Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial

Identifieur interne : 006B68 ( Istex/Corpus ); précédent : 006B67; suivant : 006B69

Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial

Auteurs : Gerdien Telleman ; Gerry M. Raghoebar ; Arjan Vissink ; Henny J. A. Meijer

Source :

RBID : ISTEX:D928D637AC519E25AEAE90FCE069AE88ADE08876

Abstract

Aim: To assess the effect of platform switching on peri‐implant bone remodeling around short implants (8.5 mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients.

Url:
DOI: 10.1111/j.1708-8208.2012.00461.x

Links to Exploration step

ISTEX:D928D637AC519E25AEAE90FCE069AE88ADE08876

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial</title>
<author>
<name sortKey="Telleman, Gerdien" sort="Telleman, Gerdien" uniqKey="Telleman G" first="Gerdien" last="Telleman">Gerdien Telleman</name>
<affiliation>
<mods:affiliation>Research fellow, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: g.telleman@umcg.nl</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Raghoebar, Gerry M" sort="Raghoebar, Gerry M" uniqKey="Raghoebar G" first="Gerry M." last="Raghoebar">Gerry M. Raghoebar</name>
<affiliation>
<mods:affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vissink, Arjan" sort="Vissink, Arjan" uniqKey="Vissink A" first="Arjan" last="Vissink">Arjan Vissink</name>
<affiliation>
<mods:affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Meijer, Henny J A" sort="Meijer, Henny J A" uniqKey="Meijer H" first="Henny J. A." last="Meijer">Henny J. A. Meijer</name>
<affiliation>
<mods:affiliation>Professor, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, Centre for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:D928D637AC519E25AEAE90FCE069AE88ADE08876</idno>
<date when="2014" year="2014">2014</date>
<idno type="doi">10.1111/j.1708-8208.2012.00461.x</idno>
<idno type="url">https://api.istex.fr/document/D928D637AC519E25AEAE90FCE069AE88ADE08876/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">006B68</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">006B68</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial</title>
<author>
<name sortKey="Telleman, Gerdien" sort="Telleman, Gerdien" uniqKey="Telleman G" first="Gerdien" last="Telleman">Gerdien Telleman</name>
<affiliation>
<mods:affiliation>Research fellow, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: g.telleman@umcg.nl</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Raghoebar, Gerry M" sort="Raghoebar, Gerry M" uniqKey="Raghoebar G" first="Gerry M." last="Raghoebar">Gerry M. Raghoebar</name>
<affiliation>
<mods:affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vissink, Arjan" sort="Vissink, Arjan" uniqKey="Vissink A" first="Arjan" last="Vissink">Arjan Vissink</name>
<affiliation>
<mods:affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Meijer, Henny J A" sort="Meijer, Henny J A" uniqKey="Meijer H" first="Henny J. A." last="Meijer">Henny J. A. Meijer</name>
<affiliation>
<mods:affiliation>Professor, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, Centre for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Implant Dentistry and Related Research</title>
<title level="j" type="alt">CLINICAL IMPLANT DENTISTRY RELATED RESEARCH</title>
<idno type="ISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<imprint>
<biblScope unit="vol">16</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="70">70</biblScope>
<biblScope unit="page" to="80">80</biblScope>
<biblScope unit="page-count">11</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2014-02">2014-02</date>
</imprint>
<idno type="ISSN">1523-0899</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1523-0899</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">Aim: To assess the effect of platform switching on peri‐implant bone remodeling around short implants (8.5 mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients.</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<author>
<json:item>
<name>Gerdien Telleman DDS</name>
<affiliations>
<json:string>Research fellow, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</json:string>
<json:string>E-mail: g.telleman@umcg.nl</json:string>
</affiliations>
</json:item>
<json:item>
<name>Gerry M. Raghoebar DMD, MD, PhD</name>
<affiliations>
<json:string>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</json:string>
</affiliations>
</json:item>
<json:item>
<name>Arjan Vissink DMD, MD, PhD</name>
<affiliations>
<json:string>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</json:string>
</affiliations>
</json:item>
<json:item>
<name>Henny J.A. Meijer DDS, PhD</name>
<affiliations>
<json:string>Professor, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, Centre for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>bone remodeling</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>CaP</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>dental implants</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>nano roughness</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>platform switching</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>short implants</value>
</json:item>
</subject>
<articleId>
<json:string>CID461</json:string>
</articleId>
<arkIstex>ark:/67375/WNG-LKTLJLT5-G</arkIstex>
<language>
<json:string>eng</json:string>
</language>
<originalGenre>
<json:string>article</json:string>
</originalGenre>
<abstract>Aim: To assess the effect of platform switching on peri‐implant bone remodeling around short implants (8.5 mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients.</abstract>
<qualityIndicators>
<score>6.977</score>
<pdfWordCount>4629</pdfWordCount>
<pdfCharCount>32025</pdfCharCount>
<pdfVersion>1.3</pdfVersion>
<pdfPageCount>11</pdfPageCount>
<pdfPageSize>585 x 783 pts</pdfPageSize>
<refBibsNative>true</refBibsNative>
<abstractWordCount>29</abstractWordCount>
<abstractCharCount>209</abstractCharCount>
<keywordCount>6</keywordCount>
</qualityIndicators>
<title>Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial</title>
<genre>
<json:string>article</json:string>
</genre>
<host>
<title>Clinical Implant Dentistry and Related Research</title>
<language>
<json:string>unknown</json:string>
</language>
<doi>
<json:string>10.1111/(ISSN)1708-8208</json:string>
</doi>
<issn>
<json:string>1523-0899</json:string>
</issn>
<eissn>
<json:string>1708-8208</json:string>
</eissn>
<publisherId>
<json:string>CID</json:string>
</publisherId>
<volume>16</volume>
<issue>1</issue>
<pages>
<first>70</first>
<last>80</last>
<total>11</total>
</pages>
<genre>
<json:string>journal</json:string>
</genre>
<subject>
<json:item>
<value>ARTICLE</value>
</json:item>
</subject>
</host>
<ark>
<json:string>ark:/67375/WNG-LKTLJLT5-G</json:string>
</ark>
<publicationDate>2014</publicationDate>
<copyrightDate>2014</copyrightDate>
<doi>
<json:string>10.1111/j.1708-8208.2012.00461.x</json:string>
</doi>
<id>D928D637AC519E25AEAE90FCE069AE88ADE08876</id>
<score>1</score>
<fulltext>
<json:item>
<extension>pdf</extension>
<original>true</original>
<mimetype>application/pdf</mimetype>
<uri>https://api.istex.fr/document/D928D637AC519E25AEAE90FCE069AE88ADE08876/fulltext/pdf</uri>
</json:item>
<json:item>
<extension>zip</extension>
<original>false</original>
<mimetype>application/zip</mimetype>
<uri>https://api.istex.fr/document/D928D637AC519E25AEAE90FCE069AE88ADE08876/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/D928D637AC519E25AEAE90FCE069AE88ADE08876/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a" type="main">Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<availability>
<licence>© 2012 Wiley Periodicals, Inc.</licence>
</availability>
<date type="published" when="2014-02"></date>
</publicationStmt>
<notesStmt>
<note type="content-type" subtype="article" source="article" scheme="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</note>
<note type="publication-type" subtype="journal" scheme="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</note>
</notesStmt>
<sourceDesc>
<biblStruct type="article">
<analytic>
<title level="a" type="main">Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial</title>
<title level="a" type="short">Platform Switching of Short Implants</title>
<author xml:id="author-0000" role="corresp">
<persName>
<forename type="first">Gerdien</forename>
<surname>Telleman</surname>
<roleName type="degree">DDS</roleName>
</persName>
<affiliation>Research fellow, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands
<address>
<country key="NL"></country>
</address>
</affiliation>
<affiliation>Mrs. Gerdien Telleman, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, P.O. Box 30.001, 9700 RB Groningen, the Netherlands; e‐mail: g.telleman@umcg.nl</affiliation>
</author>
<author xml:id="author-0001">
<persName>
<forename type="first">Gerry M.</forename>
<surname>Raghoebar</surname>
<roleName type="degree">DMD, MD, PhD</roleName>
</persName>
<affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands
<address>
<country key="NL"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0002">
<persName>
<forename type="first">Arjan</forename>
<surname>Vissink</surname>
<roleName type="degree">DMD, MD, PhD</roleName>
</persName>
<affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands
<address>
<country key="NL"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0003">
<persName>
<forename type="first">Henny J.A.</forename>
<surname>Meijer</surname>
<roleName type="degree">DDS, PhD</roleName>
</persName>
<affiliation>Professor, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, Centre for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands
<address>
<country key="NL"></country>
</address>
</affiliation>
</author>
<idno type="istex">D928D637AC519E25AEAE90FCE069AE88ADE08876</idno>
<idno type="ark">ark:/67375/WNG-LKTLJLT5-G</idno>
<idno type="DOI">10.1111/j.1708-8208.2012.00461.x</idno>
<idno type="unit">CID461</idno>
<idno type="toTypesetVersion">file://CID.CID461.pdf</idno>
</analytic>
<monogr>
<title level="j" type="main">Clinical Implant Dentistry and Related Research</title>
<title level="j" type="alt">CLINICAL IMPLANT DENTISTRY RELATED RESEARCH</title>
<idno type="pISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<idno type="book-DOI">10.1111/(ISSN)1708-8208</idno>
<idno type="book-part-DOI">10.1111/cid.2014.16.issue-1</idno>
<idno type="product">CID</idno>
<idno type="publisherDivision">ST</idno>
<imprint>
<biblScope unit="vol">16</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="70">70</biblScope>
<biblScope unit="page" to="80">80</biblScope>
<biblScope unit="page-count">11</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2014-02"></date>
</imprint>
</monogr>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<abstract xml:lang="en" style="main">
<head>ABSTRACT</head>
<p>
<hi rend="bold">Aim:</hi>
To assess the effect of platform switching on peri‐implant bone remodeling around short implants (8.5 mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients.</p>
<p>
<hi rend="bold">Materials and Methods:</hi>
Seventeen patients with one or more missing teeth at both sides in the posterior region were, according to a split‐mouth design, randomly assigned to be treated with a platform‐matched (control) implant on the one side and a platform‐switched implant (test) on the other side. A total of 62 short implants (8.5 mm) with a dual‐acid etched surface with nanometer‐sized calcium phosphate particles was placed. Follow‐up visits were conducted one month and one year after placing the implant crown. Outcome measures were interproximal bone level changes, implant survival and clinical parameters.</p>
<p>
<hi rend="bold">Results:</hi>
One year after loading, peri‐implant bone remodeling around test implants (0.53 ± 0.54 mm) was significant less than around control implants (0.85 ± 0.65 mm;
<hi rend="italic">p</hi>
 = .003). With regard to implant survival and clinical parameters no significant differences were observed between test and control implants.</p>
<p>
<hi rend="bold">Conclusions:</hi>
This study suggested that peri‐implant bone remodeling is affected by platform switching. One year after loading, interproximal bone levels were better maintained at implants restored according to the platform switching concept.</p>
</abstract>
<textClass>
<keywords xml:lang="en">
<term xml:id="k1">bone remodeling</term>
<term xml:id="k2">CaP</term>
<term xml:id="k3">dental implants</term>
<term xml:id="k4">nano roughness</term>
<term xml:id="k5">platform switching</term>
<term xml:id="k6">short implants</term>
</keywords>
<keywords rend="tocHeading1">
<term>ARTICLES</term>
</keywords>
<keywords rend="articleCategory">
<term>ARTICLE</term>
</keywords>
</textClass>
<langUsage>
<language ident="en"></language>
</langUsage>
</profileDesc>
</teiHeader>
</istex:fulltextTEI>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body" wicri:toSee="Element documentInfo">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component version="2.0" type="serialArticle" xml:lang="en"></component>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial</title>
</titleInfo>
<titleInfo type="abbreviated" lang="en">
<title>Platform Switching of Short Implants</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial</title>
</titleInfo>
<name type="personal">
<namePart type="given">Gerdien</namePart>
<namePart type="family">Telleman</namePart>
<namePart type="termsOfAddress">DDS</namePart>
<affiliation>Research fellow, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</affiliation>
<affiliation>E-mail: g.telleman@umcg.nl</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Gerry M.</namePart>
<namePart type="family">Raghoebar</namePart>
<namePart type="termsOfAddress">DMD, MD, PhD</namePart>
<affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Arjan</namePart>
<namePart type="family">Vissink</namePart>
<namePart type="termsOfAddress">DMD, MD, PhD</namePart>
<affiliation>Professor, Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Henny J.A.</namePart>
<namePart type="family">Meijer</namePart>
<namePart type="termsOfAddress">DDS, PhD</namePart>
<affiliation>Professor, Department of Oral and Maxillofacial Surgery and Department of Fixed and Removable Prosthodontics, Centre for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="article" displayLabel="article" authority="ISTEX" authorityURI="https://content-type.data.istex.fr" valueURI="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</genre>
<originInfo>
<publisher>Blackwell Publishing Ltd</publisher>
<place>
<placeTerm type="text">Oxford, UK</placeTerm>
</place>
<dateIssued encoding="w3cdtf">2014-02</dateIssued>
<copyrightDate encoding="w3cdtf">2014</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<extent unit="figures">3</extent>
<extent unit="tables">3</extent>
<extent unit="formulas">0</extent>
<extent unit="references">45</extent>
<extent unit="linksCrossRef">0</extent>
<extent unit="words">5714</extent>
</physicalDescription>
<abstract>Aim: To assess the effect of platform switching on peri‐implant bone remodeling around short implants (8.5 mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients.</abstract>
<abstract>Materials and Methods: Seventeen patients with one or more missing teeth at both sides in the posterior region were, according to a split‐mouth design, randomly assigned to be treated with a platform‐matched (control) implant on the one side and a platform‐switched implant (test) on the other side. A total of 62 short implants (8.5 mm) with a dual‐acid etched surface with nanometer‐sized calcium phosphate particles was placed. Follow‐up visits were conducted one month and one year after placing the implant crown. Outcome measures were interproximal bone level changes, implant survival and clinical parameters.</abstract>
<abstract>Results: One year after loading, peri‐implant bone remodeling around test implants (0.53 ± 0.54 mm) was significant less than around control implants (0.85 ± 0.65 mm; p = .003). With regard to implant survival and clinical parameters no significant differences were observed between test and control implants.</abstract>
<abstract>Conclusions: This study suggested that peri‐implant bone remodeling is affected by platform switching. One year after loading, interproximal bone levels were better maintained at implants restored according to the platform switching concept.</abstract>
<note type="funding">Biomet 3i, Palm Beach Gardens, FL, USA</note>
<subject lang="en">
<genre>keywords</genre>
<topic>bone remodeling</topic>
<topic>CaP</topic>
<topic>dental implants</topic>
<topic>nano roughness</topic>
<topic>platform switching</topic>
<topic>short implants</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Clinical Implant Dentistry and Related Research</title>
</titleInfo>
<genre type="journal" authority="ISTEX" authorityURI="https://publication-type.data.istex.fr" valueURI="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</genre>
<subject>
<genre>article-category</genre>
<topic>ARTICLE</topic>
</subject>
<identifier type="ISSN">1523-0899</identifier>
<identifier type="eISSN">1708-8208</identifier>
<identifier type="DOI">10.1111/(ISSN)1708-8208</identifier>
<identifier type="PublisherID">CID</identifier>
<part>
<date>2014</date>
<detail type="volume">
<caption>vol.</caption>
<number>16</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>1</number>
</detail>
<extent unit="pages">
<start>70</start>
<end>80</end>
<total>11</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">D928D637AC519E25AEAE90FCE069AE88ADE08876</identifier>
<identifier type="ark">ark:/67375/WNG-LKTLJLT5-G</identifier>
<identifier type="DOI">10.1111/j.1708-8208.2012.00461.x</identifier>
<identifier type="ArticleID">CID461</identifier>
<accessCondition type="use and reproduction" contentType="copyright">Copyright © 2014 Wiley Periodicals, Inc.© 2012 Wiley Periodicals, Inc.</accessCondition>
<recordInfo>
<recordContentSource authority="ISTEX" authorityURI="https://loaded-corpus.data.istex.fr" valueURI="https://loaded-corpus.data.istex.fr/ark:/67375/XBH-L0C46X92-X">wiley</recordContentSource>
<recordOrigin>Blackwell Publishing Ltd</recordOrigin>
</recordInfo>
</mods>
<json:item>
<extension>json</extension>
<original>false</original>
<mimetype>application/json</mimetype>
<uri>https://api.istex.fr/document/D928D637AC519E25AEAE90FCE069AE88ADE08876/metadata/json</uri>
</json:item>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006B68 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 006B68 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:D928D637AC519E25AEAE90FCE069AE88ADE08876
   |texte=   Impact of Platform Switching on Peri‐Implant Bone Remodeling around Short Implants in the Posterior Region, 1‐Year Results from a Split‐Mouth Clinical Trial
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022