Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining

Identifieur interne : 003006 ( Istex/Curation ); précédent : 003005; suivant : 003007

Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining

Auteurs : Allan D. Linehan ; A. Stewart Windeler

Source :

RBID : ISTEX:619AEB5E3866463957C431A4FF3553ABCF05DC3D

English descriptors

Abstract

An absolutely passive fit at the interface with the superstructure and the abutment cylinders is needed for implant longevity. In this study, a method of cast framework correction using electric discharge machining (EDM) was evaluated.

Url:
DOI: 10.1111/j.1532-849X.1994.tb00134.x

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:619AEB5E3866463957C431A4FF3553ABCF05DC3D

Curation

No country items

Allan D. Linehan
<affiliation>
<mods:affiliation>Correspondence address: Allan D. Linehan, DMD, MS, Rte 1, Box 959, Astoria, OR 97103.</mods:affiliation>
<wicri:noCountry code="subField">97103.</wicri:noCountry>
</affiliation>
A. Stewart Windeler
<affiliation>
<mods:affiliation>Professor, Division of Biomaterials, Department of Restorative Dentistry. University of Texas Health Science Center at San Antonio.</mods:affiliation>
<wicri:noCountry code="subField">Antonio.</wicri:noCountry>
</affiliation>

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining</title>
<author>
<name sortKey="Linehan, Allan D" sort="Linehan, Allan D" uniqKey="Linehan A" first="Allan D." last="Linehan">Allan D. Linehan</name>
<affiliation>
<mods:affiliation>Prosthodontic Resident, US Air Force Academy, Colorado Springs, CO.</mods:affiliation>
<wicri:noCountry code="subField">CO.</wicri:noCountry>
</affiliation>
<affiliation>
<mods:affiliation>Correspondence address: Allan D. Linehan, DMD, MS, Rte 1, Box 959, Astoria, OR 97103.</mods:affiliation>
<wicri:noCountry code="subField">97103.</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Windeler, A Stewart" sort="Windeler, A Stewart" uniqKey="Windeler A" first="A. Stewart" last="Windeler">A. Stewart Windeler</name>
<affiliation>
<mods:affiliation>Professor, Division of Biomaterials, Department of Restorative Dentistry. University of Texas Health Science Center at San Antonio.</mods:affiliation>
<wicri:noCountry code="subField">Antonio.</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:619AEB5E3866463957C431A4FF3553ABCF05DC3D</idno>
<date when="1994" year="1994">1994</date>
<idno type="doi">10.1111/j.1532-849X.1994.tb00134.x</idno>
<idno type="url">https://api.istex.fr/document/619AEB5E3866463957C431A4FF3553ABCF05DC3D/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">003006</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">003006</idno>
<idno type="wicri:Area/Istex/Curation">003006</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining</title>
<author>
<name sortKey="Linehan, Allan D" sort="Linehan, Allan D" uniqKey="Linehan A" first="Allan D." last="Linehan">Allan D. Linehan</name>
<affiliation>
<mods:affiliation>Prosthodontic Resident, US Air Force Academy, Colorado Springs, CO.</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>Correspondence address: Allan D. Linehan, DMD, MS, Rte 1, Box 959, Astoria, OR 97103.</mods:affiliation>
<wicri:noCountry code="subField">97103.</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Windeler, A Stewart" sort="Windeler, A Stewart" uniqKey="Windeler A" first="A. Stewart" last="Windeler">A. Stewart Windeler</name>
<affiliation>
<mods:affiliation>Professor, Division of Biomaterials, Department of Restorative Dentistry. University of Texas Health Science Center at San Antonio.</mods:affiliation>
<wicri:noCountry code="subField">Antonio.</wicri:noCountry>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Journal of Prosthodontics</title>
<title level="j" type="alt">JOURNAL OF PROSTHODONTICS</title>
<idno type="ISSN">1059-941X</idno>
<idno type="eISSN">1532-849X</idno>
<imprint>
<biblScope unit="vol">3</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="88">88</biblScope>
<biblScope unit="page" to="95">95</biblScope>
<biblScope unit="page-count">8</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="1994-06">1994-06</date>
</imprint>
<idno type="ISSN">1059-941X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1059-941X</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Abutment</term>
<term>Abutment analogs</term>
<term>Analog</term>
<term>Braided copper wire</term>
<term>Catalystactivated cyanoacrylate cement</term>
<term>Composite resin</term>
<term>Edentulous mandible</term>
<term>Electric discharge machining</term>
<term>Electrode</term>
<term>Framework</term>
<term>Gold cylinders</term>
<term>Implant</term>
<term>Implant fixture</term>
<term>Implant frameworks</term>
<term>Implant prosthesis</term>
<term>Laser welding</term>
<term>Machining</term>
<term>Master cast</term>
<term>Microstrain units</term>
<term>Microstrain values</term>
<term>Oral maxillofac implants</term>
<term>Orthodontic movement</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Patient analog model</term>
<term>Prosthesis</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic superstructure</term>
<term>Prosthetic superstructures</term>
<term>Reference voltage</term>
<term>Respective master</term>
<term>Splint</term>
<term>Standard deviations</term>
<term>Stiff diameter wires</term>
<term>Strain gages</term>
<term>Superstructure</term>
<term>Transfer splint</term>
<term>Verification splint</term>
<term>Workpiece</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Abutment</term>
<term>Abutment analogs</term>
<term>Analog</term>
<term>Braided copper wire</term>
<term>Catalystactivated cyanoacrylate cement</term>
<term>Composite resin</term>
<term>Edentulous mandible</term>
<term>Electric discharge machining</term>
<term>Electrode</term>
<term>Framework</term>
<term>Gold cylinders</term>
<term>Implant</term>
<term>Implant fixture</term>
<term>Implant frameworks</term>
<term>Implant prosthesis</term>
<term>Laser welding</term>
<term>Machining</term>
<term>Master cast</term>
<term>Microstrain units</term>
<term>Microstrain values</term>
<term>Oral maxillofac implants</term>
<term>Orthodontic movement</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Patient analog model</term>
<term>Prosthesis</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic superstructure</term>
<term>Prosthetic superstructures</term>
<term>Reference voltage</term>
<term>Respective master</term>
<term>Splint</term>
<term>Standard deviations</term>
<term>Stiff diameter wires</term>
<term>Strain gages</term>
<term>Superstructure</term>
<term>Transfer splint</term>
<term>Verification splint</term>
<term>Workpiece</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">An absolutely passive fit at the interface with the superstructure and the abutment cylinders is needed for implant longevity. In this study, a method of cast framework correction using electric discharge machining (EDM) was evaluated.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003006 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 003006 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Istex
   |étape=   Curation
   |type=    RBID
   |clé=     ISTEX:619AEB5E3866463957C431A4FF3553ABCF05DC3D
   |texte=   Passive Fit of Implant‐Retained Prosthetic Superstructures Improved by Electric Discharge Machining
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022