Evaluation of dimensional accuracy of panoramic cross-sectional tomography, its ability to identify the inferior alveolar canal, and its impact on estimation of appropriate implant dimensions in the mandibular posterior region.
Identifieur interne : 002873 ( Ncbi/Curation ); précédent : 002872; suivant : 002874Evaluation of dimensional accuracy of panoramic cross-sectional tomography, its ability to identify the inferior alveolar canal, and its impact on estimation of appropriate implant dimensions in the mandibular posterior region.
Auteurs : Anshul Mehra [Inde] ; Keerthilatha M. PaiSource :
- Clinical implant dentistry and related research [ 1708-8208 ] ; 2012.
Descripteurs français
- KwdFr :
- Anatomie en coupes transversales, Biais de l'observateur, Cadavre, Conception de prothèse dentaire, Grossissement radiographique, Humains, Implants dentaires, Mandibule (anatomie et histologie), Mandibule (imagerie diagnostique), Marques de positionnement, Mâchoire partiellement édentée (imagerie diagnostique), Nerf mandibulaire (anatomie et histologie), Nerf mandibulaire (imagerie diagnostique), Normes de référence, Pose d'implant dentaire endo-osseux, Processus alvéolaire (imagerie diagnostique), Radiographie panoramique (), Reproductibilité des résultats, Tomographie à rayons X ().
- MESH :
- anatomie et histologie : Mandibule, Nerf mandibulaire.
- imagerie diagnostique : Mandibule, Mâchoire partiellement édentée, Nerf mandibulaire, Processus alvéolaire.
- Anatomie en coupes transversales, Biais de l'observateur, Cadavre, Conception de prothèse dentaire, Grossissement radiographique, Humains, Implants dentaires, Marques de positionnement, Normes de référence, Pose d'implant dentaire endo-osseux, Radiographie panoramique, Reproductibilité des résultats, Tomographie à rayons X.
English descriptors
- KwdEn :
- Alveolar Process (diagnostic imaging), Anatomy, Cross-Sectional, Cadaver, Dental Implantation, Endosseous, Dental Implants, Dental Prosthesis Design, Fiducial Markers, Humans, Jaw, Edentulous, Partially (diagnostic imaging), Mandible (anatomy & histology), Mandible (diagnostic imaging), Mandibular Nerve (anatomy & histology), Mandibular Nerve (diagnostic imaging), Observer Variation, Radiographic Magnification, Radiography, Panoramic (methods), Reference Standards, Reproducibility of Results, Tomography, X-Ray (methods).
- MESH :
- chemical : Dental Implants.
- anatomy & histology : Mandible, Mandibular Nerve.
- diagnostic imaging : Alveolar Process, Jaw, Edentulous, Partially, Mandible, Mandibular Nerve.
- methods : Radiography, Panoramic, Tomography, X-Ray.
- Anatomy, Cross-Sectional, Cadaver, Dental Implantation, Endosseous, Dental Prosthesis Design, Fiducial Markers, Humans, Observer Variation, Radiographic Magnification, Reference Standards, Reproducibility of Results.
Abstract
To evaluate the dimensional accuracy of panoramic cross-sectional tomography, its impact on implant size estimation and its ability in identifying the inferior alveolar canal in the mandibular posterior region.
DOI: 10.1111/j.1708-8208.2009.00226.x
PubMed: 19673959
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :001235
- to stream PubMed, to step Curation: Pour aller vers cette notice dans l'étape Curation :001235
- to stream PubMed, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :001235
- to stream Ncbi, to step Merge: Pour aller vers cette notice dans l'étape Curation :002873
Links to Exploration step
pubmed:19673959Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Evaluation of dimensional accuracy of panoramic cross-sectional tomography, its ability to identify the inferior alveolar canal, and its impact on estimation of appropriate implant dimensions in the mandibular posterior region.</title>
<author><name sortKey="Mehra, Anshul" sort="Mehra, Anshul" uniqKey="Mehra A" first="Anshul" last="Mehra">Anshul Mehra</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Oral Medicine and Radiology, U.P. Dental College and Research Centre, Faizabad Road, Lucknow, Uttar Pradesh, India. mehraanshul@yahoo.co.in</nlm:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Oral Medicine and Radiology, U.P. Dental College and Research Centre, Faizabad Road, Lucknow, Uttar Pradesh</wicri:regionArea>
<wicri:noRegion>Uttar Pradesh</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Pai, Keerthilatha M" sort="Pai, Keerthilatha M" uniqKey="Pai K" first="Keerthilatha M" last="Pai">Keerthilatha M. Pai</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:19673959</idno>
<idno type="pmid">19673959</idno>
<idno type="doi">10.1111/j.1708-8208.2009.00226.x</idno>
<idno type="wicri:Area/PubMed/Corpus">001235</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001235</idno>
<idno type="wicri:Area/PubMed/Curation">001235</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">001235</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001235</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">001235</idno>
<idno type="wicri:Area/Ncbi/Merge">002873</idno>
<idno type="wicri:Area/Ncbi/Curation">002873</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Evaluation of dimensional accuracy of panoramic cross-sectional tomography, its ability to identify the inferior alveolar canal, and its impact on estimation of appropriate implant dimensions in the mandibular posterior region.</title>
<author><name sortKey="Mehra, Anshul" sort="Mehra, Anshul" uniqKey="Mehra A" first="Anshul" last="Mehra">Anshul Mehra</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Oral Medicine and Radiology, U.P. Dental College and Research Centre, Faizabad Road, Lucknow, Uttar Pradesh, India. mehraanshul@yahoo.co.in</nlm:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Oral Medicine and Radiology, U.P. Dental College and Research Centre, Faizabad Road, Lucknow, Uttar Pradesh</wicri:regionArea>
<wicri:noRegion>Uttar Pradesh</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Pai, Keerthilatha M" sort="Pai, Keerthilatha M" uniqKey="Pai K" first="Keerthilatha M" last="Pai">Keerthilatha M. Pai</name>
</author>
</analytic>
<series><title level="j">Clinical implant dentistry and related research</title>
<idno type="eISSN">1708-8208</idno>
<imprint><date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Alveolar Process (diagnostic imaging)</term>
<term>Anatomy, Cross-Sectional</term>
<term>Cadaver</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>Fiducial Markers</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (diagnostic imaging)</term>
<term>Mandible (anatomy & histology)</term>
<term>Mandible (diagnostic imaging)</term>
<term>Mandibular Nerve (anatomy & histology)</term>
<term>Mandibular Nerve (diagnostic imaging)</term>
<term>Observer Variation</term>
<term>Radiographic Magnification</term>
<term>Radiography, Panoramic (methods)</term>
<term>Reference Standards</term>
<term>Reproducibility of Results</term>
<term>Tomography, X-Ray (methods)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Anatomie en coupes transversales</term>
<term>Biais de l'observateur</term>
<term>Cadavre</term>
<term>Conception de prothèse dentaire</term>
<term>Grossissement radiographique</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Mandibule (anatomie et histologie)</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Marques de positionnement</term>
<term>Mâchoire partiellement édentée (imagerie diagnostique)</term>
<term>Nerf mandibulaire (anatomie et histologie)</term>
<term>Nerf mandibulaire (imagerie diagnostique)</term>
<term>Normes de référence</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Processus alvéolaire (imagerie diagnostique)</term>
<term>Radiographie panoramique ()</term>
<term>Reproductibilité des résultats</term>
<term>Tomographie à rayons X ()</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomie et histologie" xml:lang="fr"><term>Mandibule</term>
<term>Nerf mandibulaire</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomy & histology" xml:lang="en"><term>Mandible</term>
<term>Mandibular Nerve</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en"><term>Alveolar Process</term>
<term>Jaw, Edentulous, Partially</term>
<term>Mandible</term>
<term>Mandibular Nerve</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr"><term>Mandibule</term>
<term>Mâchoire partiellement édentée</term>
<term>Nerf mandibulaire</term>
<term>Processus alvéolaire</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Radiography, Panoramic</term>
<term>Tomography, X-Ray</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Anatomy, Cross-Sectional</term>
<term>Cadaver</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Design</term>
<term>Fiducial Markers</term>
<term>Humans</term>
<term>Observer Variation</term>
<term>Radiographic Magnification</term>
<term>Reference Standards</term>
<term>Reproducibility of Results</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Anatomie en coupes transversales</term>
<term>Biais de l'observateur</term>
<term>Cadavre</term>
<term>Conception de prothèse dentaire</term>
<term>Grossissement radiographique</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Marques de positionnement</term>
<term>Normes de référence</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie panoramique</term>
<term>Reproductibilité des résultats</term>
<term>Tomographie à rayons X</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To evaluate the dimensional accuracy of panoramic cross-sectional tomography, its impact on implant size estimation and its ability in identifying the inferior alveolar canal in the mandibular posterior region.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002873 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 002873 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Ncbi |étape= Curation |type= RBID |clé= pubmed:19673959 |texte= Evaluation of dimensional accuracy of panoramic cross-sectional tomography, its ability to identify the inferior alveolar canal, and its impact on estimation of appropriate implant dimensions in the mandibular posterior region. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i -Sk "pubmed:19673959" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
![]() | This area was generated with Dilib version V0.6.32. | ![]() |