Full digital workflow for implant-prosthetic rehabilitations: a case report

Identifieur interne : 000680 ( Pmc/Checkpoint ); précédent : 000679; suivant : 000681

Full digital workflow for implant-prosthetic rehabilitations: a case report

Auteurs : L. Arcuri ; C. Lorenzi ; F. Cecchetti ; F. Germano ; M. Spuntarelli ; A. Barlattani

Source :

RBID : PMC:5159894

Abstract

SUMMARYObjectives

The aim of the present study was to describe a proof of concept digital workflow for the implant-prosthetic treatment in partially edentate patients and evaluate its clinical performance.

Methods

A 55-year-old woman with a Kennedy class III bilateral edentulism in the mandible has been selected for a computer guided implantology according with the Smart Fusion® protocol (NobelBiocare, Kloten, Switzerland). After the template-guided implant placement, an immediate loading of the implants has been performed. QuickTemp conical temporary abutments were selected to deliver immediately prefabricated cement-retained provisionals. Two months after an impression was taken with an intraoral digital scanner (3Shape Trios3, Copenhagen, Denmark). The provisional restoration optical scanning was used to transfer the functionalized prosthetic contour to be duplicated into the definitive porcelain fused to zirconia restoration cemented on customized titanium abutments.

Results

A satisfying esthetic and functional result has been achieved. No biological and mechanical complications were recorded.

Conclusions

The investigated fully digital implant-prosthetic protocol provided a smooth, complication free and time effective treatment alternative to the conventional workflow.

Besides the fully digital workflow allowed the surgical and prosthetic decision making and the communication within the dental team and with the patient. Further improvements heading to a direct match between the intraoral scan and the CBCT are strongly advised in order to create the so-called virtual patient.


Url:
DOI: 10.11138/orl/2015.8.4.114
PubMed: 28042423
PubMed Central: 5159894


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:5159894

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Full digital workflow for implant-prosthetic rehabilitations: a case report</title>
<author>
<name sortKey="Arcuri, L" sort="Arcuri, L" uniqKey="Arcuri L" first="L." last="Arcuri">L. Arcuri</name>
</author>
<author>
<name sortKey="Lorenzi, C" sort="Lorenzi, C" uniqKey="Lorenzi C" first="C." last="Lorenzi">C. Lorenzi</name>
</author>
<author>
<name sortKey="Cecchetti, F" sort="Cecchetti, F" uniqKey="Cecchetti F" first="F." last="Cecchetti">F. Cecchetti</name>
</author>
<author>
<name sortKey="Germano, F" sort="Germano, F" uniqKey="Germano F" first="F." last="Germano">F. Germano</name>
</author>
<author>
<name sortKey="Spuntarelli, M" sort="Spuntarelli, M" uniqKey="Spuntarelli M" first="M." last="Spuntarelli">M. Spuntarelli</name>
</author>
<author>
<name sortKey="Barlattani, A" sort="Barlattani, A" uniqKey="Barlattani A" first="A." last="Barlattani">A. Barlattani</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">28042423</idno>
<idno type="pmc">5159894</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5159894</idno>
<idno type="RBID">PMC:5159894</idno>
<idno type="doi">10.11138/orl/2015.8.4.114</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">001B10</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">001B10</idno>
<idno type="wicri:Area/Pmc/Curation">001B10</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">001B10</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000680</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000680</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Full digital workflow for implant-prosthetic rehabilitations: a case report</title>
<author>
<name sortKey="Arcuri, L" sort="Arcuri, L" uniqKey="Arcuri L" first="L." last="Arcuri">L. Arcuri</name>
</author>
<author>
<name sortKey="Lorenzi, C" sort="Lorenzi, C" uniqKey="Lorenzi C" first="C." last="Lorenzi">C. Lorenzi</name>
</author>
<author>
<name sortKey="Cecchetti, F" sort="Cecchetti, F" uniqKey="Cecchetti F" first="F." last="Cecchetti">F. Cecchetti</name>
</author>
<author>
<name sortKey="Germano, F" sort="Germano, F" uniqKey="Germano F" first="F." last="Germano">F. Germano</name>
</author>
<author>
<name sortKey="Spuntarelli, M" sort="Spuntarelli, M" uniqKey="Spuntarelli M" first="M." last="Spuntarelli">M. Spuntarelli</name>
</author>
<author>
<name sortKey="Barlattani, A" sort="Barlattani, A" uniqKey="Barlattani A" first="A." last="Barlattani">A. Barlattani</name>
</author>
</analytic>
<series>
<title level="j">Oral & Implantology</title>
<idno type="ISSN">1974-5648</idno>
<idno type="eISSN">2035-2468</idno>
<imprint>
<date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<title>SUMMARY</title>
<sec>
<title>Objectives</title>
<p>The aim of the present study was to describe a proof of concept digital workflow for the implant-prosthetic treatment in partially edentate patients and evaluate its clinical performance.</p>
</sec>
<sec>
<title>Methods</title>
<p>A 55-year-old woman with a Kennedy class III bilateral edentulism in the mandible has been selected for a computer guided implantology according with the Smart Fusion® protocol (NobelBiocare, Kloten, Switzerland). After the template-guided implant placement, an immediate loading of the implants has been performed. QuickTemp conical temporary abutments were selected to deliver immediately prefabricated cement-retained provisionals. Two months after an impression was taken with an intraoral digital scanner (3Shape Trios3, Copenhagen, Denmark). The provisional restoration optical scanning was used to transfer the functionalized prosthetic contour to be duplicated into the definitive porcelain fused to zirconia restoration cemented on customized titanium abutments.</p>
</sec>
<sec>
<title>Results</title>
<p>A satisfying esthetic and functional result has been achieved. No biological and mechanical complications were recorded.</p>
</sec>
<sec>
<title>Conclusions</title>
<p>The investigated fully digital implant-prosthetic protocol provided a smooth, complication free and time effective treatment alternative to the conventional workflow.</p>
<p>Besides the fully digital workflow allowed the surgical and prosthetic decision making and the communication within the dental team and with the patient. Further improvements heading to a direct match between the intraoral scan and the CBCT are strongly advised in order to create the so-called virtual patient.</p>
</sec>
</div>
</front>
</TEI>
<pmc article-type="case-report">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Oral Implantol (Rome)</journal-id>
<journal-id journal-id-type="iso-abbrev">Oral Implantol (Rome)</journal-id>
<journal-id journal-id-type="publisher-id">OAI</journal-id>
<journal-title-group>
<journal-title>Oral & Implantology</journal-title>
</journal-title-group>
<issn pub-type="ppub">1974-5648</issn>
<issn pub-type="epub">2035-2468</issn>
<publisher>
<publisher-name>CIC Edizioni Internazionali</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">28042423</article-id>
<article-id pub-id-type="pmc">5159894</article-id>
<article-id pub-id-type="doi">10.11138/orl/2015.8.4.114</article-id>
<article-id pub-id-type="publisher-id">114-121</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Case Report</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Full digital workflow for implant-prosthetic rehabilitations: a case report</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>ARCURI</surname>
<given-names>L.</given-names>
</name>
<xref ref-type="corresp" rid="c1-114-121"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>LORENZI</surname>
<given-names>C.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>CECCHETTI</surname>
<given-names>F.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>GERMANO</surname>
<given-names>F.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>SPUNTARELLI</surname>
<given-names>M.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>BARLATTANI</surname>
<given-names>A.</given-names>
</name>
</contrib>
<aff id="af1-114-121">Department of Clinical Sciences and Translational Medicine, University of Rome “Tor Vergata”, Rome, Italy</aff>
</contrib-group>
<author-notes>
<corresp id="c1-114-121">Correspondence to: Dr. Lorenzo Arcuri, Via Cristoforo Colombo 440, 00145 Rome, Italy, Tel/Fax: +39 06 5412415, E-mail:
<email>lorenzo.arcuri@uniroma2.it</email>
</corresp>
</author-notes>
<pub-date pub-type="collection">
<season>Oct-Dec</season>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>23</day>
<month>7</month>
<year>2016</year>
</pub-date>
<volume>8</volume>
<issue>4</issue>
<fpage>114</fpage>
<lpage>121</lpage>
<permissions>
<copyright-statement>© Copyright 2015, CIC Edizioni Internazionali, Roma</copyright-statement>
<copyright-year>2015</copyright-year>
</permissions>
<abstract>
<title>SUMMARY</title>
<sec>
<title>Objectives</title>
<p>The aim of the present study was to describe a proof of concept digital workflow for the implant-prosthetic treatment in partially edentate patients and evaluate its clinical performance.</p>
</sec>
<sec>
<title>Methods</title>
<p>A 55-year-old woman with a Kennedy class III bilateral edentulism in the mandible has been selected for a computer guided implantology according with the Smart Fusion® protocol (NobelBiocare, Kloten, Switzerland). After the template-guided implant placement, an immediate loading of the implants has been performed. QuickTemp conical temporary abutments were selected to deliver immediately prefabricated cement-retained provisionals. Two months after an impression was taken with an intraoral digital scanner (3Shape Trios3, Copenhagen, Denmark). The provisional restoration optical scanning was used to transfer the functionalized prosthetic contour to be duplicated into the definitive porcelain fused to zirconia restoration cemented on customized titanium abutments.</p>
</sec>
<sec>
<title>Results</title>
<p>A satisfying esthetic and functional result has been achieved. No biological and mechanical complications were recorded.</p>
</sec>
<sec>
<title>Conclusions</title>
<p>The investigated fully digital implant-prosthetic protocol provided a smooth, complication free and time effective treatment alternative to the conventional workflow.</p>
<p>Besides the fully digital workflow allowed the surgical and prosthetic decision making and the communication within the dental team and with the patient. Further improvements heading to a direct match between the intraoral scan and the CBCT are strongly advised in order to create the so-called virtual patient.</p>
</sec>
</abstract>
<kwd-group>
<kwd>computer-guided implant surgery</kwd>
<kwd>smart fusion</kwd>
<kwd>dental implant</kwd>
<kwd>digital impression</kwd>
<kwd>intraoral scanner</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Arcuri, L" sort="Arcuri, L" uniqKey="Arcuri L" first="L." last="Arcuri">L. Arcuri</name>
<name sortKey="Barlattani, A" sort="Barlattani, A" uniqKey="Barlattani A" first="A." last="Barlattani">A. Barlattani</name>
<name sortKey="Cecchetti, F" sort="Cecchetti, F" uniqKey="Cecchetti F" first="F." last="Cecchetti">F. Cecchetti</name>
<name sortKey="Germano, F" sort="Germano, F" uniqKey="Germano F" first="F." last="Germano">F. Germano</name>
<name sortKey="Lorenzi, C" sort="Lorenzi, C" uniqKey="Lorenzi C" first="C." last="Lorenzi">C. Lorenzi</name>
<name sortKey="Spuntarelli, M" sort="Spuntarelli, M" uniqKey="Spuntarelli M" first="M." last="Spuntarelli">M. Spuntarelli</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Pmc/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000680 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd -nk 000680 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Pmc
   |étape=   Checkpoint
   |type=    RBID
   |clé=     PMC:5159894
   |texte=   Full digital workflow for implant-prosthetic rehabilitations: a case report
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/RBID.i   -Sk "pubmed:28042423" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022