolutionized the dentistry in a big way. The resin has fine esthetic properties, is excellent in color and is chemically stable. It can be used with a simple technique for the construction of dentures, but the properties of acrylic resin are not ideal in all aspects. Knowledge of chemistry, physical properties, qualities, characteristics, and manipulative procedure is therefore imperative if reasonably satisfactory results have to be obtained from the use of the material.Dimensional changes which occur in heat cure acrylic resins are shrinkage and expansion which affects the fit of the denture and occlusal relationship.[
<xref ref-type="bibr" rid="ref1">1</xref>
] Precise duplication of trial denture into the final prosthesis is the desired aim during processing in the laboratory. However, certain properties like dimensional inaccuracies of the materials compromise the attainment of this goal optimally. Different authors compared various resins to denture rubber by examining certain physical and mechanical properties of different materials.[
<xref ref-type="bibr" rid="ref2">2</xref>
<xref ref-type="bibr" rid="ref5">5</xref>
]</p>
<p>Considering the importance of dimensional changes occurring during processing, the present study was undertaken to determine linear dimensional changes of four commercially available heat cure acrylic resins.</p>
<sec id="sec2-1">
<title>Aim and Objectives</title>
<p>The present study was designed with the following aim and objectives:</p>
<p>
<list list-type="bullet">
<list-item>
<p>To study the linear dimensional changes of four different brands of heat cure acrylic resins before and after curing.</p>
</list-item>
<list-item>
<p>To compare the linear dimensional changes of heat cure acrylic resin among the four different acrylic brands.</p>
</list-item>
</list>
</p>
</sec>
</sec>
<sec sec-type="materials|methods" id="sec1-2">
<title>Materials and Methods</title>
<p>The study was carried on 24 edentulous subjects, irrespective of age and sex selected from the Department of Prosthodontics including Crown and Bridge, M. M. College of Dental Sciences and Research, Mullana. Thorough diagnosis and case history were recorded for each subject. For each subject, four mandibular complete dentures were fabricated using four different brands of heat cure acrylic resins.</p>
<p>Four different brands of heat cure acrylic resins were used in this study [
<xref ref-type="fig" rid="F1">Figure 1</xref>
]. The brand name and manufacturer's name of heat cure acrylic resins used for the study were as follows and they were grouped from Group A to D as shown in
<xref ref-type="table" rid="T1">Table 1</xref>
.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption>
<p>Four denture base resins</p>
</caption>
<graphic xlink:href="CCD-2-182-g001"></graphic>
</fig>
<table-wrap id="T1" position="float">
<label>Table 1</label>
<caption>
<p>Four different heat cure materials used</p>
</caption>
<graphic xlink:href="CCD-2-182-g002"></graphic>
</table-wrap>
<p>Complete dentures were fabricated for each subject in a conventional manner. For each subject four additional edentulous mandibular casts were duplicated to fabricate four experimental dentures one each from the four different acrylic resins used in the study. Therefore, the edentulous mandibular master cast was duplicated and four additional casts were made for each subject using reversible hydrocolloid agar material. The master cast which was used for the duplication was used to fabricate patient's denture which was delivered to the patient at the end of the treatment. Finally, four mandibular casts for each individual subject were obtained. Following the same procedure for remaining 23 subjects a total of 96 casts were obtained. On the casts so obtained 96 experimental mandibular dentures were fabricated. The teeth set chosen for the study had the same mold. After the teeth arrangement, three stainless steel pins were fixed in mandibular denture with the help of autopolymerizing resin. Out of three pins, two pins were fixed in central fossae of first molar on both sides and one pin in the cingulum of left central incisor so that three measurements between pins can be obtained. The dentures were fabricated using a standard amount of powder liquid ratio of 3:1 and curing the dentures under standardized conditions and opting for a standard routine for polishing [
<xref ref-type="fig" rid="F2">Figure 2</xref>
].</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption>
<p>24 Dentures of one group after fabrication</p>
</caption>
<graphic xlink:href="CCD-2-182-g003"></graphic>
</fig>
<p>The tip of the stainless steel pin was marked with blue color and the marks were transferred onto the paper and the measurements were taken with the help of digital vernier caliper [Figures
<xref ref-type="fig" rid="F3">3</xref>
and
<xref ref-type="fig" rid="F4">4</xref>
] between two points, i.e. molar to molar and molar to central incisor.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption>
<p>Digital vernier caliper</p>
</caption>
<graphic xlink:href="CCD-2-182-g004"></graphic>
</fig>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption>
<p>Measurement of marks after transferring to paper</p>
</caption>
<graphic xlink:href="CCD-2-182-g005"></graphic>
</fig>
<p>Measurements were made between molar pins and central incisor pin.</p>
<p>AB—Left central incisor to right molar.</p>
<p>BC—Right molar to left molar.</p>
<p>CA—Left molar to left central incisor.</p>
<p>The readings between these points were made three times for each of the dentures. The mean of three readings was taken as a single reading to reduce the error. The measurements were taken at three different stages, first after the wax up and carving of trial mandibular denture, second after curing and final reading after finishing and polishing of dentures.</p>
<sec id="sec2-2">
<title>To evaluate linear dimensional changes</title>
<p>So finally three types of readings were taken for each of the processed dentures and same procedure was repeated for remaining 95 experimental dentures.</p>
<p>
<list list-type="bullet">
<list-item>
<p>The differences between pre-cured and cured experimental dentures were analyzed.</p>
</list-item>
<list-item>
<p>The differences between pre-cured and after finishing and polishing were analyzed.</p>
</list-item>
<list-item>
<p>The differences between cured and after finishing and polishing were also analyzed.</p>
</list-item>
</list>
</p>
</sec>
</sec>
<sec id="sec1-3">
<title>Results</title>
<p>
<xref ref-type="table" rid="T2">Table 2</xref>
shows the difference in the linear dimensional changes before and after curing among the groups. The maximum percentage changes were seen in cases of Group-A (meliodent) followed by Group-b, Group-c, and Group-d (trevalon, triplex, and vertex). Out of all the 96 experimental mandibular dentures corresponding to 24 subjects, the experimental dentures cured with Group-A (meliodent) showed the highest percentage change, i.e. 1.18%. The dentures fabricated with Group-D (vertex) showed the percentage change of 0.37% which was the least when compared between all the four heat cure acrylic resins. Group-B and Group-C (trevalon and triplex) showed in between the percentage values of Group-A and Group-D (meliodent and vertex) but in between the two, Group-B (trevalon) had higher percentage value (0.71%) when compared to Group-C (triplex- 0.51%). Linear dimensional changes in all groups are shown in
<xref ref-type="table" rid="T2">Table 2</xref>
.</p>
<table-wrap id="T2" position="float">
<label>Table 2</label>
<caption>
<p>Linear dimensional changes in percentage before and after curing</p>
</caption>
<graphic xlink:href="CCD-2-182-g006"></graphic>
</table-wrap>
<p>
<xref ref-type="table" rid="T3">Table 3</xref>
shows the statistical comparison between before curing and after curing and demonstrates that the results are highly significant at 0.1% level of confidence, i.e. shows a considerable difference between before curing and after curing.</p>
<table-wrap id="T3" position="float">
<label>Table 3</label>
<caption>
<p>Statistical comparison of linear dimensional changes in percentage before and after curing</p>
</caption>
<graphic xlink:href="CCD-2-182-g007"></graphic>
</table-wrap>
<p>
<xref ref-type="table" rid="T4">Table 4</xref>
shows the difference in the linear dimensional changes before curing and after finishing and polishing. The maximum percentage changes were seen in cases of Group-A (meliodent) followed by Group-B, Group-C, and Group-D (trevalon, triplex, and vertex), respectively. Out of all 96 mandibular dentures corresponding to 24 subjects, the dentures cured with Group-A (meliodent) showed the highest percentage value of 1.42%. The dentures fabricated with Group-D (vertex) showed the percent mean value of 0.62% which was the least when compared between all the four heat cure acrylic resins. Group-B and Group-C (trevalon and triplex) heat cured mandibular experimental dentures showed in between the percentage values of Group-A and Group-D (meliodent and vertex), but in between the two also Group-B (trevalon) had higher percentage value (1.18%) when compared to Group-C (triplex-0.81%).</p>
<table-wrap id="T4" position="float">
<label>Table 4</label>
<caption>
<p>Linear dimensional changes in percentage before curing and after finishing and polishing</p>
</caption>
<graphic xlink:href="CCD-2-182-g008"></graphic>
</table-wrap>
<p>
<xref ref-type="table" rid="T5">Table 5</xref>
shows the statistical comparison between before curing and after finishing and polishing and demonstrates that the results are highly significant at 0.1% level of confidence i.e. show considerable difference between before curing and after finishing and polishing.</p>
<table-wrap id="T5" position="float">
<label>Table 5</label>
<caption>
<p>Statistical comparison linear dimensional changes in percentage before curing and after finishing and polishing</p>
</caption>
<graphic xlink:href="CCD-2-182-g009"></graphic>
</table-wrap>
<p>
<xref ref-type="table" rid="T6">Table 6</xref>
shows the difference in the linear dimensional changes after curing and after finishing and polishing. The maximum percentage changes were seen in cases of Group-B (trevalon), followed by Group-C, Group-A, and Group-D (triplex, meliodent, and vertex). Out of all 96 mandibular dentures corresponding to 24 subjects, the experimental dentures cured and finished with Group-B (trevalon heat-cured acrylic resin) showed the highest percentage value, i.e. 0.46%. The denture constructed with Group-D (vertex heat-cured acrylic resin) showed a percentage value of 0.25%, which were the least when compared between all the four groups of heat cure acrylic resins. Group-C and Group-A (triplex and meliodent heat-cured mandibular dentures) showed in between the percentage values of Group-B and Group-D (trevalon and vertex), but in between the two, Group-C (Triplex) had higher percentage value (0.29%) when compared to Group-A (meliodent-0.28%).</p>
<table-wrap id="T6" position="float">
<label>Table 6</label>
<caption>
<p>Linear dimensional changes in percentage after curing and after finishing and polishing</p>
</caption>
<graphic xlink:href="CCD-2-182-g010"></graphic>
</table-wrap>
<p>
<xref ref-type="table" rid="T7">Table 7</xref>
shows the statistical comparison between after curing and after finishing and polishing demonstrates that the results are significant at 0.1% level of confidence, i.e. show a difference between after curing and after finishing and polishing.</p>
<table-wrap id="T7" position="float">
<label>Table 7</label>
<caption>
<p>Statistical comparison linear dimensional changes in percentage after curing and after finishing and polishing</p>
</caption>
<graphic xlink:href="CCD-2-182-g011"></graphic>
</table-wrap>
</sec>
<sec id="sec1-4">
<title>Discussion</title>
<p>The acrylic resin has been very successful as a denture base, as it has fine esthetic properties, excellent color stability, and can be used with a simple technique for the construction of dentures. In spite of having all these advantages, the lack of dimensional stability is widely accepted as one of the disadvantages of acrylic resin dentures. In the processing of dentures, a portion of stress produced in the plastics as they cool below this temperature is relieved when the dentures are separated from the casts, and the amount of shrinkage which occurs is proportional to the range of cooling below the second-order transition temperature.[
<xref ref-type="bibr" rid="ref6">6</xref>
] Komiyama and Kawara[
<xref ref-type="bibr" rid="ref7">7</xref>
] stated that the stress produced by thermal contraction is relieved shortly after the denture has been removed from the mold and that stress, caused by polymerization contraction, will be relieved more gradually. They concluded that the thermal contraction stress is of instantaneous mechanical nature, whereas the stress caused by polymerization is on a molecular level involving polymer chains. Zissis, Huggert, Harrison[
<xref ref-type="bibr" rid="ref8">8</xref>
] embedded steel pins in the wax trial bases and measured distance from the outside of one pin to the outside of the other, with the help of vernier caliper having accuracy 0.001 inch before and after curing.</p>
<p>Woelfel[
<xref ref-type="bibr" rid="ref5">5</xref>
] stated a method of linear measurements on each denture (molar-to-molar) was made at various times at 22 ±1 °C. (72± 2 °F) with a toolmaker's microscope and were recorded to the nearest 0.0025 mm. (0.0001 inch). The reference marks were fine cross lines ruled on polished stainless steel pins cemented in the second molars. Posterior linear measurements instead of contour measurements were made, as shown that linear changes occurring in across the posterior portion of a denture are of significantly greater magnitude than in any other area. Also the changes occurring in the posterior region are the most important in the retention of denture because of the anatomy of the mouth and the shape of the denture. He demonstrated a very small dimensional shrinkage (0.2% to 0.5 % molar-to molar or only 0.1 to 0.2 mm) with heat cured acrylic resin dentures as they were deflasked. Some of the internal stresses from processing are released when the denture is deflasked and polished as it becomes slightly narrower from molar-to molar and flange to flange. This linear shrinkage is invariably small, less than 0.5% (0.2 mm) slightly more on lower dentures than on uppers which are in accordance to the results of present study. It has been reported by Anusavice[
<xref ref-type="bibr" rid="ref9">9</xref>
] that when methyl methacrylate is polymerized the density changes from 0.945 to 1.19 g/cm
<sup>3</sup>
, which results in a volumetric shrinkage of 21% for pure monomer (polymerization shrinkage) during its polymerization. The mixture used for fabrication of dentures apparently contains 1/4 to 1/3 of monomer and as might be expected the volumetric shrinkage will usually range from slightly over 5% to about 7%. Based on a projected volumetric shrinkage of 7%, an acrylic resin denture base should exhibit a linear shrinkage of 2%.[
<xref ref-type="bibr" rid="ref2">2</xref>
]</p>
<p>Anthony and Peyton[
<xref ref-type="bibr" rid="ref6">6</xref>
] inferred that shrinkage might be expected somewhat less in the lower dentures because of the short linear distances between the labial or buccal and the lingual borders. The present study shows the linear shrinkage from 0.25% to 1.42%, which is also in accordance with the study done by Anusavice,[
<xref ref-type="bibr" rid="ref9">9</xref>
] Noort,[
<xref ref-type="bibr" rid="ref10">10</xref>
] and Shippee.[
<xref ref-type="bibr" rid="ref11">11</xref>
] The resins were all found to shrink during the curing process.-[
<xref ref-type="bibr" rid="ref12">12</xref>
] However, on immersion in water, the resins were found to expand. He reported greater shrinkage during processing than during storage in water up to 90 days.</p>
<p>It is assumed that curing shrinkage is entirely thermal in nature and for a given resin composition, it will depend upon the temperature at which the resin becomes sufficiently rigid to contract thermally independent of the cast or model. The present study showed significant linear dimensional changes after curing and after finishing and polishing.</p>
</sec>
<sec id="sec1-5">
<title>Summary and Conclusions</title>
<p>The study was carried out to study the linear dimensional changes of four different heat cure acrylic resins before and after curing, before curing and after finishing and polishing and after curing and after finishing and polishing and to compare the linear dimensional changes of heat cure acrylic resin among four different acrylic brands.</p>
<p>The conclusions drawn from the study are as below.</p>
<p>
<list list-type="bullet">
<list-item>
<p>All the materials showed linear changes immediately after curing and after finishing and polishing.</p>
</list-item>
<list-item>
<p>Among four materials, i.e. meliodent, trevalon, triplex, and vertex maximum percentage changes after curing were seen in Group-A (Meliodent-1.18%) followed by Group-B (trevalon-0.71%), Group-C (triplex-0.51%) and Group-D (vertex-0.37%).</p>
</list-item>
<list-item>
<p>After finishing and polishing, maximum percentage changes were seen in Group-A (meliodent-1.41%), followed by Group-B (trevalon-1.18%), Group-C (triplex-0.80%), and Group-D (vertex-0.61%).</p>
</list-item>
<list-item>
<p>After curing and after finishing and polishing, maximum percentage changes were seen in Group-B (trevalon-0.46%) followed by Group-C (triplex-0.29%), Group-A (meliodent-0.28%), and Group-D (vertex-0.25%).</p>
</list-item>
<list-item>
<p>Among four materials compared, Group-D (vertex) showed the least percentage changes after curing and after finishing and polishing (0.37% and 0.25%).</p>
</list-item>
</list>
</p>
</sec>
</body>
<back>
<fn-group>
<fn fn-type="supported-by">
<p>
<bold>Source of Support:</bold>
Nil</p>
</fn>
<fn fn-type="conflict">
<p>
<bold>Conflict of Interest:</bold>
None declared.</p>
</fn>
</fn-group>
<ref-list>
<ref id="ref1">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Woelfel</surname>
<given-names>JB</given-names>
</name>
<name>
<surname>Paffenbarger</surname>
<given-names>GC</given-names>
</name>
<name>
<surname>Sweeney</surname>
<given-names>WT</given-names>
</name>
</person-group>
<article-title>Dimensional changes occurring in dentures during processing</article-title>
<source>J Am Dent Assoc</source>
<year>1960</year>
<volume>61</volume>
<fpage>413</fpage>
<lpage>30</lpage>
<pub-id pub-id-type="pmid">13786165</pub-id>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Becker</surname>
<given-names>CM</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>DE</given-names>
</name>
<name>
<surname>Nicholls</surname>
<given-names>JI</given-names>
</name>
</person-group>
<article-title>The comparison of denture-base processing techniques. Part II Dimensional changes due to processing</article-title>
<source>J Prosthet Dent</source>
<year>1977</year>
<volume>37</volume>
<fpage>450</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">321759</pub-id>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dixon</surname>
<given-names>DL</given-names>
</name>
<name>
<surname>Breeding</surname>
<given-names>LC</given-names>
</name>
<name>
<surname>Ekstrand</surname>
<given-names>KG</given-names>
</name>
</person-group>
<article-title>Linear dimensional variability of three denture base resins after processing and in water storage</article-title>
<source>J Prosthet Dent</source>
<year>1992</year>
<volume>68</volume>
<fpage>196</fpage>
<lpage>200</lpage>
<pub-id pub-id-type="pmid">1403908</pub-id>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stafford</surname>
<given-names>GD</given-names>
</name>
<name>
<surname>Bates</surname>
<given-names>JF</given-names>
</name>
<name>
<surname>Huggett</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Handley</surname>
<given-names>RW</given-names>
</name>
</person-group>
<article-title>A review of the properties of some denture base polymers</article-title>
<source>J Dent</source>
<year>1980</year>
<volume>8</volume>
<fpage>292</fpage>
<lpage>306</lpage>
<pub-id pub-id-type="pmid">7007459</pub-id>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Woelfel</surname>
<given-names>JB</given-names>
</name>
</person-group>
<article-title>Processing complete dentures</article-title>
<source>Dent Clin North Am</source>
<year>1977</year>
<volume>21</volume>
<fpage>329</fpage>
<lpage>38</lpage>
<pub-id pub-id-type="pmid">321278</pub-id>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Anthony</surname>
<given-names>DH</given-names>
</name>
<name>
<surname>Peyton</surname>
<given-names>FA</given-names>
</name>
</person-group>
<article-title>Dimensional accuracy of various denture base materials</article-title>
<source>J Prosthet Dent</source>
<year>1962</year>
<volume>12</volume>
<fpage>67</fpage>
<lpage>81</lpage>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Komiyama</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Kawara</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Stress relaxation of heat-activated acrylic denture base resin in the mold after processing</article-title>
<source>J Prosthet Dent</source>
<year>1998</year>
<volume>79</volume>
<fpage>175</fpage>
<lpage>81</lpage>
<pub-id pub-id-type="pmid">9513104</pub-id>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zissis</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Huggett</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Harrison</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Measurement methods used for the determination of dimensional accuracy and stability of denture base materials</article-title>
<source>J Dent</source>
<year>1991</year>
<volume>19</volume>
<fpage>199</fpage>
<lpage>206</lpage>
<pub-id pub-id-type="pmid">1787207</pub-id>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Anusavice</surname>
<given-names>KJ</given-names>
</name>
</person-group>
<article-title>Phillip's sciences of dental materials</article-title>
<year>2004</year>
<edition>12th ed</edition>
<publisher-loc>St. Louis</publisher-loc>
<publisher-name>Saunders</publisher-name>
<fpage>721</fpage>
<lpage>57</lpage>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Noort</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Introduction to dental materials</article-title>
<year>2005</year>
<edition>2nd ed</edition>
<publisher-loc>St. Louis</publisher-loc>
<publisher-name>The Mosby Company</publisher-name>
<fpage>214</fpage>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shipee</surname>
<given-names>RW</given-names>
</name>
</person-group>
<article-title>Control of increased vertical dimension of compression-molded dentures</article-title>
<source>J Prosthet Dent</source>
<year>1961</year>
<volume>11</volume>
<fpage>1080</fpage>
<lpage>5</lpage>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kinner</surname>
<given-names>EW</given-names>
</name>
<name>
<surname>Cooper</surname>
<given-names>EN</given-names>
</name>
</person-group>
<article-title>Physical properties of denture base resins: Part I. Curing shrinkage and water sorption</article-title>
<source>J Am Dent Assoc</source>
<year>1943</year>
<volume>30</volume>
<fpage>1845</fpage>
<lpage>52</lpage>
</element-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002B52  | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 002B52  | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     
   |texte=   
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022