Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.
***** Acces problem to record *****\

Identifieur interne : 001C06 ( Pmc/Corpus ); précédent : 001C059; suivant : 001C070 ***** probable Xml problem with record *****

Links to Exploration step


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Full mouth rehabilitation of a patient with mandibular implant screw retained Fp-3 prosthesis opposing maxillary acrylic removable over-denture</title>
<author>
<name sortKey="Jain, Ashish R" sort="Jain, Ashish R" uniqKey="Jain A" first="Ashish R." last="Jain">Ashish R. Jain</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Nallaswamy, Deepak" sort="Nallaswamy, Deepak" uniqKey="Nallaswamy D" first="Deepak" last="Nallaswamy">Deepak Nallaswamy</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, Saveetha Dental College, Saveetha University, Chennai, Tamil Nadu, India</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Ariga, Padma" sort="Ariga, Padma" uniqKey="Ariga P" first="Padma" last="Ariga">Padma Ariga</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, Saveetha Dental College, Saveetha University, Chennai, Tamil Nadu, India</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Philip, Jacob Mathew" sort="Philip, Jacob Mathew" uniqKey="Philip J" first="Jacob Mathew" last="Philip">Jacob Mathew Philip</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">24015016</idno>
<idno type="pmc">3757889</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757889</idno>
<idno type="RBID">PMC:3757889</idno>
<idno type="doi">10.4103/0976-237X.114862</idno>
<date when="2013">2013</date>
<idno type="wicri:Area/Pmc/Corpus">001C06</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">001C06</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Full mouth rehabilitation of a patient with mandibular implant screw retained Fp-3 prosthesis opposing maxillary acrylic removable over-denture</title>
<author>
<name sortKey="Jain, Ashish R" sort="Jain, Ashish R" uniqKey="Jain A" first="Ashish R." last="Jain">Ashish R. Jain</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Nallaswamy, Deepak" sort="Nallaswamy, Deepak" uniqKey="Nallaswamy D" first="Deepak" last="Nallaswamy">Deepak Nallaswamy</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, Saveetha Dental College, Saveetha University, Chennai, Tamil Nadu, India</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Ariga, Padma" sort="Ariga, Padma" uniqKey="Ariga P" first="Padma" last="Ariga">Padma Ariga</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Prosthodontics, Saveetha Dental College, Saveetha University, Chennai, Tamil Nadu, India</italic>
</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Philip, Jacob Mathew" sort="Philip, Jacob Mathew" uniqKey="Philip J" first="Jacob Mathew" last="Philip">Jacob Mathew Philip</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Contemporary Clinical Dentistry</title>
<idno type="ISSN">0976-237X</idno>
<idno type="eISSN">0976-2361</idno>
<imprint>
<date when="2013">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>A hybrid denture is one that is fabricated over a metal framework and retained by screws threaded into the implant abutments. The anterior part of a mandibular hybrid denture is fixed on implants while the posterior part of the denture is extended and cantilevered from implants. This article presents the fabrication of a maxillary over-denture opposing mandibular implant retained hybrid prosthesis. A total of four implants were placed in the mandibular arch. Castable abutments were used to produce the optimal angulations. Framework was waxed, cast recovered, and the fit was refined until the framework seated passively on the master cast. The mandibular denture teeth were waxed to the hybrid framework, and a final wax try-in was performed to verify and correct maxillomandibular relations before processing. The prosthesis was inserted after verification of occlusion, retention, and stability. The rehabilitation of edentulous patients with hybrid dentures has been observed to achieve greater masticatory function and psychological satisfaction than with conventional over-dentures. Producing a passive-fitting substructure for a fixed removable screw retained hybrid prosthesis is arguably one of the most technically complex tasks in implant dentistry. The technique presented may not initially produce a perfectly passive framework, but use of disclosing media and adjusting the internal aspect of the casting can result in non-binding, fully seated prostheses.</p>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Goll, Ge" uniqKey="Goll G">GE Goll</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Zarb, Ga" uniqKey="Zarb G">GA Zarb</name>
</author>
<author>
<name sortKey="Symington, Jm" uniqKey="Symington J">JM Symington</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Zarb, Ga" uniqKey="Zarb G">GA Zarb</name>
</author>
<author>
<name sortKey="Schmitt, A" uniqKey="Schmitt A">A Schmitt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kan, Jy" uniqKey="Kan J">JY Kan</name>
</author>
<author>
<name sortKey="Rungcharassaeng, K" uniqKey="Rungcharassaeng K">K Rungcharassaeng</name>
</author>
<author>
<name sortKey="Bohsali, K" uniqKey="Bohsali K">K Bohsali</name>
</author>
<author>
<name sortKey="Goodacre, Cj" uniqKey="Goodacre C">CJ Goodacre</name>
</author>
<author>
<name sortKey="Lang, Br" uniqKey="Lang B">BR Lang</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Taylor, Td" uniqKey="Taylor T">TD Taylor</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Goodacre, Cj" uniqKey="Goodacre C">CJ Goodacre</name>
</author>
<author>
<name sortKey="Kan, Jy" uniqKey="Kan J">JY Kan</name>
</author>
<author>
<name sortKey="Rungcharassaeng, K" uniqKey="Rungcharassaeng K">K Rungcharassaeng</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Skalak, R" uniqKey="Skalak R">R Skalak</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Br Nemark, Pi" uniqKey="Br Nemark P">PI Brånemark</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Naert, I" uniqKey="Naert I">I Naert</name>
</author>
<author>
<name sortKey="Quirynen, M" uniqKey="Quirynen M">M Quirynen</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" uniqKey="Van Steenberghe D">D van Steenberghe</name>
</author>
<author>
<name sortKey="Darius, P" uniqKey="Darius P">P Darius</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lekholm, U" uniqKey="Lekholm U">U Lekholm</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" uniqKey="Van Steenberghe D">D van Steenberghe</name>
</author>
<author>
<name sortKey="Herrmann, I" uniqKey="Herrmann I">I Herrmann</name>
</author>
<author>
<name sortKey="Bolender, C" uniqKey="Bolender C">C Bolender</name>
</author>
<author>
<name sortKey="Folmer, T" uniqKey="Folmer T">T Folmer</name>
</author>
<author>
<name sortKey="Gunne, J" uniqKey="Gunne J">J Gunne</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bauman, Gr" uniqKey="Bauman G">GR Bauman</name>
</author>
<author>
<name sortKey="Mills, M" uniqKey="Mills M">M Mills</name>
</author>
<author>
<name sortKey="Rapley, Jw" uniqKey="Rapley J">JW Rapley</name>
</author>
<author>
<name sortKey="Hallmon, Ww" uniqKey="Hallmon W">WW Hallmon</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Haanaes, Hr" uniqKey="Haanaes H">HR Haanaes</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="case-report">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Contemp Clin Dent</journal-id>
<journal-id journal-id-type="iso-abbrev">Contemp Clin Dent</journal-id>
<journal-id journal-id-type="publisher-id">CCD</journal-id>
<journal-title-group>
<journal-title>Contemporary Clinical Dentistry</journal-title>
</journal-title-group>
<issn pub-type="ppub">0976-237X</issn>
<issn pub-type="epub">0976-2361</issn>
<publisher>
<publisher-name>Medknow Publications & Media Pvt Ltd</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">24015016</article-id>
<article-id pub-id-type="pmc">3757889</article-id>
<article-id pub-id-type="publisher-id">CCD-4-231</article-id>
<article-id pub-id-type="doi">10.4103/0976-237X.114862</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Case Report</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Full mouth rehabilitation of a patient with mandibular implant screw retained Fp-3 prosthesis opposing maxillary acrylic removable over-denture</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Jain</surname>
<given-names>Ashish R.</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
<xref ref-type="corresp" rid="cor1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Nallaswamy</surname>
<given-names>Deepak</given-names>
</name>
<xref ref-type="aff" rid="aff2">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ariga</surname>
<given-names>Padma</given-names>
</name>
<xref ref-type="aff" rid="aff2">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Philip</surname>
<given-names>Jacob Mathew</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
</contrib>
</contrib-group>
<aff id="aff1">
<italic>Department of Prosthodontics, Crown & Bridge, and Implantology, Tagore Dental College and Hospital, Rathinamangalam, Vandalur Post, Chennai, Tamil Nadu, India</italic>
</aff>
<aff id="aff2">
<label>1</label>
<italic>Department of Prosthodontics, Saveetha Dental College, Saveetha University, Chennai, Tamil Nadu, India</italic>
</aff>
<author-notes>
<corresp id="cor1">
<bold>Correspondence:</bold>
Dr. Ashish R. Jain, R House c1, No. 3, Manonmani Ammal Road, Pavapur, Kilpauk, Chennai - 600 010, Tamil Nadu, India. E-mail:
<email xlink:href="dr.ashishjain_r@yahoo.com">dr.ashishjain_r@yahoo.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<season>Apr-Jun</season>
<year>2013</year>
</pub-date>
<volume>4</volume>
<issue>2</issue>
<fpage>231</fpage>
<lpage>235</lpage>
<permissions>
<copyright-statement>Copyright: © Contemporary Clinical Dentistry</copyright-statement>
<copyright-year>2013</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc-sa/3.0">
<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<p>A hybrid denture is one that is fabricated over a metal framework and retained by screws threaded into the implant abutments. The anterior part of a mandibular hybrid denture is fixed on implants while the posterior part of the denture is extended and cantilevered from implants. This article presents the fabrication of a maxillary over-denture opposing mandibular implant retained hybrid prosthesis. A total of four implants were placed in the mandibular arch. Castable abutments were used to produce the optimal angulations. Framework was waxed, cast recovered, and the fit was refined until the framework seated passively on the master cast. The mandibular denture teeth were waxed to the hybrid framework, and a final wax try-in was performed to verify and correct maxillomandibular relations before processing. The prosthesis was inserted after verification of occlusion, retention, and stability. The rehabilitation of edentulous patients with hybrid dentures has been observed to achieve greater masticatory function and psychological satisfaction than with conventional over-dentures. Producing a passive-fitting substructure for a fixed removable screw retained hybrid prosthesis is arguably one of the most technically complex tasks in implant dentistry. The technique presented may not initially produce a perfectly passive framework, but use of disclosing media and adjusting the internal aspect of the casting can result in non-binding, fully seated prostheses.</p>
</abstract>
<kwd-group>
<kwd>Hybrid prosthesis</kwd>
<kwd>implant occlusion</kwd>
<kwd>passive fit</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="sec1-1">
<title>Introduction</title>
<p>Mandibular implant-supported hybrid prostheses have been used for edentulous patients who could not adapt to long-term use of conventional complete dentures. A hybrid denture is one that is fabricated over a metal framework and retained by screws threaded into the implant abutments. The anterior part of a mandibular hybrid denture is fixed on implants while the posterior part of the denture is extended and cantilevered from implants. Unfavorable occlusal loading on the extension has been reported to cause loosening and breakage of screws and prosthetic posts, framework fracture, and implant loss. Loading is determined primarily by the length of the lever arms and distal extensions.[
<xref ref-type="bibr" rid="ref1">1</xref>
] It has been suggested that the extension from the midpoint of the most distal implant must not exceed 15 mm in the mandible. Others believe that the distal extension must not go beyond the first molars. Therefore, the hybrid denture often has fewer posterior teeth than a conventional complete denture, and the distribution of occlusal loads in the hybrid denture may be different from those in the conventional denture.[
<xref ref-type="bibr" rid="ref2">2</xref>
]</p>
<p>Finger and Guerra proposed that when implants are placed in one arch there is the possibility of rendering an opposing complete denture unstable. Zarb and Schmitt[
<xref ref-type="bibr" rid="ref3">3</xref>
] suggested that the imbalance in stress resolution may lead to rapid resorption of the alveolar ridge in the maxillary arch. However, there is a little quantitative analysis on the distribution of occlusal loads and the stability of a maxillary denture opposed by a hybrid denture.</p>
</sec>
<sec id="sec1-2">
<title>Aim</title>
<p>This article presents the fabrication of a maxillary over-denture opposing mandibular implant retained hybrid prosthesis.</p>
</sec>
<sec id="sec1-3">
<title>Case Report</title>
<p>A 52-year-old white woman was initially seen with an existing maxillary tooth supported over-denture opposing edentulous mandibular arch [
<xref ref-type="fig" rid="F1">Figure 1</xref>
]. The patient had initiated treatment previously with a general dentist, but decided to seek specialty care for the completion of her treatment. Fabrication of screw retained hybrid prosthesis was planned for the mandibular arch and a new over-denture for maxillary arch. The unfavorable sinus anatomy in the posterior maxilla and patient's unwillingness for bone grafting to facilitate implant placement precluded the placement of implants in the maxillary arch [
<xref ref-type="fig" rid="F2">Figure 2</xref>
]. The treatment options presented to the patient also included the fabrication of an implant-supported over-denture, but the patient's desire was to eliminate a removable prosthesis in the mandible. The following clinical and laboratory procedures were performed.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption>
<p>Pre-operative photograph</p>
</caption>
<graphic xlink:href="CCD-4-231-g001"></graphic>
</fig>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption>
<p>OPG (Orthopantomograph) with radiographic markers in place</p>
</caption>
<graphic xlink:href="CCD-4-231-g002"></graphic>
</fig>
<sec id="sec2-1">
<title>Stage I implant surgery</title>
<p>A full thickness mucoperiosteal flap was raised in the mandibular arch from distal to mental foramen on one side to mental foramen on the other side. In the right quadrant, implants (Tapered self-thread, Hi-Tech Implants, and Life care implant system) were placed in the 2
<sup>nd</sup>
premolar (4.2 mm × 10 mm), lateral incisor (4.2 mm × 10 mm) regions. In the left quadrant, implants were placed in 2
<sup>nd</sup>
premolar (4.2 mm × 10 mm), lateral incisor (4.2 mm × 10 mm) and regions. The implant dimensions were selected with the help of a computed tomography scan and 3D reconstructive image [
<xref ref-type="fig" rid="F3">Figure 3</xref>
]. A total of four implants were placed in the mandibular arch with a help of surgical stent. The flap was closed using the horizontal interrupted sutures. After 1 week, the sutures were removed and an immediate denture was relined with a permanent soft denture liner (Permasoft, Dentsply, York, PA, USA) and inserted.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption>
<p>Computed tomography scan to determine the width and height of bone</p>
</caption>
<graphic xlink:href="CCD-4-231-g003"></graphic>
</fig>
</sec>
<sec id="sec2-2">
<title>Stage II implant surgery</title>
<p>After a waiting period of 4 months, an (Orthopantomograph 10E, Siemens) OPG was obtained to evaluate the bone to implant contact percentage [
<xref ref-type="fig" rid="F4">Figure 4</xref>
] and later stage II surgery was performed under local anesthesia cover screws were exposed and healing abutments were placed and the flap sutured.</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption>
<p>Radiograph after 6 months of implant placement</p>
</caption>
<graphic xlink:href="CCD-4-231-g004"></graphic>
</fig>
</sec>
<sec id="sec2-3">
<title>Prosthetic phase</title>
<p>Maxillary and mandibular arch impressions were made using alginate (Tulip Alginate Impression Material, Cavex, Holland Bv, Haarlem, Holland). A conventional special tray was fabricated for the maxillary arch and a custom open tray was fabricated in acrylic resin (Autopolymerizing acrylic resin, ALIKE™; GC America, ALSIP, USA) for the mandibular arch. The open tray was verified in the patient's mouth. After 1 week, the healing abutments were removed, and impression copings were connected to the implants (Impression Coping Pick-up Type, 4 mm Profile; 3i Implant Innovations, Palm Beach Gardens, Fla.). These open tray impressions copings were stabilized with 23 gauge ortho wire and blocked out with acrylic resin (Autopolymerizing acrylic resin, ALIKE™; GC America, ALSIP, USA). The mandibular impression was made with monophase polyvinyl siloxane impression material (Aquasil Lv Ultra, Smart Wetting Impression Material, Dentsply, Detrey Gmbh, Konstanz, Germany). Border molding was completed with green stick compound and secondary impression was made using addition silicone impression material (Aquasil Lv Ultra, Smart Wetting Impression Material, Dentsply, Detrey Gmbh, Konstanz, Germany) for the maxillary arch. The impressions were poured in die stone (Ultrarock, Kalabhai Karson Pvt. Ltd., Mumbai, India) Master casts were recovered and trimmed and record bases and occlusion rims were fabricated. Patient returned for recording of maxillomandibular relations and tooth selection. Master casts were then mounted on a semiadjustable articulator (Hanau Modular Articulator System, Waterpik Technologies Inc., Fort Collins, Colo.). The path of insertion deviated considerably, so castable abutments were used to produce the optimal angulations. Wax up for framework fabrication was carried out. The framework was waxed, cast, recovered, and fitted on the master cast. Disclosing media (Kerr's Disclosing Wax; Kerr, Romulus, Mich. and Occlude; Pascal Co Inc., Bellevue, Wash.) were used to evaluate the fit of the framework and to guide adjustment procedures. The fit was refined until the framework seated passively on the master cast. The metal framework was tried in to evaluate and verify a passive fit intra-orally [
<xref ref-type="fig" rid="F5">Figure 5</xref>
]. Disclosing media was used to discern any fit discrepancies. Adjustments were performed, and abutments were removed from the implant fixtures and healing abutments reconnected. The mandibular denture teeth were waxed to the hybrid framework, and a final wax try-in was performed to verify and correct maxillomandibular relations. At this appointment, the customized abutments along with the framework were connected to the implants for the final wax try-in. At this time an OPG was made to evaluate the fit between frameworks and implant interface [
<xref ref-type="fig" rid="F6">Figure 6</xref>
]. The maxillary tooth supported over-denture was invested/flasked and processed by use of the maxillary master cast as any conventional complete denture. However, the mandibular hybrid prosthesis was invested without the master cast. The internal aspects of the casting that fit on the abutments were blocked out with the polyvinyl-siloxane impression material, and the prosthesis was invested directly into the lower half of the processing flask. The investing, flasking, and processing procedures were then completed. The prostheses were finished and polished, a clinical remount was performed to allow for refinement of occlusal contacts, the hybrid prosthesis was screw retained and provisional cement (Temp Bond; Kerr) was used to cover screw access hole. Maxillary over-denture and Mandibular hybrid prosthesis were inserted [
<xref ref-type="fig" rid="F7">Figure 7</xref>
]. Hygiene techniques were reviewed, and patient was scheduled for recall and maintenance.</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption>
<p>Framework trial intra-orally</p>
</caption>
<graphic xlink:href="CCD-4-231-g005"></graphic>
</fig>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption>
<p>OPG after framework placement</p>
</caption>
<graphic xlink:href="CCD-4-231-g006"></graphic>
</fig>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption>
<p>(a) Maxillary and mandibular prosthesis in place. (b) Maxillary occlusal view. (c) Mandibular occlusal view</p>
</caption>
<graphic xlink:href="CCD-4-231-g007"></graphic>
</fig>
</sec>
<sec id="sec2-4">
<title>Occlusion and articulation</title>
<p>Occlusion was evaluated using guided closure and was considered as: Good, if centric relation (CR) coincided with centric occlusion (CO); moderate, if minor (<0.5 mm) deviation was observed between CR and CO; poor, if clear (>0.5 mm) deviation was observed between CR and CO. Articulation was considered as good when it was fully balanced during lateral movements performed from CO, otherwise it was considered poor. Presence or absence of frontal contact in CO was also noted.[
<xref ref-type="bibr" rid="ref4">4</xref>
<xref ref-type="bibr" rid="ref5">5</xref>
]</p>
</sec>
<sec id="sec2-5">
<title>Retention and stability</title>
<p>Retention of the maxillary tooth supported over-denture was examined using the following scores: (1) good = good resistance to vertical pull, and sufficient resistance to lateral forces; (2) satisfactory = slight to moderate resistance to vertical pull, and little or no resistance to lateral forces; and (3) poor = no resistance to vertical pull and lateral forces; the denture falls out of place. Stability was determined with the following criteria: (1) good = slight or no rocking on denture-supporting structures when under pressure; (2) moderate = moderate rocking on supporting structures under pressure; and (3) poor = extreme rocking on supporting structures under pressure.[
<xref ref-type="bibr" rid="ref6">6</xref>
<xref ref-type="bibr" rid="ref7">7</xref>
]</p>
</sec>
</sec>
<sec sec-type="discussion" id="sec1-4">
<title>Discussion</title>
<p>Jacobs
<italic>et al</italic>
.[
<xref ref-type="bibr" rid="ref8">8</xref>
] found greater annual maxillary bone resorption in patients with mandibular implant supported fixed prostheses than in patients with mandibular over-dentures supported by two implants. A maxillary complete denture occluding with a hybrid denture has also been said to increase vulnerability to midline fracture. Based on these findings, it is recommended that the stability and retention of a maxillary denture be checked more often and the occlusion adjusted more frequently to relieve anterior tilting for the hybrid denture wearer.</p>
<p>Producing a passive-fitting substructure for fixed removable screw retained hybrid prosthesis is arguably one of the most technically complex tasks in implant dentistry. In spite of a number of techniques to prevent or correct distortions that occur during impression making, cast pouring, waxing, casting, indexing, and soldering, errors in the fit of frameworks persist.[
<xref ref-type="bibr" rid="ref9">9</xref>
] The gap between an implant fixture and an abutment should be 10 m or less to be considered passive.[
<xref ref-type="bibr" rid="ref10">10</xref>
] This degree of fit may be almost impossible with the geometry of most screw-retained fixed detachable hybrid prostheses. The technique presented may not initially produce a perfectly passive framework, but use of disclosing media and adjusting the internal aspect of the casting can result in non-binding, fully seated prostheses. Disclosing media were used to evaluate the fit of the framework on the implant abutments in the same manner as are used to ensure complete seating and passivity for conventional fixed and removable partial dentures. Adjustments to the internal surfaces of the framework can then be made to eliminate binding as in conventional prostheses. Although the possibility exists that sectioning, indexing, and soldering may be required to obtain a passive-fitting substructure of this design, modification of the internal aspects should be sufficient in the majority of situations. There may be several disadvantages of this technique. First, selection, and milling of modification (prepable) abutments requires an experienced clinician and technician working together with adequate communication. Implant angulations beyond 15 degrees may require an angled abutment or a castable abutment to achieve an acceptable path of insertion. Furthermore, numbering or other methods of matching the correct abutment and orientation with the correct implant fixture is imperative. Patients with limited inter-arch space may present several problems. It may result in a framework with deficient thickness or insufficient space for setting denture teeth.</p>
<p>The rehabilitation of edentulous patients with hybrid dentures has been observed to achieve greater masticatory function and psychological satisfaction than with conventional over-dentures.[
<xref ref-type="bibr" rid="ref11">11</xref>
] Occlusal forces have been increased considerably following the placement of an implant-supported prosthesis. Many investigators have studied occlusal force measurements in patients with implant-supported prostheses opposing complete maxillary dentures, but their force measurements vary significantly.[
<xref ref-type="bibr" rid="ref12">12</xref>
]</p>
<sec id="sec2-6">
<title>Clinical significance</title>
<p>Producing a passive-fitting substructure for fixed removable screw retained hybrid prosthesis is arguably one of the most technically complex tasks in implant dentistry. The technique presented may not initially produce a perfectly passive framework, but use of disclosing media and adjusting the internal aspect of the casting can result in non-binding, fully seated prostheses. To preserve maxillary bone, a balanced occlusal concept has been recommended for implant-retained mandibular hybrid prostheses opposing a tooth supported maxillary over-denture.[
<xref ref-type="bibr" rid="ref10">10</xref>
] In this case, the patient was rehabilitated with a balanced occlusion without anterior tooth contact in maximal intercuspation. If anterior contact was noticed during the annual recall examination, the occlusion was adjusted to relieve the pressure from the anterior maxilla.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="sec1-5">
<title>Conclusion</title>
<p>Every patient has unique treatment needs. Proper diagnosis and treatment plan are important but cannot be all-inclusive. A comprehensive examination, including a thorough medical and dental history, orofacial and dental clinical examination, dental radiographs, impressions, and jaw relation records for mounting casts are important steps leading to a successful oral rehabilitation. Careful integration and sequencing of the different areas of treatment needed, enhances the final result. Dentists must consider the advantages and disadvantages the available implant prosthetic options and match them to patient's expectations. This article reports on the fabrication of a maxillary over-denture opposing a mandibular implant-Screw retained hybrid prosthesis. Occlusion and articulation were found to be good over a period of 2 years. Retention and stability were found to be good up till the 18 month review and moderate at the 24 month review.</p>
</sec>
</body>
<back>
<fn-group>
<fn fn-type="supported-by">
<p>
<bold>Source of Support:</bold>
Nil</p>
</fn>
<fn fn-type="conflict">
<p>
<bold>Conflict of Interest:</bold>
None declared</p>
</fn>
</fn-group>
<ref-list>
<ref id="ref1">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goll</surname>
<given-names>GE</given-names>
</name>
</person-group>
<article-title>Production of accurately fitting full-arch implant frameworks: Part I – Clinical procedures</article-title>
<source>J Prosthet Dent</source>
<year>1991</year>
<volume>66</volume>
<fpage>377</fpage>
<lpage>84</lpage>
<pub-id pub-id-type="pmid">1800736</pub-id>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zarb</surname>
<given-names>GA</given-names>
</name>
<name>
<surname>Symington</surname>
<given-names>JM</given-names>
</name>
</person-group>
<article-title>Osseointegrated dental implants: Preliminary report on a replication study</article-title>
<source>J Prosthet Dent</source>
<year>1983</year>
<volume>50</volume>
<fpage>271</fpage>
<lpage>6</lpage>
<pub-id pub-id-type="pmid">6352914</pub-id>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zarb</surname>
<given-names>GA</given-names>
</name>
<name>
<surname>Schmitt</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered</article-title>
<source>J Prosthet Dent</source>
<year>1990</year>
<volume>64</volume>
<fpage>185</fpage>
<lpage>94</lpage>
<pub-id pub-id-type="pmid">2202818</pub-id>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kan</surname>
<given-names>JY</given-names>
</name>
<name>
<surname>Rungcharassaeng</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Bohsali</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Goodacre</surname>
<given-names>CJ</given-names>
</name>
<name>
<surname>Lang</surname>
<given-names>BR</given-names>
</name>
</person-group>
<article-title>Clinical methods for evaluating implant framework fit</article-title>
<source>J Prosthet Dent</source>
<year>1999</year>
<volume>81</volume>
<fpage>7</fpage>
<lpage>13</lpage>
<pub-id pub-id-type="pmid">9878969</pub-id>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Taylor</surname>
<given-names>TD</given-names>
</name>
</person-group>
<article-title>Prosthodontic problems and limitations associated with osseointegration</article-title>
<source>J Prosthet Dent</source>
<year>1998</year>
<volume>79</volume>
<fpage>74</fpage>
<lpage>8</lpage>
<pub-id pub-id-type="pmid">9474545</pub-id>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goodacre</surname>
<given-names>CJ</given-names>
</name>
<name>
<surname>Kan</surname>
<given-names>JY</given-names>
</name>
<name>
<surname>Rungcharassaeng</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Clinical complications of osseointegrated implants</article-title>
<source>J Prosthet Dent</source>
<year>1999</year>
<volume>81</volume>
<fpage>537</fpage>
<lpage>52</lpage>
<pub-id pub-id-type="pmid">10220658</pub-id>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Skalak</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Biomechanical considerations in osseointegrated prostheses</article-title>
<source>J Prosthet Dent</source>
<year>1983</year>
<volume>49</volume>
<fpage>843</fpage>
<lpage>8</lpage>
<pub-id pub-id-type="pmid">6576140</pub-id>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Brånemark</surname>
<given-names>PI</given-names>
</name>
</person-group>
<article-title>Osseointegration and its experimental background</article-title>
<source>J Prosthet Dent</source>
<year>1983</year>
<volume>50</volume>
<fpage>399</fpage>
<lpage>410</lpage>
<pub-id pub-id-type="pmid">6352924</pub-id>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Naert</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Quirynen</surname>
<given-names>M</given-names>
</name>
<name>
<surname>van Steenberghe</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Darius</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects</article-title>
<source>J Prosthet Dent</source>
<year>1992</year>
<volume>68</volume>
<fpage>949</fpage>
<lpage>56</lpage>
<pub-id pub-id-type="pmid">1494126</pub-id>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lekholm</surname>
<given-names>U</given-names>
</name>
<name>
<surname>van Steenberghe</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Herrmann</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Bolender</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Folmer</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Gunne</surname>
<given-names>J</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5-year multicenter study</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>1994</year>
<volume>9</volume>
<fpage>627</fpage>
<lpage>35</lpage>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bauman</surname>
<given-names>GR</given-names>
</name>
<name>
<surname>Mills</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Rapley</surname>
<given-names>JW</given-names>
</name>
<name>
<surname>Hallmon</surname>
<given-names>WW</given-names>
</name>
</person-group>
<article-title>Plaque-induced inflammation around implants</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>1992</year>
<volume>7</volume>
<fpage>330</fpage>
<lpage>7</lpage>
<pub-id pub-id-type="pmid">1289258</pub-id>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Haanaes</surname>
<given-names>HR</given-names>
</name>
</person-group>
<article-title>Implants and infections with special reference to oral bacteria</article-title>
<source>J Clin Periodontol</source>
<year>1990</year>
<volume>17</volume>
<fpage>516</fpage>
<lpage>24</lpage>
<pub-id pub-id-type="pmid">2202750</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001C06  | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 001C06  | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     
   |texte=   
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022