Accuracy of mechanical torque‐limiting gauges for mini‐screw placement
Identifieur interne : 005502 ( Main/Merge ); précédent : 005501; suivant : 005503Accuracy of mechanical torque‐limiting gauges for mini‐screw placement
Auteurs : Marc Sch Tzle [Suisse, République populaire de Chine] ; Dorota Golland [Suisse] ; Malgorzata Roos [Suisse] ; Bogna Stawarczyk [Suisse]Source :
- Clinical Oral Implants Research [ 0905-7161 ] ; 2010-08.
Descripteurs français
- Wicri :
- topic : Stérilisation.
English descriptors
- KwdEn :
- Absoanchor, Anchorage, Breakpoint, Breakpoint value, Breakpoint values, Breakpoints, Breakpoints values, Clin, Clinical orthodontics, Dentistry, Dentofacial orthopedics, Early failure, Impl, Implant, Implant dentistry, Implants research, Insertion, Insertion torque, International journal, John wiley sons, Lomas, Marc scha, Measurement error, Mini, Mini anchor system, Mtlg, Mtlgs, Oral impl, Oral medicine, Orthodontic anchorage, Orthodontic treatment, Orthodontics, Placement table, Primary stability, Scha, Screwdriver, Serror, Spider, Spider screw, Spider screw mtlg, Sterilisation, Sterilisation process, Sterilisation torque screw level, Target torque values, Tomas, Torque, Torque control, Torque level, Torque output, Torque values, Tzle, Variance.
- Teeft :
- Absoanchor, Anchorage, Breakpoint, Breakpoint value, Breakpoint values, Breakpoints, Breakpoints values, Clin, Clinical orthodontics, Dentistry, Dentofacial orthopedics, Early failure, Impl, Implant, Implant dentistry, Implants research, Insertion, Insertion torque, International journal, John wiley sons, Lomas, Marc scha, Measurement error, Mini, Mini anchor system, Mtlg, Mtlgs, Oral impl, Oral medicine, Orthodontic anchorage, Orthodontic treatment, Orthodontics, Placement table, Primary stability, Scha, Screwdriver, Serror, Spider, Spider screw, Spider screw mtlg, Sterilisation, Sterilisation process, Sterilisation torque screw level, Target torque values, Tomas, Torque, Torque control, Torque level, Torque output, Torque values, Tzle, Variance.
Abstract
Aim: The purpose of this investigation was to determine and compare the accuracy of four available mechanical torque‐limiting gauges (MTLGs) for mini‐screw placement.
Url:
DOI: 10.1111/j.1600-0501.2010.01927.x
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 005B16
- to stream Istex, to step Curation: 005B16
- to stream Istex, to step Checkpoint: 001F63
Links to Exploration step
ISTEX:B6F2B296F9007F3B0B2A0DD0FD83CE83BE9587BFLe document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Accuracy of mechanical torque‐limiting gauges for mini‐screw placement</title>
<author><name sortKey="Sch Tzle, Marc" sort="Sch Tzle, Marc" uniqKey="Sch Tzle M" first="Marc" last="Sch Tzle">Marc Sch Tzle</name>
</author>
<author><name sortKey="Golland, Dorota" sort="Golland, Dorota" uniqKey="Golland D" first="Dorota" last="Golland">Dorota Golland</name>
</author>
<author><name sortKey="Roos, Malgorzata" sort="Roos, Malgorzata" uniqKey="Roos M" first="Malgorzata" last="Roos">Malgorzata Roos</name>
</author>
<author><name sortKey="Stawarczyk, Bogna" sort="Stawarczyk, Bogna" uniqKey="Stawarczyk B" first="Bogna" last="Stawarczyk">Bogna Stawarczyk</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:B6F2B296F9007F3B0B2A0DD0FD83CE83BE9587BF</idno>
<date when="2010" year="2010">2010</date>
<idno type="doi">10.1111/j.1600-0501.2010.01927.x</idno>
<idno type="url">https://api.istex.fr/document/B6F2B296F9007F3B0B2A0DD0FD83CE83BE9587BF/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">005B16</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">005B16</idno>
<idno type="wicri:Area/Istex/Curation">005B16</idno>
<idno type="wicri:Area/Istex/Checkpoint">001F63</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001F63</idno>
<idno type="wicri:doubleKey">0905-7161:2010:Sch Tzle M:accuracy:of:mechanical</idno>
<idno type="wicri:Area/Main/Merge">005502</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">Accuracy of mechanical torque‐limiting gauges for mini‐screw placement</title>
<author><name sortKey="Sch Tzle, Marc" sort="Sch Tzle, Marc" uniqKey="Sch Tzle M" first="Marc" last="Sch Tzle">Marc Sch Tzle</name>
<affiliation wicri:level="4"><country xml:lang="fr">Suisse</country>
<wicri:regionArea>Clinic for Orthodontics and Pediatric Dentistry, Center for Dental and Oral Medicine and Cranio‐Maxillofacial Surgery, University of Zurich, Zurich</wicri:regionArea>
<orgName type="university">Université de Zurich</orgName>
<placeName><settlement type="city">Zurich</settlement>
<region nuts="3" type="region">Canton de Zurich</region>
</placeName>
</affiliation>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Orthodontics, Faculty of Dentistry, The Prince Philip Dental Hospital, The University of Hong Kong, Hong Kong SAR</wicri:regionArea>
<wicri:noRegion>Hong Kong SAR</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Golland, Dorota" sort="Golland, Dorota" uniqKey="Golland D" first="Dorota" last="Golland">Dorota Golland</name>
<affiliation wicri:level="4"><country xml:lang="fr">Suisse</country>
<wicri:regionArea>Clinic for Orthodontics and Pediatric Dentistry, Center for Dental and Oral Medicine and Cranio‐Maxillofacial Surgery, University of Zurich, Zurich</wicri:regionArea>
<orgName type="university">Université de Zurich</orgName>
<placeName><settlement type="city">Zurich</settlement>
<region nuts="3" type="region">Canton de Zurich</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Roos, Malgorzata" sort="Roos, Malgorzata" uniqKey="Roos M" first="Malgorzata" last="Roos">Malgorzata Roos</name>
<affiliation wicri:level="4"><country xml:lang="fr">Suisse</country>
<wicri:regionArea>Biostatistics Unit, Institute of Social and Preventive Medicine, University of Zurich, Zurich</wicri:regionArea>
<orgName type="university">Université de Zurich</orgName>
<placeName><settlement type="city">Zurich</settlement>
<region nuts="3" type="region">Canton de Zurich</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Stawarczyk, Bogna" sort="Stawarczyk, Bogna" uniqKey="Stawarczyk B" first="Bogna" last="Stawarczyk">Bogna Stawarczyk</name>
<affiliation wicri:level="4"><country xml:lang="fr">Suisse</country>
<wicri:regionArea>Clinic for Fixed and Removable Prosthodontics and Dental Material Science, Center for Dental and Oral Medicine and Cranio‐Maxillofacial Surgery, University of Zurich, Zurich</wicri:regionArea>
<orgName type="university">Université de Zurich</orgName>
<placeName><settlement type="city">Zurich</settlement>
<region nuts="3" type="region">Canton de Zurich</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint><biblScope unit="vol">21</biblScope>
<biblScope unit="issue">8</biblScope>
<biblScope unit="page" from="781">781</biblScope>
<biblScope unit="page" to="788">788</biblScope>
<biblScope unit="page-count">8</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2010-08">2010-08</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Absoanchor</term>
<term>Anchorage</term>
<term>Breakpoint</term>
<term>Breakpoint value</term>
<term>Breakpoint values</term>
<term>Breakpoints</term>
<term>Breakpoints values</term>
<term>Clin</term>
<term>Clinical orthodontics</term>
<term>Dentistry</term>
<term>Dentofacial orthopedics</term>
<term>Early failure</term>
<term>Impl</term>
<term>Implant</term>
<term>Implant dentistry</term>
<term>Implants research</term>
<term>Insertion</term>
<term>Insertion torque</term>
<term>International journal</term>
<term>John wiley sons</term>
<term>Lomas</term>
<term>Marc scha</term>
<term>Measurement error</term>
<term>Mini</term>
<term>Mini anchor system</term>
<term>Mtlg</term>
<term>Mtlgs</term>
<term>Oral impl</term>
<term>Oral medicine</term>
<term>Orthodontic anchorage</term>
<term>Orthodontic treatment</term>
<term>Orthodontics</term>
<term>Placement table</term>
<term>Primary stability</term>
<term>Scha</term>
<term>Screwdriver</term>
<term>Serror</term>
<term>Spider</term>
<term>Spider screw</term>
<term>Spider screw mtlg</term>
<term>Sterilisation</term>
<term>Sterilisation process</term>
<term>Sterilisation torque screw level</term>
<term>Target torque values</term>
<term>Tomas</term>
<term>Torque</term>
<term>Torque control</term>
<term>Torque level</term>
<term>Torque output</term>
<term>Torque values</term>
<term>Tzle</term>
<term>Variance</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Absoanchor</term>
<term>Anchorage</term>
<term>Breakpoint</term>
<term>Breakpoint value</term>
<term>Breakpoint values</term>
<term>Breakpoints</term>
<term>Breakpoints values</term>
<term>Clin</term>
<term>Clinical orthodontics</term>
<term>Dentistry</term>
<term>Dentofacial orthopedics</term>
<term>Early failure</term>
<term>Impl</term>
<term>Implant</term>
<term>Implant dentistry</term>
<term>Implants research</term>
<term>Insertion</term>
<term>Insertion torque</term>
<term>International journal</term>
<term>John wiley sons</term>
<term>Lomas</term>
<term>Marc scha</term>
<term>Measurement error</term>
<term>Mini</term>
<term>Mini anchor system</term>
<term>Mtlg</term>
<term>Mtlgs</term>
<term>Oral impl</term>
<term>Oral medicine</term>
<term>Orthodontic anchorage</term>
<term>Orthodontic treatment</term>
<term>Orthodontics</term>
<term>Placement table</term>
<term>Primary stability</term>
<term>Scha</term>
<term>Screwdriver</term>
<term>Serror</term>
<term>Spider</term>
<term>Spider screw</term>
<term>Spider screw mtlg</term>
<term>Sterilisation</term>
<term>Sterilisation process</term>
<term>Sterilisation torque screw level</term>
<term>Target torque values</term>
<term>Tomas</term>
<term>Torque</term>
<term>Torque control</term>
<term>Torque level</term>
<term>Torque output</term>
<term>Torque values</term>
<term>Tzle</term>
<term>Variance</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Stérilisation</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Aim: The purpose of this investigation was to determine and compare the accuracy of four available mechanical torque‐limiting gauges (MTLGs) for mini‐screw placement.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005502 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 005502 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Merge |type= RBID |clé= ISTEX:B6F2B296F9007F3B0B2A0DD0FD83CE83BE9587BF |texte= Accuracy of mechanical torque‐limiting gauges for mini‐screw placement }}
![]() | This area was generated with Dilib version V0.6.32. | ![]() |