Predicting osseointegration by means of implant primary stability

Identifieur interne : 007934 ( Main/Exploration ); précédent : 007933; suivant : 007935

Predicting osseointegration by means of implant primary stability

Auteurs : Rabah Nedir [Suisse] ; Mark Bischof [Suisse] ; Serge Szmukler-Moncler [Suisse] ; Jean-Pierre Bernard [Suisse] ; Jacky Samson [Suisse]

Source :

RBID : ISTEX:6DC687D8C27CFB1E0B9DE1426118454454C24FDB

English descriptors

Abstract

Abstract: The purpose of the present clinical study was (1) to evaluate the Osstell as a diagnostic tool capable of differentiating between stable and mobile ITI implants, (2) to evaluate a cut‐off threshold implant stability quotient (ISQ) value obtained at implant placement (ISQitv) that might be predictive of osseointegration, (3) to compare the predictive ISQitv of immediately loaded (IL) implants and implants loaded after 3 months (DL). Two patient groups were enrolled, 18 patients received 63 IL implants and 18 patients were treated with 43 DL implants. The ISQ was recorded at implant placement, after 1, 2, 4, 6, 8, 10 and 12 weeks. All implants passed the 1‐year loading control. Two implants failed, one DL implant with ISQ at placement (ISQi) of 48 and one IL implant with ISQi of 53. The resonance‐frequency analysis (RFA) method was not a reliable diagnostic tool to identify mobile implants. However, implant stability could be reliably determined for implants displaying an ISQ≥47. After 1 year of loading, all DL implants with an ISQi≥49 and all IL implants with an ISQi≥54 achieved and maintained osseointegration. By the end of 3 months, implants with ISQi<60 had an increase of stability. Implants with ISQi 60–69 had their stability decrease during 8 weeks before returning to their initial values. Implants with ISQ>69 had their stability decrease during the first 4 weeks before remaining stable. Although preliminary, these data might orient the practitioner to choose among various loading protocols and to selectively monitor implants during the healing phase.

Url:
DOI: 10.1111/j.1600-0501.2004.01059.x


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Predicting osseointegration by means of implant primary stability</title>
<author>
<name sortKey="Nedir, Rabah" sort="Nedir, Rabah" uniqKey="Nedir R" first="Rabah" last="Nedir">Rabah Nedir</name>
</author>
<author>
<name sortKey="Bischof, Mark" sort="Bischof, Mark" uniqKey="Bischof M" first="Mark" last="Bischof">Mark Bischof</name>
</author>
<author>
<name sortKey="Szmukler Oncler, Serge" sort="Szmukler Oncler, Serge" uniqKey="Szmukler Oncler S" first="Serge" last="Szmukler-Moncler">Serge Szmukler-Moncler</name>
</author>
<author>
<name sortKey="Bernard, Jean Ierre" sort="Bernard, Jean Ierre" uniqKey="Bernard J" first="Jean-Pierre" last="Bernard">Jean-Pierre Bernard</name>
</author>
<author>
<name sortKey="Samson, Jacky" sort="Samson, Jacky" uniqKey="Samson J" first="Jacky" last="Samson">Jacky Samson</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:6DC687D8C27CFB1E0B9DE1426118454454C24FDB</idno>
<date when="2004" year="2004">2004</date>
<idno type="doi">10.1111/j.1600-0501.2004.01059.x</idno>
<idno type="url">https://api.istex.fr/document/6DC687D8C27CFB1E0B9DE1426118454454C24FDB/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">003628</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">003628</idno>
<idno type="wicri:Area/Istex/Curation">003628</idno>
<idno type="wicri:Area/Istex/Checkpoint">003193</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">003193</idno>
<idno type="wicri:doubleKey">0905-7161:2004:Nedir R:predicting:osseointegration:by</idno>
<idno type="wicri:Area/Main/Merge">007B20</idno>
<idno type="wicri:Area/Main/Curation">007934</idno>
<idno type="wicri:Area/Main/Exploration">007934</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Predicting osseointegration by means of implant primary stability</title>
<author>
<name sortKey="Nedir, Rabah" sort="Nedir, Rabah" uniqKey="Nedir R" first="Rabah" last="Nedir">Rabah Nedir</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>CdR Clinique Dentaire, Vevey</wicri:regionArea>
<wicri:noRegion>Vevey</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Department of Stomatology and Oral Surgery, School of Dental Medecine, Geneva</wicri:regionArea>
<wicri:noRegion>Geneva</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Bischof, Mark" sort="Bischof, Mark" uniqKey="Bischof M" first="Mark" last="Bischof">Mark Bischof</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>CdR Clinique Dentaire, Vevey</wicri:regionArea>
<wicri:noRegion>Vevey</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Department of Stomatology and Oral Surgery, School of Dental Medecine, Geneva</wicri:regionArea>
<wicri:noRegion>Geneva</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Szmukler Oncler, Serge" sort="Szmukler Oncler, Serge" uniqKey="Szmukler Oncler S" first="Serge" last="Szmukler-Moncler">Serge Szmukler-Moncler</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Department of Stomatology and Oral Surgery, School of Dental Medecine, Geneva</wicri:regionArea>
<wicri:noRegion>Geneva</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Bernard, Jean Ierre" sort="Bernard, Jean Ierre" uniqKey="Bernard J" first="Jean-Pierre" last="Bernard">Jean-Pierre Bernard</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Department of Stomatology and Oral Surgery, School of Dental Medecine, Geneva</wicri:regionArea>
<wicri:noRegion>Geneva</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Samson, Jacky" sort="Samson, Jacky" uniqKey="Samson J" first="Jacky" last="Samson">Jacky Samson</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Department of Stomatology and Oral Surgery, School of Dental Medecine, Geneva</wicri:regionArea>
<wicri:noRegion>Geneva</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint>
<biblScope unit="vol">15</biblScope>
<biblScope unit="issue">5</biblScope>
<biblScope unit="page" from="520">520</biblScope>
<biblScope unit="page" to="528">528</biblScope>
<biblScope unit="page-count">9</biblScope>
<publisher>Munksgaard International Publishers</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2004-10">2004-10</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Avec</term>
<term>Bischof</term>
<term>Buser</term>
<term>Clin</term>
<term>Dentistry</term>
<term>Diagnostic tool</term>
<term>Disq</term>
<term>Disqf</term>
<term>Edentulous</term>
<term>Einem</term>
<term>Einem isqi</term>
<term>Friberg</term>
<term>Healing period</term>
<term>Healing phase</term>
<term>Immediate loading</term>
<term>Impl</term>
<term>Implant</term>
<term>Implant length</term>
<term>Implant osseointegration</term>
<term>Implant placement</term>
<term>Implant stability</term>
<term>Implant stability quotient</term>
<term>Implantate</term>
<term>Implantes</term>
<term>Implants research</term>
<term>International journal</term>
<term>Isqi</term>
<term>Isqitv</term>
<term>Lekholm</term>
<term>Loading control</term>
<term>Mandible</term>
<term>Maxilla</term>
<term>Mobile implant</term>
<term>Mobile implants</term>
<term>Nedir</term>
<term>Negative results</term>
<term>Nger pressure</term>
<term>Oral impl</term>
<term>Osseointegrated</term>
<term>Osseointegration</term>
<term>Osstell</term>
<term>Positive results</term>
<term>Predictor</term>
<term>Primary stability</term>
<term>Prosthesis</term>
<term>Quotient</term>
<term>Resonance frequency analysis</term>
<term>Resonance frequency measurements</term>
<term>Sennerby</term>
<term>Stable implant</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Avec</term>
<term>Bischof</term>
<term>Buser</term>
<term>Clin</term>
<term>Dentistry</term>
<term>Diagnostic tool</term>
<term>Disq</term>
<term>Disqf</term>
<term>Edentulous</term>
<term>Einem</term>
<term>Einem isqi</term>
<term>Friberg</term>
<term>Healing period</term>
<term>Healing phase</term>
<term>Immediate loading</term>
<term>Impl</term>
<term>Implant</term>
<term>Implant length</term>
<term>Implant osseointegration</term>
<term>Implant placement</term>
<term>Implant stability</term>
<term>Implant stability quotient</term>
<term>Implantate</term>
<term>Implantes</term>
<term>Implants research</term>
<term>International journal</term>
<term>Isqi</term>
<term>Isqitv</term>
<term>Lekholm</term>
<term>Loading control</term>
<term>Mandible</term>
<term>Maxilla</term>
<term>Mobile implant</term>
<term>Mobile implants</term>
<term>Nedir</term>
<term>Negative results</term>
<term>Nger pressure</term>
<term>Oral impl</term>
<term>Osseointegrated</term>
<term>Osseointegration</term>
<term>Osstell</term>
<term>Positive results</term>
<term>Predictor</term>
<term>Primary stability</term>
<term>Prosthesis</term>
<term>Quotient</term>
<term>Resonance frequency analysis</term>
<term>Resonance frequency measurements</term>
<term>Sennerby</term>
<term>Stable implant</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">Abstract: The purpose of the present clinical study was (1) to evaluate the Osstell as a diagnostic tool capable of differentiating between stable and mobile ITI implants, (2) to evaluate a cut‐off threshold implant stability quotient (ISQ) value obtained at implant placement (ISQitv) that might be predictive of osseointegration, (3) to compare the predictive ISQitv of immediately loaded (IL) implants and implants loaded after 3 months (DL). Two patient groups were enrolled, 18 patients received 63 IL implants and 18 patients were treated with 43 DL implants. The ISQ was recorded at implant placement, after 1, 2, 4, 6, 8, 10 and 12 weeks. All implants passed the 1‐year loading control. Two implants failed, one DL implant with ISQ at placement (ISQi) of 48 and one IL implant with ISQi of 53. The resonance‐frequency analysis (RFA) method was not a reliable diagnostic tool to identify mobile implants. However, implant stability could be reliably determined for implants displaying an ISQ≥47. After 1 year of loading, all DL implants with an ISQi≥49 and all IL implants with an ISQi≥54 achieved and maintained osseointegration. By the end of 3 months, implants with ISQi<60 had an increase of stability. Implants with ISQi 60–69 had their stability decrease during 8 weeks before returning to their initial values. Implants with ISQ>69 had their stability decrease during the first 4 weeks before remaining stable. Although preliminary, these data might orient the practitioner to choose among various loading protocols and to selectively monitor implants during the healing phase.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Suisse</li>
</country>
</list>
<tree>
<country name="Suisse">
<noRegion>
<name sortKey="Nedir, Rabah" sort="Nedir, Rabah" uniqKey="Nedir R" first="Rabah" last="Nedir">Rabah Nedir</name>
</noRegion>
<name sortKey="Bernard, Jean Ierre" sort="Bernard, Jean Ierre" uniqKey="Bernard J" first="Jean-Pierre" last="Bernard">Jean-Pierre Bernard</name>
<name sortKey="Bischof, Mark" sort="Bischof, Mark" uniqKey="Bischof M" first="Mark" last="Bischof">Mark Bischof</name>
<name sortKey="Bischof, Mark" sort="Bischof, Mark" uniqKey="Bischof M" first="Mark" last="Bischof">Mark Bischof</name>
<name sortKey="Nedir, Rabah" sort="Nedir, Rabah" uniqKey="Nedir R" first="Rabah" last="Nedir">Rabah Nedir</name>
<name sortKey="Samson, Jacky" sort="Samson, Jacky" uniqKey="Samson J" first="Jacky" last="Samson">Jacky Samson</name>
<name sortKey="Szmukler Oncler, Serge" sort="Szmukler Oncler, Serge" uniqKey="Szmukler Oncler S" first="Serge" last="Szmukler-Moncler">Serge Szmukler-Moncler</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 007934 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 007934 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:6DC687D8C27CFB1E0B9DE1426118454454C24FDB
   |texte=   Predicting osseointegration by means of implant primary stability
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022