Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement

Identifieur interne : 001052 ( Pmc/Checkpoint ); précédent : 001051; suivant : 001053

Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement

Auteurs : Wei Geng [République populaire de Chine] ; Changying Liu [République populaire de Chine] ; Yucheng Su [République populaire de Chine] ; Jun Li [République populaire de Chine] ; Yanmin Zhou [République populaire de Chine]

Source :

RBID : PMC:4538014

Abstract

Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement.


Url:
PubMed: 26309497
PubMed Central: 4538014


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4538014

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement</title>
<author>
<name sortKey="Geng, Wei" sort="Geng, Wei" uniqKey="Geng W" first="Wei" last="Geng">Wei Geng</name>
<affiliation wicri:level="1">
<nlm:aff id="au1">
<institution>Department of Dental Implantology Centre, Stomatology Hospital of Jilin University</institution>
<addr-line>Changchun 130021, Jilin Province, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Changchun 130021, Jilin Province</wicri:regionArea>
<wicri:noRegion>Jilin Province</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<nlm:aff id="au2">
<institution>Department of Dental Implantology Centre, School of Stomatology, Capital Medical University</institution>
<addr-line>Beijing 100050, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100050</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Liu, Changying" sort="Liu, Changying" uniqKey="Liu C" first="Changying" last="Liu">Changying Liu</name>
<affiliation wicri:level="1">
<nlm:aff id="au2">
<institution>Department of Dental Implantology Centre, School of Stomatology, Capital Medical University</institution>
<addr-line>Beijing 100050, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100050</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Su, Yucheng" sort="Su, Yucheng" uniqKey="Su Y" first="Yucheng" last="Su">Yucheng Su</name>
<affiliation wicri:level="1">
<nlm:aff id="au3">
<institution>Department of Dental Implantology of Peking Union Medical College Hospital</institution>
<addr-line>Beijing 100032, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100032</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Li, Jun" sort="Li, Jun" uniqKey="Li J" first="Jun" last="Li">Jun Li</name>
<affiliation wicri:level="1">
<nlm:aff id="au2">
<institution>Department of Dental Implantology Centre, School of Stomatology, Capital Medical University</institution>
<addr-line>Beijing 100050, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100050</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Zhou, Yanmin" sort="Zhou, Yanmin" uniqKey="Zhou Y" first="Yanmin" last="Zhou">Yanmin Zhou</name>
<affiliation wicri:level="1">
<nlm:aff id="au1">
<institution>Department of Dental Implantology Centre, Stomatology Hospital of Jilin University</institution>
<addr-line>Changchun 130021, Jilin Province, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Changchun 130021, Jilin Province</wicri:regionArea>
<wicri:noRegion>Jilin Province</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">26309497</idno>
<idno type="pmc">4538014</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4538014</idno>
<idno type="RBID">PMC:4538014</idno>
<date when="2015">2015</date>
<idno type="wicri:Area/Pmc/Corpus">000210</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000210</idno>
<idno type="wicri:Area/Pmc/Curation">000210</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000210</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001052</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">001052</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement</title>
<author>
<name sortKey="Geng, Wei" sort="Geng, Wei" uniqKey="Geng W" first="Wei" last="Geng">Wei Geng</name>
<affiliation wicri:level="1">
<nlm:aff id="au1">
<institution>Department of Dental Implantology Centre, Stomatology Hospital of Jilin University</institution>
<addr-line>Changchun 130021, Jilin Province, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Changchun 130021, Jilin Province</wicri:regionArea>
<wicri:noRegion>Jilin Province</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<nlm:aff id="au2">
<institution>Department of Dental Implantology Centre, School of Stomatology, Capital Medical University</institution>
<addr-line>Beijing 100050, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100050</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Liu, Changying" sort="Liu, Changying" uniqKey="Liu C" first="Changying" last="Liu">Changying Liu</name>
<affiliation wicri:level="1">
<nlm:aff id="au2">
<institution>Department of Dental Implantology Centre, School of Stomatology, Capital Medical University</institution>
<addr-line>Beijing 100050, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100050</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Su, Yucheng" sort="Su, Yucheng" uniqKey="Su Y" first="Yucheng" last="Su">Yucheng Su</name>
<affiliation wicri:level="1">
<nlm:aff id="au3">
<institution>Department of Dental Implantology of Peking Union Medical College Hospital</institution>
<addr-line>Beijing 100032, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100032</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Li, Jun" sort="Li, Jun" uniqKey="Li J" first="Jun" last="Li">Jun Li</name>
<affiliation wicri:level="1">
<nlm:aff id="au2">
<institution>Department of Dental Implantology Centre, School of Stomatology, Capital Medical University</institution>
<addr-line>Beijing 100050, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Beijing 100050</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Zhou, Yanmin" sort="Zhou, Yanmin" uniqKey="Zhou Y" first="Yanmin" last="Zhou">Yanmin Zhou</name>
<affiliation wicri:level="1">
<nlm:aff id="au1">
<institution>Department of Dental Implantology Centre, Stomatology Hospital of Jilin University</institution>
<addr-line>Changchun 130021, Jilin Province, China</addr-line>
</nlm:aff>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Changchun 130021, Jilin Province</wicri:regionArea>
<wicri:noRegion>Jilin Province</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International Journal of Clinical and Experimental Medicine</title>
<idno type="eISSN">1940-5901</idno>
<imprint>
<date when="2015">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Int J Clin Exp Med</journal-id>
<journal-id journal-id-type="iso-abbrev">Int J Clin Exp Med</journal-id>
<journal-id journal-id-type="publisher-id">ijcem</journal-id>
<journal-title-group>
<journal-title>International Journal of Clinical and Experimental Medicine</journal-title>
</journal-title-group>
<issn pub-type="epub">1940-5901</issn>
<publisher>
<publisher-name>e-Century Publishing Corporation</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">26309497</article-id>
<article-id pub-id-type="pmc">4538014</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Geng</surname>
<given-names>Wei</given-names>
</name>
<xref ref-type="aff" rid="au1">1</xref>
<xref ref-type="aff" rid="au2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Liu</surname>
<given-names>Changying</given-names>
</name>
<xref ref-type="aff" rid="au2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Su</surname>
<given-names>Yucheng</given-names>
</name>
<xref ref-type="aff" rid="au3">3</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Li</surname>
<given-names>Jun</given-names>
</name>
<xref ref-type="aff" rid="au2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Zhou</surname>
<given-names>Yanmin</given-names>
</name>
<xref ref-type="aff" rid="au1">1</xref>
</contrib>
<aff id="au1">
<label>1</label>
<institution>Department of Dental Implantology Centre, Stomatology Hospital of Jilin University</institution>
<addr-line>Changchun 130021, Jilin Province, China</addr-line>
</aff>
<aff id="au2">
<label>2</label>
<institution>Department of Dental Implantology Centre, School of Stomatology, Capital Medical University</institution>
<addr-line>Beijing 100050, China</addr-line>
</aff>
<aff id="au3">
<label>3</label>
<institution>Department of Dental Implantology of Peking Union Medical College Hospital</institution>
<addr-line>Beijing 100032, China</addr-line>
</aff>
</contrib-group>
<author-notes>
<corresp>
<bold>Address correspondence to:</bold>
Dr. Yanmin Zhou, Department of Dental Implantology Centre, Stomatology Hospital of Jilin University, Changchun 130021, Jilin Province, China. Tel: 86-431-88796025; Fax: 86-431-88975348; E-mail:
<email>dentistzhouym@126.com</email>
</corresp>
</author-notes>
<pub-date pub-type="collection">
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>15</day>
<month>6</month>
<year>2015</year>
</pub-date>
<volume>8</volume>
<issue>6</issue>
<fpage>8442</fpage>
<lpage>8449</lpage>
<history>
<date date-type="received">
<day>14</day>
<month>3</month>
<year>2015</year>
</date>
<date date-type="accepted">
<day>20</day>
<month>5</month>
<year>2015</year>
</date>
</history>
<permissions>
<copyright-statement>IJCEM Copyright © 2015</copyright-statement>
<copyright-year>2015</copyright-year>
</permissions>
<abstract>
<p>Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement.</p>
</abstract>
<kwd-group>
<kwd>Dental implant</kwd>
<kwd>surgical guide</kwd>
<kwd>computer-aided design/computer-aided manufacturing</kwd>
<kwd>osseointegration</kwd>
<kwd>tooth-supported guide</kwd>
<kwd>mucosa-supported guide</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
<affiliations>
<list>
<country>
<li>République populaire de Chine</li>
</country>
</list>
<tree>
<country name="République populaire de Chine">
<noRegion>
<name sortKey="Geng, Wei" sort="Geng, Wei" uniqKey="Geng W" first="Wei" last="Geng">Wei Geng</name>
</noRegion>
<name sortKey="Geng, Wei" sort="Geng, Wei" uniqKey="Geng W" first="Wei" last="Geng">Wei Geng</name>
<name sortKey="Li, Jun" sort="Li, Jun" uniqKey="Li J" first="Jun" last="Li">Jun Li</name>
<name sortKey="Liu, Changying" sort="Liu, Changying" uniqKey="Liu C" first="Changying" last="Liu">Changying Liu</name>
<name sortKey="Su, Yucheng" sort="Su, Yucheng" uniqKey="Su Y" first="Yucheng" last="Su">Yucheng Su</name>
<name sortKey="Zhou, Yanmin" sort="Zhou, Yanmin" uniqKey="Zhou Y" first="Yanmin" last="Zhou">Yanmin Zhou</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001052 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd -nk 001052 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Checkpoint
   |type=    RBID
   |clé=     PMC:4538014
   |texte=   Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/RBID.i   -Sk "pubmed:26309497" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022