Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Precision of Dental Implant Digitization Using Intraoral Scanners.

Identifieur interne : 006699 ( Ncbi/Merge ); précédent : 006698; suivant : 006700

Precision of Dental Implant Digitization Using Intraoral Scanners.

Auteurs : Tabea V. Flügge ; Wael Att ; Marc C. Metzger ; Katja Nelson

Source :

RBID : pubmed:27148990

Descripteurs français

English descriptors

Abstract

The digitization of scanbodies on dental implants is required to use computer-aided design/computer-assisted manufacture processes for implant prosthetics. Little is known about the accuracy of scanbody digitization with intraoral scanners and dental lab scanners. This study aimed to examine the precision of different intraoral digital impression systems as well as a dental lab scanner using commercially available implant scanbodies.

PubMed: 27148990

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:27148990

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Precision of Dental Implant Digitization Using Intraoral Scanners.</title>
<author>
<name sortKey="Flugge, Tabea V" sort="Flugge, Tabea V" uniqKey="Flugge T" first="Tabea V" last="Flügge">Tabea V. Flügge</name>
</author>
<author>
<name sortKey="Att, Wael" sort="Att, Wael" uniqKey="Att W" first="Wael" last="Att">Wael Att</name>
</author>
<author>
<name sortKey="Metzger, Marc C" sort="Metzger, Marc C" uniqKey="Metzger M" first="Marc C" last="Metzger">Marc C. Metzger</name>
</author>
<author>
<name sortKey="Nelson, Katja" sort="Nelson, Katja" uniqKey="Nelson K" first="Katja" last="Nelson">Katja Nelson</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2016 May-Jun</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:27148990</idno>
<idno type="pmid">27148990</idno>
<idno type="wicri:Area/PubMed/Corpus">000166</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000166</idno>
<idno type="wicri:Area/PubMed/Curation">000166</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000166</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000166</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000166</idno>
<idno type="wicri:Area/Ncbi/Merge">006699</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Precision of Dental Implant Digitization Using Intraoral Scanners.</title>
<author>
<name sortKey="Flugge, Tabea V" sort="Flugge, Tabea V" uniqKey="Flugge T" first="Tabea V" last="Flügge">Tabea V. Flügge</name>
</author>
<author>
<name sortKey="Att, Wael" sort="Att, Wael" uniqKey="Att W" first="Wael" last="Att">Wael Att</name>
</author>
<author>
<name sortKey="Metzger, Marc C" sort="Metzger, Marc C" uniqKey="Metzger M" first="Marc C" last="Metzger">Marc C. Metzger</name>
</author>
<author>
<name sortKey="Nelson, Katja" sort="Nelson, Katja" uniqKey="Nelson K" first="Katja" last="Nelson">Katja Nelson</name>
</author>
</analytic>
<series>
<title level="j">The International journal of prosthodontics</title>
<idno type="ISSN">0893-2174</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Computer-Aided Design (instrumentation)</term>
<term>Computer-Aided Design (statistics & numerical data)</term>
<term>Dental Implants</term>
<term>Dental Impression Technique (statistics & numerical data)</term>
<term>Dental Models</term>
<term>Dimensional Measurement Accuracy</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted (instrumentation)</term>
<term>Image Processing, Computer-Assisted (statistics & numerical data)</term>
<term>Jaw, Edentulous, Partially (pathology)</term>
<term>Materials Testing</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Conception assistée par ordinateur ()</term>
<term>Conception assistée par ordinateur (instrumentation)</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Modèles dentaires</term>
<term>Mâchoire partiellement édentée (anatomopathologie)</term>
<term>Précision de la mesure dimensionnelle</term>
<term>Technique de prise d'empreinte ()</term>
<term>Test de matériaux</term>
<term>Traitement d'image par ordinateur ()</term>
<term>Traitement d'image par ordinateur (instrumentation)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomopathologie" xml:lang="fr">
<term>Mâchoire partiellement édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Image Processing, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="statistics & numerical data" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Impression Technique</term>
<term>Image Processing, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Models</term>
<term>Dimensional Measurement Accuracy</term>
<term>Humans</term>
<term>Materials Testing</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Conception assistée par ordinateur</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Modèles dentaires</term>
<term>Précision de la mesure dimensionnelle</term>
<term>Technique de prise d'empreinte</term>
<term>Test de matériaux</term>
<term>Traitement d'image par ordinateur</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The digitization of scanbodies on dental implants is required to use computer-aided design/computer-assisted manufacture processes for implant prosthetics. Little is known about the accuracy of scanbody digitization with intraoral scanners and dental lab scanners. This study aimed to examine the precision of different intraoral digital impression systems as well as a dental lab scanner using commercially available implant scanbodies.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">27148990</PMID>
<DateCompleted>
<Year>2016</Year>
<Month>07</Month>
<Day>15</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>05</Month>
<Day>06</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0893-2174</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>29</Volume>
<Issue>3</Issue>
<PubDate>
<MedlineDate>2016 May-Jun</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of prosthodontics</Title>
<ISOAbbreviation>Int J Prosthodont</ISOAbbreviation>
</Journal>
<ArticleTitle>Precision of Dental Implant Digitization Using Intraoral Scanners.</ArticleTitle>
<Pagination>
<MedlinePgn>277-83</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.11607/ijp.4417</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The digitization of scanbodies on dental implants is required to use computer-aided design/computer-assisted manufacture processes for implant prosthetics. Little is known about the accuracy of scanbody digitization with intraoral scanners and dental lab scanners. This study aimed to examine the precision of different intraoral digital impression systems as well as a dental lab scanner using commercially available implant scanbodies.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Two study models with a different number and distribution of dental implant scanbodies were produced from conventional implant impressions. The study models were scanned using three different intraoral scanners (iTero, Cadent; Trios, 3Shape; and True Definition, 3M ESPE) and a dental lab scanner (D250, 3Shape). For each study model, 10 scans were performed per scanner to produce repeated measurements for the calculation of precision. The distance and angulation between the respective scanbodies were measured. The results of each scanning system were compared using analysis of variance, and post hoc Tukey test was conducted for a pairwise comparison of scanning devices.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The precision values of the scanbodies varied according to the distance between the scanbodies and the scanning device. A distance of a single tooth space and a jaw-traversing distance between scanbodies produced significantly different results for distance and angle measurements between the scanning systems (P < .05).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The precision of intraoral scanners and the dental lab scanner was significantly different. The precision of intraoral scanners decreased with an increasing distance between the scanbodies, whereas the precision of the dental lab scanner was independent of the distance between the scanbodies.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Flügge</LastName>
<ForeName>Tabea V</ForeName>
<Initials>TV</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Att</LastName>
<ForeName>Wael</ForeName>
<Initials>W</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Metzger</LastName>
<ForeName>Marc C</ForeName>
<Initials>MC</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Nelson</LastName>
<ForeName>Katja</ForeName>
<Initials>K</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Int J Prosthodont</MedlineTA>
<NlmUniqueID>8900938</NlmUniqueID>
<ISSNLinking>0893-2174</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="Y">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="N">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003761" MajorTopicYN="N">Dental Impression Technique</DescriptorName>
<QualifierName UI="Q000706" MajorTopicYN="Y">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D061827" MajorTopicYN="N">Dimensional Measurement Accuracy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007091" MajorTopicYN="N">Image Processing, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="Y">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008422" MajorTopicYN="N">Materials Testing</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2016</Year>
<Month>5</Month>
<Day>6</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2016</Year>
<Month>5</Month>
<Day>7</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2016</Year>
<Month>7</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">27148990</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Att, Wael" sort="Att, Wael" uniqKey="Att W" first="Wael" last="Att">Wael Att</name>
<name sortKey="Flugge, Tabea V" sort="Flugge, Tabea V" uniqKey="Flugge T" first="Tabea V" last="Flügge">Tabea V. Flügge</name>
<name sortKey="Metzger, Marc C" sort="Metzger, Marc C" uniqKey="Metzger M" first="Marc C" last="Metzger">Marc C. Metzger</name>
<name sortKey="Nelson, Katja" sort="Nelson, Katja" uniqKey="Nelson K" first="Katja" last="Nelson">Katja Nelson</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006699 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 006699 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:27148990
   |texte=   Precision of Dental Implant Digitization Using Intraoral Scanners.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:27148990" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022