Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial

Identifieur interne : 006927 ( Ncbi/Checkpoint ); précédent : 006926; suivant : 006928

Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial

Auteurs : Ulf Schepke ; Henny J. A. Meijer ; Wouter Kerdijk ; Gerry M. Raghoebar ; Marco Cune

Source :

RBID : PMC:5297995

Abstract

AbstractBackground

Single‐tooth replacement often requires a prefabricated dental implant and a customized crown. The benefits of individualization of the abutment remain unclear.

Purpose

This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level and several clinical and patient‐based outcome measures.

Material and Methods

Fifty participants with a missing premolar were included and randomly assigned to standard (ZirDesign, DentsplySirona Implants, Mölndal, Sweden) or computer aided design/computer aided manufacturing (CAD/CAM) customized (Atlantis, DentsplySirona Implants, Mölndal, Sweden) zirconia abutment therapy. Peri‐implant bone level (primary outcome), Plaque‐index, calculus formation, bleeding on probing, gingiva index, probing pocket depth, recession, appearance of soft tissues and patients' contentment were assessed shortly after placement and one year later.

Results

No implants were lost and no complications related to the abutments were observed. Statistically significant differences between stock and CAD/CAM customized zirconia abutments could not be demonstrated for any of the operationalized variables.

Conclusion

The use of a CAD/CAM customized zirconia abutment in single tooth replacement of a premolar is not associated with an improvement in clinical performance or patients' contentment when compared to the use of a stock zirconia abutment.


Url:
DOI: 10.1111/cid.12440
PubMed: 27476829
PubMed Central: 5297995


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:5297995

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial</title>
<author>
<name sortKey="Schepke, Ulf" sort="Schepke, Ulf" uniqKey="Schepke U" first="Ulf" last="Schepke">Ulf Schepke</name>
<affiliation>
<nlm:aff id="cid12440-aff-0001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Meijer, Henny J A" sort="Meijer, Henny J A" uniqKey="Meijer H" first="Henny J. A." last="Meijer">Henny J. A. Meijer</name>
<affiliation>
<nlm:aff id="cid12440-aff-0002"></nlm:aff>
</affiliation>
<affiliation>
<nlm:aff id="cid12440-aff-0003"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Kerdijk, Wouter" sort="Kerdijk, Wouter" uniqKey="Kerdijk W" first="Wouter" last="Kerdijk">Wouter Kerdijk</name>
<affiliation>
<nlm:aff id="cid12440-aff-0004"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Raghoebar, Gerry M" sort="Raghoebar, Gerry M" uniqKey="Raghoebar G" first="Gerry M." last="Raghoebar">Gerry M. Raghoebar</name>
<affiliation>
<nlm:aff id="cid12440-aff-0003"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Cune, Marco" sort="Cune, Marco" uniqKey="Cune M" first="Marco" last="Cune">Marco Cune</name>
<affiliation>
<nlm:aff id="cid12440-aff-0002"></nlm:aff>
</affiliation>
<affiliation>
<nlm:aff id="cid12440-aff-0005"></nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">27476829</idno>
<idno type="pmc">5297995</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5297995</idno>
<idno type="RBID">PMC:5297995</idno>
<idno type="doi">10.1111/cid.12440</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">002B02</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002B02</idno>
<idno type="wicri:Area/Pmc/Curation">002B02</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">002B02</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000443</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000443</idno>
<idno type="wicri:Area/Ncbi/Merge">006927</idno>
<idno type="wicri:Area/Ncbi/Curation">006927</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">006927</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial</title>
<author>
<name sortKey="Schepke, Ulf" sort="Schepke, Ulf" uniqKey="Schepke U" first="Ulf" last="Schepke">Ulf Schepke</name>
<affiliation>
<nlm:aff id="cid12440-aff-0001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Meijer, Henny J A" sort="Meijer, Henny J A" uniqKey="Meijer H" first="Henny J. A." last="Meijer">Henny J. A. Meijer</name>
<affiliation>
<nlm:aff id="cid12440-aff-0002"></nlm:aff>
</affiliation>
<affiliation>
<nlm:aff id="cid12440-aff-0003"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Kerdijk, Wouter" sort="Kerdijk, Wouter" uniqKey="Kerdijk W" first="Wouter" last="Kerdijk">Wouter Kerdijk</name>
<affiliation>
<nlm:aff id="cid12440-aff-0004"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Raghoebar, Gerry M" sort="Raghoebar, Gerry M" uniqKey="Raghoebar G" first="Gerry M." last="Raghoebar">Gerry M. Raghoebar</name>
<affiliation>
<nlm:aff id="cid12440-aff-0003"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Cune, Marco" sort="Cune, Marco" uniqKey="Cune M" first="Marco" last="Cune">Marco Cune</name>
<affiliation>
<nlm:aff id="cid12440-aff-0002"></nlm:aff>
</affiliation>
<affiliation>
<nlm:aff id="cid12440-aff-0005"></nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Clinical Implant Dentistry and Related Research</title>
<idno type="ISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<imprint>
<date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<title>Abstract</title>
<sec id="cid12440-sec-0001">
<title>Background</title>
<p>Single‐tooth replacement often requires a prefabricated dental implant and a customized crown. The benefits of individualization of the abutment remain unclear.</p>
</sec>
<sec id="cid12440-sec-0002">
<title>Purpose</title>
<p>This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level and several clinical and patient‐based outcome measures.</p>
</sec>
<sec id="cid12440-sec-0003">
<title>Material and Methods</title>
<p>Fifty participants with a missing premolar were included and randomly assigned to standard (ZirDesign, DentsplySirona Implants, Mölndal, Sweden) or computer aided design/computer aided manufacturing (CAD/CAM) customized (Atlantis, DentsplySirona Implants, Mölndal, Sweden) zirconia abutment therapy. Peri‐implant bone level (primary outcome), Plaque‐index, calculus formation, bleeding on probing, gingiva index, probing pocket depth, recession, appearance of soft tissues and patients' contentment were assessed shortly after placement and one year later.</p>
</sec>
<sec id="cid12440-sec-0004">
<title>Results</title>
<p>No implants were lost and no complications related to the abutments were observed. Statistically significant differences between stock and CAD/CAM customized zirconia abutments could not be demonstrated for any of the operationalized variables.</p>
</sec>
<sec id="cid12440-sec-0005">
<title>Conclusion</title>
<p>The use of a CAD/CAM customized zirconia abutment in single tooth replacement of a premolar is not associated with an improvement in clinical performance or patients' contentment when compared to the use of a stock zirconia abutment.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Cune, Marco" sort="Cune, Marco" uniqKey="Cune M" first="Marco" last="Cune">Marco Cune</name>
<name sortKey="Kerdijk, Wouter" sort="Kerdijk, Wouter" uniqKey="Kerdijk W" first="Wouter" last="Kerdijk">Wouter Kerdijk</name>
<name sortKey="Meijer, Henny J A" sort="Meijer, Henny J A" uniqKey="Meijer H" first="Henny J. A." last="Meijer">Henny J. A. Meijer</name>
<name sortKey="Raghoebar, Gerry M" sort="Raghoebar, Gerry M" uniqKey="Raghoebar G" first="Gerry M." last="Raghoebar">Gerry M. Raghoebar</name>
<name sortKey="Schepke, Ulf" sort="Schepke, Ulf" uniqKey="Schepke U" first="Ulf" last="Schepke">Ulf Schepke</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Ncbi/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006927 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd -nk 006927 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Ncbi
   |étape=   Checkpoint
   |type=    RBID
   |clé=     PMC:5297995
   |texte=   Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/RBID.i   -Sk "pubmed:27476829" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022