Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro‐ and microstructure

Identifieur interne : 009936 ( Main/Exploration ); précédent : 009935; suivant : 009937

Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro‐ and microstructure

Auteurs : Michael R. Norton [Royaume-Uni]

Source :

RBID : ISTEX:4E4A09312E83EC120E1B5DD2EA0233C36D91792D

Abstract

The concept of a conical implant design to accommodate single tooth replacement, has previously been shown to result in excessive bone loss, around the machined titanium conical collar, usually down to the 1st thread. This unusually aggressive loss of bone was shown to occur within a short period of time, post loading, with greater than 3 mm of bone loss occurring within the 1st 6 months to 1 year. The influence of implant design, surface texture and microleakage have all been highlighted as a potential cause. A modification of the surface structure, both at the macroscopic and microscopic level, as well as an altered fixture‐abutment interface design has resulted in the maintenance of marginal bone around a single tooth titanium implant with a similar conical design. The radiographic follow‐up of 33 implants loaded for up to 4 years, has revealed, by comparison, a most favourable maintenance of marginal bone around the conical collar, with a mean marginal bone loss of 0.32 mm mesially and 0.34 mm distally for the whole group. The cumulative mean marginal bone loss mesially and distally is 0.42 mm and 0.40 mm from 1 to 2 years, 0.54 mm and 0.43 mm from 2 to 3 years, 0.51 mm and 0.24 mm from 3 to 4 years, and 0.62 mm and 0.60 mm for implants past their 4 year recall.

Url:
DOI: 10.1034/j.1600-0501.1998.090204.x


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro‐ and microstructure</title>
<author>
<name sortKey="Norton, Michael R" sort="Norton, Michael R" uniqKey="Norton M" first="Michael R." last="Norton">Michael R. Norton</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:4E4A09312E83EC120E1B5DD2EA0233C36D91792D</idno>
<date when="1998" year="1998">1998</date>
<idno type="doi">10.1034/j.1600-0501.1998.090204.x</idno>
<idno type="url">https://api.istex.fr/document/4E4A09312E83EC120E1B5DD2EA0233C36D91792D/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002662</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">002662</idno>
<idno type="wicri:Area/Istex/Curation">002662</idno>
<idno type="wicri:Area/Istex/Checkpoint">004595</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">004595</idno>
<idno type="wicri:doubleKey">0905-7161:1998:Norton M:marginal:bone:levels</idno>
<idno type="wicri:Area/Main/Merge">009E02</idno>
<idno type="wicri:Area/Main/Curation">009936</idno>
<idno type="wicri:Area/Main/Exploration">009936</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro‐ and microstructure</title>
<author>
<name sortKey="Norton, Michael R" sort="Norton, Michael R" uniqKey="Norton M" first="Michael R." last="Norton">Michael R. Norton</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Dept of Maxillofacial Surgery, Charing Cross Hospital, London; Dept of Maxillo‐facial Surgery, Bedford Hospital, Bedford; and in private practice, London</wicri:regionArea>
<placeName>
<settlement type="city">Londres</settlement>
<region type="country">Angleterre</region>
<region type="région" nuts="1">Grand Londres</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint>
<biblScope unit="vol">9</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="91">91</biblScope>
<biblScope unit="page" to="99">99</biblScope>
<publisher>Munksgaard International Publishers</publisher>
<pubPlace>Copenhagen</pubPlace>
<date type="published" when="1998-04">1998-04</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The concept of a conical implant design to accommodate single tooth replacement, has previously been shown to result in excessive bone loss, around the machined titanium conical collar, usually down to the 1st thread. This unusually aggressive loss of bone was shown to occur within a short period of time, post loading, with greater than 3 mm of bone loss occurring within the 1st 6 months to 1 year. The influence of implant design, surface texture and microleakage have all been highlighted as a potential cause. A modification of the surface structure, both at the macroscopic and microscopic level, as well as an altered fixture‐abutment interface design has resulted in the maintenance of marginal bone around a single tooth titanium implant with a similar conical design. The radiographic follow‐up of 33 implants loaded for up to 4 years, has revealed, by comparison, a most favourable maintenance of marginal bone around the conical collar, with a mean marginal bone loss of 0.32 mm mesially and 0.34 mm distally for the whole group. The cumulative mean marginal bone loss mesially and distally is 0.42 mm and 0.40 mm from 1 to 2 years, 0.54 mm and 0.43 mm from 2 to 3 years, 0.51 mm and 0.24 mm from 3 to 4 years, and 0.62 mm and 0.60 mm for implants past their 4 year recall.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
<region>
<li>Angleterre</li>
<li>Grand Londres</li>
</region>
<settlement>
<li>Londres</li>
</settlement>
</list>
<tree>
<country name="Royaume-Uni">
<region name="Angleterre">
<name sortKey="Norton, Michael R" sort="Norton, Michael R" uniqKey="Norton M" first="Michael R." last="Norton">Michael R. Norton</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009936 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 009936 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:4E4A09312E83EC120E1B5DD2EA0233C36D91792D
   |texte=   Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro‐ and microstructure
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022