Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining
Identifieur interne : 003006 ( Istex/Curation ); précédent : 003005; suivant : 003007Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining
Auteurs : Allan D. Linehan ; A. Stewart WindelerSource :
- Journal of Prosthodontics [ 1059-941X ] ; 1994-06.
English descriptors
- KwdEn :
- Abutment, Abutment analogs, Analog, Braided copper wire, Catalystactivated cyanoacrylate cement, Composite resin, Edentulous mandible, Electric discharge machining, Electrode, Framework, Gold cylinders, Implant, Implant fixture, Implant frameworks, Implant prosthesis, Laser welding, Machining, Master cast, Microstrain units, Microstrain values, Oral maxillofac implants, Orthodontic movement, Osseointegrated, Osseointegrated implants, Patient analog model, Prosthesis, Prosthet dent, Prosthetic, Prosthetic superstructure, Prosthetic superstructures, Reference voltage, Respective master, Splint, Standard deviations, Stiff diameter wires, Strain gages, Superstructure, Transfer splint, Verification splint, Workpiece.
- Teeft :
- Abutment, Abutment analogs, Analog, Braided copper wire, Catalystactivated cyanoacrylate cement, Composite resin, Edentulous mandible, Electric discharge machining, Electrode, Framework, Gold cylinders, Implant, Implant fixture, Implant frameworks, Implant prosthesis, Laser welding, Machining, Master cast, Microstrain units, Microstrain values, Oral maxillofac implants, Orthodontic movement, Osseointegrated, Osseointegrated implants, Patient analog model, Prosthesis, Prosthet dent, Prosthetic, Prosthetic superstructure, Prosthetic superstructures, Reference voltage, Respective master, Splint, Standard deviations, Stiff diameter wires, Strain gages, Superstructure, Transfer splint, Verification splint, Workpiece.
Abstract
An absolutely passive fit at the interface with the superstructure and the abutment cylinders is needed for implant longevity. In this study, a method of cast framework correction using electric discharge machining (EDM) was evaluated.
Url:
DOI: 10.1111/j.1532-849X.1994.tb00134.x
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: Pour aller vers cette notice dans l'étape Curation :003006
Links to Exploration step
ISTEX:619AEB5E3866463957C431A4FF3553ABCF05DC3DCuration
No country items
Allan D. Linehan<affiliation><mods:affiliation>Correspondence address: Allan D. Linehan, DMD, MS, Rte 1, Box 959, Astoria, OR 97103.</mods:affiliation>
<wicri:noCountry code="subField">97103.</wicri:noCountry>
</affiliation>
<affiliation><mods:affiliation>Professor, Division of Biomaterials, Department of Restorative Dentistry. University of Texas Health Science Center at San Antonio.</mods:affiliation>
<wicri:noCountry code="subField">Antonio.</wicri:noCountry>
</affiliation>
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining</title>
<author><name sortKey="Linehan, Allan D" sort="Linehan, Allan D" uniqKey="Linehan A" first="Allan D." last="Linehan">Allan D. Linehan</name>
<affiliation><mods:affiliation>Prosthodontic Resident, US Air Force Academy, Colorado Springs, CO.</mods:affiliation>
<wicri:noCountry code="subField">CO.</wicri:noCountry>
</affiliation>
<affiliation><mods:affiliation>Correspondence address: Allan D. Linehan, DMD, MS, Rte 1, Box 959, Astoria, OR 97103.</mods:affiliation>
<wicri:noCountry code="subField">97103.</wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Windeler, A Stewart" sort="Windeler, A Stewart" uniqKey="Windeler A" first="A. Stewart" last="Windeler">A. Stewart Windeler</name>
<affiliation><mods:affiliation>Professor, Division of Biomaterials, Department of Restorative Dentistry. University of Texas Health Science Center at San Antonio.</mods:affiliation>
<wicri:noCountry code="subField">Antonio.</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:619AEB5E3866463957C431A4FF3553ABCF05DC3D</idno>
<date when="1994" year="1994">1994</date>
<idno type="doi">10.1111/j.1532-849X.1994.tb00134.x</idno>
<idno type="url">https://api.istex.fr/document/619AEB5E3866463957C431A4FF3553ABCF05DC3D/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">003006</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">003006</idno>
<idno type="wicri:Area/Istex/Curation">003006</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining</title>
<author><name sortKey="Linehan, Allan D" sort="Linehan, Allan D" uniqKey="Linehan A" first="Allan D." last="Linehan">Allan D. Linehan</name>
<affiliation><mods:affiliation>Prosthodontic Resident, US Air Force Academy, Colorado Springs, CO.</mods:affiliation>
</affiliation>
<affiliation><mods:affiliation>Correspondence address: Allan D. Linehan, DMD, MS, Rte 1, Box 959, Astoria, OR 97103.</mods:affiliation>
<wicri:noCountry code="subField">97103.</wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Windeler, A Stewart" sort="Windeler, A Stewart" uniqKey="Windeler A" first="A. Stewart" last="Windeler">A. Stewart Windeler</name>
<affiliation><mods:affiliation>Professor, Division of Biomaterials, Department of Restorative Dentistry. University of Texas Health Science Center at San Antonio.</mods:affiliation>
<wicri:noCountry code="subField">Antonio.</wicri:noCountry>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Journal of Prosthodontics</title>
<title level="j" type="alt">JOURNAL OF PROSTHODONTICS</title>
<idno type="ISSN">1059-941X</idno>
<idno type="eISSN">1532-849X</idno>
<imprint><biblScope unit="vol">3</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="88">88</biblScope>
<biblScope unit="page" to="95">95</biblScope>
<biblScope unit="page-count">8</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="1994-06">1994-06</date>
</imprint>
<idno type="ISSN">1059-941X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">1059-941X</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Abutment</term>
<term>Abutment analogs</term>
<term>Analog</term>
<term>Braided copper wire</term>
<term>Catalystactivated cyanoacrylate cement</term>
<term>Composite resin</term>
<term>Edentulous mandible</term>
<term>Electric discharge machining</term>
<term>Electrode</term>
<term>Framework</term>
<term>Gold cylinders</term>
<term>Implant</term>
<term>Implant fixture</term>
<term>Implant frameworks</term>
<term>Implant prosthesis</term>
<term>Laser welding</term>
<term>Machining</term>
<term>Master cast</term>
<term>Microstrain units</term>
<term>Microstrain values</term>
<term>Oral maxillofac implants</term>
<term>Orthodontic movement</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Patient analog model</term>
<term>Prosthesis</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic superstructure</term>
<term>Prosthetic superstructures</term>
<term>Reference voltage</term>
<term>Respective master</term>
<term>Splint</term>
<term>Standard deviations</term>
<term>Stiff diameter wires</term>
<term>Strain gages</term>
<term>Superstructure</term>
<term>Transfer splint</term>
<term>Verification splint</term>
<term>Workpiece</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Abutment</term>
<term>Abutment analogs</term>
<term>Analog</term>
<term>Braided copper wire</term>
<term>Catalystactivated cyanoacrylate cement</term>
<term>Composite resin</term>
<term>Edentulous mandible</term>
<term>Electric discharge machining</term>
<term>Electrode</term>
<term>Framework</term>
<term>Gold cylinders</term>
<term>Implant</term>
<term>Implant fixture</term>
<term>Implant frameworks</term>
<term>Implant prosthesis</term>
<term>Laser welding</term>
<term>Machining</term>
<term>Master cast</term>
<term>Microstrain units</term>
<term>Microstrain values</term>
<term>Oral maxillofac implants</term>
<term>Orthodontic movement</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Patient analog model</term>
<term>Prosthesis</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic superstructure</term>
<term>Prosthetic superstructures</term>
<term>Reference voltage</term>
<term>Respective master</term>
<term>Splint</term>
<term>Standard deviations</term>
<term>Stiff diameter wires</term>
<term>Strain gages</term>
<term>Superstructure</term>
<term>Transfer splint</term>
<term>Verification splint</term>
<term>Workpiece</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">An absolutely passive fit at the interface with the superstructure and the abutment cylinders is needed for implant longevity. In this study, a method of cast framework correction using electric discharge machining (EDM) was evaluated.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003006 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 003006 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Istex |étape= Curation |type= RBID |clé= ISTEX:619AEB5E3866463957C431A4FF3553ABCF05DC3D |texte= Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining }}
This area was generated with Dilib version V0.6.32. |