Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study

Identifieur interne : 000C95 ( Main/Exploration ); précédent : 000C94; suivant : 000C96

Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study

Auteurs : Arjun Singh ; K. V. Arunkumar

Source :

RBID : PMC:4871826

Abstract

Introduction

The purpose/aim of the study conducted was to compare the efficiency between two principles of plating system, 3D non locking mini plates versus 3D locking mini plates.

Materials and Methods

A total of 20 adult patients were selected according to the inclusion criteria and divided into two groups of locking plates/screws and non-locking plates/screws of ten each. All patients were treated with 2.0 mm 3D locking and non locking mini plates and screw system. Comparison of ease of use, functional stability, operator’s comfort were tabulated.

Results

A total of 27 fractures in 20 patients were treated. Each group contained ten patients. Fracture reduction was good in all the cases. At the follow up of 3 months, all fractures had healed, only one patient had a occlusal discrepancy.

Conclusion

There was no difference in the stability in both the groups. Intra operatively locking group consumed more time in fixation as it demands precision in making a hole exactly in the centre of plate necessitating the use of drill guide. Clinical and radiographic healing was good in both the groups.


Url:
DOI: 10.1007/s12663-015-0817-y
PubMed: 27298539
PubMed Central: 4871826


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study</title>
<author>
<name sortKey="Singh, Arjun" sort="Singh, Arjun" uniqKey="Singh A" first="Arjun" last="Singh">Arjun Singh</name>
<affiliation>
<nlm:aff id="Aff1">Department of Oral and Maxillofacial Surgery, Subharti Dental College and Hospital, NH-58, Subhartipuram, Meerut, U.P. India</nlm:aff>
<wicri:noCountry code="subfield">U.P. India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Arunkumar, K V" sort="Arunkumar, K V" uniqKey="Arunkumar K" first="K. V." last="Arunkumar">K. V. Arunkumar</name>
<affiliation>
<nlm:aff id="Aff1">Department of Oral and Maxillofacial Surgery, Subharti Dental College and Hospital, NH-58, Subhartipuram, Meerut, U.P. India</nlm:aff>
<wicri:noCountry code="subfield">U.P. India</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">27298539</idno>
<idno type="pmc">4871826</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4871826</idno>
<idno type="RBID">PMC:4871826</idno>
<idno type="doi">10.1007/s12663-015-0817-y</idno>
<date when="2015">2015</date>
<idno type="wicri:Area/Pmc/Corpus">000B23</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000B23</idno>
<idno type="wicri:Area/Pmc/Curation">000B23</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000B23</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000A68</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000A68</idno>
<idno type="wicri:Area/Ncbi/Merge">006794</idno>
<idno type="wicri:Area/Ncbi/Curation">006794</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">006794</idno>
<idno type="wicri:doubleKey">0972-8279:2015:Singh A:standard:d:titanium</idno>
<idno type="wicri:Area/Main/Merge">000C97</idno>
<idno type="wicri:Area/Main/Curation">000C95</idno>
<idno type="wicri:Area/Main/Exploration">000C95</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study</title>
<author>
<name sortKey="Singh, Arjun" sort="Singh, Arjun" uniqKey="Singh A" first="Arjun" last="Singh">Arjun Singh</name>
<affiliation>
<nlm:aff id="Aff1">Department of Oral and Maxillofacial Surgery, Subharti Dental College and Hospital, NH-58, Subhartipuram, Meerut, U.P. India</nlm:aff>
<wicri:noCountry code="subfield">U.P. India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Arunkumar, K V" sort="Arunkumar, K V" uniqKey="Arunkumar K" first="K. V." last="Arunkumar">K. V. Arunkumar</name>
<affiliation>
<nlm:aff id="Aff1">Department of Oral and Maxillofacial Surgery, Subharti Dental College and Hospital, NH-58, Subhartipuram, Meerut, U.P. India</nlm:aff>
<wicri:noCountry code="subfield">U.P. India</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of Maxillofacial & Oral Surgery</title>
<idno type="ISSN">0972-8279</idno>
<idno type="eISSN">0974-942X</idno>
<imprint>
<date when="2015">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Introduction</title>
<p>The purpose/aim of the study conducted was to compare the efficiency between two principles of plating system, 3D non locking mini plates versus 3D locking mini plates.</p>
</sec>
<sec>
<title>Materials and Methods</title>
<p>A total of 20 adult patients were selected according to the inclusion criteria and divided into two groups of locking plates/screws and non-locking plates/screws of ten each. All patients were treated with 2.0 mm 3D locking and non locking mini plates and screw system. Comparison of ease of use, functional stability, operator’s comfort were tabulated.</p>
</sec>
<sec>
<title>Results</title>
<p>A total of 27 fractures in 20 patients were treated. Each group contained ten patients. Fracture reduction was good in all the cases. At the follow up of 3 months, all fractures had healed, only one patient had a occlusal discrepancy.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>There was no difference in the stability in both the groups. Intra operatively locking group consumed more time in fixation as it demands precision in making a hole exactly in the centre of plate necessitating the use of drill guide. Clinical and radiographic healing was good in both the groups.</p>
</sec>
</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Arunkumar, K V" sort="Arunkumar, K V" uniqKey="Arunkumar K" first="K. V." last="Arunkumar">K. V. Arunkumar</name>
<name sortKey="Singh, Arjun" sort="Singh, Arjun" uniqKey="Singh A" first="Arjun" last="Singh">Arjun Singh</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C95 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000C95 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:4871826
   |texte=   Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:27298539" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022