Reaction of the anterior abutment of a Kennedy Class II removable partial denture to various clasp arm designs: an in vitro study.
Identifieur interne : 00D217 ( Main/Merge ); précédent : 00D216; suivant : 00D218Reaction of the anterior abutment of a Kennedy Class II removable partial denture to various clasp arm designs: an in vitro study.
Auteurs : D N Firtell ; R J Grisius ; A M MuncheryanSource :
- The Journal of prosthetic dentistry [ 0022-3913 ] ; 1985.
Descripteurs français
- KwdFr :
- MESH :
English descriptors
- KwdEn :
- MESH :
- classification : Jaw, Edentulous, Partially.
- physiology : Tooth.
- Dental Abutments, Dental Stress Analysis, Denture Design, Denture Retention, Denture, Partial, Removable, Humans, Models, Anatomic.
Abstract
Five clasp arm designs were selected for in vitro testing of the anterior abutment of a Kennedy Class II removable partial denture. The clasps were a circumferential clasp with the cast retentive arm placed at the survey line, a circumferential clasp with a cast retentive arm placed into a mesiofacial undercut of 0.01 inch, a circumferential clasp with a wrought wire retentive arm placed into a mesiofacial undercut of 0.01 inch, a buccal I-bar placed at the greatest facial curvature into a 0.01 inch undercut, and a half T-bar buccal arm placed into a 0.01 inch distofacial undercut. The relative movement of the abutments was recorded by a polygraph on a line from a point of force in the extension and through the rest seat of the anterior abutment, 90 degrees from the first direction, and vertically in the long axis of the abutment. The amount of movement of the abutment tested varied relative to the clasp design and the directions recorded. The cast circumferential arm placed at the survey line consistently showed less movement, and a cast circumferential arm placed into an undercut showed the greatest total movement. The decision to use any of these clasp arm designs should be correlated with other clinical conditions that are present for a specific patient.
PubMed: 3882953
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 005705
- to stream PubMed, to step Curation: 005705
- to stream PubMed, to step Checkpoint: 005705
- to stream Ncbi, to step Merge: 007C84
- to stream Ncbi, to step Curation: 007C84
- to stream Ncbi, to step Checkpoint: 007C84
Links to Exploration step
pubmed:3882953Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Reaction of the anterior abutment of a Kennedy Class II removable partial denture to various clasp arm designs: an in vitro study.</title>
<author><name sortKey="Firtell, D N" sort="Firtell, D N" uniqKey="Firtell D" first="D N" last="Firtell">D N Firtell</name>
</author>
<author><name sortKey="Grisius, R J" sort="Grisius, R J" uniqKey="Grisius R" first="R J" last="Grisius">R J Grisius</name>
</author>
<author><name sortKey="Muncheryan, A M" sort="Muncheryan, A M" uniqKey="Muncheryan A" first="A M" last="Muncheryan">A M Muncheryan</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1985">1985</date>
<idno type="RBID">pubmed:3882953</idno>
<idno type="pmid">3882953</idno>
<idno type="wicri:Area/PubMed/Corpus">005705</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">005705</idno>
<idno type="wicri:Area/PubMed/Curation">005705</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">005705</idno>
<idno type="wicri:Area/PubMed/Checkpoint">005705</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">005705</idno>
<idno type="wicri:Area/Ncbi/Merge">007C84</idno>
<idno type="wicri:Area/Ncbi/Curation">007C84</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">007C84</idno>
<idno type="wicri:doubleKey">0022-3913:1985:Firtell D:reaction:of:the</idno>
<idno type="wicri:Area/Main/Merge">00D217</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Reaction of the anterior abutment of a Kennedy Class II removable partial denture to various clasp arm designs: an in vitro study.</title>
<author><name sortKey="Firtell, D N" sort="Firtell, D N" uniqKey="Firtell D" first="D N" last="Firtell">D N Firtell</name>
</author>
<author><name sortKey="Grisius, R J" sort="Grisius, R J" uniqKey="Grisius R" first="R J" last="Grisius">R J Grisius</name>
</author>
<author><name sortKey="Muncheryan, A M" sort="Muncheryan, A M" uniqKey="Muncheryan A" first="A M" last="Muncheryan">A M Muncheryan</name>
</author>
</analytic>
<series><title level="j">The Journal of prosthetic dentistry</title>
<idno type="ISSN">0022-3913</idno>
<imprint><date when="1985" type="published">1985</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Dental Abutments</term>
<term>Dental Stress Analysis</term>
<term>Denture Design</term>
<term>Denture Retention</term>
<term>Denture, Partial, Removable</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (classification)</term>
<term>Models, Anatomic</term>
<term>Tooth (physiology)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Analyse du stress dentaire</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Dent (physiologie)</term>
<term>Humains</term>
<term>Modèles anatomiques</term>
<term>Mâchoire partiellement édentée ()</term>
<term>Piliers dentaires</term>
<term>Prothèse dentaire partielle amovible</term>
<term>Rétention d'appareil de prothèse dentaire</term>
</keywords>
<keywords scheme="MESH" qualifier="classification" xml:lang="en"><term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="physiologie" xml:lang="fr"><term>Dent</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en"><term>Tooth</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Dental Abutments</term>
<term>Dental Stress Analysis</term>
<term>Denture Design</term>
<term>Denture Retention</term>
<term>Denture, Partial, Removable</term>
<term>Humans</term>
<term>Models, Anatomic</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Analyse du stress dentaire</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Humains</term>
<term>Modèles anatomiques</term>
<term>Mâchoire partiellement édentée</term>
<term>Piliers dentaires</term>
<term>Prothèse dentaire partielle amovible</term>
<term>Rétention d'appareil de prothèse dentaire</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Five clasp arm designs were selected for in vitro testing of the anterior abutment of a Kennedy Class II removable partial denture. The clasps were a circumferential clasp with the cast retentive arm placed at the survey line, a circumferential clasp with a cast retentive arm placed into a mesiofacial undercut of 0.01 inch, a circumferential clasp with a wrought wire retentive arm placed into a mesiofacial undercut of 0.01 inch, a buccal I-bar placed at the greatest facial curvature into a 0.01 inch undercut, and a half T-bar buccal arm placed into a 0.01 inch distofacial undercut. The relative movement of the abutments was recorded by a polygraph on a line from a point of force in the extension and through the rest seat of the anterior abutment, 90 degrees from the first direction, and vertically in the long axis of the abutment. The amount of movement of the abutment tested varied relative to the clasp design and the directions recorded. The cast circumferential arm placed at the survey line consistently showed less movement, and a cast circumferential arm placed into an undercut showed the greatest total movement. The decision to use any of these clasp arm designs should be correlated with other clinical conditions that are present for a specific patient.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00D217 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 00D217 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Merge |type= RBID |clé= pubmed:3882953 |texte= Reaction of the anterior abutment of a Kennedy Class II removable partial denture to various clasp arm designs: an in vitro study. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i -Sk "pubmed:3882953" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
![]() | This area was generated with Dilib version V0.6.32. | ![]() |