Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT: a systematic review

Identifieur interne : 000890 ( Main/Exploration ); précédent : 000889; suivant : 000891

Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT: a systematic review

Auteurs : Rebekah Goulston ; Jonathan Davies ; Keith Horner ; Frederick Murphy

Source :

RBID : PMC:4846147

Abstract

Objectives:

Current guidelines highlight the need to optimize exposure parameters on CBCT equipment to levels that are as low as diagnostically acceptable. This systematic review aimed to answer the question “Can altering operating potential (kV) and tube current exposure time product (mAs) on CBCT machines reduce radiation dose to patients undergoing dental and/or maxillofacial scans without a detrimental impact on image quality/diagnostic accuracy?”

Methods:

Studies were selected and results reported following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) method. For each individual study, two authors (RG and JD or KH) independently extracted data using a specifically designed collection form, and an overall quality value was assigned using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Any disagreements in the overall quality value of a study were resolved by discussion between the current authors.

Results:

Nearly 75% of studies were considered to be of low or very low methodological quality using the GRADE system, and more studies stated that their results applied only in the specific situations they had investigated. However, most studies demonstrated that patient dose reduction is possible without a clinically relevant reduction in image quality.

Conclusions:

For many CBCT machines, it should be possible to optimize one, or more, of the investigated exposure parameters and therefore reduce patient radiation dose, while maintaining diagnostic image quality for some diagnostic tasks. However, more rigorous research is still required.


Url:
DOI: 10.1259/dmfr.20150254
PubMed: 26732433
PubMed Central: 4846147


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT: a systematic review</title>
<author>
<name sortKey="Goulston, Rebekah" sort="Goulston, Rebekah" uniqKey="Goulston R" first="Rebekah" last="Goulston">Rebekah Goulston</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Davies, Jonathan" sort="Davies, Jonathan" uniqKey="Davies J" first="Jonathan" last="Davies">Jonathan Davies</name>
<affiliation>
<nlm:aff id="aff2"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Horner, Keith" sort="Horner, Keith" uniqKey="Horner K" first="Keith" last="Horner">Keith Horner</name>
<affiliation>
<nlm:aff id="aff2"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Murphy, Frederick" sort="Murphy, Frederick" uniqKey="Murphy F" first="Frederick" last="Murphy">Frederick Murphy</name>
<affiliation>
<nlm:aff id="aff3"></nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">26732433</idno>
<idno type="pmc">4846147</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4846147</idno>
<idno type="RBID">PMC:4846147</idno>
<idno type="doi">10.1259/dmfr.20150254</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">000777</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000777</idno>
<idno type="wicri:Area/Pmc/Curation">000777</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000777</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000750</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000750</idno>
<idno type="wicri:Area/Ncbi/Merge">006270</idno>
<idno type="wicri:Area/Ncbi/Curation">006270</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">006270</idno>
<idno type="wicri:doubleKey">0250-832X:2016:Goulston R:dose:optimization:by</idno>
<idno type="wicri:Area/Main/Merge">000890</idno>
<idno type="wicri:Area/Main/Curation">000890</idno>
<idno type="wicri:Area/Main/Exploration">000890</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT: a systematic review</title>
<author>
<name sortKey="Goulston, Rebekah" sort="Goulston, Rebekah" uniqKey="Goulston R" first="Rebekah" last="Goulston">Rebekah Goulston</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Davies, Jonathan" sort="Davies, Jonathan" uniqKey="Davies J" first="Jonathan" last="Davies">Jonathan Davies</name>
<affiliation>
<nlm:aff id="aff2"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Horner, Keith" sort="Horner, Keith" uniqKey="Horner K" first="Keith" last="Horner">Keith Horner</name>
<affiliation>
<nlm:aff id="aff2"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Murphy, Frederick" sort="Murphy, Frederick" uniqKey="Murphy F" first="Frederick" last="Murphy">Frederick Murphy</name>
<affiliation>
<nlm:aff id="aff3"></nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Dentomaxillofacial Radiology</title>
<idno type="ISSN">0250-832X</idno>
<idno type="eISSN">1476-542X</idno>
<imprint>
<date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Objectives:</title>
<p>Current guidelines highlight the need to optimize exposure parameters on CBCT equipment to levels that are as low as diagnostically acceptable. This systematic review aimed to answer the question “Can altering operating potential (kV) and tube current exposure time product (mAs) on CBCT machines reduce radiation dose to patients undergoing dental and/or maxillofacial scans without a detrimental impact on image quality/diagnostic accuracy?”</p>
</sec>
<sec>
<title>Methods:</title>
<p>Studies were selected and results reported following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) method. For each individual study, two authors (RG and JD or KH) independently extracted data using a specifically designed collection form, and an overall quality value was assigned using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Any disagreements in the overall quality value of a study were resolved by discussion between the current authors.</p>
</sec>
<sec>
<title>Results:</title>
<p>Nearly 75% of studies were considered to be of low or very low methodological quality using the GRADE system, and more studies stated that their results applied only in the specific situations they had investigated. However, most studies demonstrated that patient dose reduction is possible without a clinically relevant reduction in image quality.</p>
</sec>
<sec>
<title>Conclusions:</title>
<p>For many CBCT machines, it should be possible to optimize one, or more, of the investigated exposure parameters and therefore reduce patient radiation dose, while maintaining diagnostic image quality for some diagnostic tasks. However, more rigorous research is still required.</p>
</sec>
</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Davies, Jonathan" sort="Davies, Jonathan" uniqKey="Davies J" first="Jonathan" last="Davies">Jonathan Davies</name>
<name sortKey="Goulston, Rebekah" sort="Goulston, Rebekah" uniqKey="Goulston R" first="Rebekah" last="Goulston">Rebekah Goulston</name>
<name sortKey="Horner, Keith" sort="Horner, Keith" uniqKey="Horner K" first="Keith" last="Horner">Keith Horner</name>
<name sortKey="Murphy, Frederick" sort="Murphy, Frederick" uniqKey="Murphy F" first="Frederick" last="Murphy">Frederick Murphy</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000890 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000890 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:4846147
   |texte=   Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT: a systematic review
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:26732433" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022