The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study

Identifieur interne : 004E73 ( Main/Exploration ); précédent : 004E72; suivant : 004E74

The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study

Auteurs : Young-Moon Cho [Corée du Sud] ; Jung-Yul Cha [Corée du Sud] ; Chung-Ju Hwang [Corée du Sud]

Source :

RBID : ISTEX:551BA380E1027799FA64F6773F66C42959C5DE85

Abstract

The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability. In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil springs with either a clockwise or counterclockwise rotation moment while 12 miniscrews were left unloaded. Following an observation period of 3 or 12 weeks, the animals were killed and the miniscrews with the surrounding bone were prepared for histomorphometric evaluation. Bone-to-implant contact (BIC) and the ratio of bone volume/total volume (BV/TV) were measured. BIC and BV/TV were statistically compared using the Kruskal–Wallis H and Mann–Whitney U tests. Three of the miniscrews loaded with 2 Ncm counterclockwise rotation moment were lost within 3 weeks. At 12 weeks after insertion, the counterclockwise group showed a statistically significantly lower BIC in comparison with the clockwise group. The results suggest that a rotation moment to loaded orthodontic miniscrews, as well as the direction and magnitude of the rotation moment, can influence miniscrew stability. Counterclockwise rotational moments can be a risk factor impairing miniscrew stability.

Url:
DOI: 10.1093/ejo/cjq008


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study</title>
<author>
<name sortKey="Cho, Young Moon" sort="Cho, Young Moon" uniqKey="Cho Y" first="Young-Moon" last="Cho">Young-Moon Cho</name>
</author>
<author>
<name sortKey="Cha, Jung Yul" sort="Cha, Jung Yul" uniqKey="Cha J" first="Jung-Yul" last="Cha">Jung-Yul Cha</name>
</author>
<author>
<name sortKey="Hwang, Chung Ju" sort="Hwang, Chung Ju" uniqKey="Hwang C" first="Chung-Ju" last="Hwang">Chung-Ju Hwang</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:551BA380E1027799FA64F6773F66C42959C5DE85</idno>
<date when="2010" year="2010">2010</date>
<idno type="doi">10.1093/ejo/cjq008</idno>
<idno type="url">https://api.istex.fr/document/551BA380E1027799FA64F6773F66C42959C5DE85/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002990</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">002990</idno>
<idno type="wicri:Area/Istex/Curation">002990</idno>
<idno type="wicri:Area/Istex/Checkpoint">001975</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001975</idno>
<idno type="wicri:doubleKey">0141-5387:2010:Cho Y:the:effect:of</idno>
<idno type="wicri:Area/Main/Merge">004F14</idno>
<idno type="wicri:Area/Main/Curation">004E73</idno>
<idno type="wicri:Area/Main/Exploration">004E73</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study</title>
<author>
<name sortKey="Cho, Young Moon" sort="Cho, Young Moon" uniqKey="Cho Y" first="Young-Moon" last="Cho">Young-Moon Cho</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>Private Clinic, Seoul</wicri:regionArea>
<placeName>
<settlement type="city">Séoul</settlement>
<region type="capital">Région capitale de Séoul</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Cha, Jung Yul" sort="Cha, Jung Yul" uniqKey="Cha J" first="Jung-Yul" last="Cha">Jung-Yul Cha</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>Department of Orthodontics, College of Dentistry, Oral Science Research Center, The Institute of Cranio-facial Deformity, Yonsei University, Seoul</wicri:regionArea>
<placeName>
<settlement type="city">Séoul</settlement>
<region type="capital">Région capitale de Séoul</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Hwang, Chung Ju" sort="Hwang, Chung Ju" uniqKey="Hwang C" first="Chung-Ju" last="Hwang">Chung-Ju Hwang</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>Department of Orthodontics, College of Dentistry, Oral Science Research Center, The Institute of Cranio-facial Deformity, Yonsei University, Seoul</wicri:regionArea>
<placeName>
<settlement type="city">Séoul</settlement>
<region type="capital">Région capitale de Séoul</region>
</placeName>
</affiliation>
<affiliation></affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">The European Journal of Orthodontics</title>
<idno type="ISSN">0141-5387</idno>
<idno type="eISSN">1460-2210</idno>
<imprint>
<publisher>Oxford University Press</publisher>
<date type="published" when="2010-12">2010-12</date>
<biblScope unit="volume">32</biblScope>
<biblScope unit="issue">6</biblScope>
<biblScope unit="page" from="614">614</biblScope>
<biblScope unit="page" to="619">619</biblScope>
</imprint>
<idno type="ISSN">0141-5387</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0141-5387</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability. In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil springs with either a clockwise or counterclockwise rotation moment while 12 miniscrews were left unloaded. Following an observation period of 3 or 12 weeks, the animals were killed and the miniscrews with the surrounding bone were prepared for histomorphometric evaluation. Bone-to-implant contact (BIC) and the ratio of bone volume/total volume (BV/TV) were measured. BIC and BV/TV were statistically compared using the Kruskal–Wallis H and Mann–Whitney U tests. Three of the miniscrews loaded with 2 Ncm counterclockwise rotation moment were lost within 3 weeks. At 12 weeks after insertion, the counterclockwise group showed a statistically significantly lower BIC in comparison with the clockwise group. The results suggest that a rotation moment to loaded orthodontic miniscrews, as well as the direction and magnitude of the rotation moment, can influence miniscrew stability. Counterclockwise rotational moments can be a risk factor impairing miniscrew stability.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Corée du Sud</li>
</country>
<region>
<li>Région capitale de Séoul</li>
</region>
<settlement>
<li>Séoul</li>
</settlement>
</list>
<tree>
<country name="Corée du Sud">
<region name="Région capitale de Séoul">
<name sortKey="Cho, Young Moon" sort="Cho, Young Moon" uniqKey="Cho Y" first="Young-Moon" last="Cho">Young-Moon Cho</name>
</region>
<name sortKey="Cha, Jung Yul" sort="Cha, Jung Yul" uniqKey="Cha J" first="Jung-Yul" last="Cha">Jung-Yul Cha</name>
<name sortKey="Hwang, Chung Ju" sort="Hwang, Chung Ju" uniqKey="Hwang C" first="Chung-Ju" last="Hwang">Chung-Ju Hwang</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004E73 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 004E73 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:551BA380E1027799FA64F6773F66C42959C5DE85
   |texte=   The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022