Immediate semi‐static loading using compression healing abutments: case report
Identifieur interne : 007466 ( Istex/Corpus ); précédent : 007465; suivant : 007467Immediate semi‐static loading using compression healing abutments: case report
Auteurs : J. Cano ; J. Campo ; C. Colmenero ; A. BasconesSource :
- Oral Surgery [ 1752-2471 ] ; 2010-05.
English descriptors
- KwdEn :
- Abutment, Bone quality, Buccofacial medicine, Cano, Case report, Clin, Clin implant dent relat, Compression abutments, Dental implants, Distal implant, Dynamic load, Early loading protocols, Immediate loading protocols, Implant, Implant platform, Implant stability, Implant stability quotient, John wiley sons, Lateral, Lateral loading, Loading cano, Madrid, Maxillary, Maxillary edentulism, Medial, Medial implant, Oral maxillofac implants, Oral surgery, Primary stability, Protocol, Quadrant, Static load, Titanium implants.
- Teeft :
- Abutment, Bone quality, Buccofacial medicine, Cano, Case report, Clin, Clin implant dent relat, Compression abutments, Dental implants, Distal implant, Dynamic load, Early loading protocols, Immediate loading protocols, Implant, Implant platform, Implant stability, Implant stability quotient, John wiley sons, Lateral, Lateral loading, Loading cano, Madrid, Maxillary, Maxillary edentulism, Medial, Medial implant, Oral maxillofac implants, Oral surgery, Primary stability, Protocol, Quadrant, Static load, Titanium implants.
Abstract
Prosthodontic rehabilitation with maxillary implants can be delayed by the low density of available bone. We report the rehabilitation of maxillary edentulism with four implants, in which primary stability was enhanced by using a compression abutment prototype. Application of compression and tension to the peri‐implant bone improved resonance frequency values in all four implants at 7 days after the compression protocol.
Url:
DOI: 10.1111/j.1752-248X.2010.01076.x
Links to Exploration step
ISTEX:EB88E56B196DB311B022773F0D364E28AE17B0E3Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Immediate semi‐static loading using compression healing abutments: case report</title>
<author><name sortKey="Cano, J" sort="Cano, J" uniqKey="Cano J" first="J." last="Cano">J. Cano</name>
<affiliation><mods:affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</mods:affiliation>
</affiliation>
<affiliation><mods:affiliation>E-mail: jo.cano@wanadoo.es</mods:affiliation>
</affiliation>
</author>
<author><name sortKey="Campo, J" sort="Campo, J" uniqKey="Campo J" first="J." last="Campo">J. Campo</name>
<affiliation><mods:affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</mods:affiliation>
</affiliation>
</author>
<author><name sortKey="Colmenero, C" sort="Colmenero, C" uniqKey="Colmenero C" first="C." last="Colmenero">C. Colmenero</name>
<affiliation><mods:affiliation>Oral and Maxillofacial Surgeon, Private Practice, Madrid, Spain</mods:affiliation>
</affiliation>
</author>
<author><name sortKey="Bascones, A" sort="Bascones, A" uniqKey="Bascones A" first="A." last="Bascones">A. Bascones</name>
<affiliation><mods:affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:EB88E56B196DB311B022773F0D364E28AE17B0E3</idno>
<date when="2010" year="2010">2010</date>
<idno type="doi">10.1111/j.1752-248X.2010.01076.x</idno>
<idno type="url">https://api.istex.fr/document/EB88E56B196DB311B022773F0D364E28AE17B0E3/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">007466</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">007466</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">Immediate semi‐static loading using compression healing abutments: case report</title>
<author><name sortKey="Cano, J" sort="Cano, J" uniqKey="Cano J" first="J." last="Cano">J. Cano</name>
<affiliation><mods:affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</mods:affiliation>
</affiliation>
<affiliation><mods:affiliation>E-mail: jo.cano@wanadoo.es</mods:affiliation>
</affiliation>
</author>
<author><name sortKey="Campo, J" sort="Campo, J" uniqKey="Campo J" first="J." last="Campo">J. Campo</name>
<affiliation><mods:affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</mods:affiliation>
</affiliation>
</author>
<author><name sortKey="Colmenero, C" sort="Colmenero, C" uniqKey="Colmenero C" first="C." last="Colmenero">C. Colmenero</name>
<affiliation><mods:affiliation>Oral and Maxillofacial Surgeon, Private Practice, Madrid, Spain</mods:affiliation>
</affiliation>
</author>
<author><name sortKey="Bascones, A" sort="Bascones, A" uniqKey="Bascones A" first="A." last="Bascones">A. Bascones</name>
<affiliation><mods:affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Oral Surgery</title>
<title level="j" type="alt">ORAL SURGERY</title>
<idno type="ISSN">1752-2471</idno>
<idno type="eISSN">1752-248X</idno>
<imprint><biblScope unit="vol">3</biblScope>
<biblScope unit="issue">1‐2</biblScope>
<biblScope unit="page" from="36">36</biblScope>
<biblScope unit="page" to="39">39</biblScope>
<biblScope unit="page-count">4</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2010-05">2010-05</date>
</imprint>
<idno type="ISSN">1752-2471</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">1752-2471</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Abutment</term>
<term>Bone quality</term>
<term>Buccofacial medicine</term>
<term>Cano</term>
<term>Case report</term>
<term>Clin</term>
<term>Clin implant dent relat</term>
<term>Compression abutments</term>
<term>Dental implants</term>
<term>Distal implant</term>
<term>Dynamic load</term>
<term>Early loading protocols</term>
<term>Immediate loading protocols</term>
<term>Implant</term>
<term>Implant platform</term>
<term>Implant stability</term>
<term>Implant stability quotient</term>
<term>John wiley sons</term>
<term>Lateral</term>
<term>Lateral loading</term>
<term>Loading cano</term>
<term>Madrid</term>
<term>Maxillary</term>
<term>Maxillary edentulism</term>
<term>Medial</term>
<term>Medial implant</term>
<term>Oral maxillofac implants</term>
<term>Oral surgery</term>
<term>Primary stability</term>
<term>Protocol</term>
<term>Quadrant</term>
<term>Static load</term>
<term>Titanium implants</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Abutment</term>
<term>Bone quality</term>
<term>Buccofacial medicine</term>
<term>Cano</term>
<term>Case report</term>
<term>Clin</term>
<term>Clin implant dent relat</term>
<term>Compression abutments</term>
<term>Dental implants</term>
<term>Distal implant</term>
<term>Dynamic load</term>
<term>Early loading protocols</term>
<term>Immediate loading protocols</term>
<term>Implant</term>
<term>Implant platform</term>
<term>Implant stability</term>
<term>Implant stability quotient</term>
<term>John wiley sons</term>
<term>Lateral</term>
<term>Lateral loading</term>
<term>Loading cano</term>
<term>Madrid</term>
<term>Maxillary</term>
<term>Maxillary edentulism</term>
<term>Medial</term>
<term>Medial implant</term>
<term>Oral maxillofac implants</term>
<term>Oral surgery</term>
<term>Primary stability</term>
<term>Protocol</term>
<term>Quadrant</term>
<term>Static load</term>
<term>Titanium implants</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Prosthodontic rehabilitation with maxillary implants can be delayed by the low density of available bone. We report the rehabilitation of maxillary edentulism with four implants, in which primary stability was enhanced by using a compression abutment prototype. Application of compression and tension to the peri‐implant bone improved resonance frequency values in all four implants at 7 days after the compression protocol.</div>
</front>
</TEI>
<istex><corpusName>wiley</corpusName>
<keywords><teeft><json:string>implant</json:string>
<json:string>abutment</json:string>
<json:string>quadrant</json:string>
<json:string>compression abutments</json:string>
<json:string>cano</json:string>
<json:string>medial</json:string>
<json:string>john wiley sons</json:string>
<json:string>maxillary</json:string>
<json:string>clin</json:string>
<json:string>medial implant</json:string>
<json:string>distal implant</json:string>
<json:string>oral surgery</json:string>
<json:string>primary stability</json:string>
<json:string>titanium implants</json:string>
<json:string>lateral loading</json:string>
<json:string>maxillary edentulism</json:string>
<json:string>madrid</json:string>
<json:string>case report</json:string>
<json:string>dental implants</json:string>
<json:string>loading cano</json:string>
<json:string>clin implant dent relat</json:string>
<json:string>buccofacial medicine</json:string>
<json:string>implant stability quotient</json:string>
<json:string>bone quality</json:string>
<json:string>implant platform</json:string>
<json:string>dynamic load</json:string>
<json:string>static load</json:string>
<json:string>immediate loading protocols</json:string>
<json:string>implant stability</json:string>
<json:string>oral maxillofac implants</json:string>
<json:string>early loading protocols</json:string>
<json:string>lateral</json:string>
<json:string>protocol</json:string>
</teeft>
</keywords>
<author><json:item><name>J. Cano</name>
<affiliations><json:string>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</json:string>
<json:string>E-mail: jo.cano@wanadoo.es</json:string>
</affiliations>
</json:item>
<json:item><name>J. Campo</name>
<affiliations><json:string>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</json:string>
</affiliations>
</json:item>
<json:item><name>C. Colmenero</name>
<affiliations><json:string>Oral and Maxillofacial Surgeon, Private Practice, Madrid, Spain</json:string>
</affiliations>
</json:item>
<json:item><name>A. Bascones</name>
<affiliations><json:string>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</json:string>
</affiliations>
</json:item>
</author>
<subject><json:item><lang><json:string>eng</json:string>
</lang>
<value>compression healing</value>
</json:item>
<json:item><lang><json:string>eng</json:string>
</lang>
<value>dental implants</value>
</json:item>
<json:item><lang><json:string>eng</json:string>
</lang>
<value>immediate loading</value>
</json:item>
</subject>
<articleId><json:string>ORS1076</json:string>
</articleId>
<arkIstex>ark:/67375/WNG-R4RGW22L-1</arkIstex>
<language><json:string>eng</json:string>
</language>
<originalGenre><json:string>caseStudy</json:string>
</originalGenre>
<abstract>Prosthodontic rehabilitation with maxillary implants can be delayed by the low density of available bone. We report the rehabilitation of maxillary edentulism with four implants, in which primary stability was enhanced by using a compression abutment prototype. Application of compression and tension to the peri‐implant bone improved resonance frequency values in all four implants at 7 days after the compression protocol.</abstract>
<qualityIndicators><score>4.267</score>
<pdfWordCount>1535</pdfWordCount>
<pdfCharCount>10417</pdfCharCount>
<pdfVersion>1.3</pdfVersion>
<pdfPageCount>4</pdfPageCount>
<pdfPageSize>595.276 x 782.362 pts</pdfPageSize>
<refBibsNative>true</refBibsNative>
<abstractWordCount>61</abstractWordCount>
<abstractCharCount>424</abstractCharCount>
<keywordCount>3</keywordCount>
</qualityIndicators>
<title>Immediate semi‐static loading using compression healing abutments: case report</title>
<genre><json:string>case-report</json:string>
</genre>
<host><title>Oral Surgery</title>
<language><json:string>unknown</json:string>
</language>
<doi><json:string>10.1111/(ISSN)1752-248X</json:string>
</doi>
<issn><json:string>1752-2471</json:string>
</issn>
<eissn><json:string>1752-248X</json:string>
</eissn>
<publisherId><json:string>ORS</json:string>
</publisherId>
<volume>3</volume>
<issue>1‐2</issue>
<pages><first>36</first>
<last>39</last>
<total>4</total>
</pages>
<genre><json:string>journal</json:string>
</genre>
<subject><json:item><value>CASE REPORT</value>
</json:item>
</subject>
</host>
<namedEntities><unitex><date><json:string>2010</json:string>
</date>
<geogName></geogName>
<orgName><json:string>Complutense University</json:string>
<json:string>Spain Oral and Maxillofacial Surgeon</json:string>
<json:string>Madrid Spain Tel</json:string>
<json:string>Dentistry Complutense University</json:string>
<json:string>Cano Department of Buccofacial Medicine and Surgery</json:string>
</orgName>
<orgName_funder></orgName_funder>
<orgName_provider></orgName_provider>
<persName><json:string>John Wiley</json:string>
<json:string>C. Colmenero</json:string>
<json:string>A. Bascones</json:string>
<json:string>J. Campo</json:string>
<json:string>Case</json:string>
</persName>
<placeName><json:string>Madrid</json:string>
<json:string>Spain</json:string>
</placeName>
<ref_url></ref_url>
<ref_bibl><json:string>Cano et al.</json:string>
</ref_bibl>
<bibl></bibl>
</unitex>
</namedEntities>
<ark><json:string>ark:/67375/WNG-R4RGW22L-1</json:string>
</ark>
<categories><wos></wos>
<scienceMetrix></scienceMetrix>
<scopus><json:string>1 - Health Sciences</json:string>
<json:string>2 - Dentistry</json:string>
<json:string>3 - Oral Surgery</json:string>
<json:string>1 - Health Sciences</json:string>
<json:string>2 - Medicine</json:string>
<json:string>3 - Surgery</json:string>
</scopus>
<inist><json:string>1 - sciences appliquees, technologies et medecines</json:string>
<json:string>2 - sciences biologiques et medicales</json:string>
<json:string>3 - sciences medicales</json:string>
<json:string>4 - otorhinolaryngologie. stomatologie</json:string>
</inist>
</categories>
<publicationDate>2010</publicationDate>
<copyrightDate>2010</copyrightDate>
<doi><json:string>10.1111/j.1752-248X.2010.01076.x</json:string>
</doi>
<id>EB88E56B196DB311B022773F0D364E28AE17B0E3</id>
<score>1</score>
<fulltext><json:item><extension>pdf</extension>
<original>true</original>
<mimetype>application/pdf</mimetype>
<uri>https://api.istex.fr/document/EB88E56B196DB311B022773F0D364E28AE17B0E3/fulltext/pdf</uri>
</json:item>
<json:item><extension>zip</extension>
<original>false</original>
<mimetype>application/zip</mimetype>
<uri>https://api.istex.fr/document/EB88E56B196DB311B022773F0D364E28AE17B0E3/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/EB88E56B196DB311B022773F0D364E28AE17B0E3/fulltext/tei"><teiHeader><fileDesc><titleStmt><title level="a" type="main">Immediate semi‐static loading using compression healing abutments: case report</title>
</titleStmt>
<publicationStmt><authority>ISTEX</authority>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<availability><licence>© 2010 John Wiley & Sons A/S</licence>
</availability>
<date type="published" when="2010-05"></date>
</publicationStmt>
<notesStmt><note type="content-type" subtype="case-report" source="caseStudy" scheme="https://content-type.data.istex.fr/ark:/67375/XTP-29919SZJ-6">case-report</note>
<note type="publication-type" subtype="journal" scheme="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</note>
</notesStmt>
<sourceDesc><biblStruct type="case-report"><analytic><title level="a" type="main">Immediate semi‐static loading using compression healing abutments: case report</title>
<title level="a" type="short">Immediate semi‐static loading</title>
<author xml:id="author-0000" role="corresp"><persName><forename type="first">J.</forename>
<surname>Cano</surname>
</persName>
<affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain<address><country key="ES"></country>
</address>
</affiliation>
<affiliation>Dr J Cano
Department of Buccofacial Medicine and Surgery
School of Dentistry
Complutense University of Madrid
28040 Madrid
Spain
Tel.: +34 913941970
Fax: +34913941973
email: jo.cano@wanadoo.es</affiliation>
</author>
<author xml:id="author-0001"><persName><forename type="first">J.</forename>
<surname>Campo</surname>
</persName>
<affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain<address><country key="ES"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0002"><persName><forename type="first">C.</forename>
<surname>Colmenero</surname>
</persName>
<affiliation>Oral and Maxillofacial Surgeon, Private Practice, Madrid, Spain<address><country key="ES"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0003"><persName><forename type="first">A.</forename>
<surname>Bascones</surname>
</persName>
<affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain<address><country key="ES"></country>
</address>
</affiliation>
</author>
<idno type="istex">EB88E56B196DB311B022773F0D364E28AE17B0E3</idno>
<idno type="ark">ark:/67375/WNG-R4RGW22L-1</idno>
<idno type="DOI">10.1111/j.1752-248X.2010.01076.x</idno>
<idno type="unit">ORS1076</idno>
<idno type="toTypesetVersion">file:ORS.ORS1076.pdf</idno>
</analytic>
<monogr><title level="j" type="main">Oral Surgery</title>
<title level="j" type="alt">ORAL SURGERY</title>
<idno type="pISSN">1752-2471</idno>
<idno type="eISSN">1752-248X</idno>
<idno type="book-DOI">10.1111/(ISSN)1752-248X</idno>
<idno type="book-part-DOI">10.1111/ors.2010.3.issue-1-2</idno>
<idno type="product">ORS</idno>
<idno type="publisherDivision">ST</idno>
<imprint><biblScope unit="vol">3</biblScope>
<biblScope unit="issue">1‐2</biblScope>
<biblScope unit="page" from="36">36</biblScope>
<biblScope unit="page" to="39">39</biblScope>
<biblScope unit="page-count">4</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2010-05"></date>
</imprint>
</monogr>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><abstract xml:lang="en" style="main"><head>Abstract</head>
<p>Prosthodontic rehabilitation with maxillary implants can be delayed by the low density of available bone. We report the rehabilitation of maxillary edentulism with four implants, in which primary stability was enhanced by using a compression abutment prototype. Application of compression and tension to the peri‐implant bone improved resonance frequency values in all four implants at 7 days after the compression protocol.</p>
</abstract>
<textClass><keywords xml:lang="en"><term xml:id="k1">compression healing</term>
<term xml:id="k2">dental implants</term>
<term xml:id="k3">immediate loading</term>
</keywords>
<keywords rend="tocHeading1"><term>Case Reports</term>
</keywords>
<keywords rend="articleCategory"><term>CASE REPORT</term>
</keywords>
</textClass>
<langUsage><language ident="en"></language>
</langUsage>
</profileDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item><extension>txt</extension>
<original>false</original>
<mimetype>text/plain</mimetype>
<uri>https://api.istex.fr/document/EB88E56B196DB311B022773F0D364E28AE17B0E3/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata><istex:metadataXml wicri:clean="Wiley, elements deleted: body"><istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document><component version="2.0" type="serialArticle" xml:lang="en"><header><publicationMeta level="product"><publisherInfo><publisherName>Blackwell Publishing Ltd</publisherName>
<publisherLoc>Oxford, UK</publisherLoc>
</publisherInfo>
<doi origin="wiley" registered="yes">10.1111/(ISSN)1752-248X</doi>
<issn type="print">1752-2471</issn>
<issn type="electronic">1752-248X</issn>
<idGroup><id type="product" value="ORS"></id>
<id type="publisherDivision" value="ST"></id>
</idGroup>
<titleGroup><title type="main" sort="ORAL SURGERY">Oral Surgery</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="05101"><doi origin="wiley">10.1111/ors.2010.3.issue-1-2</doi>
<numberingGroup><numbering type="journalVolume" number="3">3</numbering>
<numbering type="journalIssue">1‐2</numbering>
</numberingGroup>
<coverDate startDate="2010-05">May 2010</coverDate>
</publicationMeta>
<publicationMeta level="unit" type="caseStudy" position="9" status="forIssue"><doi origin="wiley">10.1111/j.1752-248X.2010.01076.x</doi>
<idGroup><id type="unit" value="ORS1076"></id>
</idGroup>
<countGroup><count type="pageTotal" number="4"></count>
</countGroup>
<titleGroup><title type="tocHeading1">Case Reports</title>
<title type="articleCategory">CASE REPORT</title>
</titleGroup>
<copyright>© 2010 John Wiley & Sons A/S</copyright>
<eventGroup><event type="firstOnline" date="2010-06-14"></event>
<event type="publishedOnlineFinalForm" date="2010-07-16"></event>
<event type="publishedOnlineAcceptedOrEarlyUnpaginated" date="2010-06-14"></event>
<event type="xmlConverted" agent="Converter:BPG_TO_WML3G version:2.3.27 mode:FullText source:FullText result:FullText" date="2010-11-22"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:3.8.8" date="2014-02-06"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.1.7 mode:FullText,remove_FC" date="2014-11-03"></event>
</eventGroup>
<numberingGroup><numbering type="pageFirst" number="36">36</numbering>
<numbering type="pageLast" number="39">39</numbering>
</numberingGroup>
<correspondenceTo>Dr J Cano
Department of Buccofacial Medicine and Surgery
School of Dentistry
Complutense University of Madrid
28040 Madrid
Spain
Tel.: +34 913941970
Fax: +34913941973
email: <email>jo.cano@wanadoo.es</email>
</correspondenceTo>
<linkGroup><link type="toTypesetVersion" href="file:ORS.ORS1076.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta><unparsedEditorialHistory>Accepted: 22 April 2010</unparsedEditorialHistory>
<countGroup><count type="figureTotal" number="8"></count>
<count type="tableTotal" number="0"></count>
<count type="formulaTotal" number="0"></count>
<count type="referenceTotal" number="12"></count>
<count type="wordTotal" number="1797"></count>
<count type="linksPubMed" number="0"></count>
<count type="linksCrossRef" number="0"></count>
</countGroup>
<titleGroup><title type="main">Immediate semi‐static loading using compression healing abutments: case report</title>
<title type="shortAuthors">Cano <i>et al</i>
.</title>
<title type="short">Immediate semi‐static loading</title>
</titleGroup>
<creators><creator creatorRole="author" xml:id="cr1" affiliationRef="#a1" corresponding="yes"><personName><givenNames>J.</givenNames>
<familyName>Cano</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr2" affiliationRef="#a1"><personName><givenNames>J.</givenNames>
<familyName>Campo</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr3" affiliationRef="#a2"><personName><givenNames>C.</givenNames>
<familyName>Colmenero</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr4" affiliationRef="#a1"><personName><givenNames>A.</givenNames>
<familyName>Bascones</familyName>
</personName>
</creator>
</creators>
<affiliationGroup><affiliation xml:id="a1" countryCode="ES"><unparsedAffiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</unparsedAffiliation>
</affiliation>
<affiliation xml:id="a2" countryCode="ES"><unparsedAffiliation>Oral and Maxillofacial Surgeon, Private Practice, Madrid, Spain</unparsedAffiliation>
</affiliation>
</affiliationGroup>
<keywordGroup xml:lang="en"><keyword xml:id="k1">compression healing</keyword>
<keyword xml:id="k2">dental implants</keyword>
<keyword xml:id="k3">immediate loading</keyword>
</keywordGroup>
<abstractGroup><abstract type="main" xml:lang="en"><title type="main">Abstract</title>
<p>Prosthodontic rehabilitation with maxillary implants can be delayed by the low density of available bone. We report the rehabilitation of maxillary edentulism with four implants, in which primary stability was enhanced by using a compression abutment prototype. Application of compression and tension to the peri‐implant bone improved resonance frequency values in all four implants at 7 days after the compression protocol.</p>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<mods version="3.6"><titleInfo lang="en"><title>Immediate semi‐static loading using compression healing abutments: case report</title>
</titleInfo>
<titleInfo type="abbreviated" lang="en"><title>Immediate semi‐static loading</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en"><title>Immediate semi‐static loading using compression healing abutments: case report</title>
</titleInfo>
<name type="personal"><namePart type="given">J.</namePart>
<namePart type="family">Cano</namePart>
<affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</affiliation>
<affiliation>E-mail: jo.cano@wanadoo.es</affiliation>
<role><roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal"><namePart type="given">J.</namePart>
<namePart type="family">Campo</namePart>
<affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</affiliation>
<role><roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal"><namePart type="given">C.</namePart>
<namePart type="family">Colmenero</namePart>
<affiliation>Oral and Maxillofacial Surgeon, Private Practice, Madrid, Spain</affiliation>
<role><roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal"><namePart type="given">A.</namePart>
<namePart type="family">Bascones</namePart>
<affiliation>Department of Buccofacial Medicine and Surgery, School of Dentistry, Complutense University of Madrid, Madrid, Spain</affiliation>
<role><roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="case-report" displayLabel="caseStudy" authority="ISTEX" authorityURI="https://content-type.data.istex.fr" valueURI="https://content-type.data.istex.fr/ark:/67375/XTP-29919SZJ-6">case-report</genre>
<originInfo><publisher>Blackwell Publishing Ltd</publisher>
<place><placeTerm type="text">Oxford, UK</placeTerm>
</place>
<dateIssued encoding="w3cdtf">2010-05</dateIssued>
<edition>Accepted: 22 April 2010</edition>
<copyrightDate encoding="w3cdtf">2010</copyrightDate>
</originInfo>
<language><languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription><extent unit="figures">8</extent>
<extent unit="tables">0</extent>
<extent unit="formulas">0</extent>
<extent unit="references">12</extent>
<extent unit="linksCrossRef">0</extent>
<extent unit="words">1797</extent>
</physicalDescription>
<abstract lang="en">Prosthodontic rehabilitation with maxillary implants can be delayed by the low density of available bone. We report the rehabilitation of maxillary edentulism with four implants, in which primary stability was enhanced by using a compression abutment prototype. Application of compression and tension to the peri‐implant bone improved resonance frequency values in all four implants at 7 days after the compression protocol.</abstract>
<subject lang="en"><genre>keywords</genre>
<topic>compression healing</topic>
<topic>dental implants</topic>
<topic>immediate loading</topic>
</subject>
<relatedItem type="host"><titleInfo><title>Oral Surgery</title>
</titleInfo>
<genre type="journal" authority="ISTEX" authorityURI="https://publication-type.data.istex.fr" valueURI="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</genre>
<subject><genre>article-category</genre>
<topic>CASE REPORT</topic>
</subject>
<identifier type="ISSN">1752-2471</identifier>
<identifier type="eISSN">1752-248X</identifier>
<identifier type="DOI">10.1111/(ISSN)1752-248X</identifier>
<identifier type="PublisherID">ORS</identifier>
<part><date>2010</date>
<detail type="volume"><caption>vol.</caption>
<number>3</number>
</detail>
<detail type="issue"><caption>no.</caption>
<number>1‐2</number>
</detail>
<extent unit="pages"><start>36</start>
<end>39</end>
<total>4</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">EB88E56B196DB311B022773F0D364E28AE17B0E3</identifier>
<identifier type="ark">ark:/67375/WNG-R4RGW22L-1</identifier>
<identifier type="DOI">10.1111/j.1752-248X.2010.01076.x</identifier>
<identifier type="ArticleID">ORS1076</identifier>
<accessCondition type="use and reproduction" contentType="copyright">© 2010 John Wiley & Sons A/S</accessCondition>
<recordInfo><recordContentSource authority="ISTEX" authorityURI="https://loaded-corpus.data.istex.fr" valueURI="https://loaded-corpus.data.istex.fr/ark:/67375/XBH-L0C46X92-X">wiley</recordContentSource>
<recordOrigin>Blackwell Publishing Ltd</recordOrigin>
</recordInfo>
</mods>
<json:item><extension>json</extension>
<original>false</original>
<mimetype>application/json</mimetype>
<uri>https://api.istex.fr/document/EB88E56B196DB311B022773F0D364E28AE17B0E3/metadata/json</uri>
</json:item>
</metadata>
<serie></serie>
</istex>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 007466 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 007466 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Istex |étape= Corpus |type= RBID |clé= ISTEX:EB88E56B196DB311B022773F0D364E28AE17B0E3 |texte= Immediate semi‐static loading using compression healing abutments: case report }}
![]() | This area was generated with Dilib version V0.6.32. | ![]() |