Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Thermal cycling distortion of porcelain fused to metal fixed partial dentures

Identifieur interne : 009855 ( Main/Curation ); précédent : 009854; suivant : 009856

Thermal cycling distortion of porcelain fused to metal fixed partial dentures

Auteurs : Deniz Gemalmaz [Turquie] ; Semih Berksun [Turquie] ; Hasan Necdet Alkumru [Turquie] ; Cigdem Kasapoglu [Turquie]

Source :

RBID : ISTEX:CE77DD901A191752F1347AC78804F04273F0648E

Descripteurs français

English descriptors

Abstract

Abstract: Statement of problem. The initial fit of porcelain fused to metal restorations deteriorates during the firing cycle of porcelain. Purpose. This study evaluated thermal cycling distortion of 3-unit porcelain fused to metal frameworks at different firing stages. Material and methods. A master model was designed to represent the 2 abutments of a 3-unit fixed partial denture replacing a missing mandibular molar. Standard techniques were used to fabricate 10 castings. Half of the copings were cast in a Ni-Cr alloy and the other half in a Pd-Cu alloy. Framework distortion was measured by means of inner fit changes, horizontal linear measurements of the framework length, and vertical fit changes of each retainer. Measurements were made (1) initially, (2) after degassing firing, and (3) after glaze firing. Differences between the firing cycles created distortion values of the retainers in 3 dimensions. Repeated measures ANOVA was used to analyze data statistically. Results. Measured differences between the 2 firing stages ranged from –47 to 81.7 μm. For both alloy groups, retainers showed increase in vertical gap that implied poorer vertical fit after porcelain application. Mean values of inner fit change recorded for porcelain application firing were higher in magnitude than the values of metal-conditioning firing. In addition, no statistically significant differences were found among alloy types. Conclusions. A 3-dimensional distortion was observed both in Pd-Cu and Ni-Cr frameworks during porcelain firing cycle. The distortion seen after porcelain application firing was significantly greater than that seen after metal-conditioning firing. This result can be attributed to these factors, contamination of porcelain to the inner surface of metal coping and reduction in resilience of metal. (J Prosthet Dent 1998;80:654-60.)

Url:
DOI: 10.1016/S0022-3913(98)70051-4

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:CE77DD901A191752F1347AC78804F04273F0648E

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Thermal cycling distortion of porcelain fused to metal fixed partial dentures</title>
<author>
<name sortKey="Gemalmaz, Deniz" sort="Gemalmaz, Deniz" uniqKey="Gemalmaz D" first="Deniz" last="Gemalmaz">Deniz Gemalmaz</name>
</author>
<author>
<name sortKey="Berksun, Semih" sort="Berksun, Semih" uniqKey="Berksun S" first="Semih" last="Berksun">Semih Berksun</name>
</author>
<author>
<name sortKey="Alkumru, Hasan Necdet" sort="Alkumru, Hasan Necdet" uniqKey="Alkumru H" first="Hasan Necdet" last="Alkumru">Hasan Necdet Alkumru</name>
</author>
<author>
<name sortKey="Kasapoglu, Cigdem" sort="Kasapoglu, Cigdem" uniqKey="Kasapoglu C" first="Cigdem" last="Kasapoglu">Cigdem Kasapoglu</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:CE77DD901A191752F1347AC78804F04273F0648E</idno>
<date when="1998" year="1998">1998</date>
<idno type="doi">10.1016/S0022-3913(98)70051-4</idno>
<idno type="url">https://api.istex.fr/document/CE77DD901A191752F1347AC78804F04273F0648E/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">006665</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">006665</idno>
<idno type="wicri:Area/Istex/Curation">006665</idno>
<idno type="wicri:Area/Istex/Checkpoint">004513</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">004513</idno>
<idno type="wicri:doubleKey">0022-3913:1998:Gemalmaz D:thermal:cycling:distortion</idno>
<idno type="wicri:Area/Main/Merge">009D20</idno>
<idno type="wicri:Area/Main/Curation">009855</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Thermal cycling distortion of porcelain fused to metal fixed partial dentures</title>
<author>
<name sortKey="Gemalmaz, Deniz" sort="Gemalmaz, Deniz" uniqKey="Gemalmaz D" first="Deniz" last="Gemalmaz">Deniz Gemalmaz</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Faculty of Dentistry Marmara University Marmara , and Faculty of Dentistry, Ankara University Ankara</wicri:regionArea>
<wicri:noRegion>Ankara University Ankara</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Berksun, Semih" sort="Berksun, Semih" uniqKey="Berksun S" first="Semih" last="Berksun">Semih Berksun</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Faculty of Dentistry Marmara University Marmara , and Faculty of Dentistry, Ankara University Ankara</wicri:regionArea>
<wicri:noRegion>Ankara University Ankara</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Alkumru, Hasan Necdet" sort="Alkumru, Hasan Necdet" uniqKey="Alkumru H" first="Hasan Necdet" last="Alkumru">Hasan Necdet Alkumru</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Faculty of Dentistry Marmara University Marmara , and Faculty of Dentistry, Ankara University Ankara</wicri:regionArea>
<wicri:noRegion>Ankara University Ankara</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Kasapoglu, Cigdem" sort="Kasapoglu, Cigdem" uniqKey="Kasapoglu C" first="Cigdem" last="Kasapoglu">Cigdem Kasapoglu</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Faculty of Dentistry Marmara University Marmara , and Faculty of Dentistry, Ankara University Ankara</wicri:regionArea>
<wicri:noRegion>Ankara University Ankara</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">The Journal of Prosthetic Dentistry</title>
<title level="j" type="abbrev">YMPR</title>
<idno type="ISSN">0022-3913</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1998">1998</date>
<biblScope unit="volume">80</biblScope>
<biblScope unit="issue">6</biblScope>
<biblScope unit="page" from="654">654</biblScope>
<biblScope unit="page" to="660">660</biblScope>
</imprint>
<idno type="ISSN">0022-3913</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0022-3913</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Abutment</term>
<term>Alloy</term>
<term>Alloy type</term>
<term>Axial wall</term>
<term>Change values</term>
<term>Cycle alloy</term>
<term>Cycle alloy retainer</term>
<term>Cycle retainer</term>
<term>Cycling</term>
<term>Degassing</term>
<term>Dent</term>
<term>Dentistry</term>
<term>Denture</term>
<term>Distortion</term>
<term>Distortion values</term>
<term>Framework length</term>
<term>Gemalmaz</term>
<term>Inner surface</term>
<term>Internal surfaces</term>
<term>Marginal distortion</term>
<term>Marmara university</term>
<term>Master model</term>
<term>Metal conditioning</term>
<term>Metal framework</term>
<term>Metal sheets</term>
<term>Molar</term>
<term>Molar retainers</term>
<term>Partial dentures</term>
<term>Porcelain</term>
<term>Porcelain application</term>
<term>Porcelain veneering</term>
<term>Premolar</term>
<term>Prosthet</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic dentistry</term>
<term>Resilience</term>
<term>Retainer</term>
<term>Significant differences</term>
<term>Single crowns</term>
<term>Thermal cycling distortion</term>
<term>Variance results</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Abutment</term>
<term>Alloy</term>
<term>Alloy type</term>
<term>Axial wall</term>
<term>Change values</term>
<term>Cycle alloy</term>
<term>Cycle alloy retainer</term>
<term>Cycle retainer</term>
<term>Cycling</term>
<term>Degassing</term>
<term>Dent</term>
<term>Dentistry</term>
<term>Denture</term>
<term>Distortion</term>
<term>Distortion values</term>
<term>Framework length</term>
<term>Gemalmaz</term>
<term>Inner surface</term>
<term>Internal surfaces</term>
<term>Marginal distortion</term>
<term>Marmara university</term>
<term>Master model</term>
<term>Metal conditioning</term>
<term>Metal framework</term>
<term>Metal sheets</term>
<term>Molar</term>
<term>Molar retainers</term>
<term>Partial dentures</term>
<term>Porcelain</term>
<term>Porcelain application</term>
<term>Porcelain veneering</term>
<term>Premolar</term>
<term>Prosthet</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic dentistry</term>
<term>Resilience</term>
<term>Retainer</term>
<term>Significant differences</term>
<term>Single crowns</term>
<term>Thermal cycling distortion</term>
<term>Variance results</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Alliage</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Abstract: Statement of problem. The initial fit of porcelain fused to metal restorations deteriorates during the firing cycle of porcelain. Purpose. This study evaluated thermal cycling distortion of 3-unit porcelain fused to metal frameworks at different firing stages. Material and methods. A master model was designed to represent the 2 abutments of a 3-unit fixed partial denture replacing a missing mandibular molar. Standard techniques were used to fabricate 10 castings. Half of the copings were cast in a Ni-Cr alloy and the other half in a Pd-Cu alloy. Framework distortion was measured by means of inner fit changes, horizontal linear measurements of the framework length, and vertical fit changes of each retainer. Measurements were made (1) initially, (2) after degassing firing, and (3) after glaze firing. Differences between the firing cycles created distortion values of the retainers in 3 dimensions. Repeated measures ANOVA was used to analyze data statistically. Results. Measured differences between the 2 firing stages ranged from –47 to 81.7 μm. For both alloy groups, retainers showed increase in vertical gap that implied poorer vertical fit after porcelain application. Mean values of inner fit change recorded for porcelain application firing were higher in magnitude than the values of metal-conditioning firing. In addition, no statistically significant differences were found among alloy types. Conclusions. A 3-dimensional distortion was observed both in Pd-Cu and Ni-Cr frameworks during porcelain firing cycle. The distortion seen after porcelain application firing was significantly greater than that seen after metal-conditioning firing. This result can be attributed to these factors, contamination of porcelain to the inner surface of metal coping and reduction in resilience of metal. (J Prosthet Dent 1998;80:654-60.)</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009855 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Curation/biblio.hfd -nk 009855 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Curation
   |type=    RBID
   |clé=     ISTEX:CE77DD901A191752F1347AC78804F04273F0648E
   |texte=   Thermal cycling distortion of porcelain fused to metal fixed partial dentures
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022