Reproducibility of interocclusal recording for mandibular removable partial denture in bilateral distal extension cases.
Identifieur interne : 000C42 ( Ncbi/Merge ); précédent : 000C41; suivant : 000C43Reproducibility of interocclusal recording for mandibular removable partial denture in bilateral distal extension cases.
Auteurs : Hiroshi Togano [Japon] ; Masayuki Hideshima ; Takashi OhyamaSource :
- Journal of medical and dental sciences [ 1342-8810 ] ; 2003.
Descripteurs français
- KwdFr :
- Analyse de variance, Cires, Conception d'appareil de prothèse dentaire, Dimension verticale, Enregistrement des rapports intermaxillaires (), Humains, Mandibule, Matériaux empreinte dentaire, Modèles dentaires, Mâchoire partiellement édentée (physiopathologie), Polyvinyles, Prothèse dentaire partielle amovible, Reproductibilité des résultats, Siloxanes, Technique de prise d'empreinte.
- MESH :
- physiopathologie : Mâchoire partiellement édentée.
- Analyse de variance, Cires, Conception d'appareil de prothèse dentaire, Dimension verticale, Enregistrement des rapports intermaxillaires, Humains, Mandibule, Matériaux empreinte dentaire, Modèles dentaires, Polyvinyles, Prothèse dentaire partielle amovible, Reproductibilité des résultats, Siloxanes, Technique de prise d'empreinte.
English descriptors
- KwdEn :
- Analysis of Variance, Dental Impression Materials, Dental Impression Technique, Dental Models, Denture Design, Denture, Partial, Removable, Humans, Jaw Relation Record (methods), Jaw, Edentulous, Partially (physiopathology), Mandible, Polyvinyls, Reproducibility of Results, Siloxanes, Vertical Dimension, Waxes.
- MESH :
- chemical : Dental Impression Materials, Polyvinyls, Siloxanes, Waxes.
- methods : Jaw Relation Record.
- physiopathology : Jaw, Edentulous, Partially.
- Analysis of Variance, Dental Impression Technique, Dental Models, Denture Design, Denture, Partial, Removable, Humans, Mandible, Reproducibility of Results, Vertical Dimension.
Abstract
Interocclusal recording for removable partial denture in bilateral mandibular distal extension were evaluated for the differences of the interocclusal recording material utilized during different impression techniques. The purpose of this study is to develop interocclusal recording utilizing occlusion rims with high accuracy. The intraoral model with urethane rubber mucosa with 3 metallic spheres as measuring points was utilized. With the applied pressure (functional) and minimum pressure (anatomical) impression techniques, working casts were fabricated. Interocclusal recording was registered with the occlusion rim on the intraoral model unto the articulator by applying the interocclusal materials; paraffin wax (PW), ALUWAX (AW), impression paste (IP) and Exabite II (EB). Analyses were conducted with the three-dimensional analyzer and calculated for the amount of vertical and antero-posterior displacement between the intraoral model and the working cast. The results were that PW had the greatest displacement, especially with the functional impression technique, while AW had minimum displacement especially in the posterior direction. With the functional impression technique utilizing AW was revealed to minimize the amount of interocclusal displacement.
PubMed: 12715920
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 002F72
- to stream PubMed, to step Curation: 002F72
- to stream PubMed, to step Checkpoint: 002F72
Links to Exploration step
pubmed:12715920Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Reproducibility of interocclusal recording for mandibular removable partial denture in bilateral distal extension cases.</title>
<author><name sortKey="Togano, Hiroshi" sort="Togano, Hiroshi" uniqKey="Togano H" first="Hiroshi" last="Togano">Hiroshi Togano</name>
<affiliation wicri:level="1"><nlm:affiliation>Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University</wicri:regionArea>
<wicri:noRegion>Tokyo Medical and Dental University</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Hideshima, Masayuki" sort="Hideshima, Masayuki" uniqKey="Hideshima M" first="Masayuki" last="Hideshima">Masayuki Hideshima</name>
</author>
<author><name sortKey="Ohyama, Takashi" sort="Ohyama, Takashi" uniqKey="Ohyama T" first="Takashi" last="Ohyama">Takashi Ohyama</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2003">2003</date>
<idno type="RBID">pubmed:12715920</idno>
<idno type="pmid">12715920</idno>
<idno type="wicri:Area/PubMed/Corpus">002F72</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002F72</idno>
<idno type="wicri:Area/PubMed/Curation">002F72</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">002F72</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002F72</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">002F72</idno>
<idno type="wicri:Area/Ncbi/Merge">000C42</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Reproducibility of interocclusal recording for mandibular removable partial denture in bilateral distal extension cases.</title>
<author><name sortKey="Togano, Hiroshi" sort="Togano, Hiroshi" uniqKey="Togano H" first="Hiroshi" last="Togano">Hiroshi Togano</name>
<affiliation wicri:level="1"><nlm:affiliation>Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University</wicri:regionArea>
<wicri:noRegion>Tokyo Medical and Dental University</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Hideshima, Masayuki" sort="Hideshima, Masayuki" uniqKey="Hideshima M" first="Masayuki" last="Hideshima">Masayuki Hideshima</name>
</author>
<author><name sortKey="Ohyama, Takashi" sort="Ohyama, Takashi" uniqKey="Ohyama T" first="Takashi" last="Ohyama">Takashi Ohyama</name>
</author>
</analytic>
<series><title level="j">Journal of medical and dental sciences</title>
<idno type="ISSN">1342-8810</idno>
<imprint><date when="2003" type="published">2003</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Analysis of Variance</term>
<term>Dental Impression Materials</term>
<term>Dental Impression Technique</term>
<term>Dental Models</term>
<term>Denture Design</term>
<term>Denture, Partial, Removable</term>
<term>Humans</term>
<term>Jaw Relation Record (methods)</term>
<term>Jaw, Edentulous, Partially (physiopathology)</term>
<term>Mandible</term>
<term>Polyvinyls</term>
<term>Reproducibility of Results</term>
<term>Siloxanes</term>
<term>Vertical Dimension</term>
<term>Waxes</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Analyse de variance</term>
<term>Cires</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Dimension verticale</term>
<term>Enregistrement des rapports intermaxillaires ()</term>
<term>Humains</term>
<term>Mandibule</term>
<term>Matériaux empreinte dentaire</term>
<term>Modèles dentaires</term>
<term>Mâchoire partiellement édentée (physiopathologie)</term>
<term>Polyvinyles</term>
<term>Prothèse dentaire partielle amovible</term>
<term>Reproductibilité des résultats</term>
<term>Siloxanes</term>
<term>Technique de prise d'empreinte</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Dental Impression Materials</term>
<term>Polyvinyls</term>
<term>Siloxanes</term>
<term>Waxes</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Jaw Relation Record</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr"><term>Mâchoire partiellement édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en"><term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Analysis of Variance</term>
<term>Dental Impression Technique</term>
<term>Dental Models</term>
<term>Denture Design</term>
<term>Denture, Partial, Removable</term>
<term>Humans</term>
<term>Mandible</term>
<term>Reproducibility of Results</term>
<term>Vertical Dimension</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Analyse de variance</term>
<term>Cires</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Dimension verticale</term>
<term>Enregistrement des rapports intermaxillaires</term>
<term>Humains</term>
<term>Mandibule</term>
<term>Matériaux empreinte dentaire</term>
<term>Modèles dentaires</term>
<term>Polyvinyles</term>
<term>Prothèse dentaire partielle amovible</term>
<term>Reproductibilité des résultats</term>
<term>Siloxanes</term>
<term>Technique de prise d'empreinte</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Interocclusal recording for removable partial denture in bilateral mandibular distal extension were evaluated for the differences of the interocclusal recording material utilized during different impression techniques. The purpose of this study is to develop interocclusal recording utilizing occlusion rims with high accuracy. The intraoral model with urethane rubber mucosa with 3 metallic spheres as measuring points was utilized. With the applied pressure (functional) and minimum pressure (anatomical) impression techniques, working casts were fabricated. Interocclusal recording was registered with the occlusion rim on the intraoral model unto the articulator by applying the interocclusal materials; paraffin wax (PW), ALUWAX (AW), impression paste (IP) and Exabite II (EB). Analyses were conducted with the three-dimensional analyzer and calculated for the amount of vertical and antero-posterior displacement between the intraoral model and the working cast. The results were that PW had the greatest displacement, especially with the functional impression technique, while AW had minimum displacement especially in the posterior direction. With the functional impression technique utilizing AW was revealed to minimize the amount of interocclusal displacement.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">12715920</PMID>
<DateCompleted><Year>2003</Year>
<Month>07</Month>
<Day>02</Day>
</DateCompleted>
<DateRevised><Year>2010</Year>
<Month>04</Month>
<Day>12</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">1342-8810</ISSN>
<JournalIssue CitedMedium="Print"><Volume>50</Volume>
<Issue>1</Issue>
<PubDate><Year>2003</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Journal of medical and dental sciences</Title>
<ISOAbbreviation>J. Med. Dent. Sci.</ISOAbbreviation>
</Journal>
<ArticleTitle>Reproducibility of interocclusal recording for mandibular removable partial denture in bilateral distal extension cases.</ArticleTitle>
<Pagination><MedlinePgn>53-61</MedlinePgn>
</Pagination>
<Abstract><AbstractText>Interocclusal recording for removable partial denture in bilateral mandibular distal extension were evaluated for the differences of the interocclusal recording material utilized during different impression techniques. The purpose of this study is to develop interocclusal recording utilizing occlusion rims with high accuracy. The intraoral model with urethane rubber mucosa with 3 metallic spheres as measuring points was utilized. With the applied pressure (functional) and minimum pressure (anatomical) impression techniques, working casts were fabricated. Interocclusal recording was registered with the occlusion rim on the intraoral model unto the articulator by applying the interocclusal materials; paraffin wax (PW), ALUWAX (AW), impression paste (IP) and Exabite II (EB). Analyses were conducted with the three-dimensional analyzer and calculated for the amount of vertical and antero-posterior displacement between the intraoral model and the working cast. The results were that PW had the greatest displacement, especially with the functional impression technique, while AW had minimum displacement especially in the posterior direction. With the functional impression technique utilizing AW was revealed to minimize the amount of interocclusal displacement.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Togano</LastName>
<ForeName>Hiroshi</ForeName>
<Initials>H</Initials>
<AffiliationInfo><Affiliation>Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Hideshima</LastName>
<ForeName>Masayuki</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y"><LastName>Ohyama</LastName>
<ForeName>Takashi</ForeName>
<Initials>T</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D023362">Evaluation Studies</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>Japan</Country>
<MedlineTA>J Med Dent Sci</MedlineTA>
<NlmUniqueID>9717112</NlmUniqueID>
<ISSNLinking>1342-8810</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003760">Dental Impression Materials</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011145">Polyvinyls</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012833">Siloxanes</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D014885">Waxes</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="C034183">vinyl polysiloxane</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000704" MajorTopicYN="N">Analysis of Variance</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003760" MajorTopicYN="Y">Dental Impression Materials</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003761" MajorTopicYN="Y">Dental Impression Technique</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003832" MajorTopicYN="Y">Denture, Partial, Removable</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007574" MajorTopicYN="N">Jaw Relation Record</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="Y">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011145" MajorTopicYN="N">Polyvinyls</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D012833" MajorTopicYN="N">Siloxanes</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014716" MajorTopicYN="N">Vertical Dimension</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014885" MajorTopicYN="N">Waxes</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>2003</Year>
<Month>4</Month>
<Day>29</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2003</Year>
<Month>7</Month>
<Day>3</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2003</Year>
<Month>4</Month>
<Day>29</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">12715920</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list><country><li>Japon</li>
</country>
</list>
<tree><noCountry><name sortKey="Hideshima, Masayuki" sort="Hideshima, Masayuki" uniqKey="Hideshima M" first="Masayuki" last="Hideshima">Masayuki Hideshima</name>
<name sortKey="Ohyama, Takashi" sort="Ohyama, Takashi" uniqKey="Ohyama T" first="Takashi" last="Ohyama">Takashi Ohyama</name>
</noCountry>
<country name="Japon"><noRegion><name sortKey="Togano, Hiroshi" sort="Togano, Hiroshi" uniqKey="Togano H" first="Hiroshi" last="Togano">Hiroshi Togano</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C42 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000C42 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Ncbi |étape= Merge |type= RBID |clé= pubmed:12715920 |texte= Reproducibility of interocclusal recording for mandibular removable partial denture in bilateral distal extension cases. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i -Sk "pubmed:12715920" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
![]() | This area was generated with Dilib version V0.6.32. | ![]() |