Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A clinical retrospective evaluation of FA/HA coated (Biocomp®) dental implants. Results after 1 year.

Identifieur interne : 00A382 ( Main/Exploration ); précédent : 00A381; suivant : 00A383

A clinical retrospective evaluation of FA/HA coated (Biocomp®) dental implants. Results after 1 year.

Auteurs : M. S. Cune ; I. P. Van Rossen ; C. De Putter ; R. P. J. Wils [Pays-Bas]

Source :

RBID : ISTEX:56CF705944AE67A6635EB1A85B1DADAF98A01AAD

Abstract

In this retrospective clinical evaluation, the performance of loaded titanium implants with a bilayer bioactive surface coating of the relatively reactive hydroxylapatite (HA. outer layer) and the more stable fluorapatite (FA, inner layer) was evaluated. 98 consecutive patients were included in the study for a total of 354 implants, loaded by overdentures, fixed partial dentures and single tooth replacements. Statistical analyses revealed a cumulative probability of implant survival on a per patient basis of 94.5%(s.e. 2.7%) one year after implant installation. On implants that were lost parts of the bilayer FA/HA coating had vanished as a result of primary or secondary infection and subsequently epithelial down growth. Most complications were associated with implants placed in the maxilla. Periotest values (PTV) were generally high, indicating adequate osseointegration. The PTV's were statistical significantly less favorable in implants placed in the maxilla. The most favorable PTV’s and gingival index scores were found around implants servicing overdentures. Marginal bone loss averaged ‐ 2mm during the observation period. The amount of marginal bone loss corresponded with the distance from the neck of the implant to the first thread of the implant's cervical screw‐section. It is concluded that, during the relatively short observation period, the FA/HA coated implants function adequately. However, in the absence of a direct implant‐to‐bone contact preceding implant loss, part of the FA/HA coating on the titanium implants generally dissolves.

Url:
DOI: 10.1034/j.1600-0501.1996.070407.x


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A clinical retrospective evaluation of FA/HA coated (Biocomp®) dental implants. Results after 1 year.</title>
<author>
<name sortKey="Cune, M S" sort="Cune, M S" uniqKey="Cune M" first="M. S." last="Cune">M. S. Cune</name>
</author>
<author>
<name sortKey="Van Rossen, I P" sort="Van Rossen, I P" uniqKey="Van Rossen I" first="I. P." last="Van Rossen">I. P. Van Rossen</name>
</author>
<author>
<name sortKey="De Putter, C" sort="De Putter, C" uniqKey="De Putter C" first="C." last="De Putter">C. De Putter</name>
</author>
<author>
<name sortKey="Wils, R P J" sort="Wils, R P J" uniqKey="Wils R" first="R. P. J." last="Wils">R. P. J. Wils</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:56CF705944AE67A6635EB1A85B1DADAF98A01AAD</idno>
<date when="1996" year="1996">1996</date>
<idno type="doi">10.1034/j.1600-0501.1996.070407.x</idno>
<idno type="url">https://api.istex.fr/document/56CF705944AE67A6635EB1A85B1DADAF98A01AAD/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002A72</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">002A72</idno>
<idno type="wicri:Area/Istex/Curation">002A72</idno>
<idno type="wicri:Area/Istex/Checkpoint">004C06</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">004C06</idno>
<idno type="wicri:doubleKey">0905-7161:1996:Cune M:a:clinical:retrospective</idno>
<idno type="wicri:Area/Main/Merge">00A947</idno>
<idno type="wicri:Area/Main/Curation">00A382</idno>
<idno type="wicri:Area/Main/Exploration">00A382</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">A clinical retrospective evaluation of FA/HA coated (Biocomp®) dental implants. Results after 1 year.</title>
<author>
<name sortKey="Cune, M S" sort="Cune, M S" uniqKey="Cune M" first="M. S." last="Cune">M. S. Cune</name>
<affiliation>
<wicri:noCountry code="subField"></wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Van Rossen, I P" sort="Van Rossen, I P" uniqKey="Van Rossen I" first="I. P." last="Van Rossen">I. P. Van Rossen</name>
<affiliation>
<wicri:noCountry code="subField"></wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="De Putter, C" sort="De Putter, C" uniqKey="De Putter C" first="C." last="De Putter">C. De Putter</name>
<affiliation>
<wicri:noCountry code="subField"></wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Wils, R P J" sort="Wils, R P J" uniqKey="Wils R" first="R. P. J." last="Wils">R. P. J. Wils</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Pays-Bas</country>
<wicri:regionArea>Private Practice</wicri:regionArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint>
<biblScope unit="vol">7</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="345">345</biblScope>
<biblScope unit="page" to="353">353</biblScope>
<publisher>Munksgaard International Publishers</publisher>
<pubPlace>Copenhagen</pubPlace>
<date type="published" when="1996-12">1996-12</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In this retrospective clinical evaluation, the performance of loaded titanium implants with a bilayer bioactive surface coating of the relatively reactive hydroxylapatite (HA. outer layer) and the more stable fluorapatite (FA, inner layer) was evaluated. 98 consecutive patients were included in the study for a total of 354 implants, loaded by overdentures, fixed partial dentures and single tooth replacements. Statistical analyses revealed a cumulative probability of implant survival on a per patient basis of 94.5%(s.e. 2.7%) one year after implant installation. On implants that were lost parts of the bilayer FA/HA coating had vanished as a result of primary or secondary infection and subsequently epithelial down growth. Most complications were associated with implants placed in the maxilla. Periotest values (PTV) were generally high, indicating adequate osseointegration. The PTV's were statistical significantly less favorable in implants placed in the maxilla. The most favorable PTV’s and gingival index scores were found around implants servicing overdentures. Marginal bone loss averaged ‐ 2mm during the observation period. The amount of marginal bone loss corresponded with the distance from the neck of the implant to the first thread of the implant's cervical screw‐section. It is concluded that, during the relatively short observation period, the FA/HA coated implants function adequately. However, in the absence of a direct implant‐to‐bone contact preceding implant loss, part of the FA/HA coating on the titanium implants generally dissolves.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Pays-Bas</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Cune, M S" sort="Cune, M S" uniqKey="Cune M" first="M. S." last="Cune">M. S. Cune</name>
<name sortKey="De Putter, C" sort="De Putter, C" uniqKey="De Putter C" first="C." last="De Putter">C. De Putter</name>
<name sortKey="Van Rossen, I P" sort="Van Rossen, I P" uniqKey="Van Rossen I" first="I. P." last="Van Rossen">I. P. Van Rossen</name>
</noCountry>
<country name="Pays-Bas">
<noRegion>
<name sortKey="Wils, R P J" sort="Wils, R P J" uniqKey="Wils R" first="R. P. J." last="Wils">R. P. J. Wils</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00A382 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 00A382 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:56CF705944AE67A6635EB1A85B1DADAF98A01AAD
   |texte=   A clinical retrospective evaluation of FA/HA coated (Biocomp®) dental implants. Results after 1 year.
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022