Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.
***** Acces problem to record *****\

Identifieur interne : 0025640 ( Pmc/Corpus ); précédent : 0025639; suivant : 0025641 ***** probable Xml problem with record *****

Links to Exploration step


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls</title>
<author>
<name sortKey="Al Ekrish, Asmaa A" sort="Al Ekrish, Asmaa A" uniqKey="Al Ekrish A" first="Asmáa A." last="Al-Ekrish">Asmáa A. Al-Ekrish</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">23960541</idno>
<idno type="pmc">3729286</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729286</idno>
<idno type="RBID">PMC:3729286</idno>
<idno type="doi">10.1016/j.sdentj.2012.05.001</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">002564</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002564</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls</title>
<author>
<name sortKey="Al Ekrish, Asmaa A" sort="Al Ekrish, Asmaa A" uniqKey="Al Ekrish A" first="Asmáa A." last="Al-Ekrish">Asmáa A. Al-Ekrish</name>
</author>
</analytic>
<series>
<title level="j">The Saudi Dental Journal</title>
<idno type="ISSN">1013-9052</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Objectives</title>
<p>To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images.</p>
</sec>
<sec>
<title>Methods</title>
<p>CBCT reformatted images of five skulls were obtained using 40, 20 and 7 s exposure protocols. From these protocols, edentulous ridge dimensions were recorded by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra- and inter-examiner reliability were calculated for each exposure protocol and compared with each other.</p>
</sec>
<sec>
<title>Results</title>
<p>The mean absolute errors from the 40, 20 and 7 s protocols were 0.50, 0.46, and 0.51 mm, respectively. The intra-examiner reliability scores were 0.996, 0.995 and 0.998, respectively. The inter-examiner reliability scores were 0.993, 0.998 and 0.994, respectively. There was no significant difference in accuracy or reliability between the three protocols.</p>
</sec>
<sec>
<title>Conclusions</title>
<p>In imaging of dry skulls, lowering the CBCT exposure time from 40 s to 20 or 7 s does not affect the reliability or accuracy of implant site measurements.</p>
</sec>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Saudi Dent J</journal-id>
<journal-id journal-id-type="iso-abbrev">Saudi Dent J</journal-id>
<journal-title-group>
<journal-title>The Saudi Dental Journal</journal-title>
</journal-title-group>
<issn pub-type="ppub">1013-9052</issn>
<publisher>
<publisher-name>Elsevier</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">23960541</article-id>
<article-id pub-id-type="pmc">3729286</article-id>
<article-id pub-id-type="publisher-id">SDENTJ113</article-id>
<article-id pub-id-type="doi">10.1016/j.sdentj.2012.05.001</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Al-Ekrish</surname>
<given-names>Asmáa A.</given-names>
</name>
<email>asma.alekrish@gmail.com</email>
<email>aalekrish@ksu.edu.sa</email>
</contrib>
</contrib-group>
<aff>Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, P.O. Box 56810, Riyadh 11564, Saudi Arabia</aff>
<pub-date pub-type="pmc-release">
<day>1</day>
<month>6</month>
<year>2012</year>
</pub-date>
<pmc-comment> PMC Release delay is 0 months and 0 days and was based on .</pmc-comment>
<pub-date pub-type="epub">
<day>1</day>
<month>6</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="ppub">
<month>7</month>
<year>2012</year>
</pub-date>
<volume>24</volume>
<issue>3-4</issue>
<fpage>127</fpage>
<lpage>134</lpage>
<history>
<date date-type="received">
<day>24</day>
<month>12</month>
<year>2011</year>
</date>
<date date-type="rev-recd">
<day>26</day>
<month>4</month>
<year>2012</year>
</date>
<date date-type="accepted">
<day>14</day>
<month>5</month>
<year>2012</year>
</date>
</history>
<permissions>
<copyright-statement>© 2012 King Saud University. Production and Hosting by Elsevier B.V. All rights reserved.</copyright-statement>
<copyright-year>2012</copyright-year>
<copyright-holder></copyright-holder>
</permissions>
<abstract>
<sec>
<title>Objectives</title>
<p>To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images.</p>
</sec>
<sec>
<title>Methods</title>
<p>CBCT reformatted images of five skulls were obtained using 40, 20 and 7 s exposure protocols. From these protocols, edentulous ridge dimensions were recorded by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra- and inter-examiner reliability were calculated for each exposure protocol and compared with each other.</p>
</sec>
<sec>
<title>Results</title>
<p>The mean absolute errors from the 40, 20 and 7 s protocols were 0.50, 0.46, and 0.51 mm, respectively. The intra-examiner reliability scores were 0.996, 0.995 and 0.998, respectively. The inter-examiner reliability scores were 0.993, 0.998 and 0.994, respectively. There was no significant difference in accuracy or reliability between the three protocols.</p>
</sec>
<sec>
<title>Conclusions</title>
<p>In imaging of dry skulls, lowering the CBCT exposure time from 40 s to 20 or 7 s does not affect the reliability or accuracy of implant site measurements.</p>
</sec>
</abstract>
<kwd-group>
<title>Keywords</title>
<kwd>CBCT</kwd>
<kwd>Radiation dosage</kwd>
<kwd>Reliability</kwd>
<kwd>Dental implantation</kwd>
<kwd>Dry skull</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 0025640 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 0025640 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     
   |texte=   
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022