Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Clinical problems of computer-guided implant surgery

Identifieur interne : 006623 ( Ncbi/Curation ); précédent : 006622; suivant : 006624

Clinical problems of computer-guided implant surgery

Auteurs : Seong-Yong Moon [Corée du Sud] ; Kyoung-Rok Lee [Corée du Sud] ; Su-Gwan Kim [Corée du Sud] ; Mee-Kyoung Son [Corée du Sud]

Source :

RBID : PMC:4819455

Abstract

Background

The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement.

Methods

Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze differences of the implant fixture body between preoperative planned implant and postoperative placed implant, angular error and distance errors were evaluated.

Results

The mean angular errors between the preoperative planned and postoperative placed implant was 3.84° ± 1.49°; the mean distance errors between the planned and placed implants were 0.45 ± 0.48 mm horizontally and 0.63 ± 0.51 mm vertically at the implant neck and 0.70 ± 0.63 mm horizontally and 0.64 ± 0.57 mm vertically at the implant apex for all 19 implants.

Conclusions

It is important to be able to utilize these methods in actual clinical settings by improving the various problems, including the considerations of patient mouth opening limitations, surgical guide preparation, and fixation.


Url:
DOI: 10.1186/s40902-016-0063-3
PubMed: 27073797
PubMed Central: 4819455

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4819455

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Clinical problems of computer-guided implant surgery</title>
<author>
<name sortKey="Moon, Seong Yong" sort="Moon, Seong Yong" uniqKey="Moon S" first="Seong-Yong" last="Moon">Seong-Yong Moon</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Oral and Maxillofacial Surgery, School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Lee, Kyoung Rok" sort="Lee, Kyoung Rok" uniqKey="Lee K" first="Kyoung-Rok" last="Lee">Kyoung-Rok Lee</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff2">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Prosthodontics, Graduate School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Kim, Su Gwan" sort="Kim, Su Gwan" uniqKey="Kim S" first="Su-Gwan" last="Kim">Su-Gwan Kim</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Oral and Maxillofacial Surgery, School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Son, Mee Kyoung" sort="Son, Mee Kyoung" uniqKey="Son M" first="Mee-Kyoung" last="Son">Mee-Kyoung Son</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff3">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Prosthodontics, School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">27073797</idno>
<idno type="pmc">4819455</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4819455</idno>
<idno type="RBID">PMC:4819455</idno>
<idno type="doi">10.1186/s40902-016-0063-3</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">000D29</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000D29</idno>
<idno type="wicri:Area/Pmc/Curation">000D29</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000D29</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000835</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000835</idno>
<idno type="wicri:Area/Ncbi/Merge">006623</idno>
<idno type="wicri:Area/Ncbi/Curation">006623</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Clinical problems of computer-guided implant surgery</title>
<author>
<name sortKey="Moon, Seong Yong" sort="Moon, Seong Yong" uniqKey="Moon S" first="Seong-Yong" last="Moon">Seong-Yong Moon</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Oral and Maxillofacial Surgery, School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Lee, Kyoung Rok" sort="Lee, Kyoung Rok" uniqKey="Lee K" first="Kyoung-Rok" last="Lee">Kyoung-Rok Lee</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff2">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Prosthodontics, Graduate School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Kim, Su Gwan" sort="Kim, Su Gwan" uniqKey="Kim S" first="Su-Gwan" last="Kim">Su-Gwan Kim</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff1">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Oral and Maxillofacial Surgery, School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Son, Mee Kyoung" sort="Son, Mee Kyoung" uniqKey="Son M" first="Mee-Kyoung" last="Son">Mee-Kyoung Son</name>
<affiliation wicri:level="1">
<nlm:aff id="Aff3">
<institution-wrap>
<institution-id institution-id-type="GRID">grid.254187.d</institution-id>
<institution-id institution-id-type="ISNI">0000000094758840</institution-id>
<institution>Department of Prosthodontics, School of Dentistry,</institution>
<institution>Chosun University,</institution>
</institution-wrap>
375 Seosuk dong, Dong-gu, Gwangju, 501-759 South Korea</nlm:aff>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>375 Seosuk dong, Dong-gu, Gwangju</wicri:regionArea>
<wicri:noRegion>Gwangju</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Maxillofacial Plastic and Reconstructive Surgery</title>
<idno type="ISSN">2288-8101</idno>
<idno type="eISSN">2288-8586</idno>
<imprint>
<date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Background</title>
<p>The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement.</p>
</sec>
<sec>
<title>Methods</title>
<p>Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze differences of the implant fixture body between preoperative planned implant and postoperative placed implant, angular error and distance errors were evaluated. </p>
</sec>
<sec>
<title>Results</title>
<p>The mean angular errors between the preoperative planned and postoperative placed implant was 3.84° ± 1.49°; the mean distance errors between the planned and placed implants were 0.45 ± 0.48 mm horizontally and 0.63 ± 0.51 mm vertically at the implant neck and 0.70 ± 0.63 mm horizontally and 0.64 ± 0.57 mm vertically at the implant apex for all 19 implants.</p>
</sec>
<sec>
<title>Conclusions</title>
<p>It is important to be able to utilize these methods in actual clinical settings by improving the various problems, including the considerations of patient mouth opening limitations, surgical guide preparation, and fixation.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Jacobs, R" uniqKey="Jacobs R">R Jacobs</name>
</author>
<author>
<name sortKey="Adriansens, A" uniqKey="Adriansens A">A Adriansens</name>
</author>
<author>
<name sortKey="Verstreken, K" uniqKey="Verstreken K">K Verstreken</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Van Assche, N" uniqKey="Van Assche N">N Van Assche</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" uniqKey="Van Steenberghe D">D van Steenberghe</name>
</author>
<author>
<name sortKey="Guerrero, Me" uniqKey="Guerrero M">ME Guerrero</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Nickenig, H J" uniqKey="Nickenig H">H-J Nickenig</name>
</author>
<author>
<name sortKey="Eitner, S" uniqKey="Eitner S">S Eitner</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Klein, M" uniqKey="Klein M">M Klein</name>
</author>
<author>
<name sortKey="Abrams, M" uniqKey="Abrams M">M Abrams</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lee, J H" uniqKey="Lee J">J-H Lee</name>
</author>
<author>
<name sortKey="Kim, S M" uniqKey="Kim S">S-M Kim</name>
</author>
<author>
<name sortKey="Paeng, J Y" uniqKey="Paeng J">J-Y Paeng</name>
</author>
<author>
<name sortKey="Kim, M J" uniqKey="Kim M">M-J Kim</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Di Giacomo, Gap" uniqKey="Di Giacomo G">GAP Di Giacomo</name>
</author>
<author>
<name sortKey="Cury, Pr" uniqKey="Cury P">PR Cury</name>
</author>
<author>
<name sortKey="De Araujo, Ns" uniqKey="De Araujo N">NS de Araujo</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Schneider, D" uniqKey="Schneider D">D Schneider</name>
</author>
<author>
<name sortKey="Marquardt, P" uniqKey="Marquardt P">P Marquardt</name>
</author>
<author>
<name sortKey="Zwahlen, M" uniqKey="Zwahlen M">M Zwahlen</name>
</author>
<author>
<name sortKey="Jung, Re" uniqKey="Jung R">RE Jung</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kramer, F J" uniqKey="Kramer F">F-J Kramer</name>
</author>
<author>
<name sortKey="Baethge, C" uniqKey="Baethge C">C Baethge</name>
</author>
<author>
<name sortKey="Swennen, G" uniqKey="Swennen G">G Swennen</name>
</author>
<author>
<name sortKey="Rosahl, S" uniqKey="Rosahl S">S Rosahl</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hoffmann, J" uniqKey="Hoffmann J">J Hoffmann</name>
</author>
<author>
<name sortKey="Westendorff, C" uniqKey="Westendorff C">C Westendorff</name>
</author>
<author>
<name sortKey="Gomez Roman, G" uniqKey="Gomez Roman G">G Gomez-Roman</name>
</author>
<author>
<name sortKey="Reinert, S" uniqKey="Reinert S">S Reinert</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Nickenig, H J" uniqKey="Nickenig H">H-J Nickenig</name>
</author>
<author>
<name sortKey="Wichmann, M" uniqKey="Wichmann M">M Wichmann</name>
</author>
<author>
<name sortKey="Hamel, J" uniqKey="Hamel J">J Hamel</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ozan, O" uniqKey="Ozan O">O Ozan</name>
</author>
<author>
<name sortKey="Turkyilmaz, I" uniqKey="Turkyilmaz I">I Turkyilmaz</name>
</author>
<author>
<name sortKey="Ersoy, Ae" uniqKey="Ersoy A">AE Ersoy</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006623 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 006623 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Ncbi
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:4819455
   |texte=   Clinical problems of computer-guided implant surgery
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i   -Sk "pubmed:27073797" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022