Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications
Identifieur interne : 008A60 ( Main/Exploration ); précédent : 008A59; suivant : 008A61Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications
Auteurs : Josef W. Freudenthaler [Autriche] ; Hans-Peter Bantleon [Autriche] ; Robert Haas [Autriche]Source :
- Clinical Oral Implants Research [ 0905-7161 ] ; 2001-08.
Descripteurs français
- Wicri :
- topic : Titane.
English descriptors
- KwdEn :
- Agenesis, Anchorage, Anchorage preparation, Anchorage situations, Anterior teeth, Anterior unit, Antirotation lever, Bicortical, Bicortical anchorage, Bicortical titanium screws, Biocortical titanium screws, Canine, Canine relation, Critical anchorage, Deciduous molar, Dental implants, Edentulous areas, European journal, Extraction site, Favorable translatory tooth movement, Force system, Freudenthaler, Further treatment, Immediate loading, Implant, Insertion, Insertion site, Insertion sites, Local anesthesia, Mandible, Mobile mucosa, Molar, Molar protraction, Oral impl, Orthodontic forces, Orthodontic treatment, Palatal implants, Patient compliance, Patient selection, Posterior teeth, Posterior tooth, Preliminary report, Protraction, Reactive unit, Second generation, Second premolar, Titanium, Titanium screw, Titanium sleeve, Total treatment time, Vacuum foil, Vienna university school.
- Teeft :
- Agenesis, Anchorage, Anchorage preparation, Anchorage situations, Anterior teeth, Anterior unit, Antirotation lever, Bicortical, Bicortical anchorage, Bicortical titanium screws, Biocortical titanium screws, Canine, Canine relation, Critical anchorage, Deciduous molar, Dental implants, Edentulous areas, European journal, Extraction site, Favorable translatory tooth movement, Force system, Freudenthaler, Further treatment, Immediate loading, Implant, Insertion, Insertion site, Insertion sites, Local anesthesia, Mandible, Mobile mucosa, Molar, Molar protraction, Oral impl, Orthodontic forces, Orthodontic treatment, Palatal implants, Patient compliance, Patient selection, Posterior teeth, Posterior tooth, Preliminary report, Protraction, Reactive unit, Second generation, Second premolar, Titanium, Titanium screw, Titanium sleeve, Total treatment time, Vacuum foil, Vienna university school.
Abstract
Abstract: Critical anchorage during orthodontic treatment in the mandible needs both time and effort and patient compliance. In 8 patients, 12 bicortical titanium screws (BIS) were used as anchorage units for orthodontic molar protraction. The criteria for patient selection were: critical anchorage in the lower jaw (i.e. retraction of anterior teeth undesirable) and molar extraction sites. After insertion of the screws in local anesthesia, orthodontic forces were applied immediately. One screw worked loose and had to be removed before the end of treatment. Problems encountered included impingement of the screw head and slight inflammatory reactions of the surrounding mobile mucosa, which necessitated premature removal of two screws. After healing, a new insertion site was chosen. Further treatment was uneventful. Anchorage for orthodontic forces as described offers several advantages. The total treatment time is reduced as the screws can be loaded immediately. The line of action of the orthodontic force coincides with the level of the center of resistance of the molar resulting in a favorable translatory tooth movement. Treatment does not depend on patient cooperation.
Url:
DOI: 10.1034/j.1600-0501.2001.012004358.x
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 002F71
- to stream Istex, to step Curation: 002F71
- to stream Istex, to step Checkpoint: 003C79
- to stream Main, to step Merge: 008D93
- to stream Main, to step Curation: 008A60
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications</title>
<author><name sortKey="Freudenthaler, Josef W" sort="Freudenthaler, Josef W" uniqKey="Freudenthaler J" first="Josef W." last="Freudenthaler">Josef W. Freudenthaler</name>
</author>
<author><name sortKey="Bantleon, Hans Eter" sort="Bantleon, Hans Eter" uniqKey="Bantleon H" first="Hans-Peter" last="Bantleon">Hans-Peter Bantleon</name>
</author>
<author><name sortKey="Haas, Robert" sort="Haas, Robert" uniqKey="Haas R" first="Robert" last="Haas">Robert Haas</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:6113B39DEF98AEBD68827B88D2DD440851B82F66</idno>
<date when="2001" year="2001">2001</date>
<idno type="doi">10.1034/j.1600-0501.2001.012004358.x</idno>
<idno type="url">https://api.istex.fr/document/6113B39DEF98AEBD68827B88D2DD440851B82F66/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002F71</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">002F71</idno>
<idno type="wicri:Area/Istex/Curation">002F71</idno>
<idno type="wicri:Area/Istex/Checkpoint">003C79</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">003C79</idno>
<idno type="wicri:doubleKey">0905-7161:2001:Freudenthaler J:bicortical:titanium:screws</idno>
<idno type="wicri:Area/Main/Merge">008D93</idno>
<idno type="wicri:Area/Main/Curation">008A60</idno>
<idno type="wicri:Area/Main/Exploration">008A60</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications</title>
<author><name sortKey="Freudenthaler, Josef W" sort="Freudenthaler, Josef W" uniqKey="Freudenthaler J" first="Josef W." last="Freudenthaler">Josef W. Freudenthaler</name>
<affiliation wicri:level="3"><country>Autriche</country>
<placeName><settlement type="city">Vienne (Autriche)</settlement>
<region nuts="2" type="province">Vienne (Autriche)</region>
</placeName>
<wicri:orgArea>Orthodontic Department, Vienna University School of Dentistry</wicri:orgArea>
</affiliation>
</author>
<author><name sortKey="Bantleon, Hans Eter" sort="Bantleon, Hans Eter" uniqKey="Bantleon H" first="Hans-Peter" last="Bantleon">Hans-Peter Bantleon</name>
<affiliation wicri:level="3"><country>Autriche</country>
<placeName><settlement type="city">Vienne (Autriche)</settlement>
<region nuts="2" type="province">Vienne (Autriche)</region>
</placeName>
<wicri:orgArea>Orthodontic Department, Vienna University School of Dentistry</wicri:orgArea>
</affiliation>
</author>
<author><name sortKey="Haas, Robert" sort="Haas, Robert" uniqKey="Haas R" first="Robert" last="Haas">Robert Haas</name>
<affiliation wicri:level="3"><country xml:lang="fr">Autriche</country>
<wicri:regionArea>Oral Surgery Department, Vienna University School of Dentistry, Vienna</wicri:regionArea>
<placeName><settlement type="city">Vienne (Autriche)</settlement>
<region nuts="2" type="province">Vienne (Autriche)</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint><biblScope unit="vol">12</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="358">358</biblScope>
<biblScope unit="page" to="363">363</biblScope>
<biblScope unit="page-count">6</biblScope>
<publisher>Munksgaard International Publishers</publisher>
<pubPlace>Copenhagen</pubPlace>
<date type="published" when="2001-08">2001-08</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Agenesis</term>
<term>Anchorage</term>
<term>Anchorage preparation</term>
<term>Anchorage situations</term>
<term>Anterior teeth</term>
<term>Anterior unit</term>
<term>Antirotation lever</term>
<term>Bicortical</term>
<term>Bicortical anchorage</term>
<term>Bicortical titanium screws</term>
<term>Biocortical titanium screws</term>
<term>Canine</term>
<term>Canine relation</term>
<term>Critical anchorage</term>
<term>Deciduous molar</term>
<term>Dental implants</term>
<term>Edentulous areas</term>
<term>European journal</term>
<term>Extraction site</term>
<term>Favorable translatory tooth movement</term>
<term>Force system</term>
<term>Freudenthaler</term>
<term>Further treatment</term>
<term>Immediate loading</term>
<term>Implant</term>
<term>Insertion</term>
<term>Insertion site</term>
<term>Insertion sites</term>
<term>Local anesthesia</term>
<term>Mandible</term>
<term>Mobile mucosa</term>
<term>Molar</term>
<term>Molar protraction</term>
<term>Oral impl</term>
<term>Orthodontic forces</term>
<term>Orthodontic treatment</term>
<term>Palatal implants</term>
<term>Patient compliance</term>
<term>Patient selection</term>
<term>Posterior teeth</term>
<term>Posterior tooth</term>
<term>Preliminary report</term>
<term>Protraction</term>
<term>Reactive unit</term>
<term>Second generation</term>
<term>Second premolar</term>
<term>Titanium</term>
<term>Titanium screw</term>
<term>Titanium sleeve</term>
<term>Total treatment time</term>
<term>Vacuum foil</term>
<term>Vienna university school</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Agenesis</term>
<term>Anchorage</term>
<term>Anchorage preparation</term>
<term>Anchorage situations</term>
<term>Anterior teeth</term>
<term>Anterior unit</term>
<term>Antirotation lever</term>
<term>Bicortical</term>
<term>Bicortical anchorage</term>
<term>Bicortical titanium screws</term>
<term>Biocortical titanium screws</term>
<term>Canine</term>
<term>Canine relation</term>
<term>Critical anchorage</term>
<term>Deciduous molar</term>
<term>Dental implants</term>
<term>Edentulous areas</term>
<term>European journal</term>
<term>Extraction site</term>
<term>Favorable translatory tooth movement</term>
<term>Force system</term>
<term>Freudenthaler</term>
<term>Further treatment</term>
<term>Immediate loading</term>
<term>Implant</term>
<term>Insertion</term>
<term>Insertion site</term>
<term>Insertion sites</term>
<term>Local anesthesia</term>
<term>Mandible</term>
<term>Mobile mucosa</term>
<term>Molar</term>
<term>Molar protraction</term>
<term>Oral impl</term>
<term>Orthodontic forces</term>
<term>Orthodontic treatment</term>
<term>Palatal implants</term>
<term>Patient compliance</term>
<term>Patient selection</term>
<term>Posterior teeth</term>
<term>Posterior tooth</term>
<term>Preliminary report</term>
<term>Protraction</term>
<term>Reactive unit</term>
<term>Second generation</term>
<term>Second premolar</term>
<term>Titanium</term>
<term>Titanium screw</term>
<term>Titanium sleeve</term>
<term>Total treatment time</term>
<term>Vacuum foil</term>
<term>Vienna university school</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Titane</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Abstract: Critical anchorage during orthodontic treatment in the mandible needs both time and effort and patient compliance. In 8 patients, 12 bicortical titanium screws (BIS) were used as anchorage units for orthodontic molar protraction. The criteria for patient selection were: critical anchorage in the lower jaw (i.e. retraction of anterior teeth undesirable) and molar extraction sites. After insertion of the screws in local anesthesia, orthodontic forces were applied immediately. One screw worked loose and had to be removed before the end of treatment. Problems encountered included impingement of the screw head and slight inflammatory reactions of the surrounding mobile mucosa, which necessitated premature removal of two screws. After healing, a new insertion site was chosen. Further treatment was uneventful. Anchorage for orthodontic forces as described offers several advantages. The total treatment time is reduced as the screws can be loaded immediately. The line of action of the orthodontic force coincides with the level of the center of resistance of the molar resulting in a favorable translatory tooth movement. Treatment does not depend on patient cooperation.</div>
</front>
</TEI>
<affiliations><list><country><li>Autriche</li>
</country>
<region><li>Vienne (Autriche)</li>
</region>
<settlement><li>Vienne (Autriche)</li>
</settlement>
</list>
<tree><country name="Autriche"><region name="Vienne (Autriche)"><name sortKey="Freudenthaler, Josef W" sort="Freudenthaler, Josef W" uniqKey="Freudenthaler J" first="Josef W." last="Freudenthaler">Josef W. Freudenthaler</name>
</region>
<name sortKey="Bantleon, Hans Eter" sort="Bantleon, Hans Eter" uniqKey="Bantleon H" first="Hans-Peter" last="Bantleon">Hans-Peter Bantleon</name>
<name sortKey="Haas, Robert" sort="Haas, Robert" uniqKey="Haas R" first="Robert" last="Haas">Robert Haas</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 008A60 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 008A60 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:6113B39DEF98AEBD68827B88D2DD440851B82F66 |texte= Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications }}
This area was generated with Dilib version V0.6.32. |