Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and reproducibility of the technique in quantitative densitometric measurements of the mandible in vivo.

Identifieur interne : 000475 ( Ncbi/Curation ); précédent : 000474; suivant : 000476

Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and reproducibility of the technique in quantitative densitometric measurements of the mandible in vivo.

Auteurs : J W Verhoeven [Pays-Bas] ; J. Ruijter ; M S Cune ; M. Terlou

Source :

RBID : pubmed:11168240

Descripteurs français

English descriptors

Abstract

In the literature intraoral periapical radiographs are commonly used for densitometric measurements of the mandible with implants. These films give detailed information of the implant and the surrounding bone. However, in extreme mandibular atrophy it can be difficult to obtain intraoral radiographs of adequate diagnostic quality. Extraoral Oblique Lateral Cephalometric Radiographs (OLCRs) can then be the alternative: reproducible images of large parts of the mandible can be obtained. In vitro, the results of densitometry using periapical films and OLCRs were shown to be similar. The present study aims to determine the measurement error of densitometry with OLCRs in vivo. In 16 patients (group I) with atrophic mandible and implants, duplicate OLCRs of one side of the jaw were obtained. The error of measurement for the densitometric measurements of the mandibular bone was 5.5%. The use of a specially developed correction program to compensate for undesired variations in the projection of the soft tissues of the face (tongue, lips, cheek and neck) on the radiographs resulted in a 40% reduction of that measurement error to 3.5%. This remaining error is mainly brought about by an imperfect repositioning of the patient when the duplicate OLCRs are obtained. The error caused by the image acquisition, processing and measurement is less than 1%. Deliberate variation up to 7.5 degrees of the horizontal angle wherein the OLCRs are made, results in a large error of measurement of 13.5% (group II: 17 patients). To reduce this variation the additional soft tissue correction program is unsuitable. It is concluded from this study that the described radiographic and image analysis technique is a promising tool for prospective densitometric studies of the mandible with or without implants. Especially in mandibles with bone grafts and implants, substantial changes in the graft can occur. The described technique may be particularly valuable in analyzing these changes.

PubMed: 11168240

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:11168240

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and reproducibility of the technique in quantitative densitometric measurements of the mandible in vivo.</title>
<author>
<name sortKey="Verhoeven, J W" sort="Verhoeven, J W" uniqKey="Verhoeven J" first="J W" last="Verhoeven">J W Verhoeven</name>
<affiliation wicri:level="4">
<nlm:affiliation>Utrecht University, Department of Oral & Maxillofacial Surgery, Prosthodontics and Special Dental Care, PO Box 80.037, 3508 TA Utrecht, The Netherlands.</nlm:affiliation>
<country xml:lang="fr">Pays-Bas</country>
<wicri:regionArea>Utrecht University, Department of Oral & Maxillofacial Surgery, Prosthodontics and Special Dental Care, PO Box 80.037, 3508 TA Utrecht</wicri:regionArea>
<orgName type="university">Université d'Utrecht</orgName>
<placeName>
<settlement type="city">Utrecht</settlement>
<region nuts="2">Utrecht (province)</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Ruijter, J" sort="Ruijter, J" uniqKey="Ruijter J" first="J" last="Ruijter">J. Ruijter</name>
</author>
<author>
<name sortKey="Cune, M S" sort="Cune, M S" uniqKey="Cune M" first="M S" last="Cune">M S Cune</name>
</author>
<author>
<name sortKey="Terlou, M" sort="Terlou, M" uniqKey="Terlou M" first="M" last="Terlou">M. Terlou</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2000">2000</date>
<idno type="RBID">pubmed:11168240</idno>
<idno type="pmid">11168240</idno>
<idno type="wicri:Area/PubMed/Corpus">003631</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">003631</idno>
<idno type="wicri:Area/PubMed/Curation">003631</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">003631</idno>
<idno type="wicri:Area/PubMed/Checkpoint">003631</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">003631</idno>
<idno type="wicri:Area/Ncbi/Merge">000475</idno>
<idno type="wicri:Area/Ncbi/Curation">000475</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and reproducibility of the technique in quantitative densitometric measurements of the mandible in vivo.</title>
<author>
<name sortKey="Verhoeven, J W" sort="Verhoeven, J W" uniqKey="Verhoeven J" first="J W" last="Verhoeven">J W Verhoeven</name>
<affiliation wicri:level="4">
<nlm:affiliation>Utrecht University, Department of Oral & Maxillofacial Surgery, Prosthodontics and Special Dental Care, PO Box 80.037, 3508 TA Utrecht, The Netherlands.</nlm:affiliation>
<country xml:lang="fr">Pays-Bas</country>
<wicri:regionArea>Utrecht University, Department of Oral & Maxillofacial Surgery, Prosthodontics and Special Dental Care, PO Box 80.037, 3508 TA Utrecht</wicri:regionArea>
<orgName type="university">Université d'Utrecht</orgName>
<placeName>
<settlement type="city">Utrecht</settlement>
<region nuts="2">Utrecht (province)</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Ruijter, J" sort="Ruijter, J" uniqKey="Ruijter J" first="J" last="Ruijter">J. Ruijter</name>
</author>
<author>
<name sortKey="Cune, M S" sort="Cune, M S" uniqKey="Cune M" first="M S" last="Cune">M S Cune</name>
</author>
<author>
<name sortKey="Terlou, M" sort="Terlou, M" uniqKey="Terlou M" first="M" last="Terlou">M. Terlou</name>
</author>
</analytic>
<series>
<title level="j">Clinical oral implants research</title>
<idno type="ISSN">0905-7161</idno>
<imprint>
<date when="2000" type="published">2000</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aluminum</term>
<term>Alveolar Bone Loss (diagnostic imaging)</term>
<term>Analysis of Variance</term>
<term>Bone Density</term>
<term>Cephalometry (methods)</term>
<term>Densitometry (methods)</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Implants</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Mandible (diagnostic imaging)</term>
<term>Phantoms, Imaging</term>
<term>Radiographic Image Enhancement</term>
<term>Radiographic Image Interpretation, Computer-Assisted</term>
<term>Reference Values</term>
<term>Reproducibility of Results</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Aluminium</term>
<term>Amélioration d'image radiographique</term>
<term>Analyse de variance</term>
<term>Céphalométrie ()</term>
<term>Densitométrie ()</term>
<term>Densité osseuse</term>
<term>Fantômes en imagerie</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Interprétation de radiographie assistée par ordinateur</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Reproductibilité des résultats</term>
<term>Résorption alvéolaire (imagerie diagnostique)</term>
<term>Valeurs de référence</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Aluminum</term>
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Alveolar Bone Loss</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mandibule</term>
<term>Mâchoire édentée</term>
<term>Résorption alvéolaire</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Cephalometry</term>
<term>Densitometry</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Analysis of Variance</term>
<term>Bone Density</term>
<term>Dental Implantation, Endosseous</term>
<term>Humans</term>
<term>Phantoms, Imaging</term>
<term>Radiographic Image Enhancement</term>
<term>Radiographic Image Interpretation, Computer-Assisted</term>
<term>Reference Values</term>
<term>Reproducibility of Results</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Aluminium</term>
<term>Amélioration d'image radiographique</term>
<term>Analyse de variance</term>
<term>Céphalométrie</term>
<term>Densitométrie</term>
<term>Densité osseuse</term>
<term>Fantômes en imagerie</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Interprétation de radiographie assistée par ordinateur</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Reproductibilité des résultats</term>
<term>Valeurs de référence</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In the literature intraoral periapical radiographs are commonly used for densitometric measurements of the mandible with implants. These films give detailed information of the implant and the surrounding bone. However, in extreme mandibular atrophy it can be difficult to obtain intraoral radiographs of adequate diagnostic quality. Extraoral Oblique Lateral Cephalometric Radiographs (OLCRs) can then be the alternative: reproducible images of large parts of the mandible can be obtained. In vitro, the results of densitometry using periapical films and OLCRs were shown to be similar. The present study aims to determine the measurement error of densitometry with OLCRs in vivo. In 16 patients (group I) with atrophic mandible and implants, duplicate OLCRs of one side of the jaw were obtained. The error of measurement for the densitometric measurements of the mandibular bone was 5.5%. The use of a specially developed correction program to compensate for undesired variations in the projection of the soft tissues of the face (tongue, lips, cheek and neck) on the radiographs resulted in a 40% reduction of that measurement error to 3.5%. This remaining error is mainly brought about by an imperfect repositioning of the patient when the duplicate OLCRs are obtained. The error caused by the image acquisition, processing and measurement is less than 1%. Deliberate variation up to 7.5 degrees of the horizontal angle wherein the OLCRs are made, results in a large error of measurement of 13.5% (group II: 17 patients). To reduce this variation the additional soft tissue correction program is unsuitable. It is concluded from this study that the described radiographic and image analysis technique is a promising tool for prospective densitometric studies of the mandible with or without implants. Especially in mandibles with bone grafts and implants, substantial changes in the graft can occur. The described technique may be particularly valuable in analyzing these changes.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000475 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 000475 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Ncbi
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:11168240
   |texte=   Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and reproducibility of the technique in quantitative densitometric measurements of the mandible in vivo.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i   -Sk "pubmed:11168240" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022