<title xml:lang="en">Biofunctional prosthetic system: A new era complete denture</title>
<author>
<name sortKey="Saini, Vandana" sort="Saini, Vandana" uniqKey="Saini V" first="Vandana" last="Saini">Vandana Saini</name>
<affiliation>
<nlm:aff id="AF0001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Singla, Ruchi" sort="Singla, Ruchi" uniqKey="Singla R" first="Ruchi" last="Singla">Ruchi Singla</name>
<affiliation>
<nlm:aff id="AF0001"></nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">21430969</idno>
<idno type="pmc">3053518</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3053518</idno>
<idno type="RBID">PMC:3053518</idno>
<idno type="doi">10.4103/0975-7406.76505</idno>
<date when="2011">2011</date>
<idno type="wicri:Area/Pmc/Corpus">002008</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002008</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Biofunctional prosthetic system: A new era complete denture</title>
<author>
<name sortKey="Saini, Vandana" sort="Saini, Vandana" uniqKey="Saini V" first="Vandana" last="Saini">Vandana Saini</name>
<affiliation>
<nlm:aff id="AF0001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Singla, Ruchi" sort="Singla, Ruchi" uniqKey="Singla R" first="Ruchi" last="Singla">Ruchi Singla</name>
<affiliation>
<nlm:aff id="AF0001"></nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of Pharmacy and Bioallied Sciences</title>
<idno type="ISSN">0976-4879</idno>
<idno type="eISSN">0975-7406</idno>
<imprint>
<date when="2011">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Roraff, Ar" uniqKey="Roraff A">AR Roraff</name>
</author>
<author>
<name sortKey="Stansbury, Be" uniqKey="Stansbury B">BE Stansbury</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Patel, Bn" uniqKey="Patel B">BN Patel</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="letter">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Pharm Bioallied Sci</journal-id>
<journal-id journal-id-type="publisher-id">JPBS</journal-id>
<journal-title-group>
<journal-title>Journal of Pharmacy and Bioallied Sciences</journal-title>
</journal-title-group>
<issn pub-type="ppub">0976-4879</issn>
<issn pub-type="epub">0975-7406</issn>
<publisher>
<publisher-name>Medknow Publications</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">21430969</article-id>
<article-id pub-id-type="pmc">3053518</article-id>
<article-id pub-id-type="publisher-id">JPBS-3-170b</article-id>
<article-id pub-id-type="doi">10.4103/0975-7406.76505</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Letters</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Biofunctional prosthetic system: A new era complete denture</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Saini</surname>
<given-names>Vandana</given-names>
</name>
<xref ref-type="aff" rid="AF0001"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Singla</surname>
<given-names>Ruchi</given-names>
</name>
<xref ref-type="aff" rid="AF0001"></xref>
</contrib>
</contrib-group>
<aff id="AF0001">Faculty of Dentistry, Dr. H.S.J. Dental College, Punjab University, Chandigarh, India. E-mail:
<email xlink:href="teena2982@yahoo.co.in">teena2982@yahoo.co.in</email>
</aff>
<pub-date pub-type="ppub">
<season>Jan-Mar</season>
<year>2011</year>
</pub-date>
<volume>3</volume>
<issue>1</issue>
<fpage seq="b">170</fpage>
<lpage>172</lpage>
<permissions>
<copyright-statement>© Journal of Pharmacy and Bioallied Sciences</copyright-statement>
<copyright-year>2011</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/2.0/">
<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
</article-meta>
</front>
<body>
<p>Sir,</p>
<p>This clinical report describes the prosthetic rehabilitation of an edentulous patient,who was dissatisfied from her 8-year-old denture. To give her a better fit, we opted Biofunctional Prosthetic System (BPS) for the new prosthesis. BPS is the system designed to work with the body in a biologically harmonious way, maximizing function, and giving comfort and natural appearance to the patient. The functional impression technique and simulation of the jaw movements by the Stratos 200 articulator in BPS ensure that BPS denture meets most exacting requirements.[
<xref ref-type="bibr" rid="CIT1">1</xref>
]</p>
<p>BPS denture meets the esthetic demand of patients with its unique Ivoclear teeth, which replicate anatomy of the natural tooth Ivoclear teeth are made up of 3 layers of cross-linked acrylic resins that contribute to a life-like appearance and resistance to wearing. BPS system uses a controlled heat/pressure polymerization procedure during which time the exact amount of material flows into the flask to compensate for shrinkage, which ensures a perfect fit. This pressure also optimizes the physical properties of the denture. [
<xref ref-type="bibr" rid="CIT2">2</xref>
]</p>
<p>A 60-year-old edentulous woman with a chief complaint of compromised function and esthetics was treated in the clinic. Intraoral examination showed resorbed ridges and masticatory dysfunction [
<xref ref-type="fig" rid="F0001">Figure 1</xref>
]. An extraoral examination revealed flattened mandibular plane. She was wearing dentures with attrited teeth and worn out denture base. A significant loss of vertical dimension affected the temporomandibular joint. Hence, a BPS denture was planned to give her a better fitted prosthesis.
<fig id="F0001" position="float">
<label>Figure 1</label>
<caption>
<p>Resorbed ridges</p>
</caption>
<graphic xlink:href="JPBS-3-170b-g001"></graphic>
</fig>
</p>
<p>The BPS recommends impression making similar in principle to the mucostatic method that minimally compresses tissues, using a combination of irreversible hydrocolloids of varying densities together in the same impression.[
<xref ref-type="bibr" rid="CIT3">3</xref>
] Low-density impression material (syringe Acc Gel) was syringed into the vestibular area and the occlusal centric tray was loaded with high-density hydrocolloid and inserted into the patient’s mouth to get the initial vertical dimension [
<xref ref-type="fig" rid="F0002">Figure 2</xref>
]. This vertical dimension was used for mounting the casts obtained from initial impressions, taken with Accu-trays (different from conventional denture trays) with an extra flange to cover the vestibular areas and extended distal part to cover the retromandibular pad area more efficiently [
<xref ref-type="fig" rid="F0003">Figure 3</xref>
]. Custom trays were made on the primary casts. The Gnathometer M tracing device was attached to the casts, which facilitates the clinical procedures of secondary impression making, face-bow record and jaw registration [
<xref ref-type="fig" rid="F0004">Figure 4</xref>
].
<fig id="F0002" position="float">
<label>Figure 2</label>
<caption>
<p>Occlussal centric tray loaded with impression for recording initial vertical dimension</p>
</caption>
<graphic xlink:href="JPBS-3-170b-g002"></graphic>
</fig>
<fig id="F0003" position="float">
<label>Figure 3</label>
<caption>
<p>Biofunctional prosthetic system impression trays</p>
</caption>
<graphic xlink:href="JPBS-3-170b-g003"></graphic>
</fig>
<fig id="F0004" position="float">
<label>Figure 4</label>
<caption>
<p>Bite registration through Gnathometer M</p>
</caption>
<graphic xlink:href="JPBS-3-170b-g004"></graphic>
</fig>
</p>
<p>The secondary impression was taken with zinc oxide eugenol impression paste [
<xref ref-type="fig" rid="F0005">Figure 5</xref>
]. Casts were poured and a wax-up denture was made for the trial [
<xref ref-type="fig" rid="F0006">Figure 6</xref>
]. After checking the fit and occlussal relations, the denture was sent to the laboratory. Dentures were cured with injection molding technique [
<xref ref-type="fig" rid="F0007">Figure 7</xref>
] using Ivocap high-impact plus denture base material.[
<xref ref-type="bibr" rid="CIT4">4</xref>
] Necessary adjustments were done and the dentures were delivered to the patient.
<fig id="F0005" position="float">
<label>Figure 5</label>
<caption>
<p>Secondary impression-making with zinc oxide eugenol paste</p>
</caption>
<graphic xlink:href="JPBS-3-170b-g005"></graphic>
</fig>
<fig id="F0006" position="float">
<label>Figure 6</label>
<caption>
<p>Wax-up trial for the patient</p>
</caption>
<graphic xlink:href="JPBS-3-170b-g006"></graphic>
</fig>
<fig id="F0007" position="float">
<label>Figure 7</label>
<caption>
<p>Acrylized denture</p>
</caption>
<graphic xlink:href="JPBS-3-170b-g007"></graphic>
</fig>
</p>
<p>The patient was recalled after 6 months and examined. There was no occlusal disharmony or sore spots. The patient was very much satisfied with her new prosthesis and she showed her gratification for the comfortable prosthesis and a younger look.</p>
</body>
<back>
<ack>
<p>We are grateful to Mr. Chauhan, Dental Technician, Chauhan Dental Lab, Sec-32, Chandigarh, India, for his laboratory work.</p>
</ack>
<ref-list>
<ref id="CIT1">
<label>1</label>
<element-citation publication-type="other">
<comment>Available from: BPS Dentures smilebydesign_in Best Dentist In Delhi[Last cited in 2010]</comment>
</element-citation>
</ref>
<ref id="CIT2">
<label>2</label>
<element-citation publication-type="other">
<comment>Available from:
<ext-link ext-link-type="uri" xlink:href="http://www.familydentalhealthcentre.com/completedenture">http://www.familydentalhealthcentre.com/completedenture</ext-link>
[Last cited in 2010]</comment>
</element-citation>
</ref>
<ref id="CIT3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roraff</surname>
<given-names>AR</given-names>
</name>
<name>
<surname>Stansbury</surname>
<given-names>BE</given-names>
</name>
</person-group>
<article-title>Errors caused by dimensional change in mounting materials</article-title>
<source>J Prosthet Dent</source>
<year>1972</year>
<volume>28</volume>
<fpage>247</fpage>
<lpage>52</lpage>
<pub-id pub-id-type="pmid">4558968</pub-id>
</element-citation>
</ref>
<ref id="CIT4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Patel</surname>
<given-names>BN</given-names>
</name>
</person-group>
<article-title>Acrylic removable prosthesis- an integral part of modern Day Dentistry</article-title>
<source>Famdent</source>
<year>2005</year>
<volume>6</volume>
<fpage>62</fpage>
<lpage>4</lpage>
</element-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 0020080 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 0020080 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     
   |texte=   
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022