Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The Effect of Different Restorative and Abutment Materials on Marginal and Internal Adaptation of Three‐Unit Cantilever Implant‐Supported Fixed Partial Dentures: An In Vitro Study

Identifieur interne : 002867 ( Main/Exploration ); précédent : 002866; suivant : 002868

The Effect of Different Restorative and Abutment Materials on Marginal and Internal Adaptation of Three‐Unit Cantilever Implant‐Supported Fixed Partial Dentures: An In Vitro Study

Auteurs : Erkut Kahramano Lu [Turquie] ; Yasemin Kulak-Özkan [Turquie]

Source :

RBID : ISTEX:CE327B708685711FF4B7BB5985DC312349E43CE4

Descripteurs français

English descriptors

Abstract

Passive fit is generally assumed to be a significant prerequisite for long‐term implant success. The aim of this study was to evaluate the precision fit of three‐unit implant‐supported fixed partial dentures with different restorative and abutment materials on two implant systems: the Straumann and Astra Tech.

Url:
DOI: 10.1111/jopr.12060


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The Effect of Different Restorative and Abutment Materials on Marginal and Internal Adaptation of Three‐Unit Cantilever Implant‐Supported Fixed Partial Dentures: An In Vitro Study</title>
<author>
<name sortKey="Kahramano Lu, Erkut" sort="Kahramano Lu, Erkut" uniqKey="Kahramano Lu E" first="Erkut" last="Kahramano Lu">Erkut Kahramano Lu</name>
</author>
<author>
<name sortKey="Kulak Kan, Yasemin" sort="Kulak Kan, Yasemin" uniqKey="Kulak Kan Y" first="Yasemin" last="Kulak-Özkan">Yasemin Kulak-Özkan</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:CE327B708685711FF4B7BB5985DC312349E43CE4</idno>
<date when="2013" year="2013">2013</date>
<idno type="doi">10.1111/jopr.12060</idno>
<idno type="url">https://api.istex.fr/document/CE327B708685711FF4B7BB5985DC312349E43CE4/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">006648</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">006648</idno>
<idno type="wicri:Area/Istex/Curation">006648</idno>
<idno type="wicri:Area/Istex/Checkpoint">000420</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000420</idno>
<idno type="wicri:doubleKey">1059-941X:2013:Kahramano Lu E:the:effect:of</idno>
<idno type="wicri:Area/Main/Merge">002879</idno>
<idno type="wicri:Area/Main/Curation">002867</idno>
<idno type="wicri:Area/Main/Exploration">002867</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">The Effect of Different Restorative and Abutment Materials on Marginal and Internal Adaptation of Three‐Unit Cantilever Implant‐Supported Fixed Partial Dentures: An In Vitro Study</title>
<author>
<name sortKey="Kahramano Lu, Erkut" sort="Kahramano Lu, Erkut" uniqKey="Kahramano Lu E" first="Erkut" last="Kahramano Lu">Erkut Kahramano Lu</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Research Assistant, University of Marmara, Department of Prosthetic Dentistry, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
<affiliation></affiliation>
<affiliation></affiliation>
</author>
<author>
<name sortKey="Kulak Kan, Yasemin" sort="Kulak Kan, Yasemin" uniqKey="Kulak Kan Y" first="Yasemin" last="Kulak-Özkan">Yasemin Kulak-Özkan</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Professor and Chairman, University of Marmara, Department of Prosthetic Dentistry, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Journal of Prosthodontics</title>
<title level="j" type="alt">JOURNAL OF PROSTHODONTICS</title>
<idno type="ISSN">1059-941X</idno>
<idno type="eISSN">1532-849X</idno>
<imprint>
<biblScope unit="vol">22</biblScope>
<biblScope unit="issue">8</biblScope>
<biblScope unit="page" from="608">608</biblScope>
<biblScope unit="page" to="617">617</biblScope>
<biblScope unit="page-count">10</biblScope>
<date type="published" when="2013-12">2013-12</date>
</imprint>
<idno type="ISSN">1059-941X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1059-941X</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Abutment</term>
<term>Abutment materials</term>
<term>Amann girrbach</term>
<term>American college</term>
<term>Anisotropic shrinkage</term>
<term>Area groups</term>
<term>Astra</term>
<term>Astra group</term>
<term>Astra implants</term>
<term>Astra tech</term>
<term>Astra tech implant system</term>
<term>Axial</term>
<term>Axial measurement</term>
<term>Axial measurements</term>
<term>Base alloy</term>
<term>Ceramic veneering</term>
<term>Cerec zirconia</term>
<term>Dent</term>
<term>Dental prostheses</term>
<term>Denture</term>
<term>Fpd</term>
<term>Fpds table</term>
<term>Framework</term>
<term>Gr1a</term>
<term>Gr1i</term>
<term>Gr1i gr1a gr2i gr2a gr3i gr3a</term>
<term>Gr2a</term>
<term>Gr2i</term>
<term>Gr3a</term>
<term>Gr3i</term>
<term>Highest values</term>
<term>Implant</term>
<term>Implant abutments</term>
<term>Implant framework</term>
<term>Implant system</term>
<term>Implant systems</term>
<term>Impression material</term>
<term>Internal adaptation</term>
<term>Kahramanoglu</term>
<term>Lambda</term>
<term>Lambda trace</term>
<term>Lavatm system</term>
<term>Manufacturing conditions</term>
<term>Marginal adaptation</term>
<term>Marginal discrepancies</term>
<term>Marginal discrepancy</term>
<term>Marginal measurements</term>
<term>Marginal region</term>
<term>Metal framework</term>
<term>Nger pressure</term>
<term>Occlusal</term>
<term>Occlusal measurements</term>
<term>Occlusal surface</term>
<term>Oral maxillofac implants</term>
<term>Osseointegrated</term>
<term>Partial dentures</term>
<term>Precious alloy</term>
<term>Present study</term>
<term>Procera</term>
<term>Prosthesis</term>
<term>Prosthet</term>
<term>Prosthet dent</term>
<term>Prosthodontics</term>
<term>Prosthodontist</term>
<term>Prosthodontists kahramanoglu</term>
<term>Replica</term>
<term>Restorative materials</term>
<term>Root trace wilks</term>
<term>Standard deviation</term>
<term>Statistical comparison</term>
<term>Straumann</term>
<term>Straumann group</term>
<term>Straumann groups</term>
<term>Straumann implants</term>
<term>Superstructure</term>
<term>Titanium</term>
<term>Titanium abutment</term>
<term>Veneering</term>
<term>Wilks</term>
<term>Zirconia</term>
<term>Zirconia blanks</term>
<term>Zirconium</term>
<term>Zirconium abutment</term>
<term>Zirconium abutments</term>
<term>Zirconium framework</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Abutment</term>
<term>Abutment materials</term>
<term>Amann girrbach</term>
<term>American college</term>
<term>Anisotropic shrinkage</term>
<term>Area groups</term>
<term>Astra</term>
<term>Astra group</term>
<term>Astra implants</term>
<term>Astra tech</term>
<term>Astra tech implant system</term>
<term>Axial</term>
<term>Axial measurement</term>
<term>Axial measurements</term>
<term>Base alloy</term>
<term>Ceramic veneering</term>
<term>Cerec zirconia</term>
<term>Dent</term>
<term>Dental prostheses</term>
<term>Denture</term>
<term>Fpd</term>
<term>Fpds table</term>
<term>Framework</term>
<term>Gr1a</term>
<term>Gr1i</term>
<term>Gr1i gr1a gr2i gr2a gr3i gr3a</term>
<term>Gr2a</term>
<term>Gr2i</term>
<term>Gr3a</term>
<term>Gr3i</term>
<term>Highest values</term>
<term>Implant</term>
<term>Implant abutments</term>
<term>Implant framework</term>
<term>Implant system</term>
<term>Implant systems</term>
<term>Impression material</term>
<term>Internal adaptation</term>
<term>Kahramanoglu</term>
<term>Lambda</term>
<term>Lambda trace</term>
<term>Lavatm system</term>
<term>Manufacturing conditions</term>
<term>Marginal adaptation</term>
<term>Marginal discrepancies</term>
<term>Marginal discrepancy</term>
<term>Marginal measurements</term>
<term>Marginal region</term>
<term>Metal framework</term>
<term>Nger pressure</term>
<term>Occlusal</term>
<term>Occlusal measurements</term>
<term>Occlusal surface</term>
<term>Oral maxillofac implants</term>
<term>Osseointegrated</term>
<term>Partial dentures</term>
<term>Precious alloy</term>
<term>Present study</term>
<term>Procera</term>
<term>Prosthesis</term>
<term>Prosthet</term>
<term>Prosthet dent</term>
<term>Prosthodontics</term>
<term>Prosthodontist</term>
<term>Prosthodontists kahramanoglu</term>
<term>Replica</term>
<term>Restorative materials</term>
<term>Root trace wilks</term>
<term>Standard deviation</term>
<term>Statistical comparison</term>
<term>Straumann</term>
<term>Straumann group</term>
<term>Straumann groups</term>
<term>Straumann implants</term>
<term>Superstructure</term>
<term>Titanium</term>
<term>Titanium abutment</term>
<term>Veneering</term>
<term>Wilks</term>
<term>Zirconia</term>
<term>Zirconia blanks</term>
<term>Zirconium</term>
<term>Zirconium abutment</term>
<term>Zirconium abutments</term>
<term>Zirconium framework</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Titane</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">Passive fit is generally assumed to be a significant prerequisite for long‐term implant success. The aim of this study was to evaluate the precision fit of three‐unit implant‐supported fixed partial dentures with different restorative and abutment materials on two implant systems: the Straumann and Astra Tech.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Turquie</li>
</country>
</list>
<tree>
<country name="Turquie">
<noRegion>
<name sortKey="Kahramano Lu, Erkut" sort="Kahramano Lu, Erkut" uniqKey="Kahramano Lu E" first="Erkut" last="Kahramano Lu">Erkut Kahramano Lu</name>
</noRegion>
<name sortKey="Kulak Kan, Yasemin" sort="Kulak Kan, Yasemin" uniqKey="Kulak Kan Y" first="Yasemin" last="Kulak-Özkan">Yasemin Kulak-Özkan</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002867 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002867 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:CE327B708685711FF4B7BB5985DC312349E43CE4
   |texte=   The Effect of Different Restorative and Abutment Materials on Marginal and Internal Adaptation of Three‐Unit Cantilever Implant‐Supported Fixed Partial Dentures: An In Vitro Study
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022