Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a synthetic edentulous lower jaw model.

Identifieur interne : 007245 ( Main/Exploration ); précédent : 007244; suivant : 007246

Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a synthetic edentulous lower jaw model.

Auteurs : Jürgen Hoffmann [Allemagne] ; Carsten Westendorff ; German Gomez-Roman ; Siegmar Reinert

Source :

RBID : pubmed:16164469

Descripteurs français

English descriptors

Abstract

In this study, the three-dimensional (3D) accuracy of navigation-guided (NG) socket drilling before implant installation was compared to the conventional free-hand (CF) method in a synthetic edentulous lower jaw model. The drillings were performed by two surgeons with different years of working experience. The inter-individual outcome was assessed. NG drillings were performed using an optical computerized tomography (CT)-based navigation system. CF drillings were performed using a surgical template. The coordinates of the drilled sockets were determined on the basis of CT scans. A total of n=224 drillings was evaluated. Inter-individual differences in terms of the surgeons' years of work experience were without statistical significance. The mean deviation of the CF drilled sockets (n=112) on the vestibulo-oral and mesio-distal direction was 11.2+/-5.6 degrees (range: 4.1-25.3 degrees ). With respect to the NG drilled sockets (n=112), the mean deviation was 4.2+/-1.8 degrees (range: 2.3-11.5). The mean distance to the mandibular canal was 1.1+/-0.6 mm (range: 0.1-2.3 mm) for CF-drilled sockets and 0.7+/-0.5 mm (range: 0.1-1.8 mm) for NG drilled sockets. The differences between the two methods were highly significant (P<0.01). A potential benefit from image-data-based navigation in implant surgery is discussed against the background of cost-effectiveness.

DOI: 10.1111/j.1600-0501.2005.01153.x
PubMed: 16164469


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a synthetic edentulous lower jaw model.</title>
<author>
<name sortKey="Hoffmann, Jurgen" sort="Hoffmann, Jurgen" uniqKey="Hoffmann J" first="Jürgen" last="Hoffmann">Jürgen Hoffmann</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Tübingen University Hospital, Tübingen, Germany. juergen.hoffmann@uni-tuebingen.de</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Tübingen University Hospital, Tübingen</wicri:regionArea>
<placeName>
<region type="land" nuts="1">Bade-Wurtemberg</region>
<region type="district" nuts="2">District de Tübingen</region>
<settlement type="city">Tübingen</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Westendorff, Carsten" sort="Westendorff, Carsten" uniqKey="Westendorff C" first="Carsten" last="Westendorff">Carsten Westendorff</name>
</author>
<author>
<name sortKey="Gomez Roman, German" sort="Gomez Roman, German" uniqKey="Gomez Roman G" first="German" last="Gomez-Roman">German Gomez-Roman</name>
</author>
<author>
<name sortKey="Reinert, Siegmar" sort="Reinert, Siegmar" uniqKey="Reinert S" first="Siegmar" last="Reinert">Siegmar Reinert</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2005">2005</date>
<idno type="RBID">pubmed:16164469</idno>
<idno type="pmid">16164469</idno>
<idno type="doi">10.1111/j.1600-0501.2005.01153.x</idno>
<idno type="wicri:Area/PubMed/Corpus">002903</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002903</idno>
<idno type="wicri:Area/PubMed/Curation">002903</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">002903</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002903</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">002903</idno>
<idno type="wicri:Area/Ncbi/Merge">001792</idno>
<idno type="wicri:Area/Ncbi/Curation">001792</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001792</idno>
<idno type="wicri:doubleKey">0905-7161:2005:Hoffmann J:accuracy:of:navigation</idno>
<idno type="wicri:Area/Main/Merge">007391</idno>
<idno type="wicri:Area/Main/Curation">007245</idno>
<idno type="wicri:Area/Main/Exploration">007245</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a synthetic edentulous lower jaw model.</title>
<author>
<name sortKey="Hoffmann, Jurgen" sort="Hoffmann, Jurgen" uniqKey="Hoffmann J" first="Jürgen" last="Hoffmann">Jürgen Hoffmann</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, Tübingen University Hospital, Tübingen, Germany. juergen.hoffmann@uni-tuebingen.de</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Tübingen University Hospital, Tübingen</wicri:regionArea>
<placeName>
<region type="land" nuts="1">Bade-Wurtemberg</region>
<region type="district" nuts="2">District de Tübingen</region>
<settlement type="city">Tübingen</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Westendorff, Carsten" sort="Westendorff, Carsten" uniqKey="Westendorff C" first="Carsten" last="Westendorff">Carsten Westendorff</name>
</author>
<author>
<name sortKey="Gomez Roman, German" sort="Gomez Roman, German" uniqKey="Gomez Roman G" first="German" last="Gomez-Roman">German Gomez-Roman</name>
</author>
<author>
<name sortKey="Reinert, Siegmar" sort="Reinert, Siegmar" uniqKey="Reinert S" first="Siegmar" last="Reinert">Siegmar Reinert</name>
</author>
</analytic>
<series>
<title level="j">Clinical oral implants research</title>
<idno type="ISSN">0905-7161</idno>
<imprint>
<date when="2005" type="published">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Analysis of Variance</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Humans</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Mandible (surgery)</term>
<term>Surgery, Computer-Assisted (methods)</term>
<term>Tomography, X-Ray Computed</term>
<term>Tooth Socket</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Alvéole dentaire</term>
<term>Analyse de variance</term>
<term>Chirurgie assistée par ordinateur ()</term>
<term>Humains</term>
<term>Mandibule ()</term>
<term>Mâchoire édentée ()</term>
<term>Pose d'implant dentaire endo-osseux ()</term>
<term>Tomodensitométrie</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Analysis of Variance</term>
<term>Humans</term>
<term>Tomography, X-Ray Computed</term>
<term>Tooth Socket</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Alvéole dentaire</term>
<term>Analyse de variance</term>
<term>Chirurgie assistée par ordinateur</term>
<term>Humains</term>
<term>Mandibule</term>
<term>Mâchoire édentée</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Tomodensitométrie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In this study, the three-dimensional (3D) accuracy of navigation-guided (NG) socket drilling before implant installation was compared to the conventional free-hand (CF) method in a synthetic edentulous lower jaw model. The drillings were performed by two surgeons with different years of working experience. The inter-individual outcome was assessed. NG drillings were performed using an optical computerized tomography (CT)-based navigation system. CF drillings were performed using a surgical template. The coordinates of the drilled sockets were determined on the basis of CT scans. A total of n=224 drillings was evaluated. Inter-individual differences in terms of the surgeons' years of work experience were without statistical significance. The mean deviation of the CF drilled sockets (n=112) on the vestibulo-oral and mesio-distal direction was 11.2+/-5.6 degrees (range: 4.1-25.3 degrees ). With respect to the NG drilled sockets (n=112), the mean deviation was 4.2+/-1.8 degrees (range: 2.3-11.5). The mean distance to the mandibular canal was 1.1+/-0.6 mm (range: 0.1-2.3 mm) for CF-drilled sockets and 0.7+/-0.5 mm (range: 0.1-1.8 mm) for NG drilled sockets. The differences between the two methods were highly significant (P<0.01). A potential benefit from image-data-based navigation in implant surgery is discussed against the background of cost-effectiveness.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
<region>
<li>Bade-Wurtemberg</li>
<li>District de Tübingen</li>
</region>
<settlement>
<li>Tübingen</li>
</settlement>
</list>
<tree>
<noCountry>
<name sortKey="Gomez Roman, German" sort="Gomez Roman, German" uniqKey="Gomez Roman G" first="German" last="Gomez-Roman">German Gomez-Roman</name>
<name sortKey="Reinert, Siegmar" sort="Reinert, Siegmar" uniqKey="Reinert S" first="Siegmar" last="Reinert">Siegmar Reinert</name>
<name sortKey="Westendorff, Carsten" sort="Westendorff, Carsten" uniqKey="Westendorff C" first="Carsten" last="Westendorff">Carsten Westendorff</name>
</noCountry>
<country name="Allemagne">
<region name="Bade-Wurtemberg">
<name sortKey="Hoffmann, Jurgen" sort="Hoffmann, Jurgen" uniqKey="Hoffmann J" first="Jürgen" last="Hoffmann">Jürgen Hoffmann</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 007245 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 007245 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:16164469
   |texte=   Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a synthetic edentulous lower jaw model.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:16164469" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022