Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures

Identifieur interne : 001673 ( Main/Exploration ); précédent : 001672; suivant : 001674

The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures

Auteurs : Nick Polychronakis [Grèce] ; Stavros Yannikakis [Grèce] ; Alcibiades Zissis [Grèce]

Source :

RBID : PMC:4872816

Abstract

Objective

The aim of this study was to evaluate the effect of repeated microwave disinfections on the dimensional stability of acrylic dentures.

Materials and Methods

Three groups of dentures made of a heat polymerized acrylic resin were tested. I: dentures kept in water (control group). II: dentures microwaved daily while being immersed into water (wet disinfection). III: dentures microwaved daily without being immersed into water (dry disinfection).
Measurements were taken across three reference points, on two occasions: after curing and immersion in water for 24 hours, and one week later.
Data obtained were analyzed using one-way analysis of variance (ANOVA) and Scheffe’s multiple range test.

Results

The results showed that the microwave disinfection provokes dimensional changes of the same pattern (shrinkage). The dentures which underwent wet disinfection exhibited the greatest shrinkage (p<0.05).

Conclusions

Disinfection using microwave energy may cause dimensional changes (shrinkage) of complete dentures.
The microwave “dry disinfection” method can be safely applied in everyday practice since the dimensional changes which occurred seem to be of no clinical significance.


Url:
DOI: 10.15644/asc48/4/5
PubMed: 27688376
PubMed Central: 4872816


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures</title>
<author>
<name sortKey="Polychronakis, Nick" sort="Polychronakis, Nick" uniqKey="Polychronakis N" first="Nick" last="Polychronakis">Nick Polychronakis</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">Assistant Professor, Division of Removable Prosthodontics, Dental School, National and Kapodistrian University of Athens,
<country>Greece</country>
</nlm:aff>
<country xml:lang="fr">Grèce</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Yannikakis, Stavros" sort="Yannikakis, Stavros" uniqKey="Yannikakis S" first="Stavros" last="Yannikakis">Stavros Yannikakis</name>
<affiliation wicri:level="1">
<nlm:aff id="aff2">Professor, Department of Dental Technology, Division of Removable Prosthodontics, Technological Educational Institution of Athens,
<country>Greece</country>
</nlm:aff>
<country xml:lang="fr">Grèce</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Zissis, Alcibiades" sort="Zissis, Alcibiades" uniqKey="Zissis A" first="Alcibiades" last="Zissis">Alcibiades Zissis</name>
<affiliation wicri:level="1">
<nlm:aff id="aff3">Associate Professor, Division of Removable Prosthodontics, Dental School, National and Kapodistrian University of Athens,
<country>Greece</country>
</nlm:aff>
<country xml:lang="fr">Grèce</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">27688376</idno>
<idno type="pmc">4872816</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4872816</idno>
<idno type="RBID">PMC:4872816</idno>
<idno type="doi">10.15644/asc48/4/5</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">000570</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000570</idno>
<idno type="wicri:Area/Pmc/Curation">000570</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000570</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001180</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">001180</idno>
<idno type="wicri:Area/Ncbi/Merge">006A71</idno>
<idno type="wicri:Area/Ncbi/Curation">006A71</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">006A71</idno>
<idno type="wicri:doubleKey">0001-7019:2014:Polychronakis N:the:effect:of</idno>
<idno type="wicri:Area/Main/Merge">001676</idno>
<idno type="wicri:Area/Main/Curation">001673</idno>
<idno type="wicri:Area/Main/Exploration">001673</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures</title>
<author>
<name sortKey="Polychronakis, Nick" sort="Polychronakis, Nick" uniqKey="Polychronakis N" first="Nick" last="Polychronakis">Nick Polychronakis</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">Assistant Professor, Division of Removable Prosthodontics, Dental School, National and Kapodistrian University of Athens,
<country>Greece</country>
</nlm:aff>
<country xml:lang="fr">Grèce</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Yannikakis, Stavros" sort="Yannikakis, Stavros" uniqKey="Yannikakis S" first="Stavros" last="Yannikakis">Stavros Yannikakis</name>
<affiliation wicri:level="1">
<nlm:aff id="aff2">Professor, Department of Dental Technology, Division of Removable Prosthodontics, Technological Educational Institution of Athens,
<country>Greece</country>
</nlm:aff>
<country xml:lang="fr">Grèce</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Zissis, Alcibiades" sort="Zissis, Alcibiades" uniqKey="Zissis A" first="Alcibiades" last="Zissis">Alcibiades Zissis</name>
<affiliation wicri:level="1">
<nlm:aff id="aff3">Associate Professor, Division of Removable Prosthodontics, Dental School, National and Kapodistrian University of Athens,
<country>Greece</country>
</nlm:aff>
<country xml:lang="fr">Grèce</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Acta Stomatologica Croatica</title>
<idno type="ISSN">0001-7019</idno>
<idno type="eISSN">1846-0410</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Objective</title>
<p>The aim of this study was to evaluate the effect of repeated microwave disinfections on the dimensional stability of acrylic dentures.</p>
</sec>
<sec>
<title>Materials and Methods</title>
<p>Three groups of dentures made of a heat polymerized acrylic resin were tested. I: dentures kept in water (control group). II: dentures microwaved daily while being immersed into water (wet disinfection). III: dentures microwaved daily without being immersed into water (dry disinfection).
Measurements were taken across three reference points, on two occasions: after curing and immersion in water for 24 hours, and one week later.
Data obtained were analyzed using one-way analysis of variance (ANOVA) and Scheffe’s multiple range test.</p>
</sec>
<sec>
<title>Results</title>
<p>The results showed that the microwave disinfection provokes dimensional changes of the same pattern (shrinkage). The dentures which underwent wet disinfection exhibited the greatest shrinkage (p<0.05).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>Disinfection using microwave energy may cause dimensional changes (shrinkage) of complete dentures.
The microwave “dry disinfection” method can be safely applied in everyday practice since the dimensional changes which occurred seem to be of no clinical significance.</p>
</sec>
</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Grèce</li>
</country>
</list>
<tree>
<country name="Grèce">
<noRegion>
<name sortKey="Polychronakis, Nick" sort="Polychronakis, Nick" uniqKey="Polychronakis N" first="Nick" last="Polychronakis">Nick Polychronakis</name>
</noRegion>
<name sortKey="Yannikakis, Stavros" sort="Yannikakis, Stavros" uniqKey="Yannikakis S" first="Stavros" last="Yannikakis">Stavros Yannikakis</name>
<name sortKey="Zissis, Alcibiades" sort="Zissis, Alcibiades" uniqKey="Zissis A" first="Alcibiades" last="Zissis">Alcibiades Zissis</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001673 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001673 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:4872816
   |texte=   The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:27688376" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022