Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT

Identifieur interne : 000C27 ( Pmc/Corpus ); précédent : 000C26; suivant : 000C28

Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT

Auteurs : J. K. Dusseldorp ; H. C. Stamatakis ; Y. Ren

Source :

RBID : PMC:5360826

Abstract

Objectives

The aim of this study is to investigate the effect of soft tissue presence on the segmentation accuracy of the 3D hard tissue models from cone-beam computed tomography (CBCT).

Materials and methods

Seven pairs of CBCT Digital Imaging and Communication in Medicine (DICOM) datasets, containing data of human cadaver heads and their respective dry skulls, were used. The effect of the soft tissue presence on the accuracy of the segmented models was evaluated by performing linear and angular measurements and by superimposition and color mapping of the surface discrepancies after splitting the mandible and maxillo-facial complex in the midsagittal plane.

Results

The linear and angular measurements showed significant differences for the more posterior transversal measurements on the mandible (p < 0.01). By splitting and superimposing the maxillo-facial complex, the mean root-mean-square error (RMSE) as a measurement of inaccuracy decreased insignificantly from 0.936 to 0.922 mm (p > 0.05). The RMSE value for the mandible, however, significantly decreased from 1.240 to 0.981 mm after splitting (p < 0.01).

Conclusions

The soft tissue presence seems to affect the accuracy of the 3D hard tissue model obtained from a cone-beam CT, below a generally accepted level of clinical significance of 1 mm. However, this level of accuracy may not meet the requirement for applications where high precision is paramount.

Clinical relevance

Accuracy of CBCT-based 3D surface-rendered models, especially of the hard tissues, are crucial in several dental and medical applications, such as implant planning and virtual surgical planning on patients undergoing orthognathic and navigational surgeries. When used in applications where high precision is paramount, the effect of soft tissue presence should be taken into consideration during the segmentation process.


Url:
DOI: 10.1007/s00784-016-1844-x
PubMed: 27206862
PubMed Central: 5360826

Links to Exploration step

PMC:5360826

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT</title>
<author>
<name sortKey="Dusseldorp, J K" sort="Dusseldorp, J K" uniqKey="Dusseldorp J" first="J. K." last="Dusseldorp">J. K. Dusseldorp</name>
<affiliation>
<nlm:aff id="Aff1">Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, UMCG, 9700 RB Groningen, The Netherlands</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Stamatakis, H C" sort="Stamatakis, H C" uniqKey="Stamatakis H" first="H. C." last="Stamatakis">H. C. Stamatakis</name>
<affiliation>
<nlm:aff id="Aff1">Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, UMCG, 9700 RB Groningen, The Netherlands</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Ren, Y" sort="Ren, Y" uniqKey="Ren Y" first="Y." last="Ren">Y. Ren</name>
<affiliation>
<nlm:aff id="Aff1">Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, UMCG, 9700 RB Groningen, The Netherlands</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">27206862</idno>
<idno type="pmc">5360826</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360826</idno>
<idno type="RBID">PMC:5360826</idno>
<idno type="doi">10.1007/s00784-016-1844-x</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">000C27</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000C27</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT</title>
<author>
<name sortKey="Dusseldorp, J K" sort="Dusseldorp, J K" uniqKey="Dusseldorp J" first="J. K." last="Dusseldorp">J. K. Dusseldorp</name>
<affiliation>
<nlm:aff id="Aff1">Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, UMCG, 9700 RB Groningen, The Netherlands</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Stamatakis, H C" sort="Stamatakis, H C" uniqKey="Stamatakis H" first="H. C." last="Stamatakis">H. C. Stamatakis</name>
<affiliation>
<nlm:aff id="Aff1">Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, UMCG, 9700 RB Groningen, The Netherlands</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Ren, Y" sort="Ren, Y" uniqKey="Ren Y" first="Y." last="Ren">Y. Ren</name>
<affiliation>
<nlm:aff id="Aff1">Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, UMCG, 9700 RB Groningen, The Netherlands</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Clinical Oral Investigations</title>
<idno type="ISSN">1432-6981</idno>
<idno type="eISSN">1436-3771</idno>
<imprint>
<date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Objectives</title>
<p>The aim of this study is to investigate the effect of soft tissue presence on the segmentation accuracy of the 3D hard tissue models from cone-beam computed tomography (CBCT).</p>
</sec>
<sec>
<title>Materials and methods</title>
<p>Seven pairs of CBCT Digital Imaging and Communication in Medicine (DICOM) datasets, containing data of human cadaver heads and their respective dry skulls, were used. The effect of the soft tissue presence on the accuracy of the segmented models was evaluated by performing linear and angular measurements and by superimposition and color mapping of the surface discrepancies after splitting the mandible and maxillo-facial complex in the midsagittal plane.</p>
</sec>
<sec>
<title>Results</title>
<p>The linear and angular measurements showed significant differences for the more posterior transversal measurements on the mandible (
<italic>p</italic>
 < 0.01). By splitting and superimposing the maxillo-facial complex, the mean root-mean-square error (RMSE) as a measurement of inaccuracy decreased insignificantly from 0.936 to 0.922 mm (
<italic>p</italic>
 > 0.05). The RMSE value for the mandible, however, significantly decreased from 1.240 to 0.981 mm after splitting (
<italic>p</italic>
 < 0.01).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>The soft tissue presence seems to affect the accuracy of the 3D hard tissue model obtained from a cone-beam CT, below a generally accepted level of clinical significance of 1 mm. However, this level of accuracy may not meet the requirement for applications where high precision is paramount.</p>
</sec>
<sec>
<title>Clinical relevance</title>
<p>Accuracy of CBCT-based 3D surface-rendered models, especially of the hard tissues, are crucial in several dental and medical applications, such as implant planning and virtual surgical planning on patients undergoing orthognathic and navigational surgeries. When used in applications where high precision is paramount, the effect of soft tissue presence should be taken into consideration during the segmentation process.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Kaeppler, G" uniqKey="Kaeppler G">G Kaeppler</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="De Waard, O" uniqKey="De Waard O">O de Waard</name>
</author>
<author>
<name sortKey="Rangel, Fa" uniqKey="Rangel F">FA Rangel</name>
</author>
<author>
<name sortKey="Fudalej, Ps" uniqKey="Fudalej P">PS Fudalej</name>
</author>
<author>
<name sortKey="Bronkhorst, Em" uniqKey="Bronkhorst E">EM Bronkhorst</name>
</author>
<author>
<name sortKey="Kuijpers Jagtman, Am" uniqKey="Kuijpers Jagtman A">AM Kuijpers-Jagtman</name>
</author>
<author>
<name sortKey="Breuning, Kh" uniqKey="Breuning K">KH Breuning</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Paniagua, B" uniqKey="Paniagua B">B Paniagua</name>
</author>
<author>
<name sortKey="Cevidanes, L" uniqKey="Cevidanes L">L Cevidanes</name>
</author>
<author>
<name sortKey="Walker, D" uniqKey="Walker D">D Walker</name>
</author>
<author>
<name sortKey="Zhu, H" uniqKey="Zhu H">H Zhu</name>
</author>
<author>
<name sortKey="Guo, R" uniqKey="Guo R">R Guo</name>
</author>
<author>
<name sortKey="Styner, M" uniqKey="Styner M">M Styner</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hatcher, Dc" uniqKey="Hatcher D">DC Hatcher</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Alhadidi, A" uniqKey="Alhadidi A">A AlHadidi</name>
</author>
<author>
<name sortKey="Cevidanes, Lh" uniqKey="Cevidanes L">LH Cevidanes</name>
</author>
<author>
<name sortKey="Mol, A" uniqKey="Mol A">A Mol</name>
</author>
<author>
<name sortKey="Ludlow, J" uniqKey="Ludlow J">J Ludlow</name>
</author>
<author>
<name sortKey="Styner, M" uniqKey="Styner M">M Styner</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Luu, Ns" uniqKey="Luu N">NS Luu</name>
</author>
<author>
<name sortKey="Nikolcheva, Lg" uniqKey="Nikolcheva L">LG Nikolcheva</name>
</author>
<author>
<name sortKey="Retrouvey, Jm" uniqKey="Retrouvey J">JM Retrouvey</name>
</author>
<author>
<name sortKey="Flores Mir, C" uniqKey="Flores Mir C">C Flores-Mir</name>
</author>
<author>
<name sortKey="El Bialy, T" uniqKey="El Bialy T">T El-Bialy</name>
</author>
<author>
<name sortKey="Carey, Jp" uniqKey="Carey J">JP Carey</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="O Eil, M" uniqKey="O Eil M">M O’Neil</name>
</author>
<author>
<name sortKey="Khambay, B" uniqKey="Khambay B">B Khambay</name>
</author>
<author>
<name sortKey="Bowman, A" uniqKey="Bowman A">A Bowman</name>
</author>
<author>
<name sortKey="Moos, Kf" uniqKey="Moos K">KF Moos</name>
</author>
<author>
<name sortKey="Barbenel, J" uniqKey="Barbenel J">J Barbenel</name>
</author>
<author>
<name sortKey="Walker, F" uniqKey="Walker F">F Walker</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tucker, S" uniqKey="Tucker S">S Tucker</name>
</author>
<author>
<name sortKey="Cevidanes, Lh" uniqKey="Cevidanes L">LH Cevidanes</name>
</author>
<author>
<name sortKey="Styner, M" uniqKey="Styner M">M Styner</name>
</author>
<author>
<name sortKey="Kim, H" uniqKey="Kim H">H Kim</name>
</author>
<author>
<name sortKey="Reyes, M" uniqKey="Reyes M">M Reyes</name>
</author>
<author>
<name sortKey="Proffit, W" uniqKey="Proffit W">W Proffit</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Oh, Km" uniqKey="Oh K">KM Oh</name>
</author>
<author>
<name sortKey="Seo, Sk" uniqKey="Seo S">SK Seo</name>
</author>
<author>
<name sortKey="Park, Je" uniqKey="Park J">JE Park</name>
</author>
<author>
<name sortKey="Sim, Hs" uniqKey="Sim H">HS Sim</name>
</author>
<author>
<name sortKey="Cevidanes, Lh" uniqKey="Cevidanes L">LH Cevidanes</name>
</author>
<author>
<name sortKey="Kim, Yj" uniqKey="Kim Y">YJ Kim</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Marmulla, R" uniqKey="Marmulla R">R Marmulla</name>
</author>
<author>
<name sortKey="Hoppe, H" uniqKey="Hoppe H">H Hoppe</name>
</author>
<author>
<name sortKey="Muhling, J" uniqKey="Muhling J">J Muhling</name>
</author>
<author>
<name sortKey="Eggers, G" uniqKey="Eggers G">G Eggers</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Swennen, Gr" uniqKey="Swennen G">GR Swennen</name>
</author>
<author>
<name sortKey="Mollemans, W" uniqKey="Mollemans W">W Mollemans</name>
</author>
<author>
<name sortKey="Schutyser, F" uniqKey="Schutyser F">F Schutyser</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Cevidanes, Lh" uniqKey="Cevidanes L">LH Cevidanes</name>
</author>
<author>
<name sortKey="Tucker, S" uniqKey="Tucker S">S Tucker</name>
</author>
<author>
<name sortKey="Styner, M" uniqKey="Styner M">M Styner</name>
</author>
<author>
<name sortKey="Kim, H" uniqKey="Kim H">H Kim</name>
</author>
<author>
<name sortKey="Chapuis, J" uniqKey="Chapuis J">J Chapuis</name>
</author>
<author>
<name sortKey="Reyes, M" uniqKey="Reyes M">M Reyes</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Zinser, Mj" uniqKey="Zinser M">MJ Zinser</name>
</author>
<author>
<name sortKey="Mischkowski, Ra" uniqKey="Mischkowski R">RA Mischkowski</name>
</author>
<author>
<name sortKey="Sailer, Hf" uniqKey="Sailer H">HF Sailer</name>
</author>
<author>
<name sortKey="Zoller, Je" uniqKey="Zoller J">JE Zoller</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Van Der Meer, Wj" uniqKey="Van Der Meer W">WJ Van der Meer</name>
</author>
<author>
<name sortKey="Raghoebar, Gm" uniqKey="Raghoebar G">GM Raghoebar</name>
</author>
<author>
<name sortKey="Gerrits, Po" uniqKey="Gerrits P">PO Gerrits</name>
</author>
<author>
<name sortKey="Noorda, Wd" uniqKey="Noorda W">WD Noorda</name>
</author>
<author>
<name sortKey="Vissink, A" uniqKey="Vissink A">A Vissink</name>
</author>
<author>
<name sortKey="Visser, A" uniqKey="Visser A">A Visser</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lin, Mh" uniqKey="Lin M">MH Lin</name>
</author>
<author>
<name sortKey="Mau, Lp" uniqKey="Mau L">LP Mau</name>
</author>
<author>
<name sortKey="Cochran, Dl" uniqKey="Cochran D">DL Cochran</name>
</author>
<author>
<name sortKey="Shieh, Ys" uniqKey="Shieh Y">YS Shieh</name>
</author>
<author>
<name sortKey="Huang, Ph" uniqKey="Huang P">PH Huang</name>
</author>
<author>
<name sortKey="Huang, Ry" uniqKey="Huang R">RY Huang</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Grauer, D" uniqKey="Grauer D">D Grauer</name>
</author>
<author>
<name sortKey="Cevidanes, Ls" uniqKey="Cevidanes L">LS Cevidanes</name>
</author>
<author>
<name sortKey="Proffit, Wr" uniqKey="Proffit W">WR Proffit</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Fourie, Z" uniqKey="Fourie Z">Z Fourie</name>
</author>
<author>
<name sortKey="Damstra, J" uniqKey="Damstra J">J Damstra</name>
</author>
<author>
<name sortKey="Schepers, Rh" uniqKey="Schepers R">RH Schepers</name>
</author>
<author>
<name sortKey="Gerrits, Po" uniqKey="Gerrits P">PO Gerrits</name>
</author>
<author>
<name sortKey="Ren, Y" uniqKey="Ren Y">Y Ren</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Alqerban, A" uniqKey="Alqerban A">A Alqerban</name>
</author>
<author>
<name sortKey="Jacobs, R" uniqKey="Jacobs R">R Jacobs</name>
</author>
<author>
<name sortKey="Fieuws, S" uniqKey="Fieuws S">S Fieuws</name>
</author>
<author>
<name sortKey="Nackaerts, O" uniqKey="Nackaerts O">O Nackaerts</name>
</author>
<author>
<name sortKey="Willems, G" uniqKey="Willems G">G Willems</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hassan, B" uniqKey="Hassan B">B Hassan</name>
</author>
<author>
<name sortKey="Metska, Me" uniqKey="Metska M">ME Metska</name>
</author>
<author>
<name sortKey="Ozok, Ar" uniqKey="Ozok A">AR Ozok</name>
</author>
<author>
<name sortKey="Van Der Stelt, P" uniqKey="Van Der Stelt P">P van der Stelt</name>
</author>
<author>
<name sortKey="Wesselink, Pr" uniqKey="Wesselink P">PR Wesselink</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Maret, D" uniqKey="Maret D">D Maret</name>
</author>
<author>
<name sortKey="Telmon, N" uniqKey="Telmon N">N Telmon</name>
</author>
<author>
<name sortKey="Peters, Oa" uniqKey="Peters O">OA Peters</name>
</author>
<author>
<name sortKey="Lepage, B" uniqKey="Lepage B">B Lepage</name>
</author>
<author>
<name sortKey="Treil, J" uniqKey="Treil J">J Treil</name>
</author>
<author>
<name sortKey="Inglese, Jm" uniqKey="Inglese J">JM Inglese</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Spin Neto, R" uniqKey="Spin Neto R">R Spin-Neto</name>
</author>
<author>
<name sortKey="Gotfredsen, E" uniqKey="Gotfredsen E">E Gotfredsen</name>
</author>
<author>
<name sortKey="Wenzel, A" uniqKey="Wenzel A">A Wenzel</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Zhang, Y" uniqKey="Zhang Y">Y Zhang</name>
</author>
<author>
<name sortKey="Zhang, L" uniqKey="Zhang L">L Zhang</name>
</author>
<author>
<name sortKey="Zhu, Xr" uniqKey="Zhu X">XR Zhu</name>
</author>
<author>
<name sortKey="Lee, Ak" uniqKey="Lee A">AK Lee</name>
</author>
<author>
<name sortKey="Chambers, M" uniqKey="Chambers M">M Chambers</name>
</author>
<author>
<name sortKey="Dong, L" uniqKey="Dong L">L Dong</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kovacs, M" uniqKey="Kovacs M">M Kovacs</name>
</author>
<author>
<name sortKey="Fejerdy, P" uniqKey="Fejerdy P">P Fejerdy</name>
</author>
<author>
<name sortKey="Dobo, Nc" uniqKey="Dobo N">NC Dobo</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sheikhi, M" uniqKey="Sheikhi M">M Sheikhi</name>
</author>
<author>
<name sortKey="Ghorbanizadeh, S" uniqKey="Ghorbanizadeh S">S Ghorbanizadeh</name>
</author>
<author>
<name sortKey="Abdinian, M" uniqKey="Abdinian M">M Abdinian</name>
</author>
<author>
<name sortKey="Goroohi, H" uniqKey="Goroohi H">H Goroohi</name>
</author>
<author>
<name sortKey="Badrian, H" uniqKey="Badrian H">H Badrian</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Parsa, A" uniqKey="Parsa A">A Parsa</name>
</author>
<author>
<name sortKey="Ibrahim, N" uniqKey="Ibrahim N">N Ibrahim</name>
</author>
<author>
<name sortKey="Hassan, B" uniqKey="Hassan B">B Hassan</name>
</author>
<author>
<name sortKey="Syriopoulos, K" uniqKey="Syriopoulos K">K Syriopoulos</name>
</author>
<author>
<name sortKey="Van Der Stelt, P" uniqKey="Van Der Stelt P">P van der Stelt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Weissheimer, A" uniqKey="Weissheimer A">A Weissheimer</name>
</author>
<author>
<name sortKey="Menezes, Lm" uniqKey="Menezes L">LM Menezes</name>
</author>
<author>
<name sortKey="Sameshima, Gt" uniqKey="Sameshima G">GT Sameshima</name>
</author>
<author>
<name sortKey="Enciso, R" uniqKey="Enciso R">R Enciso</name>
</author>
<author>
<name sortKey="Pham, J" uniqKey="Pham J">J Pham</name>
</author>
<author>
<name sortKey="Grauer, D" uniqKey="Grauer D">D Grauer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lee, H" uniqKey="Lee H">H Lee</name>
</author>
<author>
<name sortKey="Xing, L" uniqKey="Xing L">L Xing</name>
</author>
<author>
<name sortKey="Lee, R" uniqKey="Lee R">R Lee</name>
</author>
<author>
<name sortKey="Fahimian, Bp" uniqKey="Fahimian B">BP Fahimian</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Engelbrecht, Wp" uniqKey="Engelbrecht W">WP Engelbrecht</name>
</author>
<author>
<name sortKey="Fourie, Z" uniqKey="Fourie Z">Z Fourie</name>
</author>
<author>
<name sortKey="Damstra, J" uniqKey="Damstra J">J Damstra</name>
</author>
<author>
<name sortKey="Gerrits, Po" uniqKey="Gerrits P">PO Gerrits</name>
</author>
<author>
<name sortKey="Ren, Y" uniqKey="Ren Y">Y Ren</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Vallaeys, K" uniqKey="Vallaeys K">K Vallaeys</name>
</author>
<author>
<name sortKey="Kacem, A" uniqKey="Kacem A">A Kacem</name>
</author>
<author>
<name sortKey="Legoux, H" uniqKey="Legoux H">H Legoux</name>
</author>
<author>
<name sortKey="Le Tenier, M" uniqKey="Le Tenier M">M Le Tenier</name>
</author>
<author>
<name sortKey="Hamitouche, C" uniqKey="Hamitouche C">C Hamitouche</name>
</author>
<author>
<name sortKey="Arbab Chirani, R" uniqKey="Arbab Chirani R">R Arbab-Chirani</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jin, Jy" uniqKey="Jin J">JY Jin</name>
</author>
<author>
<name sortKey="Ren, L" uniqKey="Ren L">L Ren</name>
</author>
<author>
<name sortKey="Liu, Q" uniqKey="Liu Q">Q Liu</name>
</author>
<author>
<name sortKey="Kim, J" uniqKey="Kim J">J Kim</name>
</author>
<author>
<name sortKey="Wen, N" uniqKey="Wen N">N Wen</name>
</author>
<author>
<name sortKey="Guan, H" uniqKey="Guan H">H Guan</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Moshiri, M" uniqKey="Moshiri M">M Moshiri</name>
</author>
<author>
<name sortKey="Scarfe, Wc" uniqKey="Scarfe W">WC Scarfe</name>
</author>
<author>
<name sortKey="Hilgers, Ml" uniqKey="Hilgers M">ML Hilgers</name>
</author>
<author>
<name sortKey="Scheetz, Jp" uniqKey="Scheetz J">JP Scheetz</name>
</author>
<author>
<name sortKey="Silveira, Am" uniqKey="Silveira A">AM Silveira</name>
</author>
<author>
<name sortKey="Farman, Ag" uniqKey="Farman A">AG Farman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Brown, Aa" uniqKey="Brown A">AA Brown</name>
</author>
<author>
<name sortKey="Scarfe, Wc" uniqKey="Scarfe W">WC Scarfe</name>
</author>
<author>
<name sortKey="Scheetz, Jp" uniqKey="Scheetz J">JP Scheetz</name>
</author>
<author>
<name sortKey="Silveira, Am" uniqKey="Silveira A">AM Silveira</name>
</author>
<author>
<name sortKey="Farman, Ag" uniqKey="Farman A">AG Farman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Fourie, Z" uniqKey="Fourie Z">Z Fourie</name>
</author>
<author>
<name sortKey="Damstra, J" uniqKey="Damstra J">J Damstra</name>
</author>
<author>
<name sortKey="Gerrits, Po" uniqKey="Gerrits P">PO Gerrits</name>
</author>
<author>
<name sortKey="Ren, Y" uniqKey="Ren Y">Y Ren</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Damstra, J" uniqKey="Damstra J">J Damstra</name>
</author>
<author>
<name sortKey="Fourie, Z" uniqKey="Fourie Z">Z Fourie</name>
</author>
<author>
<name sortKey="Huddleston Slater, Jj" uniqKey="Huddleston Slater J">JJ Huddleston Slater</name>
</author>
<author>
<name sortKey="Ren, Y" uniqKey="Ren Y">Y Ren</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Yushkevich, Pa" uniqKey="Yushkevich P">PA Yushkevich</name>
</author>
<author>
<name sortKey="Piven, J" uniqKey="Piven J">J Piven</name>
</author>
<author>
<name sortKey="Hazlett, Hc" uniqKey="Hazlett H">HC Hazlett</name>
</author>
<author>
<name sortKey="Smith, Rg" uniqKey="Smith R">RG Smith</name>
</author>
<author>
<name sortKey="Ho, S" uniqKey="Ho S">S Ho</name>
</author>
<author>
<name sortKey="Gee, Jc" uniqKey="Gee J">JC Gee</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Swennen, Gr" uniqKey="Swennen G">GR Swennen</name>
</author>
<author>
<name sortKey="Mollemans, W" uniqKey="Mollemans W">W Mollemans</name>
</author>
<author>
<name sortKey="Schutyser, F" uniqKey="Schutyser F">F Schutyser</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Nada, Rm" uniqKey="Nada R">RM Nada</name>
</author>
<author>
<name sortKey="Maal, Tj" uniqKey="Maal T">TJ Maal</name>
</author>
<author>
<name sortKey="Breuning, Kh" uniqKey="Breuning K">KH Breuning</name>
</author>
<author>
<name sortKey="Berge, Sj" uniqKey="Berge S">SJ Berge</name>
</author>
<author>
<name sortKey="Mostafa, Ya" uniqKey="Mostafa Y">YA Mostafa</name>
</author>
<author>
<name sortKey="Kuijpers Jagtman, Am" uniqKey="Kuijpers Jagtman A">AM Kuijpers-Jagtman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jayaratne, Ys" uniqKey="Jayaratne Y">YS Jayaratne</name>
</author>
<author>
<name sortKey="Mcgrath, Cp" uniqKey="Mcgrath C">CP McGrath</name>
</author>
<author>
<name sortKey="Zwahlen, Ra" uniqKey="Zwahlen R">RA Zwahlen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Utermohle, Cj" uniqKey="Utermohle C">CJ Utermohle</name>
</author>
<author>
<name sortKey="Zegura, Sl" uniqKey="Zegura S">SL Zegura</name>
</author>
<author>
<name sortKey="Heathcote, Gm" uniqKey="Heathcote G">GM Heathcote</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Congalton, Rg" uniqKey="Congalton R">RG Congalton</name>
</author>
<author>
<name sortKey="Green, K" uniqKey="Green K">K Green</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Olszewski, R" uniqKey="Olszewski R">R Olszewski</name>
</author>
<author>
<name sortKey="Tanesy, O" uniqKey="Tanesy O">O Tanesy</name>
</author>
<author>
<name sortKey="Cosnard, G" uniqKey="Cosnard G">G Cosnard</name>
</author>
<author>
<name sortKey="Zech, F" uniqKey="Zech F">F Zech</name>
</author>
<author>
<name sortKey="Reychler, H" uniqKey="Reychler H">H Reychler</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Medelnik, J" uniqKey="Medelnik J">J Medelnik</name>
</author>
<author>
<name sortKey="Hertrich, K" uniqKey="Hertrich K">K Hertrich</name>
</author>
<author>
<name sortKey="Steinhauser Andresen, S" uniqKey="Steinhauser Andresen S">S Steinhauser-Andresen</name>
</author>
<author>
<name sortKey="Hirschfelder, U" uniqKey="Hirschfelder U">U Hirschfelder</name>
</author>
<author>
<name sortKey="Hofmann, E" uniqKey="Hofmann E">E Hofmann</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Titiz, I" uniqKey="Titiz I">I Titiz</name>
</author>
<author>
<name sortKey="Laubinger, M" uniqKey="Laubinger M">M Laubinger</name>
</author>
<author>
<name sortKey="Keller, T" uniqKey="Keller T">T Keller</name>
</author>
<author>
<name sortKey="Hertrich, K" uniqKey="Hertrich K">K Hertrich</name>
</author>
<author>
<name sortKey="Hirschfelder, U" uniqKey="Hirschfelder U">U Hirschfelder</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Torres, Mg" uniqKey="Torres M">MG Torres</name>
</author>
<author>
<name sortKey="Campos, Ps" uniqKey="Campos P">PS Campos</name>
</author>
<author>
<name sortKey="Segundo, Np" uniqKey="Segundo N">NP Segundo</name>
</author>
<author>
<name sortKey="Navarro, M" uniqKey="Navarro M">M Navarro</name>
</author>
<author>
<name sortKey="Crusoe Rebello, I" uniqKey="Crusoe Rebello I">I Crusoe-Rebello</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Marmulla, R" uniqKey="Marmulla R">R Marmulla</name>
</author>
<author>
<name sortKey="Wortche, R" uniqKey="Wortche R">R Wortche</name>
</author>
<author>
<name sortKey="Muhling, J" uniqKey="Muhling J">J Muhling</name>
</author>
<author>
<name sortKey="Hassfeld, S" uniqKey="Hassfeld S">S Hassfeld</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Cevidanes, Lh" uniqKey="Cevidanes L">LH Cevidanes</name>
</author>
<author>
<name sortKey="Heymann, G" uniqKey="Heymann G">G Heymann</name>
</author>
<author>
<name sortKey="Cornelis, Ma" uniqKey="Cornelis M">MA Cornelis</name>
</author>
<author>
<name sortKey="Declerck, Hj" uniqKey="Declerck H">HJ DeClerck</name>
</author>
<author>
<name sortKey="Tulloch, Jf" uniqKey="Tulloch J">JF Tulloch</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rossini, G" uniqKey="Rossini G">G Rossini</name>
</author>
<author>
<name sortKey="Cavallini, C" uniqKey="Cavallini C">C Cavallini</name>
</author>
<author>
<name sortKey="Cassetta, M" uniqKey="Cassetta M">M Cassetta</name>
</author>
<author>
<name sortKey="Barbato, E" uniqKey="Barbato E">E Barbato</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lindsten, R" uniqKey="Lindsten R">R Lindsten</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Maret, D" uniqKey="Maret D">D Maret</name>
</author>
<author>
<name sortKey="Peters, Oa" uniqKey="Peters O">OA Peters</name>
</author>
<author>
<name sortKey="Galibourg, A" uniqKey="Galibourg A">A Galibourg</name>
</author>
<author>
<name sortKey="Dumoncel, J" uniqKey="Dumoncel J">J Dumoncel</name>
</author>
<author>
<name sortKey="Esclassan, R" uniqKey="Esclassan R">R Esclassan</name>
</author>
<author>
<name sortKey="Kahn, Jl" uniqKey="Kahn J">JL Kahn</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tomasi, C" uniqKey="Tomasi C">C Tomasi</name>
</author>
<author>
<name sortKey="Bressan, E" uniqKey="Bressan E">E Bressan</name>
</author>
<author>
<name sortKey="Corazza, B" uniqKey="Corazza B">B Corazza</name>
</author>
<author>
<name sortKey="Mazzoleni, S" uniqKey="Mazzoleni S">S Mazzoleni</name>
</author>
<author>
<name sortKey="Stellini, E" uniqKey="Stellini E">E Stellini</name>
</author>
<author>
<name sortKey="Lith, A" uniqKey="Lith A">A Lith</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="El Beialy, Ar" uniqKey="El Beialy A">AR El-Beialy</name>
</author>
<author>
<name sortKey="Fayed, Ms" uniqKey="Fayed M">MS Fayed</name>
</author>
<author>
<name sortKey="El Bialy, Am" uniqKey="El Bialy A">AM El-Bialy</name>
</author>
<author>
<name sortKey="Mostafa, Ya" uniqKey="Mostafa Y">YA Mostafa</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Frongia, G" uniqKey="Frongia G">G Frongia</name>
</author>
<author>
<name sortKey="Piancino, Mg" uniqKey="Piancino M">MG Piancino</name>
</author>
<author>
<name sortKey="Bracco, P" uniqKey="Bracco P">P Bracco</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Periago, Dr" uniqKey="Periago D">DR Periago</name>
</author>
<author>
<name sortKey="Scarfe, Wc" uniqKey="Scarfe W">WC Scarfe</name>
</author>
<author>
<name sortKey="Moshiri, M" uniqKey="Moshiri M">M Moshiri</name>
</author>
<author>
<name sortKey="Scheetz, Jp" uniqKey="Scheetz J">JP Scheetz</name>
</author>
<author>
<name sortKey="Silveira, Am" uniqKey="Silveira A">AM Silveira</name>
</author>
<author>
<name sortKey="Farman, Ag" uniqKey="Farman A">AG Farman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Van Haaren, Eh" uniqKey="Van Haaren E">EH van Haaren</name>
</author>
<author>
<name sortKey="Van Der Zwaard, Bc" uniqKey="Van Der Zwaard B">BC van der Zwaard</name>
</author>
<author>
<name sortKey="Van Der Veen, Aj" uniqKey="Van Der Veen A">AJ van der Veen</name>
</author>
<author>
<name sortKey="Heyligers, Ic" uniqKey="Heyligers I">IC Heyligers</name>
</author>
<author>
<name sortKey="Wuisman, Pi" uniqKey="Wuisman P">PI Wuisman</name>
</author>
<author>
<name sortKey="Smit, Th" uniqKey="Smit T">TH Smit</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Clin Oral Investig</journal-id>
<journal-id journal-id-type="iso-abbrev">Clin Oral Investig</journal-id>
<journal-title-group>
<journal-title>Clinical Oral Investigations</journal-title>
</journal-title-group>
<issn pub-type="ppub">1432-6981</issn>
<issn pub-type="epub">1436-3771</issn>
<publisher>
<publisher-name>Springer Berlin Heidelberg</publisher-name>
<publisher-loc>Berlin/Heidelberg</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">27206862</article-id>
<article-id pub-id-type="pmc">5360826</article-id>
<article-id pub-id-type="publisher-id">1844</article-id>
<article-id pub-id-type="doi">10.1007/s00784-016-1844-x</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Dusseldorp</surname>
<given-names>J. K.</given-names>
</name>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Stamatakis</surname>
<given-names>H. C.</given-names>
</name>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Ren</surname>
<given-names>Y.</given-names>
</name>
<address>
<email>y.ren@umcg.nl</email>
</address>
<xref ref-type="aff" rid="Aff1"></xref>
</contrib>
<aff id="Aff1">Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, UMCG, 9700 RB Groningen, The Netherlands</aff>
</contrib-group>
<pub-date pub-type="epub">
<day>21</day>
<month>5</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="pmc-release">
<day>21</day>
<month>5</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="ppub">
<year>2017</year>
</pub-date>
<volume>21</volume>
<issue>3</issue>
<fpage>921</fpage>
<lpage>930</lpage>
<history>
<date date-type="received">
<day>6</day>
<month>10</month>
<year>2015</year>
</date>
<date date-type="accepted">
<day>2</day>
<month>5</month>
<year>2016</year>
</date>
</history>
<permissions>
<copyright-statement>© The Author(s) 2016</copyright-statement>
<license license-type="OpenAccess">
<license-p>
<bold>Open Access</bold>
This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.</license-p>
</license>
</permissions>
<abstract id="Abs1">
<sec>
<title>Objectives</title>
<p>The aim of this study is to investigate the effect of soft tissue presence on the segmentation accuracy of the 3D hard tissue models from cone-beam computed tomography (CBCT).</p>
</sec>
<sec>
<title>Materials and methods</title>
<p>Seven pairs of CBCT Digital Imaging and Communication in Medicine (DICOM) datasets, containing data of human cadaver heads and their respective dry skulls, were used. The effect of the soft tissue presence on the accuracy of the segmented models was evaluated by performing linear and angular measurements and by superimposition and color mapping of the surface discrepancies after splitting the mandible and maxillo-facial complex in the midsagittal plane.</p>
</sec>
<sec>
<title>Results</title>
<p>The linear and angular measurements showed significant differences for the more posterior transversal measurements on the mandible (
<italic>p</italic>
 < 0.01). By splitting and superimposing the maxillo-facial complex, the mean root-mean-square error (RMSE) as a measurement of inaccuracy decreased insignificantly from 0.936 to 0.922 mm (
<italic>p</italic>
 > 0.05). The RMSE value for the mandible, however, significantly decreased from 1.240 to 0.981 mm after splitting (
<italic>p</italic>
 < 0.01).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>The soft tissue presence seems to affect the accuracy of the 3D hard tissue model obtained from a cone-beam CT, below a generally accepted level of clinical significance of 1 mm. However, this level of accuracy may not meet the requirement for applications where high precision is paramount.</p>
</sec>
<sec>
<title>Clinical relevance</title>
<p>Accuracy of CBCT-based 3D surface-rendered models, especially of the hard tissues, are crucial in several dental and medical applications, such as implant planning and virtual surgical planning on patients undergoing orthognathic and navigational surgeries. When used in applications where high precision is paramount, the effect of soft tissue presence should be taken into consideration during the segmentation process.</p>
</sec>
</abstract>
<kwd-group xml:lang="en">
<title>Keywords</title>
<kwd>Cone-beam computed tomography</kwd>
<kwd>Segmentation</kwd>
<kwd>Accuracy</kwd>
<kwd>Surface models</kwd>
<kwd>Soft tissues</kwd>
</kwd-group>
<custom-meta-group>
<custom-meta>
<meta-name>issue-copyright-statement</meta-name>
<meta-value>© Springer-Verlag Berlin Heidelberg 2017</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec id="Sec1" sec-type="introduction">
<title>Introduction</title>
<p>Low-dose cone-beam computed tomography (CBCT) for three-dimensional (3D) imaging of the maxillo-facial structures is increasingly used in the latest years in the medical and dental field, and it extends to a wide range of applications [
<xref ref-type="bibr" rid="CR1">1</xref>
<xref ref-type="bibr" rid="CR3">3</xref>
]. Accurate visualization of the face, jaws, and its components are important for clinical diagnostics and decision-making [
<xref ref-type="bibr" rid="CR4">4</xref>
]. Nowadays, the application of 3D cephalometric analysis plays an important role in cases of complex maxillo-facial abnormalities [
<xref ref-type="bibr" rid="CR5">5</xref>
,
<xref ref-type="bibr" rid="CR6">6</xref>
] and for the evaluation of growth or treatment outcomes [
<xref ref-type="bibr" rid="CR7">7</xref>
<xref ref-type="bibr" rid="CR9">9</xref>
]. Accurate 3D surface-rendered models, especially of the hard tissues, are crucial in applications such as virtual surgical planning on patients undergoing orthognathic surgery, during dental implant and prosthetic procedures, and when simulating treatment outcomes [
<xref ref-type="bibr" rid="CR10">10</xref>
<xref ref-type="bibr" rid="CR15">15</xref>
].</p>
<p>Surface-rendered 3D models of the hard tissues derived from the CBCT Digital Imaging and Communication in Medicine (DICOM) data that are originally composed of voxels, each with its own gray value based on the radiation absorbed by the tissues during the scan. By means of specific software applications, reconstructions are possible in sagittal, coronal, and axial planes, allowing the operator to scroll through the tissue structures in any direction of interest. Most applications also include reconstruction techniques allowing image extraction out of the DICOM data similar to those from conventional radiographic techniques, such as orthopantomograms and lateral cephalometric radiographs [
<xref ref-type="bibr" rid="CR16">16</xref>
]. In order to construct a 3D digital model of specific tissues out of the original voxel-based data, a specific process called segmentation has to be followed. Briefly, the operator provides the software an upper and a lower threshold matching the gray-level range of the voxels which specifies the tissues of interest. The software then discards all data outside these limits and depicts only the voxels within the set threshold values.</p>
<p>Factors influencing the quality and accuracy of the models provided by the segmentation process can be divided in three main categories [
<xref ref-type="bibr" rid="CR17">17</xref>
]. The first comprises CBCT system factors, such as scanner type, field of view settings, and voxel size settings [
<xref ref-type="bibr" rid="CR18">18</xref>
<xref ref-type="bibr" rid="CR21">21</xref>
]. The second category is patient-related factors such as positioning of the patient in the scanner, metal artifacts, and the soft tissue covering [
<xref ref-type="bibr" rid="CR22">22</xref>
<xref ref-type="bibr" rid="CR25">25</xref>
]. The third are operator-related factors, such as the segmentation process itself, the employed software, and the operator performing the segmentation [
<xref ref-type="bibr" rid="CR26">26</xref>
<xref ref-type="bibr" rid="CR29">29</xref>
]. Most studies published on this particular subject were based on research using dry skulls.</p>
<p>The use of the dry skull without any soft tissue substitute may present a drawback, as it does not simulate the human anatomy in real life. The soft tissues are sources of scattering radiation during a radiographic examination, resulting in deterioration of the signal-to-noise ratio and, subsequently, of the gray-level value differentiation in voxels between different density tissues, presumably resulting to lower bone image quality [
<xref ref-type="bibr" rid="CR30">30</xref>
]. As a result, measurements obtained from images on a human dry skull may deviate from the “true” values if they be obtained from the same subjects with soft tissue coverage. Interpretation of these results may be misleading for decision-making in clinical practice. To overcome this error, some studies introduced latex balloons filled with water as a soft tissue equivalent [
<xref ref-type="bibr" rid="CR31">31</xref>
,
<xref ref-type="bibr" rid="CR32">32</xref>
]. One of the drawbacks of this method is that it does not reflect the soft tissue properties or distributions in real life. Alternatively, human cadavers may represent better the human anatomy, which are, however, difficult to obtain. The effect of soft tissue presence on the segmentation process and the resulting 3D surface-rendered volumetric models is not yet well documented, specifically when all the above-mentioned affecting side parameters are standardized.</p>
<p>Therefore, the aim of this study is to investigate whether the soft tissue presence affects the segmentation accuracy of the 3D surface-rendered volumetric models from cone-beam CT in a setting in which other affecting parameters were controlled.</p>
</sec>
<sec id="Sec2" sec-type="materials|methods">
<title>Materials and methods</title>
<sec id="Sec3">
<title>CBCT Data acquisition</title>
<p>A sample of seven DICOM datasets was used for this study, containing the scans of seven anonymous cadaver heads comprising both edentulous and partially edentulous jaws that were initially scanned with the KaVo 3D exam scanner (KaVo Dental GmbH, Bismarckring, Germany) using a standardized scanning protocol [
<xref ref-type="bibr" rid="CR28">28</xref>
]. Subsequently, the cadavers were meticulously macerated according to an established protocol by the Department of Anatomy, University Medical Centre Groningen, Groningen, The Netherlands [
<xref ref-type="bibr" rid="CR33">33</xref>
]. This procedure resulted in the respective seven dry skulls that were scanned with the same scanner and following the original protocol as used during the cadaver scans. The dry skulls were repositioned in the scanner using the laser reference lines of the unit [
<xref ref-type="bibr" rid="CR34">34</xref>
]. Yaw, pitch, roll, and height settings were obtained from the first series of cadaver scans by means of the manufacturer’s software in order to achieve similar positioning. For both sets of scans, a 0.3-mm voxel size with a 17-cm field of view was used. Therewith the complete sample used in this study consists of DICOM datasets of two groups, scans of the cadaver heads with soft tissue, and scans of the respective dry skulls without soft tissue.</p>
</sec>
<sec id="Sec4">
<title>The segmentation protocol</title>
<p>The DICOM datasets were exported from the unit’s dedicated software and imported into ITK-SNAP, a specialized segmentation software package for medical imaging [
<xref ref-type="bibr" rid="CR35">35</xref>
]. The procedure starts with determining the region of interest and threshold levels, followed by setting the seeding points in the tissues of interest, which results in a very close approximation of the 3D structures with neighboring intensities. The final 3D surface-rendered model of the bone surface is formed by segmenting using the level-set method to drive the active contour evolution as coded in the ITK-SNAP software [
<xref ref-type="bibr" rid="CR35">35</xref>
]. It is based on region competition causing the active contour to reach equilibrium at the boundary of the regions, i.e., the borders of the hard tissues, subsequently discarding pixels representing the surrounding soft tissues. The segmentation procedure for the DICOM datasets was performed in a random order following a segmentation protocol fitting the software package. This procedure is partly operator dependent, since each cadaver and dry skull requires an individual set of segmenting thresholds. All segmentations were performed by one operator and repeatedly three times with a 1-week interval to determine intraobserver reliability. This segmentation procedure resulted in digital 3D surface-rendered hard tissue models for both groups, with and without the presence of soft tissues.</p>
</sec>
<sec id="Sec5">
<title>Measuring procedure</title>
<p>The effect of soft tissue on the 3D surface-rendered hard tissue models was analyzed by comparing the two groups of models. The models representing the dry skulls were set as the reference
<xref ref-type="bibr" rid="CR3">3</xref>
D models, against which the models deriving from the cadavers with the soft tissues were tested. Two different methods were employed for comparisons. The first method was based on linear and angular measurements using the Simplant O&O software (Materialise Dental, Leuven, Belgium). A series of landmarks were selected and identified on the 3D digital models, and subsequently, the defined linear and angular measurements were performed by the software [
<xref ref-type="bibr" rid="CR32">32</xref>
,
<xref ref-type="bibr" rid="CR33">33</xref>
,
<xref ref-type="bibr" rid="CR36">36</xref>
]. These measurements are illustrated in Figs.
<xref rid="Fig1" ref-type="fig">1</xref>
and
<xref rid="Fig2" ref-type="fig">2</xref>
for the maxillo-facial complex and the mandible, respectively, and were assessed three-dimensionally on the surface-rendered models. The landmark identifications were performed blindly and in random order by one operator, three times repeatedly with a 1-week interval to test for intraobserver reliability. The second method was based on volume superimposition and color mapping of the surface differences, which are described in the following session in detail [
<xref ref-type="bibr" rid="CR37">37</xref>
,
<xref ref-type="bibr" rid="CR38">38</xref>
].
<fig id="Fig1">
<label>Fig. 1</label>
<caption>
<p>Linear and angular measurements on the maxillo-facial complex.
<italic>1</italic>
,
<italic>2</italic>
orbita width L (left) and R (right)—distance between points medio-orbitale and zygomaticofrontal medial suture;
<italic>3</italic>
zygion width—distance between points zygion R and L;
<italic>4</italic>
frontozygomatic width—distance between points zygomaticofrontal medial suture R and L;
<italic>5</italic>
nasal canal width—distance between points lateral piriform aperture R and L;
<italic>6</italic>
nasal width—distance between points medio-orbitale R and L;
<italic>7</italic>
,
<italic>8</italic>
orbita height—distance between point orbitale and the line crossing both supraorbital points;
<italic>9</italic>
nasion–anterior nasal spine height—distance between points nasion and ANS;
<italic>10</italic>
facial divergence angle nasion—angle from zygion R point to nasion point to zygion L point;
<italic>11</italic>
facial divergence angle ANS—angle from zygion R point to ANS point to zygion L point</p>
</caption>
<graphic xlink:href="784_2016_1844_Fig1_HTML" id="MO1"></graphic>
</fig>
<fig id="Fig2">
<label>Fig. 2</label>
<caption>
<p>Linear and angular measurements on the mandible.
<italic>1</italic>
,
<italic>2</italic>
ramus length (Co–Go);
<italic>3</italic>
,
<italic>4</italic>
mandibular body length (Me–Go);
<italic>5</italic>
,
<italic>6</italic>
total mandibular length (Co–Me);
<italic>7</italic>
,
<italic>8</italic>
condyle width (CoLat–CoMed);
<italic>9</italic>
,
<italic>10</italic>
gonial angle (Co–Go–Me);
<italic>11</italic>
mandibular width at condylion (Co R–Co L);
<italic>12</italic>
mandibular width at condylion laterale (CoLat R–CoLat L);
<italic>13</italic>
mandibular width at condylion mediale (CoMed R–CoMed L);
<italic>14</italic>
mandibular width at coronoid process (CP R–CP L);
<italic>15</italic>
mandibular width at gonion (Go R–Go L);
<italic>16</italic>
mandibular width at antegonion (AG R–AG L);
<italic>17</italic>
mandibular width at mentale foramina (Men.for R–Menfor L);
<italic>18</italic>
condylion divergence angle (Co R–Me–Co L);
<italic>19</italic>
condylion laterale divergence angle (CoLat R–Me–CoLat L);
<italic>20</italic>
condyle mediale divergence angle (CoMed R–Me–CoMed L);
<italic>21</italic>
coronoid divergence angle (CP R–Me–CP L);
<italic>22</italic>
gonion divergence angle (Go R–Me–Go L);
<italic>23</italic>
antegonion divergence angle (AG R–Me–AG L)</p>
</caption>
<graphic xlink:href="784_2016_1844_Fig2_HTML" id="MO2"></graphic>
</fig>
</p>
</sec>
<sec id="Sec6">
<title>Superimposition and color mapping</title>
<p>This procedure was performed using Geomagic Studio software package (Geomagic Solutions, USA). First, the two regions of interest were defined, namely the maxillo-facial complex and the mandible. In this study, the maxillo-facial complex was defined as the area including all external facial surfaces below a horizontal plane, passing through the highest point of the orbital rims, parallel to the Frankfurt horizontal, and ventral to a vertical coronal plane which crosses both temporo-zygomatic sutures, excluding the mandible. The second region of interest was the mandible which was compared completely, including all external lingual and facial surfaces.</p>
<p>Before comparing, the models had to be superimposed (Fig.
<xref rid="Fig3" ref-type="fig">3</xref>
). For both regions of interest, an automatic operator-independent matching was followed; the software performs the best-fit matching based on the least squared differences between the models for optimal superimposition. The maxillo-facial complexes were matched on their complete external facial surfaces. The mandibles, however, given the known potential transversal dimensional deformation due to the maceration and drying techniques [
<xref ref-type="bibr" rid="CR39">39</xref>
], were matched on their frontal area defined as all external surfaces of the mandible ventral to a vertical coronal plane passing through both mental foramina (Fig.
<xref rid="Fig3" ref-type="fig">3</xref>
c). In addition, both the maxillo-facial complex and the mandible models were split in their midsagittal planes in order to further minimize any interfering effect of such dimensional deformation and isolate the soft tissue effects. The resulting left and right parts were matched and compared separately (Fig.
<xref rid="Fig3" ref-type="fig">3</xref>
e, f).
<fig id="Fig3">
<label>Fig. 3</label>
<caption>
<p>Registration and volume comparisons of the maxillo-facial complex and the mandible.
<bold>a</bold>
Selection of the defined maxillo-facial complex and automatic registration by the best-match fitting method.
<bold>b</bold>
Volume comparison of the maxillo-facial complex.
<bold>c</bold>
Selection of the defined frontal area of the mandible and automatic registration by the best-match fitting method.
<bold>d</bold>
Volume comparison of the complete mandible.
<bold>e</bold>
Selection of the left mandibular side and automatic registration by the best-match fitting method.
<bold>f</bold>
Volume comparison of the left mandibular side</p>
</caption>
<graphic xlink:href="784_2016_1844_Fig3_HTML" id="MO3"></graphic>
</fig>
</p>
<p>The differences between the models were displayed by means of color mapping of surface deviations and by sampling the models to approximately one million polygons each. In addition, the software provides information for each comparison indicating the magnitude of deviation between the surfaces of the two registered volumes. The signed average of the surface differences presents the absolute mean of the surface differences by simply adding up positive and/or negative distances for all surface polygons. By definition, differences are marked positive when the tested surface lies outside the reference surface and vice versa. The root-mean-square error (RMSE) was used as an absolute measure of model surface deviations, in order to account for positive and negative differences which otherwise could cancel out each other [
<xref ref-type="bibr" rid="CR38">38</xref>
,
<xref ref-type="bibr" rid="CR40">40</xref>
]. In addition, the mean values of the left and right sides were calculated.</p>
</sec>
<sec id="Sec7">
<title>Statistical analysis</title>
<p>The reliability of all linear and angular measurements was expressed by intraclass correlation coefficients (ICC) for absolute agreement based on a two-way random effects analysis of variance (ANOVA) between the three repeated measurements. All variables were positively tested for normality using the Shapiro-Wilk test with all
<italic>p</italic>
values being >0.05. The significance of differences between the measurements performed on both groups and the differences between RMSE values was calculated using the paired sample
<italic>T</italic>
test. The level of clinical significance was set at 0.05. The RMSEs and signed average of differences were calculated for the selected surfaces on each maxillo-facial complex and mandible model. Mean and standard deviations were calculated. All statistical analyses were performed using Statistical Package of Social Sciences (SPSS).</p>
</sec>
</sec>
<sec id="Sec8" sec-type="results">
<title>Results</title>
<sec id="Sec9">
<title>Measurement reliability</title>
<p>No differences between the repeated segmentations were found exceeding the level of 0.3 mm, which was the voxel size (Fig.
<xref rid="Fig4" ref-type="fig">4</xref>
). These values confirm the reliability of the used segmentation protocol as being excellent. The ICCs of the reliability tests on all measurements obtained from both reference and test groups varied within 0.94–1.00 and were accordingly classified as being excellent.
<fig id="Fig4">
<label>Fig. 4</label>
<caption>
<p>An illustration of the segmentation reliability based on color mapping. The segmentation reliability was assessed by superimposing and color mapping two surface models of the same maxillo-facial complex segmented at two different sessions.
<italic>Green color</italic>
represents differences within 0.3 mm which equals the voxel size</p>
</caption>
<graphic xlink:href="784_2016_1844_Fig4_HTML" id="MO4"></graphic>
</fig>
</p>
</sec>
<sec id="Sec10">
<title>Linear and angular measurements on the maxillo-facial complex</title>
<p>The results from the linear measurements performed on the mandible were shown in Table
<xref rid="Tab1" ref-type="table">1</xref>
. The mean differences for all linear measurements on the maxillo-facial complex ranged between −0.41 and −0.78 mm (Table
<xref rid="Tab1" ref-type="table">1</xref>
). The differences between the reference and test groups for the angular measurements were between −0.41° and −0.12°. Both were found statistically non-significant (
<italic>p</italic>
 > 0.05).
<table-wrap id="Tab1">
<label>Table 1</label>
<caption>
<p>Results of the linear and angular measurements on the maxillo-facial complex</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th rowspan="2">#</th>
<th rowspan="2">Measurement</th>
<th rowspan="2">Unit</th>
<th colspan="2">Group with soft tissue</th>
<th colspan="2">Group without soft tissue</th>
<th colspan="2">Comparison</th>
</tr>
<tr>
<th>Mean</th>
<th>SD</th>
<th>Mean</th>
<th>SD</th>
<th>Δ</th>
<th>95 % CI</th>
</tr>
</thead>
<tbody>
<tr>
<td></td>
<td colspan="8">Linear</td>
</tr>
<tr>
<td>1</td>
<td>Orbita width L</td>
<td>mm</td>
<td>44.76</td>
<td>2.84</td>
<td>44.87</td>
<td>2.82</td>
<td>−0.25</td>
<td>−1.83–1.31</td>
</tr>
<tr>
<td>2</td>
<td>Orbita width R</td>
<td>mm</td>
<td>45.72</td>
<td>2.54</td>
<td>45.59</td>
<td>2.87</td>
<td>0.08</td>
<td>−0.76–0.91</td>
</tr>
<tr>
<td>3</td>
<td>Zygion width</td>
<td>mm</td>
<td>131.38</td>
<td>6.95</td>
<td>131.28</td>
<td>6.93</td>
<td>0.10</td>
<td>−0.59–0.78</td>
</tr>
<tr>
<td>4</td>
<td>Frontozygomatic width</td>
<td>mm</td>
<td>98.01</td>
<td>5.65</td>
<td>97.58</td>
<td>5.67</td>
<td>0.11</td>
<td>−0.08–0.32</td>
</tr>
<tr>
<td>5</td>
<td>Nasal canal width</td>
<td>mm</td>
<td>25.19</td>
<td>2.77</td>
<td>24.44</td>
<td>2.40</td>
<td>0.74</td>
<td>−0.34–1.82</td>
</tr>
<tr>
<td>6</td>
<td>Nasal width</td>
<td>mm</td>
<td>12.18</td>
<td>2.69</td>
<td>11.80</td>
<td>2.43</td>
<td>0.38</td>
<td>−0.99–1.75</td>
</tr>
<tr>
<td>7</td>
<td>Orbita height R</td>
<td>mm</td>
<td>38.83</td>
<td>1.62</td>
<td>38.66</td>
<td>1.54</td>
<td>0.17</td>
<td>−1.25–1.58</td>
</tr>
<tr>
<td>8</td>
<td>Orbita height L</td>
<td>mm</td>
<td>38.79</td>
<td>1.91</td>
<td>38.00</td>
<td>2.16</td>
<td>0.78</td>
<td>−0.48–2.04</td>
</tr>
<tr>
<td>9</td>
<td>Nasion–anterior nasal spine height</td>
<td>mm</td>
<td>53.95</td>
<td>2.93</td>
<td>54.32</td>
<td>3.12</td>
<td>−0.36</td>
<td>−0.77–0.04</td>
</tr>
<tr>
<td></td>
<td colspan="8">Angular</td>
</tr>
<tr>
<td>10</td>
<td>Facial divergence angle nasion</td>
<td>°</td>
<td>88.49</td>
<td>3.65</td>
<td>88.61</td>
<td>3.27</td>
<td>−0.12</td>
<td>−1.99–1.76</td>
</tr>
<tr>
<td>11</td>
<td>Facial divergence angle ANS</td>
<td>°</td>
<td>86.72</td>
<td>2.57</td>
<td>87.13</td>
<td>2.13</td>
<td>−0.41</td>
<td>−2.18–1.35</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>Mean values. Standard deviations (SD). Average differences (Δ) with confidence intervals (CI) at 95 % and level of significance of the differences (P)</p>
</table-wrap-foot>
</table-wrap>
</p>
</sec>
<sec id="Sec11">
<title>Linear and angular measurements on the mandible</title>
<p>The results from the linear measurements performed on the mandible were shown in Table
<xref rid="Tab2" ref-type="table">2</xref>
. Significant differences were found for the mandibular width at the coronoid process (1.95 mm,
<italic>p</italic>
 < 0.01), at condylion laterale (1.42 mm,
<italic>p</italic>
 < 0.01) and at condylion medial (3.60 mm,
<italic>p</italic>
 < 0.001). The angular measurements showed significant differences for the coronoid divergence angle (1.67°,
<italic>p</italic>
 < 0.001), the condyle lateral divergence angle (1.22°,
<italic>p</italic>
 < 0.01), and the condyle medial divergence angle (1.85°,
<italic>p</italic>
 < 0.001).
<table-wrap id="Tab2">
<label>Table 2</label>
<caption>
<p>Results of the linear and angular measurements on the mandible</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th rowspan="2">#</th>
<th rowspan="2">Measurement</th>
<th rowspan="2">Unit</th>
<th colspan="2">Group with soft tissue</th>
<th colspan="2">Group without soft tissue</th>
<th colspan="2">Comparison</th>
</tr>
<tr>
<th>Mean</th>
<th>SD</th>
<th>Mean</th>
<th>SD</th>
<th>Δ</th>
<th>95 % CI</th>
</tr>
</thead>
<tbody>
<tr>
<td></td>
<td colspan="8">Unilateral</td>
</tr>
<tr>
<td></td>
<td colspan="8"> Linear</td>
</tr>
<tr>
<td>1</td>
<td>  Ramus length L</td>
<td>mm</td>
<td>58.50</td>
<td>4.79</td>
<td>59.95</td>
<td>4.28</td>
<td>−1.45</td>
<td>−3.27–0.37</td>
</tr>
<tr>
<td>2</td>
<td>  Ramus length R</td>
<td>mm</td>
<td>59.43</td>
<td>5.44</td>
<td>59.69</td>
<td>4.01</td>
<td>−0.26</td>
<td>−2.19–1.68</td>
</tr>
<tr>
<td>3</td>
<td>  Mandibular body length L</td>
<td>mm</td>
<td>86.80</td>
<td>6.35</td>
<td>86.62</td>
<td>5.54</td>
<td>0.18</td>
<td>−1.23–1.58</td>
</tr>
<tr>
<td>4</td>
<td>  Mandibular body length R</td>
<td>mm</td>
<td>87.50</td>
<td>4.89</td>
<td>87.50</td>
<td>5.24</td>
<td>−0.00</td>
<td>−1.22–1.22</td>
</tr>
<tr>
<td>5</td>
<td>  Total mandibular length L</td>
<td>mm</td>
<td>124.01</td>
<td>7.03</td>
<td>125.49</td>
<td>7.35</td>
<td>−1.48</td>
<td>−2.80–−0.15</td>
</tr>
<tr>
<td>6</td>
<td>  Total mandibular length R</td>
<td>mm</td>
<td>124.47</td>
<td>6.88</td>
<td>124.62</td>
<td>6.96</td>
<td>−0.15</td>
<td>−2.68–2.38</td>
</tr>
<tr>
<td>7</td>
<td>  Condyle width L</td>
<td>mm</td>
<td>20.05</td>
<td>2.38</td>
<td>20.68</td>
<td>2.93</td>
<td>−0.63</td>
<td>−1.70–0.43</td>
</tr>
<tr>
<td>8</td>
<td>  Condyle width R</td>
<td>mm</td>
<td>20.88</td>
<td>2.50</td>
<td>21.88</td>
<td>2.59</td>
<td>−1.00</td>
<td>−2.31–0.31</td>
</tr>
<tr>
<td></td>
<td colspan="8"> Angular</td>
</tr>
<tr>
<td>9</td>
<td>  Gonial angle L</td>
<td>°</td>
<td>115.83</td>
<td>3.65</td>
<td>116.63</td>
<td>4.02</td>
<td>−0.80</td>
<td>−1.88–0.29</td>
</tr>
<tr>
<td>10</td>
<td>  Gonial angle R</td>
<td>°</td>
<td>114.40</td>
<td>4.30</td>
<td>114.38</td>
<td>3.50</td>
<td>0.02</td>
<td>−2.10–2.14</td>
</tr>
<tr>
<td></td>
<td colspan="8">Bilateral</td>
</tr>
<tr>
<td></td>
<td colspan="8"> Linear</td>
</tr>
<tr>
<td>11</td>
<td>  Mandibular width at condylion</td>
<td>mm</td>
<td>103.73</td>
<td>9.10</td>
<td>103.32</td>
<td>6.42</td>
<td>0.41</td>
<td>−3.58–4.41</td>
</tr>
<tr>
<td>12</td>
<td>  Mandibular width at condylion laterale</td>
<td>mm</td>
<td>123.36</td>
<td>6.18</td>
<td>121.95</td>
<td>5.63</td>
<td>1.42**</td>
<td>0.60–2.23</td>
</tr>
<tr>
<td>13</td>
<td>  Mandibular width at condylion mediale</td>
<td>mm</td>
<td>85.87</td>
<td>3.44</td>
<td>82.28</td>
<td>2.60</td>
<td>3.60***</td>
<td>2.70–4.50</td>
</tr>
<tr>
<td>14</td>
<td>  Mandibular width at coronoid process</td>
<td>mm</td>
<td>98.20</td>
<td>7.64</td>
<td>96.24</td>
<td>7.00</td>
<td>1.95**</td>
<td>1.16–2.74</td>
</tr>
<tr>
<td>15</td>
<td>  Mandibular width at gonion</td>
<td>mm</td>
<td>97.41</td>
<td>5.99</td>
<td>96.29</td>
<td>5.64</td>
<td>1.12</td>
<td>−0.29–2.54</td>
</tr>
<tr>
<td>16</td>
<td>  Mandibular width at antegonion</td>
<td>mm</td>
<td>84.75</td>
<td>5.38</td>
<td>83.90</td>
<td>4.57</td>
<td>0.86</td>
<td>−1.28–2.99</td>
</tr>
<tr>
<td>17</td>
<td>  Mandibular width at mentale foramina</td>
<td>mm</td>
<td>47.14</td>
<td>4.91</td>
<td>46.06</td>
<td>3.04</td>
<td>1.08</td>
<td>−1.72–3.89</td>
</tr>
<tr>
<td></td>
<td colspan="8"> Angular</td>
</tr>
<tr>
<td>18</td>
<td>  Condylion divergence angle</td>
<td>°</td>
<td>49.44</td>
<td>4.53</td>
<td>48.85</td>
<td>2.68</td>
<td>0.59</td>
<td>−1.55–2.73</td>
</tr>
<tr>
<td>19</td>
<td>  Condyle laterale divergence angle</td>
<td>°</td>
<td>60.80</td>
<td>2.07</td>
<td>59.58</td>
<td>1.66</td>
<td>1.22**</td>
<td>0.64–1.79</td>
</tr>
<tr>
<td>20</td>
<td>  Condyle mediale divergence angle</td>
<td>°</td>
<td>41.95</td>
<td>1.70</td>
<td>40.10</td>
<td>1.82</td>
<td>1.85***</td>
<td>1.32–2.38</td>
</tr>
<tr>
<td>21</td>
<td>  Coronoid divergence angle</td>
<td>°</td>
<td>55.59</td>
<td>2.44</td>
<td>53.92</td>
<td>2.11</td>
<td>1.67***</td>
<td>1.15–2.19</td>
</tr>
<tr>
<td>22</td>
<td>  Gonion divergence angle</td>
<td>°</td>
<td>68.10</td>
<td>4.02</td>
<td>67.29</td>
<td>4.32</td>
<td>0.80</td>
<td>−0.55–2.15</td>
</tr>
<tr>
<td>23</td>
<td>  Antegonion divergence angle</td>
<td>°</td>
<td>78.90</td>
<td>3.69</td>
<td>78.32</td>
<td>3.79</td>
<td>0.58</td>
<td>−0.21–1.36</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>Mean values. Standard deviations (SD). Average differences (Δ) with confidence intervals (CI) at 95 % and level of significance of the differences (P)</p>
<p>*
<italic>p</italic>
 < 0.05, **
<italic>p</italic>
 < 0.01, ***
<italic>p</italic>
 < 0.001</p>
</table-wrap-foot>
</table-wrap>
</p>
</sec>
<sec id="Sec12">
<title>Volume comparisons of the maxillo-facial complex</title>
<p>The results of the volume superimposition and surface comparisons of the maxillo-facial complex between the reference and test models were shown in Table
<xref rid="Tab3" ref-type="table">3</xref>
. The mean RMSE was 0.936 mm with a standard deviation of 0.188 mm comparing the complete maxillo-facial complexes. The mean signed average of difference between surfaces was −0.092 mm with all values being negative. Dividing the maxillo-facial complex to a left and right side for separate registration and comparing procedures decreased the mean RMSE to 0.922 mm with a standard deviation of 0.195 mm which was not significant (
<italic>p</italic>
 > 0.05).
<table-wrap id="Tab3">
<label>Table 3</label>
<caption>
<p>Results of the volume comparisons of the maxillo-facial complex</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th rowspan="2"></th>
<th colspan="2">Registration: best fit on the complete external facial surfaces of the maxillo-facial complexes</th>
<th colspan="2">Registration: best fit on the concerning left or right side</th>
</tr>
<tr>
<th>Signed average of difference between surfaces (mm)</th>
<th>RMSE of difference between surfaces (mm)</th>
<th>Signed average of differences between surfaces (mm)</th>
<th>Mean RMSE values of differences between surfaces (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>1</td>
<td>−0.058</td>
<td>0.582</td>
<td>−0.045</td>
<td>0.539</td>
</tr>
<tr>
<td>2</td>
<td>−0.078</td>
<td>1.084</td>
<td>−0.077</td>
<td>1.071</td>
</tr>
<tr>
<td>3</td>
<td>−0.021</td>
<td>1.064</td>
<td>−0.020</td>
<td>1.043</td>
</tr>
<tr>
<td>4</td>
<td>−0.197</td>
<td>1.089</td>
<td>−0.197</td>
<td>1.075</td>
</tr>
<tr>
<td>5</td>
<td>−0.027</td>
<td>0.886</td>
<td>−0.018</td>
<td>0.872</td>
</tr>
<tr>
<td>6</td>
<td>−0.103</td>
<td>0.817</td>
<td>−0.119</td>
<td>0.828</td>
</tr>
<tr>
<td>7</td>
<td>−0.162</td>
<td>1.030</td>
<td>−0.167</td>
<td>1.026</td>
</tr>
<tr>
<td>Mean</td>
<td>−0.092</td>
<td>0.936</td>
<td>−0.092</td>
<td>0.922</td>
</tr>
<tr>
<td>SD</td>
<td>0.066</td>
<td>0.188</td>
<td>0.071</td>
<td>0.195</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>Surface differences indicating inaccuracy of 3D digital segmented models, derived from CBCT, caused by the presence of soft tissue</p>
</table-wrap-foot>
</table-wrap>
</p>
</sec>
<sec id="Sec13">
<title>Volume comparisons of the mandible</title>
<p>The results of the mandible comparisons were shown in Table
<xref rid="Tab4" ref-type="table">4</xref>
. Analyzing the complete mandibles registered on the frontal area resulted in a mean RMSE of 1.240 mm with a standard deviation of 0.375 mm. The mean signed average of difference between surfaces was −0.189 mm with all values being negative. Dividing the mandible in a left and right side, for separate registration and comparing procedures, significantly decreased the mean RMSE to 0.981 mm with a standard deviation of 0.411 mm (
<italic>p</italic>
 < 0.01).
<table-wrap id="Tab4">
<label>Table 4</label>
<caption>
<p>Results of the volume comparisons of the mandible</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th rowspan="2"></th>
<th colspan="2">Registration: best fit on symphysis surfaces</th>
<th colspan="2">Registration: best fit on the concerning left or right side</th>
</tr>
<tr>
<th>Signed average of difference between surfaces (mm)</th>
<th>RMSE of difference between surfaces (mm)</th>
<th>Signed average of differences between surfaces (mm)</th>
<th>Mean RMSE values of differences between surfaces (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>1</td>
<td>−0.077</td>
<td>0.879</td>
<td>−0.052</td>
<td>0.503</td>
</tr>
<tr>
<td>2</td>
<td>−0.221</td>
<td>1.422</td>
<td>−0.214</td>
<td>1.073</td>
</tr>
<tr>
<td>3</td>
<td>−0.290</td>
<td>1.886</td>
<td>−0.273</td>
<td>1.640</td>
</tr>
<tr>
<td>4</td>
<td>−0.164</td>
<td>0.956</td>
<td>−0.123</td>
<td>0.798</td>
</tr>
<tr>
<td>5</td>
<td>−0.181</td>
<td>1.118</td>
<td>−0.121</td>
<td>0.694</td>
</tr>
<tr>
<td>6</td>
<td>−0.056</td>
<td>0.921</td>
<td>−0.032</td>
<td>0.758</td>
</tr>
<tr>
<td>7</td>
<td>−0.333</td>
<td>1.496</td>
<td>−0.271</td>
<td>1.401</td>
</tr>
<tr>
<td>Mean</td>
<td>−0.189</td>
<td>1.240</td>
<td>−0.155</td>
<td>0.981</td>
</tr>
<tr>
<td>SD</td>
<td>0.102</td>
<td>0.375</td>
<td>0.099</td>
<td>0.411</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>Surface differences indicating inaccuracy of 3D digital segmented models, derived from CBCT, caused by the presence of soft tissue</p>
</table-wrap-foot>
</table-wrap>
</p>
</sec>
</sec>
<sec id="Sec14" sec-type="discussion">
<title>Discussion</title>
<p>The aim of this study was to investigate whether the soft tissue covering affects the segmentation accuracy of the 3D surface-rendered volumetric models derived from cone-beam CT, which to our knowledge has not been studied previously. Well-defined linear and angular measurements combined with volume comparisons demonstrated as an accurate tool to measure differences between 3D digital models were used as a method to illustrate the soft tissue effect [
<xref ref-type="bibr" rid="CR41">41</xref>
<xref ref-type="bibr" rid="CR43">43</xref>
]. Our results indicate that the soft tissue presence seems to affect the accuracy of the 3D hard tissue model of both the maxillo-facial complex and the mandible obtained from a cone-beam CT, however, below a generally accepted level of clinical significance of 1 mm [
<xref ref-type="bibr" rid="CR44">44</xref>
]. It must nevertheless be noted that this level of accuracy may not meet the requirements of all applications, especially where higher precision is paramount [
<xref ref-type="bibr" rid="CR45">45</xref>
,
<xref ref-type="bibr" rid="CR46">46</xref>
].</p>
<p>All segmentations, linear and angular measurements, and volume comparison procedures were performed repeatedly by one single operator. The repeatability of the segmentation process was found excellent with the differences between repeated segmentations below the set voxel size of 0.3 mm. The ICCs of the linear and angular measurements were classified as “excellent” which is in agreement with previous studies reporting excellent reliability of this method within and among different observers [
<xref ref-type="bibr" rid="CR43">43</xref>
,
<xref ref-type="bibr" rid="CR47">47</xref>
]. The differences of the linear and angular measurements for the maxillo-facial complex were below 1 mm. In the mandible, larger differences were observed which could have possibly demonstrated a considerable effect of soft tissue on the inaccuracy of the models. However, carefully analyzing these results and taking into consideration the maceration and drying process involved in this study, such a conclusion might be found misleading. Previous studies showed an effect of drying on bone morphology particularly concerning a mandible. The posterior transversal dimension of the pig mandibles were affected up to an extent of 2.7 % [
<xref ref-type="bibr" rid="CR48">48</xref>
]. This is in agreement with the present study, in which both the linear and angular measurements and the superimpositions showed differences for the mandibular transversal measurements. Although comparing the maxillo-facial complexes did not reveal such dimensional distortion as seen in the mandible, we could not presume that this region was not affected. In order to minimize any effect of the possible transversal deformation due to the maceration and drying process involved, the mandible and the maxillo-facial complex models were split in their midsagittal planes and the left and right parts were registered and compared separately. The characteristic measure of the inaccuracy of a tested model compared to the reference is the root-mean-square error or RMSE that serves as a measure of how far is the average error from 0, i.e., the distance difference, between the surfaces of the two models. Whereas the mean RMSE values of the maxillo-facial complex barely differ before and after the splitting, that of the mandible significantly decreased to less than 1 mm, which is generally considered as a clinical acceptable threshold [
<xref ref-type="bibr" rid="CR44">44</xref>
]. Further, all mean differences between the surfaces were negative values. This shows a trend in which the dry skull models lie slightly within the cadaver models when the two models were optimally superimposed, indicating the dry skull models being smaller in general which could be caused by a change in humidity [
<xref ref-type="bibr" rid="CR39">39</xref>
]. Although this is a consistent finding, the differences never exceeded the limits of the voxel size of 0.3 mm used in this study. These findings confirm the results from previous studies demonstrating that interpretation of research data, in which dry skulls were used, especially concerning the mandible, should be analyzed with the knowledge that significant changes may have taken place in the cranio-facial dimensions [
<xref ref-type="bibr" rid="CR48">48</xref>
].</p>
<p>Special consideration was taken to control the possible affecting parameters, in order to focus on the effect of soft tissue presence in the accuracy of the 3D model, although this would partly limit the external validity of this study. All dry skulls were scanned using the same cone-beam CT unit, with identical scan settings and similar positioning of the skull in the field of view. Given the fact that the voxel size is another affecting parameter, adjusting the setting to a higher scan resolution could compensate the effect of soft tissue presence. Concerning this parameter, it has been indicated that the accuracy of the models appears to be connected to the voxel size [
<xref ref-type="bibr" rid="CR49">49</xref>
], although the differences were small. However, others did not find increased accuracy of linear measurements on segmented surface models decreasing the voxel size from 0.4 to 0.25 mm [
<xref ref-type="bibr" rid="CR34">34</xref>
]. In our study, the voxel size was fixed to 0.3 mm.</p>
<p>Head positioning is also considered as a possible affecting parameter. The accuracy of linear measurements using wires glued on the skull reported no clinically relevant effect [
<xref ref-type="bibr" rid="CR50">50</xref>
]. Head positioning has been shown to be an affecting variable in the accuracy of the 3D cephalometric measurements based on 3D CBCT surface images and the reliability of linear measurements in some studies [
<xref ref-type="bibr" rid="CR50">50</xref>
<xref ref-type="bibr" rid="CR52">52</xref>
] and to be an insignificant factor for measurement accuracy in others [
<xref ref-type="bibr" rid="CR19">19</xref>
]. Since the range of positioning deviations for error-free measurements are not yet known, we specifically aimed at achieving similar positioning using the laser reference lines of the unit to control the positioning as a parameter affecting the accuracy.</p>
<p>Two other parameters assumed to have a possible effect on the segmentation accuracy are the operator performing the segmentation process and the software utilized. The software package employed requires the operator to define individual hard tissue threshold values for each skull and cadaver. A previous study showed that a commercial software company produced more accurate surface models compared to an experienced 3D clinician [
<xref ref-type="bibr" rid="CR33">33</xref>
]. This higher accuracy could be the result of a more experienced operator performing the segmentation or ascribed to the use of different tools and methods provided by different software packages. Both these affecting factors were well controlled in this study by utilizing one operator with a high intraobserver reliability performing segmentations on both the cadaver and dry skull and the use of one professional software package.</p>
<p>This study used a limited but unique sample of paired CBCT DICOM datasets from seven human cadaver heads and their respective dry skulls, contributing to a method in which the surface models with and without a natural soft tissue coverage could be compared. The effect of the scattering radiation due to the presence of soft tissues, resulting in deterioration of the signal-to-noise ratio and subsequently of the gray-level value differentiation in voxels, was well simulated. The method has a clear advantage over the use of artificial media, such as water balloons, to mimic the coverage of soft tissues [
<xref ref-type="bibr" rid="CR32">32</xref>
,
<xref ref-type="bibr" rid="CR53">53</xref>
]. However, it has to be acknowledged that this method still contains a number of limitations. The preservation and storage of the cadavers was done in formaldehyde embalming fluid which could have increased the soft tissue thickness, altered the bone properties of the cadaver heads, and subsequently influenced the scattering radiation during the radiographic examination [
<xref ref-type="bibr" rid="CR54">54</xref>
]. Therefore, in this study, the cadaver heads were not meant for representing the exact human anatomy of a living being. For the purpose of the present study, they were merely used as ex vivo equivalent of human heads to investigate the effect of soft tissue coverage.</p>
<p>Further research should focus on other affecting parameters resulting in a 3D surface-rendered model including the hardware, software, and operator-dependent parameters. By adjusting and improving these parameters, the effect of soft tissue presence should be minimized resulting in more accurate 3D surface-rendered models suitable for high-accuracy demanding applications.</p>
</sec>
<sec id="Sec15" sec-type="conclusion">
<title>Conclusion</title>
<p>Considering the inherent limitations of any method involving preparation of dry skulls, it seems that the soft tissue presence does affect the segmentation accuracy of the 3D hard tissue model of both the maxillo-facial complex and the mandible obtained from a cone-beam CT, however, below a generally accepted level of clinical significance of 1 mm. As this level of accuracy may not meet the requirements of applications where high precision is paramount, further studies should investigate how to optimize the setting parameters to overcome the potential inaccuracy of CBCT-derived surface models related to the presence of soft tissue.</p>
</sec>
</body>
<back>
<notes notes-type="COI-statement">
<title>Compliance with ethical standards</title>
<sec id="FPar1">
<title>Conflict of interest</title>
<p>The authors declare that they have no competing interests.</p>
</sec>
<sec id="FPar2">
<title>Funding</title>
<p>None.</p>
</sec>
<sec id="FPar3">
<title>Ethical approval</title>
<p>The manuscript does not contain clinical studies or patient data.</p>
</sec>
<sec id="FPar4">
<title>Informed consent</title>
<p>Not required.</p>
</sec>
</notes>
<ref-list id="Bib1">
<title>References</title>
<ref id="CR1">
<label>1.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kaeppler</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>Applications of cone beam computed tomography in dental and oral medicine</article-title>
<source>Int J Comput Dent</source>
<year>2010</year>
<volume>13</volume>
<fpage>203</fpage>
<lpage>219</lpage>
<pub-id pub-id-type="pmid">20879460</pub-id>
</element-citation>
</ref>
<ref id="CR2">
<label>2.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>de Waard</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Rangel</surname>
<given-names>FA</given-names>
</name>
<name>
<surname>Fudalej</surname>
<given-names>PS</given-names>
</name>
<name>
<surname>Bronkhorst</surname>
<given-names>EM</given-names>
</name>
<name>
<surname>Kuijpers-Jagtman</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Breuning</surname>
<given-names>KH</given-names>
</name>
</person-group>
<article-title>Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2014</year>
<volume>146</volume>
<fpage>328</fpage>
<lpage>336</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2014.05.026</pub-id>
</element-citation>
</ref>
<ref id="CR3">
<label>3.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Paniagua</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Cevidanes</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Walker</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Guo</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Styner</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Clinical application of SPHARM-PDM to quantify temporomandibular joint osteoarthritis</article-title>
<source>Comput Med Imaging Graph</source>
<year>2011</year>
<volume>35</volume>
<fpage>345</fpage>
<lpage>352</lpage>
<pub-id pub-id-type="doi">10.1016/j.compmedimag.2010.11.012</pub-id>
<pub-id pub-id-type="pmid">21185694</pub-id>
</element-citation>
</ref>
<ref id="CR4">
<label>4.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hatcher</surname>
<given-names>DC</given-names>
</name>
</person-group>
<article-title>Operational principles for cone-beam computed tomography</article-title>
<source>J Am Dent Assoc</source>
<year>2010</year>
<volume>141</volume>
<issue>Suppl 3</issue>
<fpage>3S</fpage>
<lpage>6S</lpage>
<pub-id pub-id-type="doi">10.14219/jada.archive.2010.0359</pub-id>
<pub-id pub-id-type="pmid">20884933</pub-id>
</element-citation>
</ref>
<ref id="CR5">
<label>5.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>AlHadidi</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Cevidanes</surname>
<given-names>LH</given-names>
</name>
<name>
<surname>Mol</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Ludlow</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Styner</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Comparison of two methods for quantitative assessment of mandibular asymmetry using cone beam computed tomography image volumes</article-title>
<source>Dentomaxillofac Radiol</source>
<year>2011</year>
<volume>40</volume>
<fpage>351</fpage>
<lpage>357</lpage>
<pub-id pub-id-type="doi">10.1259/dmfr/13993523</pub-id>
<pub-id pub-id-type="pmid">21831974</pub-id>
</element-citation>
</ref>
<ref id="CR6">
<label>6.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Luu</surname>
<given-names>NS</given-names>
</name>
<name>
<surname>Nikolcheva</surname>
<given-names>LG</given-names>
</name>
<name>
<surname>Retrouvey</surname>
<given-names>JM</given-names>
</name>
<name>
<surname>Flores-Mir</surname>
<given-names>C</given-names>
</name>
<name>
<surname>El-Bialy</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Carey</surname>
<given-names>JP</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Linear measurements using virtual study models</article-title>
<source>Angle Orthod</source>
<year>2012</year>
<volume>82</volume>
<fpage>1098</fpage>
<lpage>1106</lpage>
<pub-id pub-id-type="doi">10.2319/110311-681.1</pub-id>
<pub-id pub-id-type="pmid">22530811</pub-id>
</element-citation>
</ref>
<ref id="CR7">
<label>7.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>O’Neil</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Khambay</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Bowman</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Moos</surname>
<given-names>KF</given-names>
</name>
<name>
<surname>Barbenel</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Walker</surname>
<given-names>F</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Validation of a new method for building a three-dimensional physical model of the skull and dentition</article-title>
<source>Br J Oral Maxillofac Surg</source>
<year>2012</year>
<volume>50</volume>
<fpage>49</fpage>
<lpage>54</lpage>
<pub-id pub-id-type="doi">10.1016/j.bjoms.2010.11.009</pub-id>
<pub-id pub-id-type="pmid">21194815</pub-id>
</element-citation>
</ref>
<ref id="CR8">
<label>8.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tucker</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Cevidanes</surname>
<given-names>LH</given-names>
</name>
<name>
<surname>Styner</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Reyes</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Proffit</surname>
<given-names>W</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Comparison of actual surgical outcomes and 3-dimensional surgical simulations</article-title>
<source>J Oral Maxillofac Surg</source>
<year>2010</year>
<volume>68</volume>
<fpage>2412</fpage>
<lpage>2421</lpage>
<pub-id pub-id-type="doi">10.1016/j.joms.2009.09.058</pub-id>
<pub-id pub-id-type="pmid">20591553</pub-id>
</element-citation>
</ref>
<ref id="CR9">
<label>9.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Oh</surname>
<given-names>KM</given-names>
</name>
<name>
<surname>Seo</surname>
<given-names>SK</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>JE</given-names>
</name>
<name>
<surname>Sim</surname>
<given-names>HS</given-names>
</name>
<name>
<surname>Cevidanes</surname>
<given-names>LH</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>YJ</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Post-operative soft tissue changes in patients with mandibular prognathism after bimaxillary surgery</article-title>
<source>J Craniomaxillofac Surg</source>
<year>2013</year>
<volume>41</volume>
<fpage>204</fpage>
<lpage>211</lpage>
<pub-id pub-id-type="doi">10.1016/j.jcms.2012.09.001</pub-id>
<pub-id pub-id-type="pmid">23058178</pub-id>
</element-citation>
</ref>
<ref id="CR10">
<label>10.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Marmulla</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Hoppe</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Muhling</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Eggers</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>An augmented reality system for image-guided surgery</article-title>
<source>Int J Oral Maxillofac Surg</source>
<year>2005</year>
<volume>34</volume>
<fpage>594</fpage>
<lpage>596</lpage>
<pub-id pub-id-type="doi">10.1016/j.ijom.2005.05.004</pub-id>
<pub-id pub-id-type="pmid">16053885</pub-id>
</element-citation>
</ref>
<ref id="CR11">
<label>11.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Swennen</surname>
<given-names>GR</given-names>
</name>
<name>
<surname>Mollemans</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Schutyser</surname>
<given-names>F</given-names>
</name>
</person-group>
<article-title>Three-dimensional treatment planning of orthognathic surgery in the era of virtual imaging</article-title>
<source>J Oral Maxillofac Surg</source>
<year>2009</year>
<volume>67</volume>
<fpage>2080</fpage>
<lpage>2092</lpage>
<pub-id pub-id-type="doi">10.1016/j.joms.2009.06.007</pub-id>
<pub-id pub-id-type="pmid">19761902</pub-id>
</element-citation>
</ref>
<ref id="CR12">
<label>12.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cevidanes</surname>
<given-names>LH</given-names>
</name>
<name>
<surname>Tucker</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Styner</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Chapuis</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Reyes</surname>
<given-names>M</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Three-dimensional surgical simulation</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2010</year>
<volume>138</volume>
<fpage>361</fpage>
<lpage>371</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2009.08.026</pub-id>
</element-citation>
</ref>
<ref id="CR13">
<label>13.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zinser</surname>
<given-names>MJ</given-names>
</name>
<name>
<surname>Mischkowski</surname>
<given-names>RA</given-names>
</name>
<name>
<surname>Sailer</surname>
<given-names>HF</given-names>
</name>
<name>
<surname>Zoller</surname>
<given-names>JE</given-names>
</name>
</person-group>
<article-title>Computer-assisted orthognathic surgery: feasibility study using multiple CAD/CAM surgical splints</article-title>
<source>Oral Surg Oral Med Oral Pathol Oral Radiol</source>
<year>2012</year>
<volume>113</volume>
<fpage>673</fpage>
<lpage>687</lpage>
<pub-id pub-id-type="doi">10.1016/j.oooo.2011.11.009</pub-id>
<pub-id pub-id-type="pmid">22668627</pub-id>
</element-citation>
</ref>
<ref id="CR14">
<label>14.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Van der Meer</surname>
<given-names>WJ</given-names>
</name>
<name>
<surname>Raghoebar</surname>
<given-names>GM</given-names>
</name>
<name>
<surname>Gerrits</surname>
<given-names>PO</given-names>
</name>
<name>
<surname>Noorda</surname>
<given-names>WD</given-names>
</name>
<name>
<surname>Vissink</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Visser</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Digitally designed surgical guides for placing implants in the nasal floor of dentate patients: a series of three cases</article-title>
<source>Int J Prosthodont</source>
<year>2012</year>
<volume>25</volume>
<fpage>245</fpage>
<lpage>251</lpage>
<pub-id pub-id-type="pmid">22545253</pub-id>
</element-citation>
</ref>
<ref id="CR15">
<label>15.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lin</surname>
<given-names>MH</given-names>
</name>
<name>
<surname>Mau</surname>
<given-names>LP</given-names>
</name>
<name>
<surname>Cochran</surname>
<given-names>DL</given-names>
</name>
<name>
<surname>Shieh</surname>
<given-names>YS</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>PH</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>RY</given-names>
</name>
</person-group>
<article-title>Risk assessment of inferior alveolar nerve injury for immediate implant placement in the posterior mandible: a virtual implant placement study</article-title>
<source>J Dent</source>
<year>2014</year>
<volume>42</volume>
<fpage>263</fpage>
<lpage>270</lpage>
<pub-id pub-id-type="doi">10.1016/j.jdent.2013.12.014</pub-id>
<pub-id pub-id-type="pmid">24394585</pub-id>
</element-citation>
</ref>
<ref id="CR16">
<label>16.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Grauer</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Cevidanes</surname>
<given-names>LS</given-names>
</name>
<name>
<surname>Proffit</surname>
<given-names>WR</given-names>
</name>
</person-group>
<article-title>Working with DICOM craniofacial images</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2009</year>
<volume>136</volume>
<fpage>460</fpage>
<lpage>470</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2009.04.016</pub-id>
</element-citation>
</ref>
<ref id="CR17">
<label>17.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fourie</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Damstra</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Schepers</surname>
<given-names>RH</given-names>
</name>
<name>
<surname>Gerrits</surname>
<given-names>PO</given-names>
</name>
<name>
<surname>Ren</surname>
<given-names>Y</given-names>
</name>
</person-group>
<article-title>Segmentation process significantly influences the accuracy of 3D surface models derived from cone beam computed tomography</article-title>
<source>Eur J Radiol</source>
<year>2012</year>
<volume>81</volume>
<fpage>524</fpage>
<lpage>530</lpage>
<pub-id pub-id-type="doi">10.1016/j.ejrad.2011.06.001</pub-id>
</element-citation>
</ref>
<ref id="CR18">
<label>18.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Alqerban</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Jacobs</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Fieuws</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Nackaerts</surname>
<given-names>O</given-names>
</name>
<collab>SEDENTEXCT Project Consortium</collab>
<name>
<surname>Willems</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>Comparison of 6 cone-beam computed tomography systems for image quality and detection of simulated canine impaction-induced external root resorption in maxillary lateral incisors</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2011</year>
<volume>140</volume>
<fpage>129</fpage>
<lpage>139</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2011.03.021</pub-id>
</element-citation>
</ref>
<ref id="CR19">
<label>19.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hassan</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Metska</surname>
<given-names>ME</given-names>
</name>
<name>
<surname>Ozok</surname>
<given-names>AR</given-names>
</name>
<name>
<surname>van der Stelt</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Wesselink</surname>
<given-names>PR</given-names>
</name>
</person-group>
<article-title>Comparison of five cone beam computed tomography systems for the detection of vertical root fractures</article-title>
<source>J Endod</source>
<year>2010</year>
<volume>36</volume>
<fpage>126</fpage>
<lpage>129</lpage>
<pub-id pub-id-type="doi">10.1016/j.joen.2009.09.013</pub-id>
<pub-id pub-id-type="pmid">20003950</pub-id>
</element-citation>
</ref>
<ref id="CR20">
<label>20.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Maret</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Telmon</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Peters</surname>
<given-names>OA</given-names>
</name>
<name>
<surname>Lepage</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Treil</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Inglese</surname>
<given-names>JM</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT</article-title>
<source>Dentomaxillofac Radiol</source>
<year>2012</year>
<volume>41</volume>
<fpage>649</fpage>
<lpage>655</lpage>
<pub-id pub-id-type="doi">10.1259/dmfr/81804525</pub-id>
<pub-id pub-id-type="pmid">23166362</pub-id>
</element-citation>
</ref>
<ref id="CR21">
<label>21.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Spin-Neto</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Gotfredsen</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Wenzel</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Variation in voxel value distribution and effect of time between exposures in six CBCT units</article-title>
<source>Dentomaxillofac Radiol</source>
<year>2014</year>
</element-citation>
</ref>
<ref id="CR22">
<label>22.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>XR</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>AK</given-names>
</name>
<name>
<surname>Chambers</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Dong</surname>
<given-names>L</given-names>
</name>
</person-group>
<article-title>Reducing metal artifacts in cone-beam CT images by preprocessing projection data</article-title>
<source>Int J Radiat Oncol Biol Phys</source>
<year>2007</year>
<volume>67</volume>
<fpage>924</fpage>
<lpage>932</lpage>
<pub-id pub-id-type="doi">10.1016/j.ijrobp.2006.09.045</pub-id>
<pub-id pub-id-type="pmid">17161556</pub-id>
</element-citation>
</ref>
<ref id="CR23">
<label>23.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kovacs</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Fejerdy</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Dobo</surname>
<given-names>NC</given-names>
</name>
</person-group>
<article-title>Metal artefact on head and neck cone-beam CT images</article-title>
<source>Fogorv Sz</source>
<year>2008</year>
<volume>101</volume>
<fpage>171</fpage>
<lpage>178</lpage>
<pub-id pub-id-type="pmid">19039918</pub-id>
</element-citation>
</ref>
<ref id="CR24">
<label>24.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sheikhi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Ghorbanizadeh</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Abdinian</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Goroohi</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Badrian</surname>
<given-names>H</given-names>
</name>
</person-group>
<article-title>Accuracy of linear measurements of galileos cone beam computed tomography in normal and different head positions</article-title>
<source>Int J Dent</source>
<year>2012</year>
<pub-id pub-id-type="pmid">22844282</pub-id>
</element-citation>
</ref>
<ref id="CR25">
<label>25.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Parsa</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Ibrahim</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Hassan</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Syriopoulos</surname>
<given-names>K</given-names>
</name>
<name>
<surname>van der Stelt</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Assessment of metal artefact reduction around dental titanium implants in cone beam CT</article-title>
<source>Dentomaxillofac Radiol.</source>
<year>2014</year>
</element-citation>
</ref>
<ref id="CR26">
<label>26.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Weissheimer</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Menezes</surname>
<given-names>LM</given-names>
</name>
<name>
<surname>Sameshima</surname>
<given-names>GT</given-names>
</name>
<name>
<surname>Enciso</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Pham</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Grauer</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>Imaging software accuracy for 3-dimensional analysis of the upper airway</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2012</year>
<volume>142</volume>
<fpage>801</fpage>
<lpage>813</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2012.07.015</pub-id>
</element-citation>
</ref>
<ref id="CR27">
<label>27.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Xing</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Fahimian</surname>
<given-names>BP</given-names>
</name>
</person-group>
<article-title>Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information</article-title>
<source>Med Phys</source>
<year>2012</year>
<volume>39</volume>
<fpage>2386</fpage>
<lpage>2395</lpage>
<pub-id pub-id-type="doi">10.1118/1.3691901</pub-id>
<pub-id pub-id-type="pmid">22559608</pub-id>
</element-citation>
</ref>
<ref id="CR28">
<label>28.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Engelbrecht</surname>
<given-names>WP</given-names>
</name>
<name>
<surname>Fourie</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Damstra</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Gerrits</surname>
<given-names>PO</given-names>
</name>
<name>
<surname>Ren</surname>
<given-names>Y</given-names>
</name>
</person-group>
<article-title>The influence of the segmentation process on 3D measurements from cone beam computed tomography-derived surface models</article-title>
<source>Clin Oral Investig</source>
<year>2013</year>
<volume>17</volume>
<fpage>1919</fpage>
<lpage>1927</lpage>
<pub-id pub-id-type="doi">10.1007/s00784-012-0881-3</pub-id>
<pub-id pub-id-type="pmid">23371754</pub-id>
</element-citation>
</ref>
<ref id="CR29">
<label>29.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vallaeys</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Kacem</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Legoux</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Le Tenier</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Hamitouche</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Arbab-Chirani</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>3-D dento-maxillary osteolytic lesion and active contour segmentation pilot study in CBCT: semi-automatic vs manual methods</article-title>
<source>Dentomaxillofac Radiol.</source>
<year>2015</year>
<pub-id pub-id-type="pmid">25996572</pub-id>
</element-citation>
</ref>
<ref id="CR30">
<label>30.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jin</surname>
<given-names>JY</given-names>
</name>
<name>
<surname>Ren</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Q</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Wen</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Guan</surname>
<given-names>H</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT)</article-title>
<source>Med Phys</source>
<year>2010</year>
<volume>37</volume>
<fpage>5634</fpage>
<lpage>5644</lpage>
<pub-id pub-id-type="doi">10.1118/1.3497272</pub-id>
<pub-id pub-id-type="pmid">21158275</pub-id>
</element-citation>
</ref>
<ref id="CR31">
<label>31.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Moshiri</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Scarfe</surname>
<given-names>WC</given-names>
</name>
<name>
<surname>Hilgers</surname>
<given-names>ML</given-names>
</name>
<name>
<surname>Scheetz</surname>
<given-names>JP</given-names>
</name>
<name>
<surname>Silveira</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Farman</surname>
<given-names>AG</given-names>
</name>
</person-group>
<article-title>Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2007</year>
<volume>132</volume>
<fpage>550</fpage>
<lpage>560</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2006.09.046</pub-id>
</element-citation>
</ref>
<ref id="CR32">
<label>32.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Brown</surname>
<given-names>AA</given-names>
</name>
<name>
<surname>Scarfe</surname>
<given-names>WC</given-names>
</name>
<name>
<surname>Scheetz</surname>
<given-names>JP</given-names>
</name>
<name>
<surname>Silveira</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Farman</surname>
<given-names>AG</given-names>
</name>
</person-group>
<article-title>Linear accuracy of cone beam CT derived 3D images</article-title>
<source>Angle Orthod</source>
<year>2009</year>
<volume>79</volume>
<fpage>150</fpage>
<lpage>157</lpage>
<pub-id pub-id-type="doi">10.2319/122407-599.1</pub-id>
<pub-id pub-id-type="pmid">19123719</pub-id>
</element-citation>
</ref>
<ref id="CR33">
<label>33.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fourie</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Damstra</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Gerrits</surname>
<given-names>PO</given-names>
</name>
<name>
<surname>Ren</surname>
<given-names>Y</given-names>
</name>
</person-group>
<article-title>Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems</article-title>
<source>Forensic Sci Int</source>
<year>2011</year>
<volume>207</volume>
<fpage>127</fpage>
<lpage>134</lpage>
<pub-id pub-id-type="doi">10.1016/j.forsciint.2010.09.018</pub-id>
<pub-id pub-id-type="pmid">20951517</pub-id>
</element-citation>
</ref>
<ref id="CR34">
<label>34.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Damstra</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Fourie</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Huddleston Slater</surname>
<given-names>JJ</given-names>
</name>
<name>
<surname>Ren</surname>
<given-names>Y</given-names>
</name>
</person-group>
<article-title>Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2010</year>
<volume>137</volume>
<fpage>16e1</fpage>
<lpage>16e6</lpage>
</element-citation>
</ref>
<ref id="CR35">
<label>35.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yushkevich</surname>
<given-names>PA</given-names>
</name>
<name>
<surname>Piven</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Hazlett</surname>
<given-names>HC</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>RG</given-names>
</name>
<name>
<surname>Ho</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Gee</surname>
<given-names>JC</given-names>
</name>
<etal></etal>
</person-group>
<article-title>User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability</article-title>
<source>NeuroImage</source>
<year>2006</year>
<volume>31</volume>
<fpage>1116</fpage>
<lpage>1128</lpage>
<pub-id pub-id-type="doi">10.1016/j.neuroimage.2006.01.015</pub-id>
<pub-id pub-id-type="pmid">16545965</pub-id>
</element-citation>
</ref>
<ref id="CR36">
<label>36.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Swennen</surname>
<given-names>GR</given-names>
</name>
<name>
<surname>Mollemans</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Schutyser</surname>
<given-names>F</given-names>
</name>
</person-group>
<article-title>Three-dimensional treatment planning of orthognathic surgery in the era of virtual imaging</article-title>
<source>J Oral Maxillofac Surg: Off J Am Assoc Oral Maxillofac Surg</source>
<year>2009</year>
<volume>67</volume>
<fpage>2080</fpage>
<lpage>2092</lpage>
<pub-id pub-id-type="doi">10.1016/j.joms.2009.06.007</pub-id>
</element-citation>
</ref>
<ref id="CR37">
<label>37.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nada</surname>
<given-names>RM</given-names>
</name>
<name>
<surname>Maal</surname>
<given-names>TJ</given-names>
</name>
<name>
<surname>Breuning</surname>
<given-names>KH</given-names>
</name>
<name>
<surname>Berge</surname>
<given-names>SJ</given-names>
</name>
<name>
<surname>Mostafa</surname>
<given-names>YA</given-names>
</name>
<name>
<surname>Kuijpers-Jagtman</surname>
<given-names>AM</given-names>
</name>
</person-group>
<article-title>Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches</article-title>
<source>PLoS ONE</source>
<year>2011</year>
</element-citation>
</ref>
<ref id="CR38">
<label>38.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jayaratne</surname>
<given-names>YS</given-names>
</name>
<name>
<surname>McGrath</surname>
<given-names>CP</given-names>
</name>
<name>
<surname>Zwahlen</surname>
<given-names>RA</given-names>
</name>
</person-group>
<article-title>How accurate are the fusion of cone-beam CT and 3-D stereophotographic images?</article-title>
<source>PLoS ONE</source>
<year>2012</year>
</element-citation>
</ref>
<ref id="CR39">
<label>39.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Utermohle</surname>
<given-names>CJ</given-names>
</name>
<name>
<surname>Zegura</surname>
<given-names>SL</given-names>
</name>
<name>
<surname>Heathcote</surname>
<given-names>GM</given-names>
</name>
</person-group>
<article-title>Multiple observers, humidity, and choice of precision statistics: factors influencing craniometric data quality</article-title>
<source>Am J Phys Anthropol</source>
<year>1983</year>
<volume>61</volume>
<fpage>85</fpage>
<lpage>95</lpage>
<pub-id pub-id-type="doi">10.1002/ajpa.1330610109</pub-id>
<pub-id pub-id-type="pmid">6869516</pub-id>
</element-citation>
</ref>
<ref id="CR40">
<label>40.</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Congalton</surname>
<given-names>RG</given-names>
</name>
<name>
<surname>Green</surname>
<given-names>K</given-names>
</name>
</person-group>
<source>Assessing the accuracy of remotely sensed data: principles and practices: second edition</source>
<year>2009</year>
<publisher-loc>Boca Raton</publisher-loc>
<publisher-name>CRC Press, Taylor and Francis Group</publisher-name>
</element-citation>
</ref>
<ref id="CR41">
<label>41.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Olszewski</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Tanesy</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Cosnard</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Zech</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Reychler</surname>
<given-names>H</given-names>
</name>
</person-group>
<article-title>Reproducibility of osseous landmarks used for computed tomography based three-dimensional cephalometric analyses</article-title>
<source>J Craniomaxillofac Surg</source>
<year>2010</year>
<volume>38</volume>
<fpage>214</fpage>
<lpage>221</lpage>
<pub-id pub-id-type="doi">10.1016/j.jcms.2009.05.005</pub-id>
<pub-id pub-id-type="pmid">19574058</pub-id>
</element-citation>
</ref>
<ref id="CR42">
<label>42.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Medelnik</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Hertrich</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Steinhauser-Andresen</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Hirschfelder</surname>
<given-names>U</given-names>
</name>
<name>
<surname>Hofmann</surname>
<given-names>E</given-names>
</name>
</person-group>
<article-title>Accuracy of anatomical landmark identification using different CBCT- and MSCT-based 3D images: an in vitro study</article-title>
<source>J Orofac Orthop</source>
<year>2011</year>
<volume>72</volume>
<fpage>261</fpage>
<lpage>278</lpage>
<pub-id pub-id-type="doi">10.1007/s00056-011-0032-5</pub-id>
<pub-id pub-id-type="pmid">21898195</pub-id>
</element-citation>
</ref>
<ref id="CR43">
<label>43.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Titiz</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Laubinger</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Keller</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Hertrich</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Hirschfelder</surname>
<given-names>U</given-names>
</name>
</person-group>
<article-title>Repeatability and reproducibility of landmarks—a three-dimensional computed tomography study</article-title>
<source>Eur J Orthod</source>
<year>2012</year>
<volume>34</volume>
<fpage>276</fpage>
<lpage>286</lpage>
<pub-id pub-id-type="doi">10.1093/ejo/cjq190</pub-id>
<pub-id pub-id-type="pmid">21566086</pub-id>
</element-citation>
</ref>
<ref id="CR44">
<label>44.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Torres</surname>
<given-names>MG</given-names>
</name>
<name>
<surname>Campos</surname>
<given-names>PS</given-names>
</name>
<name>
<surname>Segundo</surname>
<given-names>NP</given-names>
</name>
<name>
<surname>Navarro</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Crusoe-Rebello</surname>
<given-names>I</given-names>
</name>
</person-group>
<article-title>Accuracy of linear measurements in cone beam computed tomography with different voxel sizes</article-title>
<source>Implant Dent</source>
<year>2012</year>
<volume>21</volume>
<fpage>150</fpage>
<lpage>155</lpage>
<pub-id pub-id-type="doi">10.1097/ID.0b013e31824bf93c</pub-id>
<pub-id pub-id-type="pmid">22382754</pub-id>
</element-citation>
</ref>
<ref id="CR45">
<label>45.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Marmulla</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Wortche</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Muhling</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Hassfeld</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Geometric accuracy of the NewTom 9000 cone beam CT</article-title>
<source>Dentomaxillofac Radiol</source>
<year>2005</year>
<volume>34</volume>
<fpage>28</fpage>
<lpage>31</lpage>
<pub-id pub-id-type="doi">10.1259/dmfr/31342245</pub-id>
<pub-id pub-id-type="pmid">15709102</pub-id>
</element-citation>
</ref>
<ref id="CR46">
<label>46.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cevidanes</surname>
<given-names>LH</given-names>
</name>
<name>
<surname>Heymann</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Cornelis</surname>
<given-names>MA</given-names>
</name>
<name>
<surname>DeClerck</surname>
<given-names>HJ</given-names>
</name>
<name>
<surname>Tulloch</surname>
<given-names>JF</given-names>
</name>
</person-group>
<article-title>Superimposition of 3-dimensional cone-beam computed tomography models of growing patients</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2009</year>
<volume>136</volume>
<fpage>94</fpage>
<lpage>99</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2009.01.018</pub-id>
</element-citation>
</ref>
<ref id="CR47">
<label>47.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rossini</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Cavallini</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Cassetta</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Barbato</surname>
<given-names>E</given-names>
</name>
</person-group>
<article-title>3D cephalometric analysis obtained from computed tomography</article-title>
<source>Rev Lit Ann Stomatol (Roma)</source>
<year>2011</year>
<volume>2</volume>
<fpage>31</fpage>
<lpage>39</lpage>
</element-citation>
</ref>
<ref id="CR48">
<label>48.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lindsten</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>The effect of maceration on the dental arches and the transverse cranial dimensions: a study on the pig</article-title>
<source>Eur J Orthod</source>
<year>2002</year>
<volume>24</volume>
<fpage>667</fpage>
<lpage>676</lpage>
<pub-id pub-id-type="doi">10.1093/ejo/24.6.667</pub-id>
<pub-id pub-id-type="pmid">12512784</pub-id>
</element-citation>
</ref>
<ref id="CR49">
<label>49.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Maret</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Peters</surname>
<given-names>OA</given-names>
</name>
<name>
<surname>Galibourg</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Dumoncel</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Esclassan</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Kahn</surname>
<given-names>JL</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Comparison of the accuracy of 3-dimensional cone-beam computed tomography and micro-computed tomography reconstructions by using different voxel sizes</article-title>
<source>J Endod</source>
<year>2014</year>
<volume>40</volume>
<fpage>1321</fpage>
<lpage>1326</lpage>
<pub-id pub-id-type="doi">10.1016/j.joen.2014.04.014</pub-id>
<pub-id pub-id-type="pmid">25146011</pub-id>
</element-citation>
</ref>
<ref id="CR50">
<label>50.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tomasi</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Bressan</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Corazza</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Mazzoleni</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Stellini</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Lith</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations</article-title>
<source>Dentomaxillofac Radiol</source>
<year>2011</year>
<volume>40</volume>
<fpage>244</fpage>
<lpage>250</lpage>
<pub-id pub-id-type="doi">10.1259/dmfr/17432330</pub-id>
<pub-id pub-id-type="pmid">21493881</pub-id>
</element-citation>
</ref>
<ref id="CR51">
<label>51.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>El-Beialy</surname>
<given-names>AR</given-names>
</name>
<name>
<surname>Fayed</surname>
<given-names>MS</given-names>
</name>
<name>
<surname>El-Bialy</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Mostafa</surname>
<given-names>YA</given-names>
</name>
</person-group>
<article-title>Accuracy and reliability of cone-beam computed tomography measurements: influence of head orientation</article-title>
<source>Am J Orthod Dentofac Orthop</source>
<year>2011</year>
<volume>140</volume>
<fpage>157</fpage>
<lpage>165</lpage>
<pub-id pub-id-type="doi">10.1016/j.ajodo.2010.03.030</pub-id>
</element-citation>
</ref>
<ref id="CR52">
<label>52.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Frongia</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Piancino</surname>
<given-names>MG</given-names>
</name>
<name>
<surname>Bracco</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Cone-beam computed tomography: accuracy of three-dimensional cephalometry analysis and influence of patient scanning position</article-title>
<source>J Craniofac Surg</source>
<year>2012</year>
<volume>23</volume>
<fpage>1038</fpage>
<lpage>1043</lpage>
<pub-id pub-id-type="doi">10.1097/SCS.0b013e318252d5e1</pub-id>
<pub-id pub-id-type="pmid">22777473</pub-id>
</element-citation>
</ref>
<ref id="CR53">
<label>53.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Periago</surname>
<given-names>DR</given-names>
</name>
<name>
<surname>Scarfe</surname>
<given-names>WC</given-names>
</name>
<name>
<surname>Moshiri</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Scheetz</surname>
<given-names>JP</given-names>
</name>
<name>
<surname>Silveira</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Farman</surname>
<given-names>AG</given-names>
</name>
</person-group>
<article-title>Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program</article-title>
<source>Angle Orthod</source>
<year>2008</year>
<volume>78</volume>
<fpage>387</fpage>
<lpage>395</lpage>
<pub-id pub-id-type="doi">10.2319/122106-52.1</pub-id>
<pub-id pub-id-type="pmid">18416632</pub-id>
</element-citation>
</ref>
<ref id="CR54">
<label>54.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>van Haaren</surname>
<given-names>EH</given-names>
</name>
<name>
<surname>van der Zwaard</surname>
<given-names>BC</given-names>
</name>
<name>
<surname>van der Veen</surname>
<given-names>AJ</given-names>
</name>
<name>
<surname>Heyligers</surname>
<given-names>IC</given-names>
</name>
<name>
<surname>Wuisman</surname>
<given-names>PI</given-names>
</name>
<name>
<surname>Smit</surname>
<given-names>TH</given-names>
</name>
</person-group>
<article-title>Effect of long-term preservation on the mechanical properties of cortical bone in goats</article-title>
<source>Acta Orthop</source>
<year>2008</year>
<volume>79</volume>
<fpage>708</fpage>
<lpage>716</lpage>
<pub-id pub-id-type="doi">10.1080/17453670810016759</pub-id>
<pub-id pub-id-type="pmid">18839380</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C27 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000C27 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:5360826
   |texte=   Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:27206862" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022