Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls
Identifieur interne : 003327 ( Main/Exploration ); précédent : 003326; suivant : 003328Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls
Auteurs : Asmáa A. Al-EkrishSource :
- The Saudi Dental Journal [ 1013-9052 ] ; 2012.
Abstract
To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images.
CBCT reformatted images of five skulls were obtained using 40, 20 and 7 s exposure protocols. From these protocols, edentulous ridge dimensions were recorded by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra- and inter-examiner reliability were calculated for each exposure protocol and compared with each other.
The mean absolute errors from the 40, 20 and 7 s protocols were 0.50, 0.46, and 0.51 mm, respectively. The intra-examiner reliability scores were 0.996, 0.995 and 0.998, respectively. The inter-examiner reliability scores were 0.993, 0.998 and 0.994, respectively. There was no significant difference in accuracy or reliability between the three protocols.
In imaging of dry skulls, lowering the CBCT exposure time from 40 s to 20 or 7 s does not affect the reliability or accuracy of implant site measurements.
Url:
DOI: 10.1016/j.sdentj.2012.05.001
PubMed: 23960541
PubMed Central: 3729286
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Pmc, to step Corpus: 002564
- to stream Pmc, to step Curation: 002564
- to stream Pmc, to step Checkpoint: 001E94
- to stream Ncbi, to step Merge: 004921
- to stream Ncbi, to step Curation: 004921
- to stream Ncbi, to step Checkpoint: 004921
- to stream Main, to step Merge: 003342
- to stream Main, to step Curation: 003327
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls</title>
<author><name sortKey="Al Ekrish, Asmaa A" sort="Al Ekrish, Asmaa A" uniqKey="Al Ekrish A" first="Asmáa A." last="Al-Ekrish">Asmáa A. Al-Ekrish</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmid">23960541</idno>
<idno type="pmc">3729286</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729286</idno>
<idno type="RBID">PMC:3729286</idno>
<idno type="doi">10.1016/j.sdentj.2012.05.001</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">002564</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">002564</idno>
<idno type="wicri:Area/Pmc/Curation">002564</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">002564</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001E94</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">001E94</idno>
<idno type="wicri:Area/Ncbi/Merge">004921</idno>
<idno type="wicri:Area/Ncbi/Curation">004921</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004921</idno>
<idno type="wicri:doubleKey">1013-9052:2012:Al Ekrish A:effect:of:exposure</idno>
<idno type="wicri:Area/Main/Merge">003342</idno>
<idno type="wicri:Area/Main/Curation">003327</idno>
<idno type="wicri:Area/Main/Exploration">003327</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls</title>
<author><name sortKey="Al Ekrish, Asmaa A" sort="Al Ekrish, Asmaa A" uniqKey="Al Ekrish A" first="Asmáa A." last="Al-Ekrish">Asmáa A. Al-Ekrish</name>
</author>
</analytic>
<series><title level="j">The Saudi Dental Journal</title>
<idno type="ISSN">1013-9052</idno>
<imprint><date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><sec><title>Objectives</title>
<p>To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images.</p>
</sec>
<sec><title>Methods</title>
<p>CBCT reformatted images of five skulls were obtained using 40, 20 and 7 s exposure protocols. From these protocols, edentulous ridge dimensions were recorded by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra- and inter-examiner reliability were calculated for each exposure protocol and compared with each other.</p>
</sec>
<sec><title>Results</title>
<p>The mean absolute errors from the 40, 20 and 7 s protocols were 0.50, 0.46, and 0.51 mm, respectively. The intra-examiner reliability scores were 0.996, 0.995 and 0.998, respectively. The inter-examiner reliability scores were 0.993, 0.998 and 0.994, respectively. There was no significant difference in accuracy or reliability between the three protocols.</p>
</sec>
<sec><title>Conclusions</title>
<p>In imaging of dry skulls, lowering the CBCT exposure time from 40 s to 20 or 7 s does not affect the reliability or accuracy of implant site measurements.</p>
</sec>
</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Al Ekrish, Asmaa A" sort="Al Ekrish, Asmaa A" uniqKey="Al Ekrish A" first="Asmáa A." last="Al-Ekrish">Asmáa A. Al-Ekrish</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003327 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003327 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Exploration |type= RBID |clé= PMC:3729286 |texte= Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:23960541" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |