Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Deflections of an implant‐supported cantilever beam subjected to vertically directed loads: in vitro measurements in three dimensions using an optoelectronic method. I. Experimental set‐up

Identifieur interne : 004882 ( Main/Exploration ); précédent : 004881; suivant : 004883

Deflections of an implant‐supported cantilever beam subjected to vertically directed loads: in vitro measurements in three dimensions using an optoelectronic method. I. Experimental set‐up

Auteurs : Björn Cassel [Suède] ; Dan Lundgren [Suède] ; Dan Karlsson [Suède]

Source :

RBID : ISTEX:C80290D0BE3EE516D75DF4213F5716461BA5B054

English descriptors

Abstract

Aim: The aim of this in vitro study was to develop and test an experimental set‐up consisting of a video camera and computer‐based optoelectronic motion analysis system, synchronized with a loading device, for studying load‐dependent deflections in three dimensions of single implant‐supported cantilever beams.

Url:
DOI: 10.1111/j.1600-0501.2010.01991.x


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Deflections of an implant‐supported cantilever beam subjected to vertically directed loads: in vitro measurements in three dimensions using an optoelectronic method. I. Experimental set‐up</title>
<author>
<name sortKey="Cassel, Bjorn" sort="Cassel, Bjorn" uniqKey="Cassel B" first="Björn" last="Cassel">Björn Cassel</name>
</author>
<author>
<name sortKey="Lundgren, Dan" sort="Lundgren, Dan" uniqKey="Lundgren D" first="Dan" last="Lundgren">Dan Lundgren</name>
</author>
<author>
<name sortKey="Karlsson, Dan" sort="Karlsson, Dan" uniqKey="Karlsson D" first="Dan" last="Karlsson">Dan Karlsson</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:C80290D0BE3EE516D75DF4213F5716461BA5B054</idno>
<date when="2011" year="2011">2011</date>
<idno type="doi">10.1111/j.1600-0501.2010.01991.x</idno>
<idno type="url">https://api.istex.fr/document/C80290D0BE3EE516D75DF4213F5716461BA5B054/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">006343</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">006343</idno>
<idno type="wicri:Area/Istex/Curation">006343</idno>
<idno type="wicri:Area/Istex/Checkpoint">001827</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001827</idno>
<idno type="wicri:doubleKey">0905-7161:2011:Cassel B:deflections:of:an</idno>
<idno type="wicri:Area/Main/Merge">004911</idno>
<idno type="wicri:Area/Main/Curation">004882</idno>
<idno type="wicri:Area/Main/Exploration">004882</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Deflections of an implant‐supported cantilever beam subjected to vertically directed loads:
<hi rend="italic">in vitro</hi>
measurements in three dimensions using an optoelectronic method. I. Experimental set‐up</title>
<author>
<name sortKey="Cassel, Bjorn" sort="Cassel, Bjorn" uniqKey="Cassel B" first="Björn" last="Cassel">Björn Cassel</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Periodontology, The Institute for Postgraduate Dental Education, Jönköping and Institute for Clinical Sciences, Department of Biomaterials, Göteborg University, Göteborg</wicri:regionArea>
<orgName type="university">Université de Göteborg</orgName>
<placeName>
<settlement type="city">Göteborg</settlement>
<region nuts="1">Götaland</region>
<region nuts="1">Suède occidentale</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Lundgren, Dan" sort="Lundgren, Dan" uniqKey="Lundgren D" first="Dan" last="Lundgren">Dan Lundgren</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Periodontology, The Institute for Postgraduate Dental Education, Jönköping and Institute for Clinical Sciences, Department of Biomaterials, Göteborg University, Göteborg</wicri:regionArea>
<orgName type="university">Université de Göteborg</orgName>
<placeName>
<settlement type="city">Göteborg</settlement>
<region nuts="1">Götaland</region>
<region nuts="1">Suède occidentale</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Karlsson, Dan" sort="Karlsson, Dan" uniqKey="Karlsson D" first="Dan" last="Karlsson">Dan Karlsson</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Biomechanics and Orthopaedic Technology, University College of Health Sciences, Jönköping</wicri:regionArea>
<wicri:noRegion>Jönköping</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint>
<biblScope unit="vol">22</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="275">275</biblScope>
<biblScope unit="page" to="281">281</biblScope>
<biblScope unit="page-count">7</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2011-03">2011-03</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Abutment</term>
<term>Abutment screw</term>
<term>Calibration frame</term>
<term>Cantilever</term>
<term>Cantilever beam</term>
<term>Cantilever loads</term>
<term>Cantilevered prosthetic beam</term>
<term>Cassel</term>
<term>Clin</term>
<term>Clinical periodontology</term>
<term>Complication rates</term>
<term>Dynamic fatigue properties</term>
<term>Edentulous jaws</term>
<term>Edentulous patients</term>
<term>Endosseous implants</term>
<term>Entire implant</term>
<term>Force transducer</term>
<term>Gold cylinder</term>
<term>Gold screw</term>
<term>Gunne</term>
<term>Hamborg karlsson</term>
<term>Horizontal plane</term>
<term>Horizontal position</term>
<term>Impl</term>
<term>Implant</term>
<term>Implant components</term>
<term>Implants research</term>
<term>International journal</term>
<term>John wiley sons</term>
<term>Karlsson</term>
<term>Limited measurement volume</term>
<term>Load levels</term>
<term>Loading device</term>
<term>Long axis</term>
<term>Lundgren</term>
<term>Lundgren laurell</term>
<term>Macintosh computer</term>
<term>Measurement volume</term>
<term>Motion analysis system</term>
<term>Natural teeth</term>
<term>Natural tooth</term>
<term>Nemark implant</term>
<term>Nobel biocare</term>
<term>Observation period</term>
<term>Occlusal forces</term>
<term>Optoelectronic</term>
<term>Optoelectronic measurements</term>
<term>Optoelectronic method</term>
<term>Optoelectronic motion analysis system</term>
<term>Oral impl</term>
<term>Oral maxillofacial implants</term>
<term>Oral rehabilitation</term>
<term>Osseointegrated implants</term>
<term>Partial dentures</term>
<term>Periodontal disease</term>
<term>Prospective study</term>
<term>Prosthesis</term>
<term>Prosthetic</term>
<term>Prosthetic beam</term>
<term>Prosthetic components</term>
<term>Prosthetic dentistry</term>
<term>Prosthetic gold screw</term>
<term>Rangert</term>
<term>Same computer</term>
<term>Satisfactory registrations</term>
<term>Screw joints</term>
<term>Spatial resolution</term>
<term>Steel plate</term>
<term>Subsequent paper</term>
<term>Systematic review</term>
<term>Technical complications</term>
<term>Test table</term>
<term>Time scale</term>
<term>Torque controller</term>
<term>Upper surface</term>
<term>Vertical loading</term>
<term>Vertical loads</term>
<term>Video</term>
<term>Video camera</term>
<term>Video cameras</term>
<term>Video processors</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Abutment</term>
<term>Abutment screw</term>
<term>Calibration frame</term>
<term>Cantilever</term>
<term>Cantilever beam</term>
<term>Cantilever loads</term>
<term>Cantilevered prosthetic beam</term>
<term>Cassel</term>
<term>Clin</term>
<term>Clinical periodontology</term>
<term>Complication rates</term>
<term>Dynamic fatigue properties</term>
<term>Edentulous jaws</term>
<term>Edentulous patients</term>
<term>Endosseous implants</term>
<term>Entire implant</term>
<term>Force transducer</term>
<term>Gold cylinder</term>
<term>Gold screw</term>
<term>Gunne</term>
<term>Hamborg karlsson</term>
<term>Horizontal plane</term>
<term>Horizontal position</term>
<term>Impl</term>
<term>Implant</term>
<term>Implant components</term>
<term>Implants research</term>
<term>International journal</term>
<term>John wiley sons</term>
<term>Karlsson</term>
<term>Limited measurement volume</term>
<term>Load levels</term>
<term>Loading device</term>
<term>Long axis</term>
<term>Lundgren</term>
<term>Lundgren laurell</term>
<term>Macintosh computer</term>
<term>Measurement volume</term>
<term>Motion analysis system</term>
<term>Natural teeth</term>
<term>Natural tooth</term>
<term>Nemark implant</term>
<term>Nobel biocare</term>
<term>Observation period</term>
<term>Occlusal forces</term>
<term>Optoelectronic</term>
<term>Optoelectronic measurements</term>
<term>Optoelectronic method</term>
<term>Optoelectronic motion analysis system</term>
<term>Oral impl</term>
<term>Oral maxillofacial implants</term>
<term>Oral rehabilitation</term>
<term>Osseointegrated implants</term>
<term>Partial dentures</term>
<term>Periodontal disease</term>
<term>Prospective study</term>
<term>Prosthesis</term>
<term>Prosthetic</term>
<term>Prosthetic beam</term>
<term>Prosthetic components</term>
<term>Prosthetic dentistry</term>
<term>Prosthetic gold screw</term>
<term>Rangert</term>
<term>Same computer</term>
<term>Satisfactory registrations</term>
<term>Screw joints</term>
<term>Spatial resolution</term>
<term>Steel plate</term>
<term>Subsequent paper</term>
<term>Systematic review</term>
<term>Technical complications</term>
<term>Test table</term>
<term>Time scale</term>
<term>Torque controller</term>
<term>Upper surface</term>
<term>Vertical loading</term>
<term>Vertical loads</term>
<term>Video</term>
<term>Video camera</term>
<term>Video cameras</term>
<term>Video processors</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">Aim: The aim of this in vitro study was to develop and test an experimental set‐up consisting of a video camera and computer‐based optoelectronic motion analysis system, synchronized with a loading device, for studying load‐dependent deflections in three dimensions of single implant‐supported cantilever beams.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Suède</li>
</country>
<region>
<li>Götaland</li>
<li>Suède occidentale</li>
</region>
<settlement>
<li>Göteborg</li>
</settlement>
<orgName>
<li>Université de Göteborg</li>
</orgName>
</list>
<tree>
<country name="Suède">
<region name="Götaland">
<name sortKey="Cassel, Bjorn" sort="Cassel, Bjorn" uniqKey="Cassel B" first="Björn" last="Cassel">Björn Cassel</name>
</region>
<name sortKey="Karlsson, Dan" sort="Karlsson, Dan" uniqKey="Karlsson D" first="Dan" last="Karlsson">Dan Karlsson</name>
<name sortKey="Lundgren, Dan" sort="Lundgren, Dan" uniqKey="Lundgren D" first="Dan" last="Lundgren">Dan Lundgren</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004882 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 004882 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:C80290D0BE3EE516D75DF4213F5716461BA5B054
   |texte=   Deflections of an implant‐supported cantilever beam subjected to vertically directed loads: in vitro measurements in three dimensions using an optoelectronic method. I. Experimental set‐up
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022