Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques.

Identifieur interne : 003F94 ( Ncbi/Merge ); précédent : 003F93; suivant : 003F95

Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques.

Auteurs : M. Giordano [Italie] ; P. Ausiello ; M. Martorelli

Source :

RBID : pubmed:22796037

Descripteurs français

English descriptors

Abstract

In the paper laser scanning was used to evaluate, by indirect methods, the accuracy of computer-designed surgical guides in the oral implant supported rehabilitation of partially or completely edentulous patients.

DOI: 10.1016/j.dental.2012.06.006
PubMed: 22796037

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:22796037

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques.</title>
<author>
<name sortKey="Giordano, M" sort="Giordano, M" uniqKey="Giordano M" first="M" last="Giordano">M. Giordano</name>
<affiliation wicri:level="1">
<nlm:affiliation>Giordano Dental Office, Caserta, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Giordano Dental Office, Caserta</wicri:regionArea>
<wicri:noRegion>Caserta</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ausiello, P" sort="Ausiello, P" uniqKey="Ausiello P" first="P" last="Ausiello">P. Ausiello</name>
</author>
<author>
<name sortKey="Martorelli, M" sort="Martorelli, M" uniqKey="Martorelli M" first="M" last="Martorelli">M. Martorelli</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:22796037</idno>
<idno type="pmid">22796037</idno>
<idno type="doi">10.1016/j.dental.2012.06.006</idno>
<idno type="wicri:Area/PubMed/Corpus">000F40</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000F40</idno>
<idno type="wicri:Area/PubMed/Curation">000F40</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000F40</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000F40</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000F40</idno>
<idno type="wicri:Area/Ncbi/Merge">003F94</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques.</title>
<author>
<name sortKey="Giordano, M" sort="Giordano, M" uniqKey="Giordano M" first="M" last="Giordano">M. Giordano</name>
<affiliation wicri:level="1">
<nlm:affiliation>Giordano Dental Office, Caserta, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Giordano Dental Office, Caserta</wicri:regionArea>
<wicri:noRegion>Caserta</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ausiello, P" sort="Ausiello, P" uniqKey="Ausiello P" first="P" last="Ausiello">P. Ausiello</name>
</author>
<author>
<name sortKey="Martorelli, M" sort="Martorelli, M" uniqKey="Martorelli M" first="M" last="Martorelli">M. Martorelli</name>
</author>
</analytic>
<series>
<title level="j">Dental materials : official publication of the Academy of Dental Materials</title>
<idno type="eISSN">1879-0097</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Models</term>
<term>Dental Prosthesis Design (methods)</term>
<term>Female</term>
<term>Humans</term>
<term>Imaging, Three-Dimensional (instrumentation)</term>
<term>Imaging, Three-Dimensional (methods)</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Jaw, Edentulous, Partially (diagnostic imaging)</term>
<term>Jaw, Edentulous, Partially (surgery)</term>
<term>Male</term>
<term>Microscopy, Confocal</term>
<term>Middle Aged</term>
<term>Radiography</term>
<term>Surgery, Computer-Assisted (methods)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte</term>
<term>Adulte d'âge moyen</term>
<term>Chirurgie assistée par ordinateur ()</term>
<term>Conception assistée par ordinateur</term>
<term>Conception de prothèse dentaire ()</term>
<term>Femelle</term>
<term>Humains</term>
<term>Imagerie tridimensionnelle ()</term>
<term>Imagerie tridimensionnelle (instrumentation)</term>
<term>Microscopie confocale</term>
<term>Modèles dentaires</term>
<term>Mâchoire partiellement édentée ()</term>
<term>Mâchoire partiellement édentée (imagerie diagnostique)</term>
<term>Mâchoire édentée ()</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Mâle</term>
<term>Pose d'implant dentaire endo-osseux ()</term>
<term>Radiographie</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mâchoire partiellement édentée</term>
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Imaging, Three-Dimensional</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Design</term>
<term>Imaging, Three-Dimensional</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Computer-Aided Design</term>
<term>Dental Models</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Microscopy, Confocal</term>
<term>Middle Aged</term>
<term>Radiography</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="fr">
<term>Adulte</term>
<term>Adulte d'âge moyen</term>
<term>Chirurgie assistée par ordinateur</term>
<term>Conception assistée par ordinateur</term>
<term>Conception de prothèse dentaire</term>
<term>Femelle</term>
<term>Humains</term>
<term>Imagerie tridimensionnelle</term>
<term>Microscopie confocale</term>
<term>Modèles dentaires</term>
<term>Mâchoire partiellement édentée</term>
<term>Mâchoire édentée</term>
<term>Mâle</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In the paper laser scanning was used to evaluate, by indirect methods, the accuracy of computer-designed surgical guides in the oral implant supported rehabilitation of partially or completely edentulous patients.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">22796037</PMID>
<DateCompleted>
<Year>2013</Year>
<Month>02</Month>
<Day>20</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1879-0097</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>28</Volume>
<Issue>9</Issue>
<PubDate>
<Year>2012</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Dental materials : official publication of the Academy of Dental Materials</Title>
<ISOAbbreviation>Dent Mater</ISOAbbreviation>
</Journal>
<ArticleTitle>Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques.</ArticleTitle>
<Pagination>
<MedlinePgn>e178-85</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.dental.2012.06.006</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">In the paper laser scanning was used to evaluate, by indirect methods, the accuracy of computer-designed surgical guides in the oral implant supported rehabilitation of partially or completely edentulous patients.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Five implant supported rehabilitations for a total of twenty-three implants were carried out by computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. For all cases the surgical virtual planning, starting from 3D models obtained by dental scan DICOM data, was performed. The implants were inserted on the pre-surgical casts in the position defined in the virtual planning. These positions were acquired by three-dimensional optical laser scanning and compared with the laser scans of the intraoral impressions taken post-operatively.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The comparison between the post-surgical implant replica positions and the positions in the pre-operative cast, for the five patients, shows a maximum distance in the range 1.02-1.25 mm, an average distance in the range 0.21-0.41 mm and a standard deviation in the range 0.21-0.29 mm.</AbstractText>
<AbstractText Label="SIGNIFICANCE" NlmCategory="CONCLUSIONS">The results of this research demonstrate accurate transfer of implant replica position by virtual implant insertion into a pre-operative cast and a post-operative cast obtained from impressioning. In previous studies the evaluation of the implant positions have required a post-surgical CT scan. With the indirect methods by laser scanning technique, proposed in the paper, this extra radiation exposure of the patient can be eliminated.</AbstractText>
<CopyrightInformation>Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Giordano</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Giordano Dental Office, Caserta, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Ausiello</LastName>
<ForeName>P</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Martorelli</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2012</Year>
<Month>07</Month>
<Day>13</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Dent Mater</MedlineTA>
<NlmUniqueID>8508040</NlmUniqueID>
<ISSNLinking>0109-5641</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="Y">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D021621" MajorTopicYN="N">Imaging, Three-Dimensional</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D018613" MajorTopicYN="N">Microscopy, Confocal</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D025321" MajorTopicYN="N">Surgery, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2012</Year>
<Month>06</Month>
<Day>11</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2012</Year>
<Month>06</Month>
<Day>18</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2012</Year>
<Month>7</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>7</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2013</Year>
<Month>2</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">22796037</ArticleId>
<ArticleId IdType="pii">S0109-5641(12)00187-X</ArticleId>
<ArticleId IdType="doi">10.1016/j.dental.2012.06.006</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Italie</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Ausiello, P" sort="Ausiello, P" uniqKey="Ausiello P" first="P" last="Ausiello">P. Ausiello</name>
<name sortKey="Martorelli, M" sort="Martorelli, M" uniqKey="Martorelli M" first="M" last="Martorelli">M. Martorelli</name>
</noCountry>
<country name="Italie">
<noRegion>
<name sortKey="Giordano, M" sort="Giordano, M" uniqKey="Giordano M" first="M" last="Giordano">M. Giordano</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003F94 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 003F94 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:22796037
   |texte=   Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:22796037" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022