Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.
***** Acces problem to record *****\

Identifieur interne : 002279 ( Pmc/Corpus ); précédent : 0022789; suivant : 0022800 ***** probable Xml problem with record *****

Links to Exploration step


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of electric potential and current on mandibular linear measurements in cone beam CT</title>
<author>
<name sortKey="Panmekiate, S" sort="Panmekiate, S" uniqKey="Panmekiate S" first="S" last="Panmekiate">S. Panmekiate</name>
<affiliation>
<nlm:aff id="aff1">
<addr-line>Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand</addr-line>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Apinhasmit, W" sort="Apinhasmit, W" uniqKey="Apinhasmit W" first="W" last="Apinhasmit">W. Apinhasmit</name>
<affiliation>
<nlm:aff id="aff2">
<addr-line>Department of Anatomy, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand</addr-line>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Petersson, A" sort="Petersson, A" uniqKey="Petersson A" first="A" last="Petersson">A. Petersson</name>
<affiliation>
<nlm:aff id="aff3">
<addr-line>Department of Oral Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden</addr-line>
</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">22499132</idno>
<idno type="pmc">3608379</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3608379</idno>
<idno type="RBID">PMC:3608379</idno>
<idno type="doi">10.1259/dmfr/51664704</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">002279</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002279</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Effect of electric potential and current on mandibular linear measurements in cone beam CT</title>
<author>
<name sortKey="Panmekiate, S" sort="Panmekiate, S" uniqKey="Panmekiate S" first="S" last="Panmekiate">S. Panmekiate</name>
<affiliation>
<nlm:aff id="aff1">
<addr-line>Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand</addr-line>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Apinhasmit, W" sort="Apinhasmit, W" uniqKey="Apinhasmit W" first="W" last="Apinhasmit">W. Apinhasmit</name>
<affiliation>
<nlm:aff id="aff2">
<addr-line>Department of Anatomy, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand</addr-line>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Petersson, A" sort="Petersson, A" uniqKey="Petersson A" first="A" last="Petersson">A. Petersson</name>
<affiliation>
<nlm:aff id="aff3">
<addr-line>Department of Oral Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden</addr-line>
</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Dentomaxillofacial Radiology</title>
<idno type="ISSN">0250-832X</idno>
<idno type="eISSN">1476-542X</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Objectives</title>
<p>The purpose of this study was to compare mandibular linear distances measured from cone beam CT (CBCT) images produced by different radiographic parameter settings (peak kilovoltage and milliampere value).</p>
</sec>
<sec>
<title>Methods</title>
<p>20 cadaver hemimandibles with edentulous ridges posterior to the mental foramen were embedded in clear resin blocks and scanned by a CBCT machine (CB MercuRay
<sup>TM</sup>
; Hitachi Medico Technology Corp., Chiba-ken, Japan). The radiographic parameters comprised four peak kilovoltage settings (60 kVp, 80 kVp, 100 kVp and 120 kVp) and two milliampere settings (10 mA and 15 mA). A 102.4 mm field of view was chosen. Each hemimandible was scanned 8 times with 8 different parameter combinations resulting in 160 CBCT data sets. On the cross-sectional images, six linear distances were measured. To assess the intraobserver variation, the 160 data sets were remeasured after 2 weeks. The measurement precision was calculated using Dahlberg's formula. With the same peak kilovoltage, the measurements yielded by different milliampere values were compared using the paired
<italic>t</italic>
-test. With the same milliampere value, the measurements yielded by different peak kilovoltage were compared using analysis of variance. A significant difference was considered when
<italic>p</italic>
< 0.05.</p>
</sec>
<sec>
<title>Results</title>
<p>Measurement precision varied from 0.03 mm to 0.28 mm. No significant differences in the distances were found among the different radiographic parameter combinations.</p>
</sec>
<sec>
<title>Conclusions</title>
<p>Based upon the specific machine in the present study, low peak kilovoltage and milliampere value might be used for linear measurements in the posterior mandible.</p>
</sec>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Dentomaxillofac Radiol</journal-id>
<journal-id journal-id-type="iso-abbrev">Dentomaxillofac Radiol</journal-id>
<journal-id journal-id-type="hwp">dmfr</journal-id>
<journal-id journal-id-type="publisher-id">dmf</journal-id>
<journal-title-group>
<journal-title>Dentomaxillofacial Radiology</journal-title>
</journal-title-group>
<issn pub-type="ppub">0250-832X</issn>
<issn pub-type="epub">1476-542X</issn>
<publisher>
<publisher-name>The British Institute of Radiology.</publisher-name>
<publisher-loc>131–151 Great Titchfield Street, London W1W 5BB</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">22499132</article-id>
<article-id pub-id-type="pmc">3608379</article-id>
<article-id pub-id-type="publisher-id">D11125</article-id>
<article-id pub-id-type="doi">10.1259/dmfr/51664704</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Effect of electric potential and current on mandibular linear measurements in cone beam CT</article-title>
<alt-title alt-title-type="running-head">Measurements in CBCT</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Panmekiate</surname>
<given-names>S</given-names>
</name>
<xref ref-type="corresp" rid="cor1">*</xref>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Apinhasmit</surname>
<given-names>W</given-names>
</name>
<xref ref-type="aff" rid="aff2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Petersson</surname>
<given-names>A</given-names>
</name>
<xref ref-type="aff" rid="aff3">3</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<label>1</label>
<addr-line>Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand</addr-line>
</aff>
<aff id="aff2">
<label>2</label>
<addr-line>Department of Anatomy, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand</addr-line>
</aff>
<aff id="aff3">
<label>3</label>
<addr-line>Department of Oral Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden</addr-line>
</aff>
<author-notes>
<corresp id="cor1">Dr S Panmekiate, Department of Radiology, Faculty of Dentistry, Chulalongkorn University, 34 Henri-Dunant Road, Pathumwan, Bangkok 10330, Thailand. E-mail:
<email>psoontra@chula.ac.th</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<month>10</month>
<year>2012</year>
</pub-date>
<volume>41</volume>
<issue>7</issue>
<fpage>578</fpage>
<lpage>582</lpage>
<history>
<date date-type="received">
<day>13</day>
<month>4</month>
<year>2011</year>
</date>
<date date-type="rev-recd">
<day>10</day>
<month>10</month>
<year>2011</year>
</date>
<date date-type="accepted">
<day>10</day>
<month>10</month>
<year>2011</year>
</date>
</history>
<permissions>
<copyright-statement>© 2012 The British Institute of Radiology</copyright-statement>
<copyright-year>2012</copyright-year>
</permissions>
<abstract>
<sec>
<title>Objectives</title>
<p>The purpose of this study was to compare mandibular linear distances measured from cone beam CT (CBCT) images produced by different radiographic parameter settings (peak kilovoltage and milliampere value).</p>
</sec>
<sec>
<title>Methods</title>
<p>20 cadaver hemimandibles with edentulous ridges posterior to the mental foramen were embedded in clear resin blocks and scanned by a CBCT machine (CB MercuRay
<sup>TM</sup>
; Hitachi Medico Technology Corp., Chiba-ken, Japan). The radiographic parameters comprised four peak kilovoltage settings (60 kVp, 80 kVp, 100 kVp and 120 kVp) and two milliampere settings (10 mA and 15 mA). A 102.4 mm field of view was chosen. Each hemimandible was scanned 8 times with 8 different parameter combinations resulting in 160 CBCT data sets. On the cross-sectional images, six linear distances were measured. To assess the intraobserver variation, the 160 data sets were remeasured after 2 weeks. The measurement precision was calculated using Dahlberg's formula. With the same peak kilovoltage, the measurements yielded by different milliampere values were compared using the paired
<italic>t</italic>
-test. With the same milliampere value, the measurements yielded by different peak kilovoltage were compared using analysis of variance. A significant difference was considered when
<italic>p</italic>
< 0.05.</p>
</sec>
<sec>
<title>Results</title>
<p>Measurement precision varied from 0.03 mm to 0.28 mm. No significant differences in the distances were found among the different radiographic parameter combinations.</p>
</sec>
<sec>
<title>Conclusions</title>
<p>Based upon the specific machine in the present study, low peak kilovoltage and milliampere value might be used for linear measurements in the posterior mandible.</p>
</sec>
</abstract>
<kwd-group>
<kwd>cone-beam computed tomography</kwd>
<kwd>dental implants</kwd>
<kwd>mandible</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002279  | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 002279  | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     
   |texte=   
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022