Accuracy in computer-aided implant surgery--a review.
Identifieur interne : 011723 ( Main/Exploration ); précédent : 011722; suivant : 011724Accuracy in computer-aided implant surgery--a review.
Auteurs : Gerlig Widmann [Autriche] ; Reto Josef BaleSource :
- The International journal of oral & maxillofacial implants [ 0882-2786 ]
Descripteurs français
- KwdFr :
- MESH :
English descriptors
- KwdEn :
- MESH :
Abstract
The objective of this article was to review the different factors and limitations influencing the accuracy of computer-aided implant surgery. In vitro and in vivo accuracy studies of articles and congress proceedings were examined. Similar results using bur tracking as well as image-guided template production techniques have been reported, and both methods allow for precise positioning of dental implants. Compared to the conventional technique, this sophisticated technology requires substantially more financial investment and effort (computerized tomographic imaging, fabrication of a registration template, intraoperative referencing for bur tracking, or image-guided manufacturing of a surgical template) but appears superior on account of its potential to eliminate possible manual placement errors and to systematize reproducible treatment success. The potential for the protection of critical anatomic structures and the esthetic and functional advantages of prosthodontic-driven implant positioning must also be considered. However, long-term clinical studies are necessary to confirm the value of this strategy and to justify the additional radiation dose, effort, and costs.
PubMed: 16634503
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 002779
- to stream PubMed, to step Curation: 002779
- to stream PubMed, to step Checkpoint: 002779
- to stream Ncbi, to step Merge: 001966
- to stream Ncbi, to step Curation: 001966
- to stream Ncbi, to step Checkpoint: 001966
- to stream Main, to step Merge: 012151
- to stream Main, to step Curation: 011723
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Accuracy in computer-aided implant surgery--a review.</title>
<author><name sortKey="Widmann, Gerlig" sort="Widmann, Gerlig" uniqKey="Widmann G" first="Gerlig" last="Widmann">Gerlig Widmann</name>
<affiliation wicri:level="1"><nlm:affiliation>Interdisciplinary Stereotactic Intervention and Planning Laboratory, Innsbruck Medical University, Department of Radiology, Clinical Division of Diagnostic Radiology I, Austria. gerlig.widmann@uibk.ac.at</nlm:affiliation>
<country xml:lang="fr">Autriche</country>
<wicri:regionArea>Interdisciplinary Stereotactic Intervention and Planning Laboratory, Innsbruck Medical University, Department of Radiology, Clinical Division of Diagnostic Radiology I</wicri:regionArea>
<wicri:noRegion>Clinical Division of Diagnostic Radiology I</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Bale, Reto Josef" sort="Bale, Reto Josef" uniqKey="Bale R" first="Reto Josef" last="Bale">Reto Josef Bale</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2006 Mar-Apr</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:16634503</idno>
<idno type="pmid">16634503</idno>
<idno type="wicri:Area/PubMed/Corpus">002779</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002779</idno>
<idno type="wicri:Area/PubMed/Curation">002779</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">002779</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002779</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">002779</idno>
<idno type="wicri:Area/Ncbi/Merge">001966</idno>
<idno type="wicri:Area/Ncbi/Curation">001966</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001966</idno>
<idno type="wicri:doubleKey">0882-2786::Widmann G:accuracy:in:computer</idno>
<idno type="wicri:Area/Main/Merge">012151</idno>
<idno type="wicri:Area/Main/Curation">011723</idno>
<idno type="wicri:Area/Main/Exploration">011723</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Accuracy in computer-aided implant surgery--a review.</title>
<author><name sortKey="Widmann, Gerlig" sort="Widmann, Gerlig" uniqKey="Widmann G" first="Gerlig" last="Widmann">Gerlig Widmann</name>
<affiliation wicri:level="1"><nlm:affiliation>Interdisciplinary Stereotactic Intervention and Planning Laboratory, Innsbruck Medical University, Department of Radiology, Clinical Division of Diagnostic Radiology I, Austria. gerlig.widmann@uibk.ac.at</nlm:affiliation>
<country xml:lang="fr">Autriche</country>
<wicri:regionArea>Interdisciplinary Stereotactic Intervention and Planning Laboratory, Innsbruck Medical University, Department of Radiology, Clinical Division of Diagnostic Radiology I</wicri:regionArea>
<wicri:noRegion>Clinical Division of Diagnostic Radiology I</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Bale, Reto Josef" sort="Bale, Reto Josef" uniqKey="Bale R" first="Reto Josef" last="Bale">Reto Josef Bale</name>
</author>
</analytic>
<series><title level="j">The International journal of oral & maxillofacial implants</title>
<idno type="ISSN">0882-2786</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Cost-Benefit Analysis</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Models</term>
<term>Humans</term>
<term>Imaging, Three-Dimensional</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Models, Anatomic</term>
<term>Reproducibility of Results</term>
<term>Surgery, Computer-Assisted</term>
<term>Tomography, Spiral Computed</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Analyse coût-bénéfice</term>
<term>Chirurgie assistée par ordinateur</term>
<term>Humains</term>
<term>Imagerie tridimensionnelle</term>
<term>Modèles anatomiques</term>
<term>Modèles dentaires</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Pose d'implant dentaire endo-osseux ()</term>
<term>Reproductibilité des résultats</term>
<term>Tomodensitométrie hélicoïdale</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr"><term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Cost-Benefit Analysis</term>
<term>Dental Models</term>
<term>Humans</term>
<term>Imaging, Three-Dimensional</term>
<term>Models, Anatomic</term>
<term>Reproducibility of Results</term>
<term>Surgery, Computer-Assisted</term>
<term>Tomography, Spiral Computed</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Analyse coût-bénéfice</term>
<term>Chirurgie assistée par ordinateur</term>
<term>Humains</term>
<term>Imagerie tridimensionnelle</term>
<term>Modèles anatomiques</term>
<term>Modèles dentaires</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Reproductibilité des résultats</term>
<term>Tomodensitométrie hélicoïdale</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The objective of this article was to review the different factors and limitations influencing the accuracy of computer-aided implant surgery. In vitro and in vivo accuracy studies of articles and congress proceedings were examined. Similar results using bur tracking as well as image-guided template production techniques have been reported, and both methods allow for precise positioning of dental implants. Compared to the conventional technique, this sophisticated technology requires substantially more financial investment and effort (computerized tomographic imaging, fabrication of a registration template, intraoperative referencing for bur tracking, or image-guided manufacturing of a surgical template) but appears superior on account of its potential to eliminate possible manual placement errors and to systematize reproducible treatment success. The potential for the protection of critical anatomic structures and the esthetic and functional advantages of prosthodontic-driven implant positioning must also be considered. However, long-term clinical studies are necessary to confirm the value of this strategy and to justify the additional radiation dose, effort, and costs.</div>
</front>
</TEI>
<affiliations><list><country><li>Autriche</li>
</country>
</list>
<tree><noCountry><name sortKey="Bale, Reto Josef" sort="Bale, Reto Josef" uniqKey="Bale R" first="Reto Josef" last="Bale">Reto Josef Bale</name>
</noCountry>
<country name="Autriche"><noRegion><name sortKey="Widmann, Gerlig" sort="Widmann, Gerlig" uniqKey="Widmann G" first="Gerlig" last="Widmann">Gerlig Widmann</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 011723 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 011723 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Exploration |type= RBID |clé= pubmed:16634503 |texte= Accuracy in computer-aided implant surgery--a review. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:16634503" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |