Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.
***** Acces problem to record *****\

Identifieur interne : 0006900 ( Pmc/Corpus ); précédent : 0006899; suivant : 0006901 ***** probable Xml problem with record *****

Links to Exploration step


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparative evaluation of reproducibility of peripheral tissues produced by different border molding materials in edentulous patients: An
<italic>in vivo</italic>
study</title>
<author>
<name sortKey="Arora, Aman Kumar" sort="Arora, Aman Kumar" uniqKey="Arora A" first="Aman Kumar" last="Arora">Aman Kumar Arora</name>
<affiliation>
<nlm:aff id="aff1">Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Goyal, Itanshu" sort="Goyal, Itanshu" uniqKey="Goyal I" first="Itanshu" last="Goyal">Itanshu Goyal</name>
<affiliation>
<nlm:aff id="aff1">Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Sehgal, Monilka" sort="Sehgal, Monilka" uniqKey="Sehgal M" first="Monilka" last="Sehgal">Monilka Sehgal</name>
<affiliation>
<nlm:aff id="aff1">Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">26929495</idno>
<idno type="pmc">4762307</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4762307</idno>
<idno type="RBID">PMC:4762307</idno>
<idno type="doi">10.4103/0972-4052.155030</idno>
<date when="2015">2015</date>
<idno type="wicri:Area/Pmc/Corpus">000690</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000690</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Comparative evaluation of reproducibility of peripheral tissues produced by different border molding materials in edentulous patients: An
<italic>in vivo</italic>
study</title>
<author>
<name sortKey="Arora, Aman Kumar" sort="Arora, Aman Kumar" uniqKey="Arora A" first="Aman Kumar" last="Arora">Aman Kumar Arora</name>
<affiliation>
<nlm:aff id="aff1">Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Goyal, Itanshu" sort="Goyal, Itanshu" uniqKey="Goyal I" first="Itanshu" last="Goyal">Itanshu Goyal</name>
<affiliation>
<nlm:aff id="aff1">Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Sehgal, Monilka" sort="Sehgal, Monilka" uniqKey="Sehgal M" first="Monilka" last="Sehgal">Monilka Sehgal</name>
<affiliation>
<nlm:aff id="aff1">Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The Journal of the Indian Prosthodontic Society</title>
<idno type="ISSN">0972-4052</idno>
<idno type="eISSN">1998-4057</idno>
<imprint>
<date when="2015">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec id="st1">
<title>Aim:</title>
<p>The aim of the study is to analyze the effect of different materials and techniques in current use on peripheral shaping of complete denture impression.</p>
</sec>
<sec id="st2">
<title>Methods:</title>
<p>The present study was conducted to compare and evaluate the maxillary border morphology produced using tissue conditioner as control and low fusing impression compound, Polyether, Pattern resin and periphery wax as border molding materials. The study was carried out on 15 denture wearer patients with well formed, rounded edentulous maxillary arch with adequate width and height. On each patient, border moldings were done, with tissue conditioner which was loaded on the borders of previous maxillary denture of the patient (control group), low fusing impression compound (Group 1), polyether (Group 2), Pattern resin (Group 3) and Peripheral wax (Group 4), respectively on special tray made for the patient. Sulcus width height and area was then measured for each group using stereomicroscope.</p>
</sec>
<sec id="st3">
<title>Results and Conclusions:</title>
<p>Based on the study it is concluded that the polyether was the best material for border molding which will give most accurate borders to a denture.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Fisher, Rd" uniqKey="Fisher R">RD Fisher</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Klein, Ie" uniqKey="Klein I">IE Klein</name>
</author>
<author>
<name sortKey="Broner, As" uniqKey="Broner A">AS Broner</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Smith, De" uniqKey="Smith D">DE Smith</name>
</author>
<author>
<name sortKey="Toolson, Lb" uniqKey="Toolson L">LB Toolson</name>
</author>
<author>
<name sortKey="Bolender, Cl" uniqKey="Bolender C">CL Bolender</name>
</author>
<author>
<name sortKey="Lord, Jl" uniqKey="Lord J">JL Lord</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jankelson, B" uniqKey="Jankelson B">B Jankelson</name>
</author>
<author>
<name sortKey="Radke, Jc" uniqKey="Radke J">JC Radke</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Abdel Hakim, Am" uniqKey="Abdel Hakim A">AM Abdel-Hakim</name>
</author>
<author>
<name sortKey="Al Dalgan, Sa" uniqKey="Al Dalgan S">SA al-Dalgan</name>
</author>
<author>
<name sortKey="Al Bishre, Gm" uniqKey="Al Bishre G">GM al-Bishre</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bolouri, A" uniqKey="Bolouri A">A Bolouri</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jones, Jd" uniqKey="Jones J">JD Jones</name>
</author>
<author>
<name sortKey="Sobieralski, J" uniqKey="Sobieralski J">J Sobieralski</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kirk, Ga" uniqKey="Kirk G">GA Kirk</name>
</author>
<author>
<name sortKey="Holt, Je" uniqKey="Holt J">JE Holt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Allen, P" uniqKey="Allen P">P Allen</name>
</author>
<author>
<name sortKey="Worrollo, S" uniqKey="Worrollo S">S Worrollo</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Chaffee, Nr" uniqKey="Chaffee N">NR Chaffee</name>
</author>
<author>
<name sortKey="Cooper, Lf" uniqKey="Cooper L">LF Cooper</name>
</author>
<author>
<name sortKey="Felton, Da" uniqKey="Felton D">DA Felton</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Olivieri, A" uniqKey="Olivieri A">A Olivieri</name>
</author>
<author>
<name sortKey="Zuccari, Ag" uniqKey="Zuccari A">AG Zuccari</name>
</author>
<author>
<name sortKey="Olivieri, D" uniqKey="Olivieri D">D Olivieri</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Solomon, Eg" uniqKey="Solomon E">EG Solomon</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mittal, S" uniqKey="Mittal S">S Mittal</name>
</author>
<author>
<name sortKey="Gupta, D" uniqKey="Gupta D">D Gupta</name>
</author>
<author>
<name sortKey="Sharma, H" uniqKey="Sharma H">H Sharma</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kinra, Ms" uniqKey="Kinra M">MS Kinra</name>
</author>
<author>
<name sortKey="Verma, R" uniqKey="Verma R">R Verma</name>
</author>
<author>
<name sortKey="Nagpal, A" uniqKey="Nagpal A">A Nagpal</name>
</author>
<author>
<name sortKey="Verma, Pr" uniqKey="Verma P">PR Verma</name>
</author>
<author>
<name sortKey="Kalra, A" uniqKey="Kalra A">A Kalra</name>
</author>
<author>
<name sortKey="Kinra, M" uniqKey="Kinra M">M Kinra</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Qureshi, I" uniqKey="Qureshi I">I Qureshi</name>
</author>
<author>
<name sortKey="Rashid, S" uniqKey="Rashid S">S Rashid</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mccarthy, Ja" uniqKey="Mccarthy J">JA McCarthy</name>
</author>
<author>
<name sortKey="Moser, Jb" uniqKey="Moser J">JB Moser</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Krysinski, Z" uniqKey="Krysinski Z">Z Krysinski</name>
</author>
<author>
<name sortKey="Prylinski, M" uniqKey="Prylinski M">M Prylinski</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Indian Prosthodont Soc</journal-id>
<journal-id journal-id-type="iso-abbrev">J Indian Prosthodont Soc</journal-id>
<journal-id journal-id-type="publisher-id">JIPS</journal-id>
<journal-title-group>
<journal-title>The Journal of the Indian Prosthodontic Society</journal-title>
</journal-title-group>
<issn pub-type="ppub">0972-4052</issn>
<issn pub-type="epub">1998-4057</issn>
<publisher>
<publisher-name>Medknow Publications & Media Pvt Ltd</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">26929495</article-id>
<article-id pub-id-type="pmc">4762307</article-id>
<article-id pub-id-type="publisher-id">JIPS-15-102</article-id>
<article-id pub-id-type="doi">10.4103/0972-4052.155030</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Comparative evaluation of reproducibility of peripheral tissues produced by different border molding materials in edentulous patients: An
<italic>in vivo</italic>
study</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Arora</surname>
<given-names>Aman Kumar</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
<xref ref-type="corresp" rid="cor1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Goyal</surname>
<given-names>Itanshu</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sehgal</surname>
<given-names>Monilka</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
</contrib>
</contrib-group>
<aff id="aff1">Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India</aff>
<author-notes>
<corresp id="cor1">
<bold>Address for correspondence:</bold>
Dr. Aman Kumar Arora, Department of Prosthodontics, DAV Dental College, Yamuna Nagar, Haryana, India. E-mail:
<email xlink:href="dramanarora1970@gmail.com">dramanarora1970@gmail.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<season>Apr-Jun</season>
<year>2015</year>
</pub-date>
<volume>15</volume>
<issue>2</issue>
<fpage>102</fpage>
<lpage>110</lpage>
<history>
<date date-type="received">
<day>04</day>
<month>7</month>
<year>2014</year>
</date>
<date date-type="accepted">
<day>28</day>
<month>9</month>
<year>2014</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright: © 2015 The Journal of Indian Prosthodontic Society</copyright-statement>
<copyright-year>2015</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc-sa/3.0">
<license-p>This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.</license-p>
</license>
</permissions>
<abstract>
<sec id="st1">
<title>Aim:</title>
<p>The aim of the study is to analyze the effect of different materials and techniques in current use on peripheral shaping of complete denture impression.</p>
</sec>
<sec id="st2">
<title>Methods:</title>
<p>The present study was conducted to compare and evaluate the maxillary border morphology produced using tissue conditioner as control and low fusing impression compound, Polyether, Pattern resin and periphery wax as border molding materials. The study was carried out on 15 denture wearer patients with well formed, rounded edentulous maxillary arch with adequate width and height. On each patient, border moldings were done, with tissue conditioner which was loaded on the borders of previous maxillary denture of the patient (control group), low fusing impression compound (Group 1), polyether (Group 2), Pattern resin (Group 3) and Peripheral wax (Group 4), respectively on special tray made for the patient. Sulcus width height and area was then measured for each group using stereomicroscope.</p>
</sec>
<sec id="st3">
<title>Results and Conclusions:</title>
<p>Based on the study it is concluded that the polyether was the best material for border molding which will give most accurate borders to a denture.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Border molding</kwd>
<kwd>complete dentures</kwd>
<kwd>functional molding</kwd>
<kwd>stereomicroscope</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="sec1-1">
<title>INTRODUCTION</title>
<p>Appropriate peripheral extension and accurate recording of tissue detail in final impression are indispensible to success of complete denture.</p>
<p>Border molding is a process by which the shape of the borders of the tray is made to conform accurately to contours of labial and buccal vestibule. This essential refinement of the tray's fit ensures optimal peripheral seal. It has often been erroneously referred to as muscle trimming. Main objective of border molding is maximal extension and accuracy of peripheral borders with no functional impingement of the tissues. This will create peripheral seal, around denture margins to prevent ingress of air thus providing retention. Fisher,[
<xref rid="ref1" ref-type="bibr">1</xref>
] klein and Broner[
<xref rid="ref2" ref-type="bibr">2</xref>
] all emphasized the need to seal the denture periphery in order to obtain retention.</p>
<p>Border molding an impression tray before securing the final impression is a time honored procedure in complete denture fabrication. Low fusing compound has been made use for border molding impression trays since it was introduced by green brothers in 1907. However, border molding using low fusing impression compound usually requires separate applications of the material to different sections of the tray borders which can be quite messy. Manipulation of the border tissues which demands a great deal of experience and judgment on operators part to conform thermoplastic material to vestibule. Stage by stage or incremental border molding leaves much to be desired since only a part of functional depth of the vestibular sulcus and associated musculature molds to the periphery of the tray during each insertion. Ideally the material should contact the entire vestibular sulcus area at one insertion and not mold the periphery of the tissues initially in one area and subsequently the remaining areas in stages.</p>
<p>Many other materials such as Vinyl polysiloxane; perio pack; light polymerized resin; waxes exist to record the functional and physiologic borders of the denture.</p>
<p>A material which will allow simultaneous moldings of all borders has two general advantages: The number of insertions of the trays for maxillary and mandibular border molding could be reduced to two, a great time and motion advantage. Development of all borders simultaneously avoids propagation of errors caused by a mistake in one section affecting the border contours in another section.</p>
<p>Smith
<italic>et al</italic>
., advocated the use of polyether base impression material for border molding of complete denture impression. With this technique, there is simultaneous border molding of all the borders of impression with a single insertion of the tray.[
<xref rid="ref3" ref-type="bibr">3</xref>
]</p>
<p>The most functional and physiologic border are recorded using materials that would continuously flow for an extended period of time. However among the available materials only tissue conditioner exhibits this property. This would mean that all the border molding should be done using tissue conditioner. However, its use needs denture base or old denture, which is not always available or practically possible in every patient.</p>
<p>Therefore, the need exists to determine which of the available materials for border molding would be most close to accurate recording of border width and height as compared to tissue conditioner.</p>
<p>On similar lines, a study was planned to evaluate the border morphology produced by border molding using four different border molding materials.</p>
</sec>
<sec sec-type="methods" id="sec1-2">
<title>METHODS</title>
<p>A total of 15 edentulous patients of age group between 40 and 70 years were selected in Department of Prosthodontics and Crown and Bridge in DAV Dental College, Yamunanagar. The patients who required/wanted maxillary complete denture were selected for this study. The patients were well-informed about the study, and ethical clearance was obtained. The patients were selected according to:</p>
<sec id="sec2-1">
<title>Inclusion criteria</title>
<p>
<list list-type="bullet">
<list-item>
<p>Well-formed edentulous maxillary arch (well-rounded, adequate width and height)</p>
</list-item>
<list-item>
<p>Patients wearing old maxillary dentures.</p>
</list-item>
</list>
</p>
</sec>
<sec id="sec2-2">
<title>Exclusion criteria</title>
<p>
<list list-type="bullet">
<list-item>
<p>Patients with undercuts</p>
</list-item>
<list-item>
<p>Excessive ridge resorption</p>
</list-item>
<list-item>
<p>Flabby anterior ridge</p>
</list-item>
<list-item>
<p>Papillary hyperplasia</p>
</list-item>
<list-item>
<p>Poor neuromuscular control.</p>
</list-item>
</list>
</p>
</sec>
<sec id="sec2-3">
<title>Selection of maxillary stock tray and primary impression</title>
<p>Primary impression of the maxillary arch was made with impression compound and cast was poured in dental stone which was used to fabricate custom trays.</p>
</sec>
<sec id="sec2-4">
<title>Fabrication of custom trays</title>
<p>Four custom trays on maxillary cast (extending from buccal frenum to buccal frenum) were made with auto polymerizing acrylic resin. 0.5 mm thick spacer wax was adapted 4 mm short of sulcus. Then over the spacer, tin foil was adapted. For achieving uniform thickness of the custom trays, single sheet of base plate wax was adapted over tin foil and flasking was done. After placing flask under the bench press for 45 min, when the plaster was set, dewaxing was done, thus creating a uniform space for the packing of autopolymerizing acrylic resin. Now for fabricating custom tray, spacer wax was adapted, and windows for two tissue stops were made at the region of lateral incisors [
<xref ref-type="fig" rid="F1">Figure 1</xref>
]. Now tin foil was adapted, and autopolymerizing acrylic resin was packed over it. After placing the flask under the bench press for 45 min, tray was retrieved. Similarly, spacer wax and tin foil was adapted, and autopolymerizing acrylic resin was packed for the other three trays. On the cast from the deepest point of sulcus a line 2 mm short of sulcus was marked and taking this line as reference, trays were trimmed and were finished. Tray handle was made. Similarly remaining 3 trays were fabricated and finished [
<xref ref-type="fig" rid="F2">Figure 2</xref>
].</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption>
<p>Flasked primary cast with spacer and tissue stops</p>
</caption>
<graphic xlink:href="JIPS-15-102-g001"></graphic>
</fig>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption>
<p>Four trays with handles for border molding</p>
</caption>
<graphic xlink:href="JIPS-15-102-g002"></graphic>
</fig>
</sec>
<sec id="sec2-5">
<title>Border molding and impression procedures</title>
<p>Labial flange of the existing maxillary denture was trimmed 2 mm short of the sulcus between buccal frenum to buccal frenum. Tissue conditioner (Temporary soft liner; Dentsply) was mixed according to the manufacturer's recommendations and was applied on labial flange. In order to perform functional border molding movements for recording labial vestibule patient was instructed to smile, yawn, whistle, speak “ooo” and “eeee” in regular fashion and then patient was asked to pucker the mouth for 5 s. The patient was instructed to continue regular activities at home with denture and was asked to report after 24 h with functionally molded denture flange [
<xref ref-type="fig" rid="F3">Figure 3</xref>
].</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption>
<p>Functionally molded denture with tissue conditioner from buccal frenum to buccal frenum</p>
</caption>
<graphic xlink:href="JIPS-15-102-g003"></graphic>
</fig>
<p>The cast was poured in die stone (Kalrock; Kalabhai). A total of 15 patients were selected, and 15 casts were obtained which were considered as a control group.</p>
<p>After 24 h on the second visit of the patient, border molding of first tray was done with low fusing impression compound (DPI Pinnacle) in stick form which was fused by dry heat and applied on the borders of the labial flange of the tray. Tray was tempered in the water bath and carried to the patient's mouth for border molding. In order to perform functional border molding movements for recording labial vestibule, patient was instructed to smile, yawn, whistle, speak “ooo” and “eeee” in regular fashion and then patient was asked to pucker the mouth for 5 s. Spacer was removed, and tray adhesive was applied on the tray and wash impression was made with addition silicone (Express XT Light Body; 3M ESPE) [Figures
<xref ref-type="fig" rid="F3">3</xref>
and
<xref ref-type="fig" rid="F4">4</xref>
]. Impressions were beaded and boxed and poured in die stone (Kalrock; Kalabhai). The casts so obtained were considered as Group 1 casts.</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption>
<p>Border molded tray with all four border molded materials and final impression</p>
</caption>
<graphic xlink:href="JIPS-15-102-g004"></graphic>
</fig>
<p>Similarly, border molding was done with Polyether medium bodied consistency (Impregnum, 3M ESPE). Polyether material was mixed and then syringed on the borders of the labial flange of the tray. In order to perform functional border molding movements for recording labial vestibule patient was instructed to smile, yawn, whistle, speak “ooo” and “eeee” in regular fashion and then patient was asked to pucker the mouth for 5 s. Spacer was removed, and tray adhesive was applied on the tray and wash impression was made with addition silicone [
<xref ref-type="fig" rid="F4">Figure 4</xref>
] (Express XT Light Body; 3M ESPE). Impressions were beaded and boxed and poured in die stone (Kalrock; Kalabhai). The casts so obtained were considered as Group 2 casts.</p>
<p>For the third tray, border molding was done using Pattern Resin (GC, Tokyo, Japan). Powder and liquid were mixed according to the manufacturer's instruction and applied on the borders of the tray. In order to perform functional border molding movements for recording labial vestibule, patient was instructed to smile, yawn, whistle, speak “ooo” and “eeee” in regular fashion and then patient was asked to pucker the mouth for 5 s. Spacer was removed, and tray adhesive was applied on the tray and wash impression was made with addition silicone (Express XT Light body; 3M ESPE) [
<xref ref-type="fig" rid="F4">Figure 4</xref>
]. Impressions were beaded and boxed and poured in die stone (Kalrock; Kalabhai). The casts so obtained were considered as Group 3 casts.</p>
<p>For the fourth tray, Periphery Wax (Carmel: Canada) was softened in warm water (54°C) to a consistency which will stick to the tray but will allow easy molding by hand. In order to perform functional border molding movements for recording labial vestibule, patient was instructed to smile, yawn, whistle, speak “ooo” and “eeee” in regular fashion and then patient was asked to pucker the mouth for 5 s. Spacer was removed, and tray adhesive was applied on the tray and wash impression was made with addition silicone (Express XT Light Body; 3M ESPE) [
<xref ref-type="fig" rid="F4">Figure 4</xref>
]. Impressions were beaded and boxed and poured in die stone. The casts so obtained were considered as Group 4 casts.</p>
</sec>
<sec id="sec2-6">
<title>Beading and boxing the impression</title>
<p>The border molded impression trays were put on the bench top, and points were marked 2 mm below from the highest point of border along the periphery with compass. All these points were joined to form a line 2 mm below the border. A beading wax was then placed in the line to achieve 2 mm uniform border width. All the beaded impression were boxed and poured with die stone (Kalrock; Kalabhai).</p>
</sec>
<sec id="sec2-7">
<title>Sectioning the cast and contour measurement</title>
<p>Casts were retrieved, and clear vacuum formed sheet was adapted on the cast. A string was adapted along the crest of the ridge. The entire string length was then measured with the scale and divided in to five equal intervals. The strings with four marks were then placed on the cast and marks were transferred on the cast. Vacuum formed template was placed on top of it [
<xref ref-type="fig" rid="F5">Figure 5</xref>
]. Holes were made on the template according to the markings on the cast. This template with holes at equal intervals was used for transferring marks on other casts on which lines were drawn for sectioning of casts [
<xref ref-type="fig" rid="F6">Figure 6</xref>
]. The casts were sectioned along these lines to obtain five sections of equal dimensions naming them as A, B, C, D, and E, respectively, from left to right [
<xref ref-type="fig" rid="F7">Figure 7</xref>
].</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption>
<p>Marks transferred on vacuum sheet which will be used to transfer marks on other four cast</p>
</caption>
<graphic xlink:href="JIPS-15-102-g005"></graphic>
</fig>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption>
<p>Lines drawn on the cast dividing it into five equal sections (a-e)</p>
</caption>
<graphic xlink:href="JIPS-15-102-g006"></graphic>
</fig>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption>
<p>Five sections</p>
</caption>
<graphic xlink:href="JIPS-15-102-g007"></graphic>
</fig>
<p>Under stereomicroscope (with accuracy of 0.001 mm) height was measured from the horizontal projection of the ledge of ridge to the lowest point of the labial sulcus. Similarly, width was measured from the horizontal projection of the ledge [
<xref ref-type="fig" rid="F8">Figure 8</xref>
]. Each group (control and group 1–4) consisted of 15 patients. For each patient, cast was sectioned into five equidistant sections naming them as A, B, C, D, E. Each section was studied for width and height under stereomicroscope. Mean of all five sections was taken as final reading for that section. Area for a single section was calculated by product of mean of width and height of that section.</p>
<fig id="F8" position="float">
<label>Figure 8</label>
<caption>
<p>Sections under stereomicroscope</p>
</caption>
<graphic xlink:href="JIPS-15-102-g008"></graphic>
</fig>
<p>Total area was measured as the cumulative average of the entire area. The average measurement of the total area of all the five sections was taken as final measurements for the material in those patients. Data collected were tabulated and subjected statistical analysis.</p>
</sec>
</sec>
<sec sec-type="results" id="sec1-3">
<title>RESULTS</title>
<p>After compilations of the data, appropriate statistics were applied. All data were analyzed using the Statistical Package for Social Sciences (SPSS) for Windows, version 15.0 (SPSS Inc., Chicago, USA). The following descriptive statistical analyses were used in the analysis of the present study.</p>
<p>
<list list-type="bullet">
<list-item>
<p>One-way analysis of variance (ANOVA): To test the equality of means (more than two means) of width, height and area ANOVA was used. ANOVA is a general method for studying sampled-data relationships. The purpose is to test for significant differences between class means of width, height and area of sulcus and this is done by analyzing the variances. ANOVA signifies whether difference of values between groups is significant or not. For the significance within groups
<italic>post-hoc</italic>
Bonferroni test was used</p>
</list-item>
<list-item>
<p>
<italic>Post-hoc</italic>
Bonferroni test: A
<italic>post-hoc</italic>
test is conducted after the completion of ANOVA and is done in order to determine whether the differences of mean of width, height and area of sulcus within the four groups are significant or not</p>
</list-item>
<list-item>
<p>Level of significance: “
<italic>P</italic>
” is level of significance:
<italic>P</italic>
>0.05 - not significant
<italic>P</italic>
< 0.05 - significant.</p>
</list-item>
</list>
</p>
<sec id="sec2-8">
<title>Width</title>
<p>The mean width of the sulcus in Group 2 (14.132 ± 2.47 mm) was closest to the control group (14.335 ± 3.28 mm) whereas Group 1 (17.638 ± 2.47 mm) was the farthest [
<xref ref-type="table" rid="T1">Table 1</xref>
and
<xref ref-type="fig" rid="F9">Graph 1</xref>
]. One-way ANOVA analysis showed that mean sulcus width obtained by border molding with four different materials was significant (
<italic>P</italic>
= 0.004) between groups [
<xref ref-type="table" rid="T2">Table 2</xref>
]. Multiple comparisons of different groups when compared with control group using
<italic>post-hoc</italic>
Bonferroni test, shows that the difference of mean of width between Group 1 and control group (3.303 mm) was significant (
<italic>P</italic>
= 0.016). Comparisons with other groups were nonsignificant [
<xref ref-type="table" rid="T3">Table 3</xref>
]. Difference of mean of width of sulcus obtained with low fusing impression compound (Group 1), and polyether (Group 2) (3.506 mm) was significant (
<italic>P</italic>
= 0.009) [
<xref ref-type="table" rid="T4">Table 4</xref>
].</p>
<table-wrap id="T1" position="float">
<label>Table 1</label>
<caption>
<p>Mean of width of sulcus in different groups (mm)</p>
</caption>
<graphic xlink:href="JIPS-15-102-g009"></graphic>
</table-wrap>
<fig id="F9" position="float">
<label>Graph 1</label>
<caption>
<p>Comparing width of sulcus with different border molding materials</p>
</caption>
<graphic xlink:href="JIPS-15-102-g010"></graphic>
</fig>
<table-wrap id="T2" position="float">
<label>Table 2</label>
<caption>
<p>ANOVA</p>
</caption>
<graphic xlink:href="JIPS-15-102-g011"></graphic>
</table-wrap>
<table-wrap id="T3" position="float">
<label>Table 3</label>
<caption>
<p>Multiple comparison of width of sulcus in control group with other four groups using
<italic>post-hoc</italic>
Bonferroni test</p>
</caption>
<graphic xlink:href="JIPS-15-102-g012"></graphic>
</table-wrap>
<table-wrap id="T4" position="float">
<label>Table 4</label>
<caption>
<p>Multiple comparison of width within groups using
<italic>post-hoc</italic>
Bonferroni test</p>
</caption>
<graphic xlink:href="JIPS-15-102-g013"></graphic>
</table-wrap>
</sec>
<sec id="sec2-9">
<title>Height</title>
<p>The mean height of the sulcus in Group 2 (14.702 ± 1.997 mm) was closest to the control group (15.076 ± 1.039 mm) whereas Group 1 (13.651 ± 2.846 mm) was the farthest [
<xref ref-type="table" rid="T5">Table 5</xref>
and
<xref ref-type="fig" rid="F10">Graph 2</xref>
]. One way ANOVA analysis showed that mean sulcus height obtained by border molding with four different materials was significant (
<italic>P</italic>
= 0.000) between groups [
<xref ref-type="table" rid="T6">Table 6</xref>
]. Multiple comparisons of different groups, when compared with the control group using
<italic>post-hoc</italic>
Bonferroni test shows that the difference of mean of height between Group 4 and control group (2.765 mm) was significant (
<italic>P</italic>
= 0.011). Comparisons with other groups were nonsignificant [
<xref ref-type="table" rid="T7">Table 7</xref>
]. The difference of mean of height of sulcus obtained with low fusing impression compound (Group 1) and periphery wax (Group 4) (4.190 mm) was significant (
<italic>P</italic>
= 0.000) and between polyether (Group 2) and periphery wax (Group 4) (3.138 mm) was also significant (
<italic>P</italic>
= 0.003) [
<xref ref-type="table" rid="T8">Table 8</xref>
].</p>
<table-wrap id="T5" position="float">
<label>Table 5</label>
<caption>
<p>Mean of height of sulcus in different groups (mm)</p>
</caption>
<graphic xlink:href="JIPS-15-102-g014"></graphic>
</table-wrap>
<fig id="F10" position="float">
<label>Graph 2</label>
<caption>
<p>Comparing height of sulcus with different border molding materials</p>
</caption>
<graphic xlink:href="JIPS-15-102-g015"></graphic>
</fig>
<table-wrap id="T6" position="float">
<label>Table 6</label>
<caption>
<p>ANOVA</p>
</caption>
<graphic xlink:href="JIPS-15-102-g016"></graphic>
</table-wrap>
<table-wrap id="T7" position="float">
<label>Table 7</label>
<caption>
<p>Multiple comparison of height of sulcus of control group with other four groups using
<italic>post-hoc</italic>
Bonferroni test</p>
</caption>
<graphic xlink:href="JIPS-15-102-g017"></graphic>
</table-wrap>
<table-wrap id="T8" position="float">
<label>Table 8</label>
<caption>
<p>Multiple comparison of height within groups using
<italic>post-hoc</italic>
Bonferroni test</p>
</caption>
<graphic xlink:href="JIPS-15-102-g018"></graphic>
</table-wrap>
</sec>
<sec id="sec2-10">
<title>Area</title>
<p>The mean area of the sulcus in Group 2 (211.452 ± 55.205 mm) was closest to control group (216.582 ± 53.833 mm
<sup>2</sup>
) whereas Group 4 (303.823 ± 86.531 mm
<sup>2</sup>
) was farthest [
<xref ref-type="table" rid="T9">Table 9</xref>
and
<xref ref-type="fig" rid="F11">Graph 3</xref>
]. One-way ANOVA analysis showed that mean sulcus area obtained by border molding with four different materials was significant between groups. Statistical analysis reveals that comparison of the difference among the groups is significant (
<italic>P</italic>
= 0.001). This means that none of the four test materials records the border morphology better than tissue conditioner [
<xref ref-type="table" rid="T10">Table 10</xref>
]. Multiple comparisons of different groups, when compared with the control group using
<italic>post-hoc</italic>
Bonferroni test shows that the difference of mean of the area between Group 4 and control group (87.294 mm) was significant (
<italic>P</italic>
= 0.003). Comparisons with other groups was nonsignificant [
<xref ref-type="table" rid="T11">Table 11</xref>
]. The difference of mean of the area of sulcus obtained with polyether (Group 2) and periphery wax (Group 4) (92.371 mm) was significant (
<italic>P</italic>
= 0.002) [
<xref ref-type="table" rid="T12">Table 12</xref>
].</p>
<table-wrap id="T9" position="float">
<label>Table 9</label>
<caption>
<p>Mean of area of sulcus in different groups (mm
<sup>2</sup>
)</p>
</caption>
<graphic xlink:href="JIPS-15-102-g019"></graphic>
</table-wrap>
<fig id="F11" position="float">
<label>Graph 3</label>
<caption>
<p>Comparing area of sulcus with different border molding materials</p>
</caption>
<graphic xlink:href="JIPS-15-102-g020"></graphic>
</fig>
<table-wrap id="T10" position="float">
<label>Table 10</label>
<caption>
<p>ANOVA</p>
</caption>
<graphic xlink:href="JIPS-15-102-g021"></graphic>
</table-wrap>
<table-wrap id="T11" position="float">
<label>Table 11</label>
<caption>
<p>Multiple comparison of area of control group with other four groups using
<italic>post-hoc</italic>
Bonferroni test</p>
</caption>
<graphic xlink:href="JIPS-15-102-g022"></graphic>
</table-wrap>
<table-wrap id="T12" position="float">
<label>Table 12</label>
<caption>
<p>Multiple comparison of area of sulcus within groups using
<italic>post-hoc</italic>
Bonferroni test</p>
</caption>
<graphic xlink:href="JIPS-15-102-g023"></graphic>
</table-wrap>
</sec>
</sec>
<sec sec-type="discussion" id="sec1-4">
<title>DISCUSSION</title>
<p>A frequent error during border molding is operator himself trying to mold the vestibular tissues around the periphery of the tray by forcing various movements of lips and cheeks. Pulling the cheeks and lips do not involve muscular contraction of these tissues. When true muscle contraction takes place, the length of muscle is reduced, and belly formation occurs. Hence, passive method of border molding is not truly functional or physiological.</p>
<p>Furthermore, according to Jankelson and Radke[
<xref rid="ref4" ref-type="bibr">4</xref>
] conventional manipulative movements of the cheeks and lips during the impression procedures will inevitably result in under extensions of the borders when the muscles return to their resting lengths. On the contrary, the denture borders should lie passively against the surrounding, draping musculature in its relaxed state. The more intimate the relationship of the border to the musculature, the greater will be the retention. In view of these facts and the findings, in the present study, functional border molding was done as an alternative to the currently employed conventional approaches.</p>
<p>The measurements of the exact extent of limiting structure cannot be done by any intraoral means and hence tissue conditioners were employed as control. Tissue conditioner is a material that flows for a period of time and gives the exact border morphology of the tissues as shown by Abdel-hakim
<italic>et al</italic>
.[
<xref rid="ref5" ref-type="bibr">5</xref>
] The material flows continuously under pressure at a rate inversely proportional to time, becoming stiffer but never losing its resiliency. Maintenance of viscoelastic property is key to its clinical success to be used as functional impression material. A functional impression material should flow readily under functional stress, with minimum elastic recovery ensuring continual adaptation to underlying soft tissues as they are altered under stress. Functional impressions are usually removed from patient's mouth after a few days. Recent studies recommend shorter periods of 24 h to obtain optimum results.</p>
<p>Many different materials have been tried for border molding in the past. Bolouri[
<xref rid="ref6" ref-type="bibr">6</xref>
] described the technique of border molding using wax and self-cure acrylic resin. Jones and Sobieralski[
<xref rid="ref7" ref-type="bibr">7</xref>
] reported an alternative technique of border molding using acrylic resin to conventional border molding using green stick compound. Kirk and Holt[
<xref rid="ref8" ref-type="bibr">8</xref>
] described one-step border molding technique using perio-pack. Allen and Worrollo[
<xref rid="ref9" ref-type="bibr">9</xref>
] described a technique for border molding with green stick compound heated in the microwave oven. Chaffee
<italic>et al</italic>
.[
<xref rid="ref10" ref-type="bibr">10</xref>
] described a technique for border molding edentulous impressions using vinyl polysiloxane material. Olivieri
<italic>et al</italic>
.[
<xref rid="ref11" ref-type="bibr">11</xref>
] described a technique for border molding using light polymerized resin. Solomon[
<xref rid="ref12" ref-type="bibr">12</xref>
] studied the single stage silicone border molded closed mouth impression technique. This study describes an active closed mouth impression technique with one stage border molding using putty silicone material as a substitute for low fusing compound. Mittal
<italic>et al</italic>
.[
<xref rid="ref13" ref-type="bibr">13</xref>
] stated an impression technique with one stage border molding using putty silicone material as substitute for low fusing compound and light body silicone as substitute for low fusing compound and light body silicone as substitute for metallic oxide paste. Furthermore, Kinra
<italic>et al</italic>
.[
<xref rid="ref14" ref-type="bibr">14</xref>
] presented an innovative impression technique for complete dentures. A single stage border molding using putty silicone impression material is presented as an alternative to conventional border molding. Qureshi and Rashid[
<xref rid="ref15" ref-type="bibr">15</xref>
] critically evaluated the materials and procedures used for functional peripheral molding of special trays. It was concluded that use of thermoplastic compound should be kept to minimum due to availability of simpler technique and easy to handle and accurate modern materials like polyether for single step border molding, nonbrittle waxes and light polymerized resin requiring less armamentarium McCarthy and Moser[
<xref rid="ref16" ref-type="bibr">16</xref>
] in his study proved tissue conditioner to be ideal functional impression material.</p>
<p>Krysinski and Prylinski[
<xref rid="ref17" ref-type="bibr">17</xref>
] observed that anterior segment of the impression was most reproducible as in this area muscles have fibers directed perpendicular to the border of impression when compared to the buccinator muscle with its horizontal fibers. Hence, anterior labial sulcus was selected for study.</p>
<p>The borders recorded with low fusing impression compound were wider but shorter than polyether. As low fusing impression compound is not thixotropic material, it slumps because of gravity and no manipulation was done by the operator to push the material into the sulcus. Further as it lacks thixotropicity, it cannot maintain its height when bulk is added along the border. The subsequent functional movements would be less effective in reducing the thickness of the borders because of short working time and high viscosity of low-fusing impression compound.</p>
<p>Mean of height of sulcus of Group 4 (periphery wax) was farthest from the control group as periphery wax does not flow freely, when at mouth temperature. Thus, periphery wax does not give accurate borders when functional molding is done as it needs to be softened repeatedly outside mouth in warm water. Width and height of sulcus of Group 3 (pattern resin) were of the intermediate value when compared with other groups and control group as pattern resin has sufficient working time of 2 min and has good flow characteristics. It's working time and flow is not as good as polyether, so values are intermediate.</p>
<p>When the difference in the means of different groups were observed, border surface area recorded using tissue conditioner that is, control group (216.529 mm) and low fusing impression compound that is, Group 1 (240.423 mm) was of intermediate value when compared with other groups. The difference between border area values of tissue conditioner and low fusing impression compound may be because of the heat involved in the manipulation of low-fusing impression compound. Heat can prevent the patient's co-operation in performing functional movements, it tends to be messy, and it is difficult to determine the consistency and proper temperature.</p>
<p>The technique of using impression compound for border molding is usually divided into steps where borders are molded in separate sections. Because of the number of insertions required, such a technique can be tedious and difficult. Molding the borders with low fusing impression compound distorted the tissues more than those molded by tissue conditioner. This is because peripheral tissues are readily displaceable with least manipulation.</p>
<p>It was seen that border surface area of polyether (211.452 mm) was closest in dimension to that of tissue conditioner (216.528 mm) as listed in
<xref ref-type="table" rid="T9">Table 9</xref>
. This observation could be due to the fact that the polyether gives optimum working time and exhibits good flow characteristics which help in recording the borders accurately.</p>
<p>As the border molding performed with polyether is a single step procedure, it has two advantages. (1) Number of insertions of trays for border molding could be reduced which is a great time and motion advantage. (2) Development of all borders simultaneously avoids propagation of errors.</p>
<p>The mean border area value for pattern resin (Group 3) was 251.676 mm which was of the intermediate value when compared with other groups. This can be attributed to the fact that pattern resin exhibits good flow characteristics also it releases minimum heat as compared to autopolymerizing acrylic resin, so it does not interfere with functional border molding. The only practical difficulty with pattern resin is rigidity that contraindicates its use in case of undercuts and difficulty in recovery of cast. The mean border area value for periphery wax 303.823 mm which was largest when compared with other groups. This can be attributed to the fact that the periphery was softened with warm water outside the mouth, and it does not flow properly at mouth temperature so it becomes hard again before functional molding can be completed. Literature is scanty on the use of waxes as border molding material. This observation can be attributed to the fact that waxes have a good flow at a temperature higher than that of the mouth so do not flow properly in the mouth. Periphery wax, unlike low fusing impression, is not brittle and can easily be trimmed with a knife. It reduces the chair side time, but this method is technique sensitive.</p>
<p>The removal of the tray from the mouth may cause distortion of wax if not done carefully and when deep undercuts are present if the bulk of wax at the borders of the tray is insufficient. Periphery wax permits the unattached peripheral mucosa to move when registered and not be imprisoned by the use of materials that have a short flow time. The border seal that is produced in this manner will enhance retention.</p>
</sec>
<sec sec-type="conclusions" id="sec1-5">
<title>CONCLUSIONS</title>
<p>Thus within the limitations of the study it was concluded that:</p>
<p>
<list list-type="bullet">
<list-item>
<p>Mean border height, width and area obtained by the polyether was found out to be most close to control the group</p>
</list-item>
<list-item>
<p>Mean width of borders obtained by the polyether was closest and green stick was farthest from the control group.</p>
</list-item>
<list-item>
<p>Mean height of borders obtained by the polyether was closest and of the periphery wax was farthest from the control group</p>
</list-item>
<list-item>
<p>Mean area of borders obtained by the polyether was closest and of the periphery wax was farthest from the control group.</p>
</list-item>
</list>
</p>
<p>Hence, based on the study it is concluded that the polyether was the best material for border molding which will give most accurate borders to a denture.</p>
</sec>
</body>
<back>
<fn-group>
<fn fn-type="supported-by">
<p>
<bold>Source of Support:</bold>
Nil</p>
</fn>
<fn fn-type="conflict">
<p>
<bold>Conflict of Interest:</bold>
None.</p>
</fn>
</fn-group>
<ref-list>
<title>REFERENCES</title>
<ref id="ref1">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fisher</surname>
<given-names>RD</given-names>
</name>
</person-group>
<article-title>Six fundamental rules for making full denture impressions</article-title>
<source>J Prosthet Dent</source>
<year>1951</year>
<volume>1</volume>
<fpage>135</fpage>
<lpage>44</lpage>
<pub-id pub-id-type="pmid">14814656</pub-id>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Klein</surname>
<given-names>IE</given-names>
</name>
<name>
<surname>Broner</surname>
<given-names>AS</given-names>
</name>
</person-group>
<article-title>Complete denture secondary impression technique to minimize distortion of ridge and border tissues</article-title>
<source>J Prosthet Dent</source>
<year>1985</year>
<volume>54</volume>
<fpage>660</fpage>
<lpage>4</lpage>
<pub-id pub-id-type="pmid">3903136</pub-id>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Smith</surname>
<given-names>DE</given-names>
</name>
<name>
<surname>Toolson</surname>
<given-names>LB</given-names>
</name>
<name>
<surname>Bolender</surname>
<given-names>CL</given-names>
</name>
<name>
<surname>Lord</surname>
<given-names>JL</given-names>
</name>
</person-group>
<article-title>One-step border molding of complete denture impressions using a polyether impression material</article-title>
<source>J Prosthet Dent</source>
<year>1979</year>
<volume>41</volume>
<fpage>347</fpage>
<lpage>51</lpage>
<pub-id pub-id-type="pmid">368323</pub-id>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jankelson</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Radke</surname>
<given-names>JC</given-names>
</name>
</person-group>
<article-title>The myo-monitor: Its use and abuse (I)</article-title>
<source>Quintessence Int Dent Dig</source>
<year>1978</year>
<volume>9</volume>
<fpage>47</fpage>
<lpage>52</lpage>
<pub-id pub-id-type="pmid">275947</pub-id>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abdel-Hakim</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>al-Dalgan</surname>
<given-names>SA</given-names>
</name>
<name>
<surname>al-Bishre</surname>
<given-names>GM</given-names>
</name>
</person-group>
<article-title>Displacement of border tissues during final impression procedures</article-title>
<source>J Prosthet Dent</source>
<year>1994</year>
<volume>71</volume>
<fpage>133</fpage>
<lpage>8</lpage>
<pub-id pub-id-type="pmid">8126666</pub-id>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bolouri</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>The use of wax and self-curing acrylic resin in border molding</article-title>
<source>J Prosthet Dent</source>
<year>1977</year>
<volume>37</volume>
<fpage>89</fpage>
<lpage>91</lpage>
<pub-id pub-id-type="pmid">318698</pub-id>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jones</surname>
<given-names>JD</given-names>
</name>
<name>
<surname>Sobieralski</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>An alternative approach to conventional border molding</article-title>
<source>J Prosthet Dent</source>
<year>1985</year>
<volume>53</volume>
<fpage>745</fpage>
<lpage>6</lpage>
<pub-id pub-id-type="pmid">3889316</pub-id>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kirk</surname>
<given-names>GA</given-names>
</name>
<name>
<surname>Holt</surname>
<given-names>JE</given-names>
</name>
</person-group>
<article-title>One-step border molding</article-title>
<source>J Prosthet Dent</source>
<year>1985</year>
<volume>53</volume>
<fpage>598</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">3889293</pub-id>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Allen</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Worrollo</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Border molding with composition heated in a microwave oven</article-title>
<source>J Prosthet Dent</source>
<year>1991</year>
<volume>65</volume>
<fpage>325</fpage>
<pub-id pub-id-type="pmid">2051373</pub-id>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chaffee</surname>
<given-names>NR</given-names>
</name>
<name>
<surname>Cooper</surname>
<given-names>LF</given-names>
</name>
<name>
<surname>Felton</surname>
<given-names>DA</given-names>
</name>
</person-group>
<article-title>A technique for border molding edentulous impressions using vinyl polysiloxane material</article-title>
<source>J Prosthodont</source>
<year>1999</year>
<volume>8</volume>
<fpage>129</fpage>
<lpage>34</lpage>
<pub-id pub-id-type="pmid">10740512</pub-id>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Olivieri</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Zuccari</surname>
<given-names>AG</given-names>
</name>
<name>
<surname>Olivieri</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>A technique for border molding with light-polymerized resin</article-title>
<source>J Prosthet Dent</source>
<year>2003</year>
<volume>90</volume>
<fpage>101</fpage>
<pub-id pub-id-type="pmid">12869979</pub-id>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Solomon</surname>
<given-names>EG</given-names>
</name>
</person-group>
<article-title>Single stage silicone border molded closed mouth impression Technique-part II</article-title>
<source>J Indian Prosthodont Soc</source>
<year>2011</year>
<volume>11</volume>
<fpage>183</fpage>
<lpage>8</lpage>
<pub-id pub-id-type="pmid">22942578</pub-id>
</element-citation>
</ref>
<ref id="ref13">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mittal</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Gupta</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Sharma</surname>
<given-names>H</given-names>
</name>
</person-group>
<article-title>Single step silicone border molding technique for edentulous impression</article-title>
<source>Int J Clin Cases Invest</source>
<year>2012</year>
<volume>4</volume>
<fpage>85</fpage>
<lpage>90</lpage>
</element-citation>
</ref>
<ref id="ref14">
<label>14</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kinra</surname>
<given-names>MS</given-names>
</name>
<name>
<surname>Verma</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Nagpal</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Verma</surname>
<given-names>PR</given-names>
</name>
<name>
<surname>Kalra</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Kinra</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Innovative impression technique for complete denture patients</article-title>
<source>Indian J Dent Sci</source>
<year>2013</year>
<volume>5</volume>
<fpage>34</fpage>
<lpage>6</lpage>
</element-citation>
</ref>
<ref id="ref15">
<label>15</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Qureshi</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Rashid</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Critical evaluation of materials and procedures used for the functional peripheral moulding</article-title>
<source>J Pak Dent Assoc</source>
<year>2010</year>
<volume>19</volume>
<fpage>129</fpage>
<lpage>32</lpage>
</element-citation>
</ref>
<ref id="ref16">
<label>16</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>McCarthy</surname>
<given-names>JA</given-names>
</name>
<name>
<surname>Moser</surname>
<given-names>JB</given-names>
</name>
</person-group>
<article-title>Tissue conditioners as functional impression materials</article-title>
<source>J Oral Rehabil</source>
<year>1978</year>
<volume>5</volume>
<fpage>357</fpage>
<lpage>64</lpage>
<pub-id pub-id-type="pmid">280636</pub-id>
</element-citation>
</ref>
<ref id="ref17">
<label>17</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Krysinski</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Prylinski</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Reproducibility of the border outline of working impressions of the edentulous mandible obtained by the Slack-Herbst method</article-title>
<source>J Nihon Univ Sch Dent</source>
<year>1986</year>
<volume>28</volume>
<fpage>139</fpage>
<lpage>45</lpage>
<pub-id pub-id-type="pmid">3531429</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 0006900 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 0006900 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     
   |texte=   
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022