Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images : a pilot study
Identifieur interne : 000287 ( PascalFrancis/Curation ); précédent : 000286; suivant : 000288Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images : a pilot study
Auteurs : N. Van Assche [Belgique] ; D. Van Steenberghe [Belgique] ; M. E. Guerrero [Belgique] ; E. Hirsch [Allemagne] ; F. Schutyser [Belgique] ; M. Quirynen [Belgique] ; R. Jacobs [Belgique]Source :
- Journal of clinical periodontology [ 0303-6979 ] ; 2007.
Descripteurs français
- Pascal (Inist)
- Wicri :
- topic : Chirurgie.
English descriptors
- KwdEn :
Abstract
Aim: To evaluate the precision of transfer of a computer-based three-dimensional (3D) planning, using re-formatted cone-beam images, for oral implant placement in partially edentulous jaws. Material and Methods: Four formalin-fixed cadaver jaws were imaged in a 3D Accuitomo FPD® cone-beam computed tomography (CT). Data were used to produce an accurate implant planning with a transfer to surgery by means of stereolithographic drill guides. Pre-operative cone-beam CT images were subsequently matched with post-operative ones to calculate the deviation between planned and installed implants. Results: Placed implants (length: 10-15 mm) showed an average angular deviation of 2° (SD: 0.8, range: 0.7-4.0°) as compared with the planning, while the mean linear deviation was 1.1 mm (SD: 0.7mm, range 0.3-2.3 mm) at the hex and 2.0mm (SD: 0.7 mm, range 0.7-2.4 mm) at the tip. Conclusions: Cone-beam images could be used for implant planning, taking into account a maximal 4° angular and 2.4 mm linear deviation at the apical tip.
pA |
|
---|
Links toward previous steps (curation, corpus...)
- to stream PascalFrancis, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000416
Links to Exploration step
Pascal:07-0427844Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images : a pilot study</title>
<author><name sortKey="Van Assche, N" sort="Van Assche, N" uniqKey="Van Assche N" first="N." last="Van Assche">N. Van Assche</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Van Steenberghe, D" sort="Van Steenberghe, D" uniqKey="Van Steenberghe D" first="D." last="Van Steenberghe">D. Van Steenberghe</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Guerrero, M E" sort="Guerrero, M E" uniqKey="Guerrero M" first="M. E." last="Guerrero">M. E. Guerrero</name>
<affiliation wicri:level="1"><inist:fA14 i1="02"><s1>Oral Imaging Center, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>3 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Hirsch, E" sort="Hirsch, E" uniqKey="Hirsch E" first="E." last="Hirsch">E. Hirsch</name>
<affiliation wicri:level="1"><inist:fA14 i1="03"><s1>Department of Radiology, Faculty of Medicine or Dental School, University of Leipzig</s1>
<s2>Leipzig</s2>
<s3>DEU</s3>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>Allemagne</country>
</affiliation>
</author>
<author><name sortKey="Schutyser, F" sort="Schutyser, F" uniqKey="Schutyser F" first="F." last="Schutyser">F. Schutyser</name>
<affiliation wicri:level="1"><inist:fA14 i1="04"><s1>Department of Medical Image Computing (Radiology -ESAT/PSI), Faculties of Medicine and Engineering, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>5 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Quirynen, M" sort="Quirynen, M" uniqKey="Quirynen M" first="M." last="Quirynen">M. Quirynen</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Jacobs, R" sort="Jacobs, R" uniqKey="Jacobs R" first="R." last="Jacobs">R. Jacobs</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
<affiliation wicri:level="1"><inist:fA14 i1="02"><s1>Oral Imaging Center, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>3 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">07-0427844</idno>
<date when="2007">2007</date>
<idno type="stanalyst">PASCAL 07-0427844 INIST</idno>
<idno type="RBID">Pascal:07-0427844</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000416</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000287</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images : a pilot study</title>
<author><name sortKey="Van Assche, N" sort="Van Assche, N" uniqKey="Van Assche N" first="N." last="Van Assche">N. Van Assche</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Van Steenberghe, D" sort="Van Steenberghe, D" uniqKey="Van Steenberghe D" first="D." last="Van Steenberghe">D. Van Steenberghe</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Guerrero, M E" sort="Guerrero, M E" uniqKey="Guerrero M" first="M. E." last="Guerrero">M. E. Guerrero</name>
<affiliation wicri:level="1"><inist:fA14 i1="02"><s1>Oral Imaging Center, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>3 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Hirsch, E" sort="Hirsch, E" uniqKey="Hirsch E" first="E." last="Hirsch">E. Hirsch</name>
<affiliation wicri:level="1"><inist:fA14 i1="03"><s1>Department of Radiology, Faculty of Medicine or Dental School, University of Leipzig</s1>
<s2>Leipzig</s2>
<s3>DEU</s3>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>Allemagne</country>
</affiliation>
</author>
<author><name sortKey="Schutyser, F" sort="Schutyser, F" uniqKey="Schutyser F" first="F." last="Schutyser">F. Schutyser</name>
<affiliation wicri:level="1"><inist:fA14 i1="04"><s1>Department of Medical Image Computing (Radiology -ESAT/PSI), Faculties of Medicine and Engineering, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>5 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Quirynen, M" sort="Quirynen, M" uniqKey="Quirynen M" first="M." last="Quirynen">M. Quirynen</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
<author><name sortKey="Jacobs, R" sort="Jacobs, R" uniqKey="Jacobs R" first="R." last="Jacobs">R. Jacobs</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
<affiliation wicri:level="1"><inist:fA14 i1="02"><s1>Oral Imaging Center, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>3 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
<country>Belgique</country>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Journal of clinical periodontology</title>
<title level="j" type="abbreviated">J. clin. periodontol.</title>
<idno type="ISSN">0303-6979</idno>
<imprint><date when="2007">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Journal of clinical periodontology</title>
<title level="j" type="abbreviated">J. clin. periodontol.</title>
<idno type="ISSN">0303-6979</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Accuracy</term>
<term>Bone</term>
<term>Computer aid</term>
<term>Computerized axial tomography</term>
<term>Dentistry</term>
<term>Edentulousness</term>
<term>Ex vivo</term>
<term>Implant</term>
<term>Jaw</term>
<term>Planning</term>
<term>Stereolithography</term>
<term>Surgery</term>
<term>Treatment</term>
<term>Tridimensional image</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Edentation</term>
<term>Chirurgie</term>
<term>Image tridimensionnelle</term>
<term>Tomodensitométrie</term>
<term>Précision</term>
<term>Implant</term>
<term>Planification</term>
<term>Assistance ordinateur</term>
<term>Ex vivo</term>
<term>Mâchoire</term>
<term>Os</term>
<term>Stéréolithographie</term>
<term>Dentisterie</term>
<term>Traitement</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Chirurgie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Aim: To evaluate the precision of transfer of a computer-based three-dimensional (3D) planning, using re-formatted cone-beam images, for oral implant placement in partially edentulous jaws. Material and Methods: Four formalin-fixed cadaver jaws were imaged in a 3D Accuitomo FPD® cone-beam computed tomography (CT). Data were used to produce an accurate implant planning with a transfer to surgery by means of stereolithographic drill guides. Pre-operative cone-beam CT images were subsequently matched with post-operative ones to calculate the deviation between planned and installed implants. Results: Placed implants (length: 10-15 mm) showed an average angular deviation of 2° (SD: 0.8, range: 0.7-4.0°) as compared with the planning, while the mean linear deviation was 1.1 mm (SD: 0.7mm, range 0.3-2.3 mm) at the hex and 2.0mm (SD: 0.7 mm, range 0.7-2.4 mm) at the tip. Conclusions: Cone-beam images could be used for implant planning, taking into account a maximal 4° angular and 2.4 mm linear deviation at the apical tip.</div>
</front>
</TEI>
<inist><standard h6="B"><pA><fA01 i1="01" i2="1"><s0>0303-6979</s0>
</fA01>
<fA03 i2="1"><s0>J. clin. periodontol.</s0>
</fA03>
<fA05><s2>34</s2>
</fA05>
<fA06><s2>9</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG"><s1>Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images : a pilot study</s1>
</fA08>
<fA11 i1="01" i2="1"><s1>VAN ASSCHE (N.)</s1>
</fA11>
<fA11 i1="02" i2="1"><s1>VAN STEENBERGHE (D.)</s1>
</fA11>
<fA11 i1="03" i2="1"><s1>GUERRERO (M. E.)</s1>
</fA11>
<fA11 i1="04" i2="1"><s1>HIRSCH (E.)</s1>
</fA11>
<fA11 i1="05" i2="1"><s1>SCHUTYSER (F.)</s1>
</fA11>
<fA11 i1="06" i2="1"><s1>QUIRYNEN (M.)</s1>
</fA11>
<fA11 i1="07" i2="1"><s1>JACOBS (R.)</s1>
</fA11>
<fA14 i1="01"><s1>Department of Periodontology, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</fA14>
<fA14 i1="02"><s1>Oral Imaging Center, Faculty of Medicine, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>3 aut.</sZ>
<sZ>7 aut.</sZ>
</fA14>
<fA14 i1="03"><s1>Department of Radiology, Faculty of Medicine or Dental School, University of Leipzig</s1>
<s2>Leipzig</s2>
<s3>DEU</s3>
<sZ>4 aut.</sZ>
</fA14>
<fA14 i1="04"><s1>Department of Medical Image Computing (Radiology -ESAT/PSI), Faculties of Medicine and Engineering, Catholic University Leuven</s1>
<s2>Leuven</s2>
<s3>BEL</s3>
<sZ>5 aut.</sZ>
</fA14>
<fA20><s1>816-821</s1>
</fA20>
<fA21><s1>2007</s1>
</fA21>
<fA23 i1="01"><s0>ENG</s0>
</fA23>
<fA43 i1="01"><s1>INIST</s1>
<s2>16273</s2>
<s5>354000161535390110</s5>
</fA43>
<fA44><s0>0000</s0>
<s1>© 2007 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45><s0>1 p.</s0>
</fA45>
<fA47 i1="01" i2="1"><s0>07-0427844</s0>
</fA47>
<fA60><s1>P</s1>
</fA60>
<fA61><s0>A</s0>
</fA61>
<fA64 i1="01" i2="1"><s0>Journal of clinical periodontology</s0>
</fA64>
<fA66 i1="01"><s0>GBR</s0>
</fA66>
<fC01 i1="01" l="ENG"><s0>Aim: To evaluate the precision of transfer of a computer-based three-dimensional (3D) planning, using re-formatted cone-beam images, for oral implant placement in partially edentulous jaws. Material and Methods: Four formalin-fixed cadaver jaws were imaged in a 3D Accuitomo FPD® cone-beam computed tomography (CT). Data were used to produce an accurate implant planning with a transfer to surgery by means of stereolithographic drill guides. Pre-operative cone-beam CT images were subsequently matched with post-operative ones to calculate the deviation between planned and installed implants. Results: Placed implants (length: 10-15 mm) showed an average angular deviation of 2° (SD: 0.8, range: 0.7-4.0°) as compared with the planning, while the mean linear deviation was 1.1 mm (SD: 0.7mm, range 0.3-2.3 mm) at the hex and 2.0mm (SD: 0.7 mm, range 0.7-2.4 mm) at the tip. Conclusions: Cone-beam images could be used for implant planning, taking into account a maximal 4° angular and 2.4 mm linear deviation at the apical tip.</s0>
</fC01>
<fC02 i1="01" i2="X"><s0>002B10C02</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE"><s0>Edentation</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG"><s0>Edentulousness</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA"><s0>Edentación</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE"><s0>Chirurgie</s0>
<s5>04</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG"><s0>Surgery</s0>
<s5>04</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA"><s0>Cirugía</s0>
<s5>04</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE"><s0>Image tridimensionnelle</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG"><s0>Tridimensional image</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA"><s0>Imagen tridimensional</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE"><s0>Tomodensitométrie</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG"><s0>Computerized axial tomography</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA"><s0>Tomodensitometría</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE"><s0>Précision</s0>
<s5>07</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG"><s0>Accuracy</s0>
<s5>07</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA"><s0>Precisión</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE"><s0>Implant</s0>
<s5>08</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG"><s0>Implant</s0>
<s5>08</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA"><s0>Implante</s0>
<s5>08</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE"><s0>Planification</s0>
<s5>09</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG"><s0>Planning</s0>
<s5>09</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA"><s0>Planificación</s0>
<s5>09</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE"><s0>Assistance ordinateur</s0>
<s5>13</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG"><s0>Computer aid</s0>
<s5>13</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA"><s0>Asistencia ordenador</s0>
<s5>13</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE"><s0>Ex vivo</s0>
<s5>14</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG"><s0>Ex vivo</s0>
<s5>14</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA"><s0>Ex vivo</s0>
<s5>14</s5>
</fC03>
<fC03 i1="10" i2="X" l="FRE"><s0>Mâchoire</s0>
<s5>15</s5>
</fC03>
<fC03 i1="10" i2="X" l="ENG"><s0>Jaw</s0>
<s5>15</s5>
</fC03>
<fC03 i1="10" i2="X" l="SPA"><s0>Maxilar</s0>
<s5>15</s5>
</fC03>
<fC03 i1="11" i2="X" l="FRE"><s0>Os</s0>
<s5>16</s5>
</fC03>
<fC03 i1="11" i2="X" l="ENG"><s0>Bone</s0>
<s5>16</s5>
</fC03>
<fC03 i1="11" i2="X" l="SPA"><s0>Hueso</s0>
<s5>16</s5>
</fC03>
<fC03 i1="12" i2="X" l="FRE"><s0>Stéréolithographie</s0>
<s5>17</s5>
</fC03>
<fC03 i1="12" i2="X" l="ENG"><s0>Stereolithography</s0>
<s5>17</s5>
</fC03>
<fC03 i1="12" i2="X" l="SPA"><s0>Stereolitografia</s0>
<s5>17</s5>
</fC03>
<fC03 i1="13" i2="X" l="FRE"><s0>Dentisterie</s0>
<s5>18</s5>
</fC03>
<fC03 i1="13" i2="X" l="ENG"><s0>Dentistry</s0>
<s5>18</s5>
</fC03>
<fC03 i1="13" i2="X" l="SPA"><s0>Odontología</s0>
<s5>18</s5>
</fC03>
<fC03 i1="14" i2="X" l="FRE"><s0>Traitement</s0>
<s5>30</s5>
</fC03>
<fC03 i1="14" i2="X" l="ENG"><s0>Treatment</s0>
<s5>30</s5>
</fC03>
<fC03 i1="14" i2="X" l="SPA"><s0>Tratamiento</s0>
<s5>30</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE"><s0>Dent pathologie</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="ENG"><s0>Dental disease</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="SPA"><s0>Diente patología</s0>
<s5>37</s5>
</fC07>
<fC07 i1="02" i2="X" l="FRE"><s0>Imagerie médicale</s0>
<s5>38</s5>
</fC07>
<fC07 i1="02" i2="X" l="ENG"><s0>Medical imagery</s0>
<s5>38</s5>
</fC07>
<fC07 i1="02" i2="X" l="SPA"><s0>Imaginería médica</s0>
<s5>38</s5>
</fC07>
<fC07 i1="03" i2="X" l="FRE"><s0>Radiodiagnostic</s0>
<s5>39</s5>
</fC07>
<fC07 i1="03" i2="X" l="ENG"><s0>Radiodiagnosis</s0>
<s5>39</s5>
</fC07>
<fC07 i1="03" i2="X" l="SPA"><s0>Radiodiagnóstico</s0>
<s5>39</s5>
</fC07>
<fC07 i1="04" i2="X" l="FRE"><s0>Stomatologie</s0>
<s5>40</s5>
</fC07>
<fC07 i1="04" i2="X" l="ENG"><s0>Stomatology</s0>
<s5>40</s5>
</fC07>
<fC07 i1="04" i2="X" l="SPA"><s0>Estomatología</s0>
<s5>40</s5>
</fC07>
<fN21><s1>281</s1>
</fN21>
<fN44 i1="01"><s1>OTO</s1>
</fN44>
<fN82><s1>OTO</s1>
</fN82>
</pA>
</standard>
</inist>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PascalFrancis/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000287 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Curation/biblio.hfd -nk 000287 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PascalFrancis |étape= Curation |type= RBID |clé= Pascal:07-0427844 |texte= Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images : a pilot study }}
This area was generated with Dilib version V0.6.32. |