Astra Tech and Brånemark System Implants: A Prospective 5‐Year Comparative Study. Results after One Year

Identifieur interne : 009469 ( Main/Exploration ); précédent : 009468; suivant : 009470

Astra Tech and Brånemark System Implants: A Prospective 5‐Year Comparative Study. Results after One Year

Auteurs : Per Astrand [Suède] ; Bo Engquist [Suède] ; Simon Dahlgren [Suède] ; Eva Engquist [Suède] ; Hartmut Feldmann [Suède] ; Kerstin Gröndahl [Suède]

Source :

RBID : ISTEX:493BEA589B477B2BC9CA1E7EA21657753D09F0EB

English descriptors

Abstract

Background: Endosseous dental implants are used frequently, and many implant systems are available. The scientific documentation of the implant system presents a great variation, and it is often difficult to compare studies of different systems. Purpose: The aim of this study was to compare two Swedish implant systems (Astra Tech and Brånemark System± implants), in a prospective randomized study. Materials and Methods: Sixty‐six patients were equally distributed between the two implant systems; 184 Astra Tech and 187 Brånemark System implants were used. The patients have been followed annually with clinical and radiographic examinations. The results after 1 year are reported. Results: The abutment procedure was found to be easier and less time‐consuming with Astra Tech than with Brånemark implants. The operation times in minutes (mean ± SEM) were for the respective implant 35 ± 4.0 and 51 ± 4.8 in the maxilla and 32 ± 3.8 and 43 ± 2.4 in the mandible. The differences in both cases were significant: p <.02 and p <.05, respectively. The failure rate for Astra Tech implants was 0.5% and for Brånemark implants 4.3%. The difference was significant (p <.05); however, taking into account that five of the eight implant losses in the Brånemark implant group occurred in one patient, an intraindividual correlation cannot be excluded. Therefore, this result should be interpreted with caution. The marginal bone level changes were examined already from the fixture installation. The major bone loss was found between fixture installation and baseline. This bone loss was several times greater than the bone loss between the baseline and the 1‐year follow‐up. The total bone loss during the observation period did not differ significantly between the systems, but they had different resorption patterns. The bone loss in the upper jaw between baseline and 1‐year follow‐up was 0.22 ± 0.14 and 0.03 ± 0.09 mm for the Astra Tech and Brånemark implants, respectively. In the lower jaw, the loss was ‐0.31 for both systems. The frequency of plaque accumulation and bleeding on probing did not differ between the implant systems. Conclusions: Abutment connection with Astra Tech implants was simpler than the corresponding surgery with Brånemark System implants and the survival rate of Astra Tech implants was higher than that of Brånemark system implants.

Url:
DOI: 10.1111/j.1708-8208.1999.tb00087.x


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Astra Tech and Brånemark System Implants: A Prospective 5‐Year Comparative Study. Results after One Year</title>
<author>
<name sortKey="Astrand, Per" sort="Astrand, Per" uniqKey="Astrand P" first="Per" last="Astrand">Per Astrand</name>
</author>
<author>
<name sortKey="Engquist, Bo" sort="Engquist, Bo" uniqKey="Engquist B" first="Bo" last="Engquist">Bo Engquist</name>
</author>
<author>
<name sortKey="Dahlgren, Simon" sort="Dahlgren, Simon" uniqKey="Dahlgren S" first="Simon" last="Dahlgren">Simon Dahlgren</name>
</author>
<author>
<name sortKey="Engquist, Eva" sort="Engquist, Eva" uniqKey="Engquist E" first="Eva" last="Engquist">Eva Engquist</name>
</author>
<author>
<name sortKey="Feldmann, Hartmut" sort="Feldmann, Hartmut" uniqKey="Feldmann H" first="Hartmut" last="Feldmann">Hartmut Feldmann</name>
</author>
<author>
<name sortKey="Grondahl, Kerstin" sort="Grondahl, Kerstin" uniqKey="Grondahl K" first="Kerstin" last="Gröndahl">Kerstin Gröndahl</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:493BEA589B477B2BC9CA1E7EA21657753D09F0EB</idno>
<date when="1999" year="1999">1999</date>
<idno type="doi">10.1111/j.1708-8208.1999.tb00087.x</idno>
<idno type="url">https://api.istex.fr/document/493BEA589B477B2BC9CA1E7EA21657753D09F0EB/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002399</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">002399</idno>
<idno type="wicri:Area/Istex/Curation">002399</idno>
<idno type="wicri:Area/Istex/Checkpoint">004340</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">004340</idno>
<idno type="wicri:doubleKey">1523-0899:1999:Astrand P:astra:tech:and</idno>
<idno type="wicri:Area/Main/Merge">009895</idno>
<idno type="wicri:Area/Main/Curation">009469</idno>
<idno type="wicri:Area/Main/Exploration">009469</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Astra Tech and Brånemark System Implants: A Prospective 5‐Year Comparative Study. Results after One Year</title>
<author>
<name sortKey="Astrand, Per" sort="Astrand, Per" uniqKey="Astrand P" first="Per" last="Astrand">Per Astrand</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Associate Professor, Department of Oral and Maxillofacial Surgery, University Hospital, Linköping</wicri:regionArea>
<wicri:noRegion>Linköping</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Correspondence address: Reprint requests: Per Åstrand, DDS, PhD, Department of Oral and Maxillofacial Surgery, University Hospital, SE‐58185, Linköping</wicri:regionArea>
<wicri:noRegion>Linköping</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Engquist, Bo" sort="Engquist, Bo" uniqKey="Engquist B" first="Bo" last="Engquist">Bo Engquist</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Consultant in Prosthodontics, Department of Prosthodontics, Public Dental Health Care, Linköping</wicri:regionArea>
<wicri:noRegion>Linköping</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Dahlgren, Simon" sort="Dahlgren, Simon" uniqKey="Dahlgren S" first="Simon" last="Dahlgren">Simon Dahlgren</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Consultant in Prosthodontics, Department of Prosthodontics, Public Dental Health Care, Linköping</wicri:regionArea>
<wicri:noRegion>Linköping</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Engquist, Eva" sort="Engquist, Eva" uniqKey="Engquist E" first="Eva" last="Engquist">Eva Engquist</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Public Dental Health Care, Ekholmen, Linköping</wicri:regionArea>
<wicri:noRegion>Linköping</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Feldmann, Hartmut" sort="Feldmann, Hartmut" uniqKey="Feldmann H" first="Hartmut" last="Feldmann">Hartmut Feldmann</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Consultant in Oral and Maxillofacial Surgery, Department of Oral and Maxillofacial Surgery, University Hospital, Linköping</wicri:regionArea>
<wicri:noRegion>Linköping</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Grondahl, Kerstin" sort="Grondahl, Kerstin" uniqKey="Grondahl K" first="Kerstin" last="Gröndahl">Kerstin Gröndahl</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Associate Professor, Department of Oral Diagnostic Radiology, Göteborg University, Göteborg</wicri:regionArea>
<orgName type="university">Université de Göteborg</orgName>
<placeName>
<settlement type="city">Göteborg</settlement>
<region nuts="1">Götaland</region>
<region nuts="1">Suède occidentale</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Implant Dentistry and Related Research</title>
<title level="j" type="alt">CLINICAL IMPLANT DENTISTRY RELATED RESEARCH</title>
<idno type="ISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<imprint>
<biblScope unit="vol">1</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="17">17</biblScope>
<biblScope unit="page" to="26">26</biblScope>
<biblScope unit="page-count">10</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="1999-07">1999-07</date>
</imprint>
<idno type="ISSN">1523-0899</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1523-0899</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Abutment</term>
<term>Abutment connection</term>
<term>Astra</term>
<term>Astra tech</term>
<term>Astra tech implants</term>
<term>Baseline</term>
<term>Baseline examination</term>
<term>Bone level</term>
<term>Bone loss</term>
<term>Branemark</term>
<term>Branemark implants</term>
<term>Branemark system</term>
<term>Branemark system implants</term>
<term>Brdnemark system implants</term>
<term>Brinemark</term>
<term>Brinemark implants</term>
<term>Brinemark system</term>
<term>Brinemark system implants</term>
<term>Clinical implant dentistry</term>
<term>Corresponding figures</term>
<term>Edentulous</term>
<term>Edentulous jaws</term>
<term>Failure rate</term>
<term>First year</term>
<term>Fixture</term>
<term>Fixture insertion</term>
<term>Fixture installation</term>
<term>Implant</term>
<term>Implant losses</term>
<term>Implant system</term>
<term>Implant systems</term>
<term>Inclusion criteria</term>
<term>Insertion</term>
<term>Mandible</term>
<term>Marginal bone changes</term>
<term>Marginal bone level</term>
<term>Marginal bone level changes</term>
<term>Marginal bone loss</term>
<term>Maxilla</term>
<term>Maxillary</term>
<term>Maxillary implants</term>
<term>Maxillofacial surgery</term>
<term>Operation time</term>
<term>Oral maxillofac implants</term>
<term>Osseointegrated implants</term>
<term>Plaque accumulation</term>
<term>Primary stability</term>
<term>Prosthetic</term>
<term>Prosthetic procedures</term>
<term>Radiographic</term>
<term>Radiographic examination</term>
<term>Reference point</term>
<term>Surgical procedures</term>
<term>Survival rate</term>
<term>Tech</term>
<term>University hospital</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Abutment</term>
<term>Abutment connection</term>
<term>Astra</term>
<term>Astra tech</term>
<term>Astra tech implants</term>
<term>Baseline</term>
<term>Baseline examination</term>
<term>Bone level</term>
<term>Bone loss</term>
<term>Branemark</term>
<term>Branemark implants</term>
<term>Branemark system</term>
<term>Branemark system implants</term>
<term>Brdnemark system implants</term>
<term>Brinemark</term>
<term>Brinemark implants</term>
<term>Brinemark system</term>
<term>Brinemark system implants</term>
<term>Clinical implant dentistry</term>
<term>Corresponding figures</term>
<term>Edentulous</term>
<term>Edentulous jaws</term>
<term>Failure rate</term>
<term>First year</term>
<term>Fixture</term>
<term>Fixture insertion</term>
<term>Fixture installation</term>
<term>Implant</term>
<term>Implant losses</term>
<term>Implant system</term>
<term>Implant systems</term>
<term>Inclusion criteria</term>
<term>Insertion</term>
<term>Mandible</term>
<term>Marginal bone changes</term>
<term>Marginal bone level</term>
<term>Marginal bone level changes</term>
<term>Marginal bone loss</term>
<term>Maxilla</term>
<term>Maxillary</term>
<term>Maxillary implants</term>
<term>Maxillofacial surgery</term>
<term>Operation time</term>
<term>Oral maxillofac implants</term>
<term>Osseointegrated implants</term>
<term>Plaque accumulation</term>
<term>Primary stability</term>
<term>Prosthetic</term>
<term>Prosthetic procedures</term>
<term>Radiographic</term>
<term>Radiographic examination</term>
<term>Reference point</term>
<term>Surgical procedures</term>
<term>Survival rate</term>
<term>Tech</term>
<term>University hospital</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Background: Endosseous dental implants are used frequently, and many implant systems are available. The scientific documentation of the implant system presents a great variation, and it is often difficult to compare studies of different systems. Purpose: The aim of this study was to compare two Swedish implant systems (Astra Tech and Brånemark System± implants), in a prospective randomized study. Materials and Methods: Sixty‐six patients were equally distributed between the two implant systems; 184 Astra Tech and 187 Brånemark System implants were used. The patients have been followed annually with clinical and radiographic examinations. The results after 1 year are reported. Results: The abutment procedure was found to be easier and less time‐consuming with Astra Tech than with Brånemark implants. The operation times in minutes (mean ± SEM) were for the respective implant 35 ± 4.0 and 51 ± 4.8 in the maxilla and 32 ± 3.8 and 43 ± 2.4 in the mandible. The differences in both cases were significant: p <.02 and p <.05, respectively. The failure rate for Astra Tech implants was 0.5% and for Brånemark implants 4.3%. The difference was significant (p <.05); however, taking into account that five of the eight implant losses in the Brånemark implant group occurred in one patient, an intraindividual correlation cannot be excluded. Therefore, this result should be interpreted with caution. The marginal bone level changes were examined already from the fixture installation. The major bone loss was found between fixture installation and baseline. This bone loss was several times greater than the bone loss between the baseline and the 1‐year follow‐up. The total bone loss during the observation period did not differ significantly between the systems, but they had different resorption patterns. The bone loss in the upper jaw between baseline and 1‐year follow‐up was 0.22 ± 0.14 and 0.03 ± 0.09 mm for the Astra Tech and Brånemark implants, respectively. In the lower jaw, the loss was ‐0.31 for both systems. The frequency of plaque accumulation and bleeding on probing did not differ between the implant systems. Conclusions: Abutment connection with Astra Tech implants was simpler than the corresponding surgery with Brånemark System implants and the survival rate of Astra Tech implants was higher than that of Brånemark system implants.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Suède</li>
</country>
<region>
<li>Götaland</li>
<li>Suède occidentale</li>
</region>
<settlement>
<li>Göteborg</li>
</settlement>
<orgName>
<li>Université de Göteborg</li>
</orgName>
</list>
<tree>
<country name="Suède">
<noRegion>
<name sortKey="Astrand, Per" sort="Astrand, Per" uniqKey="Astrand P" first="Per" last="Astrand">Per Astrand</name>
</noRegion>
<name sortKey="Astrand, Per" sort="Astrand, Per" uniqKey="Astrand P" first="Per" last="Astrand">Per Astrand</name>
<name sortKey="Dahlgren, Simon" sort="Dahlgren, Simon" uniqKey="Dahlgren S" first="Simon" last="Dahlgren">Simon Dahlgren</name>
<name sortKey="Engquist, Bo" sort="Engquist, Bo" uniqKey="Engquist B" first="Bo" last="Engquist">Bo Engquist</name>
<name sortKey="Engquist, Eva" sort="Engquist, Eva" uniqKey="Engquist E" first="Eva" last="Engquist">Eva Engquist</name>
<name sortKey="Feldmann, Hartmut" sort="Feldmann, Hartmut" uniqKey="Feldmann H" first="Hartmut" last="Feldmann">Hartmut Feldmann</name>
<name sortKey="Grondahl, Kerstin" sort="Grondahl, Kerstin" uniqKey="Grondahl K" first="Kerstin" last="Gröndahl">Kerstin Gröndahl</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009469 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 009469 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:493BEA589B477B2BC9CA1E7EA21657753D09F0EB
   |texte=   Astra Tech and Brånemark System Implants: A Prospective 5‐Year Comparative Study. Results after One Year
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022