Vertical load distribution on a three‐unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study.
Identifieur interne : 00A658 ( Main/Exploration ); précédent : 00A657; suivant : 00A659Vertical load distribution on a three‐unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study.
Auteurs : B. Rangert ; J. Gunne ; P. Glantz [Suède] ; A. Svensson [Suède]Source :
- Clinical Oral Implants Research [ 0905-7161 ] ; 1995-03.
Abstract
In vivo bite forces, implant axial forces and bending moments were measured on 5 patients with fixed posterior prostheses supported by a natural tooth and a single Brinemark implant. The results demonstrate that the vertical loads applied to the prostheses are shared between the tooth and the implant. The maximum bending moment transferred to the implant (10–15N.cm) was well below the acceptable load limits for the mechanical components (50–60N.cm), even at bite forces exceeding 100 N. The main reason for this load sharing seems to be the inherent bending flexibility of the implant screw joint, which matches the axial flexibility of the periodontal ligament of the tooth.
Url:
DOI: 10.1034/j.1600-0501.1995.060105.x
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 005B29
- to stream Istex, to step Curation: 005B29
- to stream Istex, to step Checkpoint: 004C96
- to stream Main, to step Merge: 00AC62
- to stream Main, to step Curation: 00A658
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Vertical load distribution on a three‐unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study.</title>
<author><name sortKey="Rangert, B" sort="Rangert, B" uniqKey="Rangert B" first="B." last="Rangert">B. Rangert</name>
</author>
<author><name sortKey="Gunne, J" sort="Gunne, J" uniqKey="Gunne J" first="J." last="Gunne">J. Gunne</name>
</author>
<author><name sortKey="Glantz, P" sort="Glantz, P" uniqKey="Glantz P" first="P." last="Glantz">P. Glantz</name>
</author>
<author><name sortKey="Svensson, A" sort="Svensson, A" uniqKey="Svensson A" first="A." last="Svensson">A. Svensson</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:B740D6CA00D1876539DAE2B8D30E4A8C475751C9</idno>
<date when="1995" year="1995">1995</date>
<idno type="doi">10.1034/j.1600-0501.1995.060105.x</idno>
<idno type="url">https://api.istex.fr/document/B740D6CA00D1876539DAE2B8D30E4A8C475751C9/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">005B29</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">005B29</idno>
<idno type="wicri:Area/Istex/Curation">005B29</idno>
<idno type="wicri:Area/Istex/Checkpoint">004C96</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">004C96</idno>
<idno type="wicri:doubleKey">0905-7161:1995:Rangert B:vertical:load:distribution</idno>
<idno type="wicri:Area/Main/Merge">00AC62</idno>
<idno type="wicri:Area/Main/Curation">00A658</idno>
<idno type="wicri:Area/Main/Exploration">00A658</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main"><hi rend="italic">in vivo</hi>
<:t></:t>
<:t></:t>
</title>
<author><name sortKey="Rangert, B" sort="Rangert, B" uniqKey="Rangert B" first="B." last="Rangert">B. Rangert</name>
<affiliation><wicri:noCountry code="subField"></wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Gunne, J" sort="Gunne, J" uniqKey="Gunne J" first="J." last="Gunne">J. Gunne</name>
<affiliation><wicri:noCountry code="subField"></wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Glantz, P" sort="Glantz, P" uniqKey="Glantz P" first="P." last="Glantz">P. Glantz</name>
<affiliation wicri:level="1"><country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Prosthetic Dentistry, University of Lund, Malmö</wicri:regionArea>
<wicri:noRegion>Malmö</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Svensson, A" sort="Svensson, A" uniqKey="Svensson A" first="A." last="Svensson">A. Svensson</name>
<affiliation wicri:level="1"><country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Prosthetic Dentistry, University of Lund, Malmö</wicri:regionArea>
<wicri:noRegion>Malmö</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint><biblScope unit="vol">6</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="40">40</biblScope>
<biblScope unit="page" to="46">46</biblScope>
<publisher>Munksgaard International Publishers</publisher>
<pubPlace>Copenhagen</pubPlace>
<date type="published" when="1995-03">1995-03</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">In vivo bite forces, implant axial forces and bending moments were measured on 5 patients with fixed posterior prostheses supported by a natural tooth and a single Brinemark implant. The results demonstrate that the vertical loads applied to the prostheses are shared between the tooth and the implant. The maximum bending moment transferred to the implant (10–15N.cm) was well below the acceptable load limits for the mechanical components (50–60N.cm), even at bite forces exceeding 100 N. The main reason for this load sharing seems to be the inherent bending flexibility of the implant screw joint, which matches the axial flexibility of the periodontal ligament of the tooth.</div>
</front>
</TEI>
<affiliations><list><country><li>Suède</li>
</country>
</list>
<tree><noCountry><name sortKey="Gunne, J" sort="Gunne, J" uniqKey="Gunne J" first="J." last="Gunne">J. Gunne</name>
<name sortKey="Rangert, B" sort="Rangert, B" uniqKey="Rangert B" first="B." last="Rangert">B. Rangert</name>
</noCountry>
<country name="Suède"><noRegion><name sortKey="Glantz, P" sort="Glantz, P" uniqKey="Glantz P" first="P." last="Glantz">P. Glantz</name>
</noRegion>
<name sortKey="Svensson, A" sort="Svensson, A" uniqKey="Svensson A" first="A." last="Svensson">A. Svensson</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00A658 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 00A658 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:B740D6CA00D1876539DAE2B8D30E4A8C475751C9 |texte= Vertical load distribution on a three‐unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study. }}
This area was generated with Dilib version V0.6.32. |