Management of fractured implant case using loop connector fixed partial denture
Identifieur interne : 006E99 ( Istex/Curation ); précédent : 006E98; suivant : 006F00Management of fractured implant case using loop connector fixed partial denture
Auteurs : Ashish Yadav [Inde] ; Aratee Gupta [Inde] ; Amrit Tandan [Inde] ; Sulabh Kumar [Inde]Source :
- BMJ Case Reports [ 1757-790X ] ; 2013-05-24.
English descriptors
- KwdEn :
- Abutment, Anterior teeth, Connector, Dental implant, Dental implants, Denture, Diastema, Failure analysis, Fracture, Further permission, Gure, Implant, Implant case, Implant failure, Implant fracture, Implant site, Incisor, Intraoral periapical radiograph, Lateral incisor, Loop connector, Maxillary, Maxillary right, Maxillofac, Occlusal, Occlusal forces, Partial denture, Prosthesis, Retrospective study, Spring cantilever, Uttar pradesh, Yadav.
- Teeft :
- Abutment, Anterior teeth, Connector, Dental implant, Dental implants, Denture, Diastema, Failure analysis, Fracture, Further permission, Gure, Implant, Implant case, Implant failure, Implant fracture, Implant site, Incisor, Intraoral periapical radiograph, Lateral incisor, Loop connector, Maxillary, Maxillary right, Maxillofac, Occlusal, Occlusal forces, Partial denture, Prosthesis, Retrospective study, Spring cantilever, Uttar pradesh, Yadav.
Abstract
Dental implants treatment have become a common modality of treatment nowadays for the replacement of missing tooth/teeth, but there have been failures due to a number of reasons; one of the rare problems is the fracture of the dental implants fixture. It is of prime importance to understand the type/system of the implant to be placed in a site and the amount and direction of occlusal forces incurred after the loading of prosthesis.
Url:
DOI: 10.1136/bcr-2013-009858
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: Pour aller vers cette notice dans l'étape Curation :006E99
Links to Exploration step
ISTEX:DF99CD741D00E3D2E7B38448CA52F636FBA2A00CLe document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title>Management of fractured implant case using loop connector fixed partial denture</title>
<author><name sortKey="Yadav, Ashish" sort="Yadav, Ashish" uniqKey="Yadav A" first="Ashish" last="Yadav">Ashish Yadav</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Gupta, Aratee" sort="Gupta, Aratee" uniqKey="Gupta A" first="Aratee" last="Gupta">Aratee Gupta</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Tandan, Amrit" sort="Tandan, Amrit" uniqKey="Tandan A" first="Amrit" last="Tandan">Amrit Tandan</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Kumar, Sulabh" sort="Kumar, Sulabh" uniqKey="Kumar S" first="Sulabh" last="Kumar">Sulabh Kumar</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:DF99CD741D00E3D2E7B38448CA52F636FBA2A00C</idno>
<date when="2013" year="2013">2013</date>
<idno type="doi">10.1136/bcr-2013-009858</idno>
<idno type="url">https://api.istex.fr/document/DF99CD741D00E3D2E7B38448CA52F636FBA2A00C/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">006E99</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">006E99</idno>
<idno type="wicri:Area/Istex/Curation">006E99</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a">Management of fractured implant case using loop connector fixed partial denture</title>
<author><name sortKey="Yadav, Ashish" sort="Yadav, Ashish" uniqKey="Yadav A" first="Ashish" last="Yadav">Ashish Yadav</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Gupta, Aratee" sort="Gupta, Aratee" uniqKey="Gupta A" first="Aratee" last="Gupta">Aratee Gupta</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BHU, Gorakhpur, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Tandan, Amrit" sort="Tandan, Amrit" uniqKey="Tandan A" first="Amrit" last="Tandan">Amrit Tandan</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Kumar, Sulabh" sort="Kumar, Sulabh" uniqKey="Kumar S" first="Sulabh" last="Kumar">Sulabh Kumar</name>
<affiliation wicri:level="1"><mods:affiliation>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Department of Prosthodontics, BBDCODS, Lucknow, Uttar Pradesh</wicri:regionArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">BMJ Case Reports</title>
<title level="j" type="abbrev">BMJ Case Reports</title>
<idno type="eISSN">1757-790X</idno>
<imprint><publisher>BMJ Publishing Group Ltd</publisher>
<date type="published" when="2013-05-24">2013-05-24</date>
<biblScope unit="volume">2013</biblScope>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Abutment</term>
<term>Anterior teeth</term>
<term>Connector</term>
<term>Dental implant</term>
<term>Dental implants</term>
<term>Denture</term>
<term>Diastema</term>
<term>Failure analysis</term>
<term>Fracture</term>
<term>Further permission</term>
<term>Gure</term>
<term>Implant</term>
<term>Implant case</term>
<term>Implant failure</term>
<term>Implant fracture</term>
<term>Implant site</term>
<term>Incisor</term>
<term>Intraoral periapical radiograph</term>
<term>Lateral incisor</term>
<term>Loop connector</term>
<term>Maxillary</term>
<term>Maxillary right</term>
<term>Maxillofac</term>
<term>Occlusal</term>
<term>Occlusal forces</term>
<term>Partial denture</term>
<term>Prosthesis</term>
<term>Retrospective study</term>
<term>Spring cantilever</term>
<term>Uttar pradesh</term>
<term>Yadav</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Abutment</term>
<term>Anterior teeth</term>
<term>Connector</term>
<term>Dental implant</term>
<term>Dental implants</term>
<term>Denture</term>
<term>Diastema</term>
<term>Failure analysis</term>
<term>Fracture</term>
<term>Further permission</term>
<term>Gure</term>
<term>Implant</term>
<term>Implant case</term>
<term>Implant failure</term>
<term>Implant fracture</term>
<term>Implant site</term>
<term>Incisor</term>
<term>Intraoral periapical radiograph</term>
<term>Lateral incisor</term>
<term>Loop connector</term>
<term>Maxillary</term>
<term>Maxillary right</term>
<term>Maxillofac</term>
<term>Occlusal</term>
<term>Occlusal forces</term>
<term>Partial denture</term>
<term>Prosthesis</term>
<term>Retrospective study</term>
<term>Spring cantilever</term>
<term>Uttar pradesh</term>
<term>Yadav</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract">Dental implants treatment have become a common modality of treatment nowadays for the replacement of missing tooth/teeth, but there have been failures due to a number of reasons; one of the rare problems is the fracture of the dental implants fixture. It is of prime importance to understand the type/system of the implant to be placed in a site and the amount and direction of occlusal forces incurred after the loading of prosthesis.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006E99 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 006E99 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Istex |étape= Curation |type= RBID |clé= ISTEX:DF99CD741D00E3D2E7B38448CA52F636FBA2A00C |texte= Management of fractured implant case using loop connector fixed partial denture }}
This area was generated with Dilib version V0.6.32. |